1.
J Pediatr ; 167(2): 312-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26003996

RESUMO

OBJECTIVE: To evaluate effects of holding parenteral nutrition (PN) for 3 hours prior to newborn screening (NBS) on false-positive NBS rate for amino acids (AAs) in very low birth weight (VLBW) infants (birth weight <1500 g). STUDY DESIGN: We analyzed data from 12 567 consecutive births in 1 hospital between May 2010 and June 2013. VLBW infants were stratified into 3 groups: (1) infants without PN before NBS (no-PN group); (2) infants with early PN running at the time of NBS (early-PN group); and (3) infants with early-PN that were temporarily replaced by dextrose-containing intravenous fluid 3 hours prior to NBS (stop-PN group). We compared the false-positive rate for AA and cost effectiveness between the groups. RESULTS: The false-positive rate for AA among 413 VLBW infants was significantly higher than infants with birth weight >1500 g (7.62% vs 0.05%; P < .001). There were no false-positive results for AA in the no-PN group. The false-positive rate for AA in the stop-PN group (2/65) was significantly lower than the early-PN group (29/245) (3.1% vs 11.8%; P = .037). The stop-PN group was more cost effective than early-PN group, saving $17.27 per infant screened ($5.53 vs $22.80) or $192.54 for each false-positive result for AA averted. Further reductions in inconclusive samples were also noted. CONCLUSIONS: VLBW and early-PN are significant factors for false-positive results for AA. Holding PN containing AAs for 3 hours before NBS collection is a practical and cost-effective method to significantly reduce the false-positive rate for AA in VLBW infants.


Assuntos
Aminoácidos/sangue , Triagem Neonatal/métodos , Nutrição Parenteral/métodos , Estudos de Coortes , Reações Falso-Positivas , Feminino , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo
2.
J Pediatr ; 144(3): 291-5, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15001929

RESUMO

OBJECTIVE: Correlate the ventilatory response of preterm infants to hypoxic exposure with incidence of neonatal apnea. Study design Seventeen stable convalescing premature infants underwent bedside cardiorespiratory monitoring of respiration using respiratory inductance plethysmography, heart rate, and oxygen saturation (SaO(2)) for a 12-hour period. These studies were scored for number of apneas > or =15 and > or =20 seconds. Infants then underwent a 3-minute hypoxic exposure. Minute ventilation (V(E)) was calculated for 30-second epochs from the time inspired oxygen reached 15%. Linear regression analysis was used to correlate the change in V(E) normalized for decrease in SaO(2) (DeltaV(E)/DeltaSaO(2)) during the first and third minutes of hypoxic exposure with the number of apneic episodes during the 12-hour study. RESULTS: The majority of infants exhibited an anticipated biphasic ventilatory response to hypoxia. There was a significant positive correlation between DeltaV(E)/DeltaSaO(2) during the first and third minutes of hypoxic exposure and number of apneic episodes > or =15 and > or =20 seconds during the preceding 12 hours. CONCLUSIONS: Preterm infants with a greater number of apneic episodes exhibit an increased ventilatory response to hypoxic exposure, suggesting that apnea of prematurity may be associated with enhanced peripheral chemoreceptor activity.


Assuntos
Apneia/fisiopatologia , Hipóxia/fisiopatologia , Recém-Nascido Prematuro , Respiração , Feminino , Humanos , Recém-Nascido , Modelos Lineares , Masculino , Pletismografia