Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Agric Food Chem ; 64(8): 1817-22, 2016 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-26829049

RESUMO

The concentration of bromine and iodine was determined in shrimp and its parts (tissue and shells), and changes in the analyte concentration were evaluated after the cooking procedure. Bromine and iodine concentrations were determined by a method recently developed by our research group based on microwave-induced combustion for sample preparation and inductively coupled plasma mass spectrometry for analyte determination. The accuracy was evaluated using a reference material (NIST 8414) that was digested using the proposed method. No statistical difference was observed between certified and determined values (Student's t test, 95% confidence level). Suitable limits of detection (Br, 0.02 µg g(-1) and I, 0.01 µg g(-1)) were obtained for both analytes. Higher concentrations of both analytes were observed in shrimp shells in comparison to shrimp tissue for raw and cooked samples. Moreover, losses of Br and I (between 24 and 43%) were observed after cooking.


Assuntos
Bromo/análise , Crustáceos/química , Iodo/análise , Frutos do Mar/análise , Exoesqueleto/química , Animais , Culinária , Espectrometria de Massas
2.
Talanta ; 136: 161-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25702998

RESUMO

In this work a method for active pharmaceutical ingredients (APIs) digestion using the single reaction chamber (SRC-UltraWave™) system was proposed following the new recommendations of United States Pharmacopeia (USP). Levodope (LEVO), primaquine diphosphate (PRIM), propranolol hydrochloride (PROP) and sulfamethoxazole (SULF) were used to evaluate the digestion efficiency of the proposed method. A comparison of digestion efficiency was performed by measuring the carbon content and residual acidity in digests obtained using SRC and in digests obtained using conventional microwave-assisted digestion system (Multiwave(TM)). Three digestion solutions (concentrated HNO3, aqua regia or inverse aqua regia) were evaluated for digestion of APIs. The determination of Cd, Ir, Mn, Mo, Ni, Os, Pb, Pd, Pt, Rh, Ru was performed using inductively coupled plasma mass spectrometry (ICP-MS) in standard mode. Dynamic reaction cell (DRC) mode was used for the determination of (51)V, (52)Cr, (53)Cr, (63)Cu and (65)Cu in order to solve polyatomic ion interferences. Arsenic and Hg were determined using chemical vapor generation coupled to ICP-MS (FI-CVG-ICP-MS). Masses of 500mg of APIs were efficiently digested in a SRC-UltraWave™ system using only HNO3 and allowing a carbon content lower than 250mg L(-1) in final digests. Inverse aqua regia was suitable for digestion of sample masses up to 250mg allowing the determination of Ir, Pd, Pt, Rh and Ru. By using HNO3 or inverse aqua regia, suitable recoveries were obtained (between 91 and 109%) for all analytes (exception for Os). Limits of quantification were in agreement with USP requirements and they ranged from 0.001 to 0.015µg g(-1) for all elemental impurities (exception for Os). The proposed method was suitable for elemental impurities determination in APIs and it can be used in routine analysis for quality control in pharmaceutical industries.


Assuntos
Contaminação de Medicamentos , Metais/análise , Preparações Farmacêuticas/análise , Espectrometria de Massas/métodos , Espectrometria de Massas/normas , Farmacopeias como Assunto/normas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA