Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Sep Sci ; 39(8): 1454-60, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26914691

RESUMO

A new method was developed for the determination of ammonium ion, monomethylamine and monoethylamine in saline waters by ion chromatography. Steam distillation was used to eliminate matrix interferences. Variables such as distillation time, concentration of sodium hydroxide solution and analyte mass were optimized by using a full two-level factorial (2(3) ) design. The influence of steam distillation on the analytical curves prepared in different matrices was also investigated. Limits of detection of 0.03, 0.05 and 0.05 mg/L were obtained for ammoniumion, monomethylamine and monoethylamine, respectively. Saline water samples from the Brazilian oil industry, containing sodium and potassium concentrations between 2.0-5.2% w/v and 96-928 mg/L, respectively, were analyzed. Satisfactory recoveries (90-105%) of the analytes were obtained for all spiked samples, and the precision was ≤ 7% (n = 3). The proposed method is adequate for analyzing saline waters containing sodium to ammoniumion, monomethylamine and monoethylamine concentration ratios up to 28 000:1 and potassium to ammonium, monomethylamine and monoethylamine concentration ratios up to 12 000:1.

2.
J Chromatogr A ; 1223: 79-83, 2012 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-22226459

RESUMO

A method for determination of formic, acetic, propionic and butyric acids in hypersaline waters by ion-exclusion chromatography (IEC), using steam distillation to eliminate matrix-interference, was developed. The steam distillation variables such as type of solution to collect the distillate, distillation time and volume of the 50% v/v H2SO4 solution were optimized. The effect of the addition of NaCl different concentrations to the calibration standards on the carboxylic acid recovery was also investigated. Detection limits of 0.2, 0.5, 0.3 and 1.5 mg L⁻¹ were obtained for formic, acetic, propionic and butyric acids, respectively. Produced waters from petroleum reservoirs in the Brazilian pre-salt layer containing about 19% m/v of NaCl were analyzed. Good recoveries (99-108%) were obtained for all acids in spiked produced water samples.


Assuntos
Cromatografia por Troca Iônica/métodos , Destilação/métodos , Ácidos Graxos Voláteis/isolamento & purificação , Cloreto de Sódio/química , Água/química , Brasil , Ácidos Graxos Voláteis/análise , Íons/química , Limite de Detecção , Salinidade
3.
Chemosphere ; 71(4): 677-84, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18082244

RESUMO

In this work, 24-h PM10 samples were collected in Rio de Janeiro, Brazil, and analysed for trace elements (Cd, Ce, Cu, La, Mo, Ni, Pb, Pd, Rh, Sb and Sn). The sampling was carried out at five locations (Bonsucesso; Centro, downtown city; Copacabana; Nova Iguaçu and Sumaré) with different traffic densities and anthropogenic activities. An analytical method based on the EPA method for the determination of trace elements in airborne particulate matter (PM), using ultrasonic-assisted extraction and inductively coupled plasma mass spectrometry (ICP-MS) was applied. Our results suggest that vehicular traffic is the most important source of environmental pollution at the studied sites. The presence of Mo, Pd and Rh in the analysed filters reflects an additional source of pollution caused by the erosion and deterioration of automotive catalytic converters.


Assuntos
Poluição do Ar/análise , Atmosfera/química , Automóveis , Cidades , Brasil , Análise por Conglomerados , Filtração , Isótopos , Metais Pesados/análise , Metais Pesados/química , Material Particulado/análise , Material Particulado/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA