Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Clin Oral Investig ; 28(7): 401, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940883

RESUMO

OBJECTIVES: This study aimed to assess whether awake bruxism and masticatory muscle activity could be related to external root resorption (ERR) in second molars adjacent to impacted mandibular third molars. MATERIALS AND METHODS: Sixty patients, with requests for a cone-beam, computed tomography, were divided into two groups: ERR (patients with ERR in the second molar, n = 30), and control group (n = 30). Awake bruxism was assessed through the Oral Behaviors Checklist (OBC) and an ecological momentary assessment (EMA). Surface electromyography (EMG) was used to assess the masseter and anterior temporal muscle function. Normality and homogeneity of variances were demonstrated. Descriptive analysis was performed, using the T-test and Chi-square test to compare the characteristics of the groups. A multiple regression model was performed. RESULTS: The ERR group presented more non-functional oral activities related to awake bruxism than the control group, according to OBC (p = 0.027) and EMA (p = 0.035). In addition, the ERR group had higher EMG activity than the control group in rest and isotonic protocols (p < 0.05). CONCLUSIONS: Awake bruxism and greater masticatory muscle activity seem to be related to the presence of ERR in second molars adjacent to impacted mandibular third molars. CLINICAL RELEVANCE: The results of the present study can reinforce the theory that triggering ERR in the second molars adjacent to impacted mandibular third molars may be related to mechanical forces coming from the masticatory function.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Eletromiografia , Dente Serotino , Reabsorção da Raiz , Dente Impactado , Humanos , Dente Serotino/diagnóstico por imagem , Dente Serotino/fisiopatologia , Feminino , Masculino , Dente Impactado/fisiopatologia , Dente Impactado/diagnóstico por imagem , Adulto , Reabsorção da Raiz/fisiopatologia , Reabsorção da Raiz/diagnóstico por imagem , Dente Molar/fisiopatologia , Bruxismo/fisiopatologia , Músculos da Mastigação/fisiopatologia , Mandíbula/fisiopatologia , Mandíbula/diagnóstico por imagem
2.
J Clin Exp Dent ; 14(7): e534-e540, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35912024

RESUMO

Background: The mandibular incisive canal (MIC) is an anatomic structure to be considered in treatment planning for surgeries in the anterior region of the mandible. Awareness of the MIC increased with the use of 3D imaging for treatment planning, such as cone beam computed tomography (CBCT). This study aimed to use CBCT to assess the prevalence, morphology and position of the MIC among North-Brazilians. Material and Methods: The sample consisted of CBCT scans of 100 hemi-mandibles (50 individuals) that were assessed for the absolute (n) and relative frequency of the MIC. The morphological component of this study was the diameter (mm) of the detected MIC in five anatomic sites between the mental foramen and the midline. Within the interformainal region, the position of the MIC was assessed by measuring (mm) the distances between the MIC and the basal, vestibular and lingual cortical bone surfaces. Results: The prevalence of the MIC was >76% considering the different anatomic regions screened in CBCT. The mean diameter of the MIC progressively reduced from 1.29 mm to 0.86 throughout the five anatomic regions measured. The position of the MIC showed a downward trajectory away from the lingual cortical bone surface. Conclusions: MIC was a highly prevalent anatomic structure in the studied sample. The funnel-shaped outline of the MIC and its trajectory into the interforaminal region highlighted a major risk of damage to the neurovascular bundle in surgeries (e.g. implant placement) that are close to the mental foramen and the vestibular cortical bone. Key words:Anatomy, cone beam computed tomography, imaging, mandibular incisive canal, oral radiology.

3.
Braz Dent J ; 33(4): 31-39, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36043566

RESUMO

This study evaluated the centralization of the region of interest (ROI) in acquisition of the CBCT images, when the freely positionable scout-view (SV) function is applied. Additionally, the dosimetry of the acquired images was assessed in the SV function alone as well as in complete tomographic image in two different fields of view (FOV) (50x50 and 78x150mm). A three-location device was created to accommodate the dosimeters and the specimens, in the right, middle and left location during image acquisition. For dose assessment, thermoluminescent dosimeters were irradiated within the FOV and analyzed in a portable reader. For ROI evaluation, three specimens of gutta-percha stick were placed on the same device and the CT scans were acquired (CBCT OP 300 Maxio device, 90kV, 13mA, 85 µm voxel size, FOV of 50X50mm), with and without the SV, in three positions (3-9, 1-7 and 5-11 o'clock), simulating different regions of the mouth. Two image evaluations were performed, an objective and subjective. There was a slight percentage increase (1.36% to 1.40%) of the radiation dose with the use of SV. The distances were significantly greater in the images acquired without SV (p < 0.05). Every image obtained with SV was classified as being at the FOV's center. In conclusion, the results demonstrated that SVs function is effective to centralize the ROI in the FOV, increasing the scan precision and avoiding repetitions due to positioning errors.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico/métodos , Guta-Percha , Imagens de Fantasmas , Doses de Radiação , Dosimetria Termoluminescente
4.
Braz. dent. j ; 33(4): 31-39, July-Aug. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1394088

RESUMO

Abstract This study evaluated the centralization of the region of interest (ROI) in acquisition of the CBCT images, when the freely positionable scout-view (SV) function is applied. Additionally, the dosimetry of the acquired images was assessed in the SV function alone as well as in complete tomographic image in two different fields of view (FOV) (50x50 and 78x150mm). A three-location device was created to accommodate the dosimeters and the specimens, in the right, middle and left location during image acquisition. For dose assessment, thermoluminescent dosimeters were irradiated within the FOV and analyzed in a portable reader. For ROI evaluation, three specimens of gutta-percha stick were placed on the same device and the CT scans were acquired (CBCT OP 300 Maxio device, 90kV, 13mA, 85 µm voxel size, FOV of 50X50mm), with and without the SV, in three positions (3-9, 1-7 and 5-11 o'clock), simulating different regions of the mouth. Two image evaluations were performed, an objective and subjective. There was a slight percentage increase (1.36% to 1.40%) of the radiation dose with the use of SV. The distances were significantly greater in the images acquired without SV (p < 0.05). Every image obtained with SV was classified as being at the FOV's center. In conclusion, the results demonstrated that SVs function is effective to centralize the ROI in the FOV, increasing the scan precision and avoiding repetitions due to positioning errors.


Resumo Este estudo avaliou a centralização da região de interesse (ROI) na aquisição das imagens de TCFC, quando a função scout-view (SV) posicionável livremente é aplicada. Adicionalmente, a dosimetria das imagens adquiridas foi avaliada isoladamente na presença da função SV, bem como após aquisição de imagem tomográfica completa em dois diferentes campos de visão (FOV) (50x50 e 78x150mm). Um dispositivo de três localizações foi criado para acomodar os dosímetros e os espécimes, na localização direita, central e esquerda, durante a aquisição das imagens. Para avaliação da dose, dosímetros termoluminescentes foram irradiados dentro dos campos de visão e analisados em leitor portátil. Para avaliação da ROI, três espécimes de guta percha foram colocados no mesmo aparelho e as tomografias foram adquiridas (CBCT OP 300 Maxio, 90kV, 13mA, 85 μm tamanho de voxel, FOV de 50X50mm), com e sem a SV, em três posições (3-9, 1-7 e 5-11 horas), simulando diferentes regiões da boca. Foram realizadas duas avaliações de imagem, uma objetiva e outra subjetiva. Houve um leve aumento percentual (1,36% para 1,40%) da dose de radiação com o uso de SV. As distâncias foram significativamente maiores nas imagens adquiridas sem SV (p < 0,05). Todas as imagens obtidas com SV foram classificadas como sendo do centro do FOV. Em conclusão, os resultados do presente estudo demonstraram que a função scout view é eficaz para centralizar a ROI no FOV, aumentando a precisão do escaneamento e evitando repetições devido a erros de posicionamento.

5.
Int J Legal Med ; 136(5): 1507-1514, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35708869

RESUMO

International guidelines for dental age assessment have recommended the use of methods based on available population-specific data. The Third Molar Maturity Index (I3M) was previously validated in several populations worldwide. This was the first study to evaluate the I3M in a northern Brazilian population and to test the diagnostic accuracy of the method to distinguish between minors and adults. The sample consisted of 1.070 panoramic radiographs retrospectively collected from females (n = 595) and males (n = 475) with ages between 16 and 22 years. I3M's original cut-off value of 0.08 was used to classify individuals below and above the age of 18. Receiver operating characteristic (ROC) curves were plotted to assess the accuracy (ACC) of the method. In females and males separately, the overall ACC was 73.1% and 80%, respectively. The overall ACC for the combined sample was 76.1%. For northern Brazilian males, the best cut-off value remained 0.08, while for females, an adjustment to 0.12 showed optimal outcomes. The new cut-off value led to an ACC of 98.5% for females, which reflected an increase of 25.5% compared to the original cut-off value. The original cut-off value proposed by I3M was applicable to the present sample of northern Brazilian individuals. Adjustments to 0.12, however, may be encouraged to enhance the performance of the method among females.


Assuntos
Determinação da Idade pelos Dentes , Dente Serotino , Adolescente , Adulto , Determinação da Idade pelos Dentes/métodos , Brasil , Feminino , Humanos , Masculino , Dente Serotino/diagnóstico por imagem , Radiografia Panorâmica , Estudos Retrospectivos , Adulto Jovem
6.
Rev. Bras. Odontol. Leg. RBOL ; 7(1): [4,16], jan-abril 2020.
Artigo em Português | LILACS | ID: biblio-1147647

RESUMO

A restrição à publicidade odontológica coíbe a mercantilização, resguarda a privacidade do paciente e o protege como consumidor. O objetivo deste estudo foi avaliar a adequação da publicidade na rede Instagram® ao regramento vigente. Numa amostra de 384 perfis profissionais, avaliaram-se postagens públicas à luz da Lei 5.081/1966, Código de Defesa do Consumidor e Código de Ética Odontológica. A identificação adequada não foi feita por 35,4%. Já 3,6% anunciaram especialidades não reconhecidas. A expressão "popular" foi utilizada por 27,1%. Houve publicidade abusiva (16,4%) ou enganosa (8,3%). Serviços gratuitos foram anunciados (9,4%), com divulgação de preços (5,5%). Usando a imagem do paciente (79,4%), constatou-se divulgação de resultados clínicos (72,9%). Houve identificação do paciente em 68,2%, com uso adequado da imagem em apenas 9,1% dos casos. As imagens de antes/depois foram usadas em 76,6% das postagens. As inadequações sem a imagem do paciente orbitam entre infração ética, exercício profissional ilícito e desrespeito ao direito consumerista. Conclui-se que a publicidade odontológica veiculada no Instagram® apresentou condutas ilícitas e antiéticas, com e sem o uso da imagem do paciente o que pode configurar prejuízos ao paciente, ao profissional e à Odontologia como profissão da área de saúde.


Assuntos
Humanos , Masculino , Feminino , Defesa do Consumidor , Publicidade Direta ao Consumidor , Odontologia Legal
7.
Dentomaxillofac Radiol ; 47(1): 20170198, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28871830

RESUMO

OBJECTIVES: To compare the performance of panoramic radiography (PAN) and cone beam CT (CBCT) in the detection of juxta-apical radiolucency (JAR), as well as to investigate, in CBCT images, if there are factors associated with the detection of JAR on PAN. METHODS: Two oral radiologists assessed the presence of JAR in PAN and CBCT images of 175 individuals (308 mandibular third molars). The cortical plates involvement and the JAR size and location were assessed on CBCT to evaluate if these factors were related to JAR detection on PAN. McNemar's test and multiple logistic regression were performed. RESULTS: PAN and CBCT differed significantly in the detection of JAR (p = 0.001). On PAN, JAR was identified on 24% of the patients while on CBCT its detection increased to 32.6%. JAR was detected only on CBCT and only on PAN in 26 and 7 cases, respectively. Distal/mesial surfaces of dental roots were where JAR was mostly located (84.5%), cortical thinning was found in 59.2% of cases and the mean (SD) of JAR size was 5.03 (±1.8) mm. However, these factors were not associated with JAR detection on PAN (p > 0.05). On the other hand, the location of the cortical involvement (if buccal or lingual) was associated with JAR detection on PAN, which was more detectable when the thinning was on buccal cortical. CONCLUSIONS: Juxta-apical radiolucency is more often detected on CBCT than on PAN. JAR detection on PAN was improved when it was related to the buccal cortical plate of the mandible.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mandíbula/diagnóstico por imagem , Dente Serotino/diagnóstico por imagem , Radiografia Panorâmica , Dente Impactado/diagnóstico por imagem , Adolescente , Adulto , Feminino , Humanos , Masculino
8.
RGO (Porto Alegre) ; 62(2): 169-172, Apr-Jun/2014. graf
Artigo em Inglês | LILACS | ID: lil-725600

RESUMO

This case report has the aim to present an adhesion of the temporomadibular disc to the articular eminence, diagnosed on magnetic resonance imaging images. A 37-year-old female patient with TMJ (temporomandibular joint) disk adhesion on the left side and complaining of bilateral otalgia over the last 2 years is reported in the present article. The patient did not complain of articular pain or clicking, or any other noises of any nature. Clinical observation showed that the patient had restricted jaw opening, with mandibular deviation the left side without correction during mandibular movement. Our diagnostic impression was of partial anterior disk displacement with reduction of the right side disc; and partial anterior disk displacement with reduction and disc disk adhesion with hypo-mobility of the condyle, on the left temporomandibular joint. The peculiarity of this reported case is the fact that besides the bilateral partial anterior disc displacement, there was also found an adhesion of the disc on the left side. In conclusion, the magnetic resonance imaging exam of the temporomandibular joint can be considered an exam of choice for the evaluation of disc positioning and its morphological alterations.


Este trabalho tem como objetivo apresentar um caso clínico de adesão do disco da articulação temporomandibular à eminência articular, diagnosticada através da ressonância magnética. Paciente de 37 anos de idade, sexo feminino, com queixa de crises ocasionais de otalgia bilateral, ao longo dos últimos 2 anos. A paciente não referia dor ou ruídos articulares de qualquer natureza. Clinicamente, apresentava limitação de abertura de boca, com desvio à esquerda sem correção da trajetória ao final do movimento mandibular. A impressão diagnóstica foi de deslocamento anterior parcial, com redução, do disco articular direito; e, para o lado esquerdo, deslocamento anterior parcial, com redução, e adesão do disco articular ao componente temporal, com hipomobilidade do côndilo. A particularidade do caso descrito está justamente no fato de que além do deslocamento parcial anterior, bilateral, existia, também, uma adesão do disco no lado esquerdo. Conclui-se que o exame de ressonância magnética da articulação temporomandibular pode ser considerado o método de escolha para avaliação do posicionamento do disco articular e suas alterações morfológicas.

9.
Braz. j. oral sci ; 13(2): 104-108, Apr-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-715611

RESUMO

AIM: To assess which slice inclination would be more accurate in measuring sites for implant placement: the oblique or the orthoradial slice. METHODS: Five regions of eight edentulous mandibles were selected (incisor, canine, premolar, first molar and second molar). The mandibles were scanned with a Next Generation i-CAT CBCT unit. Two previously calibrated oral radiologists performed vertical measurements in all the selected regions using both the oblique and orthoradial slices. The mandibles were sectioned in all the evaluated regions in order to obtain the gold standard. The Wilcoxon signed rank test compared the measurements obtained in the oblique and orthoradial slices with the gold standard. RESULTS: The bone height measurements for the first and second molar regions using the orthoradial slices were statistically different from the gold standard. CONCLUSIONS: Using the orthoradial slices to obtain cross-sectional images may offer insufficient accuracy for implant placement in the posterior region...


Assuntos
Implantes Dentários , Mandíbula , Tomografia Computadorizada de Feixe Cônico/métodos
10.
Dent Traumatol ; 29(6): 489-93, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22804823

RESUMO

Horizontal root fractures (HRF) usually affect anterior teeth of male patients as a result of trauma. The consequences can be complex because of combined damage to different tissues, but it has been reported that root fractures undergo healing in majority cases. Diagnosis of HRF must be based on clinical findings, sensibility tests, and radiographic examination. The cone-beam computed tomography (CBCT) has already been proven to be superior among other radiographic modalities for diagnostic imaging of root fractures. However, CBCT in these cases needs to be used in a careful manner, and only when the radiation exposure should be justified by the potential diagnostic benefits and improvement of the treatment results. This case report describes a case of spontaneously healed horizontal root fracture with displacement of the fragments and discusses the usefulness of CBCT in the follow-up of root fractures cases.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Feminino , Humanos , Raiz Dentária/lesões , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA