Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Braz Dent J ; 35: e245632, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537016

RESUMO

This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values ​​at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values ​​in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.


Assuntos
Implantes Dentários , Humanos , Planejamento de Prótese Dentária , Boca , Face , Torque , Implantação Dentária Endóssea/métodos
2.
Clin Oral Implants Res ; 35(4): 359-376, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38315151

RESUMO

BACKGROUND: The aim of this systematic review and network meta-analysis (NMA) was to assess the efficacy of different wound-healing agents for palatal donor area management after soft tissue graft harvesting. METHODS: Electronic searches in six databases were conducted for publications up to October 2023. Studies with data from patients undergoing therapeutic approaches using agents for palatal healing after gingival graft harvesting were included. Data about postoperative pain, wound-healing and postoperative complications reported for each agent were extracted. Three different tools were used for the risk of bias within studies evaluation (Murad tool for case series and case report, RoB 2.0 tool for randomized studies and ROBINS-I tool for non-randomized studies). A Bayesian random effects NMA was conducted for postoperative pain levels and wound healing. RESULTS: Eighty-four publications were included in the systematic review (qualitative analysis), with 14 of these subjected to NMA (quantitative analysis). The summarized results from the qualitative and quantitative analysis showed that all wound-healing agents evaluated promoted better pain control and wound healing compared to spontaneous healing and hemostatic sponges alone. The NMA outcomes reveal that leucocyte- and platelet-rich fibrin (L-PRF) was the most effective agent in reducing postoperative pain in all analyzed periods. Moreover, the L-PRF seems to accelerate wound healing and reduce postoperative complications compared to other agents. CONCLUSION: In conclusion, the L-PRF was the most effective agent in reducing postoperative pain, accelerating wound healing and reducing postoperative complications after harvesting soft tissue grafts from the palatal area.


Assuntos
Metanálise em Rede , Dor Pós-Operatória , Palato , Cicatrização , Humanos , Cicatrização/efeitos dos fármacos , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Palato/cirurgia , Fibrina Rica em Plaquetas , Complicações Pós-Operatórias/prevenção & controle , Coleta de Tecidos e Órgãos/métodos , Coleta de Tecidos e Órgãos/efeitos adversos , Gengiva/transplante
3.
Braz. j. oral sci ; 23: e243937, 2024. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1555183

RESUMO

Aim: This study was performed to compare two different rat defect models (critical calvaria defects versus guided bone regeneration in the mandibular ramus) used to evaluate bone repair in grafted areas. Methods: A total of 12 rats were allocated in two groups according the experimental model used to evaluate the bone repair in grafted areas: a critical sized-calvaria defect of 5 mm filled with bone graft (n=6) and a mandibular ramus filled with the bone graft associated with a Teflon dome-shaped membrane (n=6). Both groups were grafted with deproteinized bovine bone graft. After 60 days, the animals were euthanized and the samples obtained were submitted to histomorphometry analysis to evaluate the relative amount of bone, remaining bone substitute, and soft tissue within the grafted areas. Results: No differences were observed between the preclinical models evaluated in relation to the amount of bone tissue formation (19.93 ± 4.55% in calvaria vs. 21.00 ± 8.20% in mandible). However, there was a smaller amount of soft tissue (43.20 ± 10.97% vs. 57.79 ± 7.61 %; p<0.01) and a greater amount of bone substitute remaining (35.80 ± 5.52% vs. 22.28 ± 4.36 %; p<0.05) in the grafted areas in the mandible compared to calvaria defect. Conclusion: Preclinical models for the analysis of bone repair in grafted areas in the mandible and critical sized-calvaria defects showed different responses in relation to the amount of soft tissue and bone substitute remnants


Assuntos
Animais , Ratos , Regeneração Óssea , Substitutos Ósseos , Experimentação Animal , Histologia
4.
Rev. odontol. UNESP (Online) ; 53: e20240001, 2024. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1560340

RESUMO

Abstract Introduction The maintenance of oral health in inpatients is essential, particularly to avoid complications arising from periodontal disease, which not only affect oral health but can also exacerbate systemic issues during hospitalization. Objective: This study aimed to assess nursing staff's knowledge regarding the management of periodontal disease and its association with systemic diseases. Material and method This cross-sectional observational study was conducted in a general referral hospital of the Brazilian National Health System (SUS). A total of 504 nursing professionals completed a self-administered 24-item questionnaire on relating to oral care procedures and the importance of oral health in hospitalized patients. Data were analyzed using descriptive analysis and the chi-squared test (α = 0.05). Result Most respondents (97.8%) believed that oral infections can affect a patient's general health and that oral hygiene is important during hospitalization. However, knowledge deficits were identified. The oral effect of periodontal disease was considered moderate by 49.3% of the participants, and 74.6% believed that sugar was the most common cause of periodontal disease. Conclusion Nursing professionals are aware of the importance of maintaining oral hygiene and the relationship between periodontal and systemic diseases. However, their dental hygiene practice knowledge is limited. A training program on oral healthcare for inpatients and the inclusion of oral hygiene topics in the curricula of nursing professionals are recommended.


Resumo Introdução A manutenção da saúde bucal em pacientes internados é essencial, especialmente para evitar complicações decorrentes da doença periodontal, que não apenas afetam a saúde bucal, mas também podem agravar problemas sistêmicos durante a hospitalização. Objetivo: Este estudo teve como objetivo avaliar o conhecimento da equipe de enfermagem em relação ao manejo da doença periodontal e sua associação com doenças sistêmicas. Material e método Este estudo observacional transversal foi conduzido em um hospital geral de referência do Sistema Único de Saúde (SUS) do Brasil. Um total de 504 profissionais de enfermagem completaram um questionário autoaplicável com 24 questões, abordando procedimentos de cuidados bucais e a importância da saúde bucal em pacientes hospitalizados. Os dados foram analisados por meio de análise descritiva e teste qui-quadrado (α = 0,05). Resultado A maioria dos entrevistados (97,8%) acreditava que infecções bucais podem afetar a saúde geral do paciente e que a higiene bucal é importante durante a hospitalização. No entanto, foram identificados déficits de conhecimento. O efeito oral da doença periodontal foi considerado moderado por 49,3% dos participantes, e 74,6% acreditavam que o açúcar era a causa mais comum da doença periodontal. Conclusão Profissionais de enfermagem reconhecem a importância da manutenção da higiene bucal e a relação entre doença periodontal e doenças sistêmicas. No entanto, seu conhecimento prático em higiene bucal é limitado. Recomenda-se um programa de treinamento em cuidados bucais para pacientes internados e a inclusão de tópicos de higiene bucal nos currículos dos profissionais de enfermagem.

5.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1550093

RESUMO

Abstract This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values ​​at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values ​​in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.


Resumo O objetivo deste estudo controlado randomizado de boca dividida foi avaliar a estabilidade primária e secundária de implantes híbridos com diferentes configurações de rosca e superfícies hidrofílicas. Vinte pacientes com maxila parcialmente edêntula foram selecionados. Esses pacientes receberam dois tipos de implantes com a mesma superfície hidrofílica: Grupo CTP: Implante cilíndrico-cônico com roscas perfurantes; Grupo CTH: Implante cilíndrico-cônico com roscas perfurantes e condensadoras. Os parâmetros de estabilidade primária e secundária foram medidos por análise de torque de inserção e frequência de ressonância no momento da colocação do implante e 7, 28, 56 e 90 dias após o procedimento cirúrgico. O teste t-pareado foi utilizado para comparação dos dados de estabilidade entre os grupos. A análise estatística foi executada levando-se em consideração um nível de confiança de 95%. Constatou-se que os implantes do grupo CTH apresentaram maiores valores de estabilidade primária no momento da colocação do implante, devido ao maior ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) e torque de inserção (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), do que os implantes do grupo CTP. Implantes do grupo CTH apresentaram valores de ISQ superiores em todos os períodos de acompanhamento: 7 dias (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 dias (68.61 ± 5.98 vs. 47.90 ±13.10), 56 dias (74.09 ± 3.96 vs. 55.85 ± 13.18) e 90 dias (75.45 ± 4.02 vs. 63.47 ± 6.92). Os implantes híbridos com roscas perfurantes e condensantes demonstraram maior estabilidade do que os implantes híbridos com apenas roscas perfurantes.

6.
Braz. dent. sci ; 27(2): 1-10, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1567454

RESUMO

Objective: This study evaluated the use of autogenous blood concentrate (injectable platelet-rich fibrin) [i-PRF] for promoting soft tissue healing in osteoradionecrosis (ORN) lesions in patients who underwent head and neck radiotherapy. Material and Methods: This study included five ORN lesions in four patients who were treated with i-PRF (applied weekly for 4 weeks to the lesions). Soft tissue features were evaluated through clinical analysis at baseline and at 7, 15, 30, 60, and 90 days after the first session of i-PRF. Extension of the bone lesions was evaluated radiographically. Patient-centered related outcomes were evaluated using quality-of-life questionnaires at baseline and 90 days after the first treatment session. Quality of life data were analyzed using descriptive and frequency statistics and the Wilcoxon test. Results: Of the 5 treated lesions, 1 was completely closed and 3 remained open. The open lesions showed increased necrotic tissue exposure. No changes were observed in the radiographic appearance of the lesions. There was also no impact on the patient's quality of life. Conclusion: The results suggest that the majority of ORN lesions remained stable after the application of i-PRF, with a slight improvement in the quality of the mucosa around the lesions. Furthermore, it was observed that i-PRF did not compromise the quality of life of patients during treatment.(AU)


Objetivo: Este estudo avaliou o uso de concentrado de sangue autógeno (fibrina rica em plaquetas injetável) [i-PRF] para promover a cicatrização de tecidos moles em lesões de osteorradionecrose (ORN) em pacientes submetidos a radioterapia de cabeça e pescoço. Material e Métodos: Este estudo incluiu cinco lesões de ORN em quatro pacientes tratados com i-PRF (aplicado semanalmente por 4 semanas nas lesões). As características do tecido mole foram avaliadas por meio de análises clínicas no início e aos 7, 15, 30, 60 e 90 dias após a primeira sessão de i-PRF. A extensão das lesões ósseas foi avaliada radiograficamente. Os resultados centrados no paciente foram avaliados usando questionários de qualidade de vida no início e 90 dias após a primeira sessão de tratamento. Os dados de qualidade de vida foram analisados usando estatísticas descritivas e de frequência, além do teste de Wilcoxon. Resultados: Das 5 lesões tratadas, 1 foi completamente fechada e 3 permaneceram abertas. As lesões abertas mostraram aumento na exposição de tecido necrótico. Não foram observadas mudanças na aparência radiográfica das lesões. Também não houve impacto na qualidade de vida do paciente. Conclusão: Os resultados sugerem que a maioria das lesões de ORN permaneceu estável após a aplicação de i-PRF, com uma discreta melhora na qualidade da mucosa ao redor das lesões. Além disso, observou-se que a i-PRF não comprometeu a qualidade de vida dos pacientes durante o tratamento.(AU)


Assuntos
Humanos , Osteorradionecrose , Qualidade de Vida , Radioterapia , Fibrina Rica em Plaquetas , Neoplasias de Cabeça e Pescoço
7.
Braz Dent J ; 34(5): 43-52, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38133472

RESUMO

This study evaluated the influence of a fluoride-modified titanium surface on osseointegration in rats with induced diabetes. One hundred and eighty rats were randomly allocated into 3 groups with 60 animals each: Control group (C): Animals without diabetes; Diabetes Group (D): Animals with uncontrolled induced diabetes; Controlled Diabetes Group (CD): Animals with diabetes induced controlled by the insulin administration. Diabetes was induced by streptozotocin injection. Each animal received 2 implants in the proximal tibial metaphysis, one with the machined surface (M) and the other one with a fluoride-modified titanium surface (F), after 4 weeks of induction of diabetes. The animals were submitted to euthanasia 2, 4, and 6 weeks after the implant placement (n = 20 animals/group). The osseointegration was evaluated by the implant removal torque test and the histometric analysis of the non-decalcified histological sections: 1) Contact bone/implant (%BIC); 2) Bone tissue area between implant threads (%BBT). Implants with F surface showed a higher removal torque than implants with surface M in all groups. There was no difference in %BIC between the groups regardless of the surface used. The F surface showed a tendency to present higher %BBT values for the 3 evaluation periods in the D group. The fluoride-modified implant surface has no impact on the %BIC and %BBT. However, the fluoride-modified implant surface increases the locking of the implants with the bone. The hyperglycemia was associated with lower removal torque values despite the surfaces of the implant used.


Assuntos
Implantes Dentários , Diabetes Mellitus , Ratos , Animais , Osseointegração , Fluoretos , Tíbia , Titânio , Propriedades de Superfície , Torque
8.
Braz. dent. j ; 34(5): 43-52, Sept.-Oct. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528014

RESUMO

Abstract This study evaluated the influence of a fluoride-modified titanium surface on osseointegration in rats with induced diabetes. One hundred and eighty rats were randomly allocated into 3 groups with 60 animals each: Control group (C): Animals without diabetes; Diabetes Group (D): Animals with uncontrolled induced diabetes; Controlled Diabetes Group (CD): Animals with diabetes induced controlled by the insulin administration. Diabetes was induced by streptozotocin injection. Each animal received 2 implants in the proximal tibial metaphysis, one with the machined surface (M) and the other one with a fluoride-modified titanium surface (F), after 4 weeks of induction of diabetes. The animals were submitted to euthanasia 2, 4, and 6 weeks after the implant placement (n = 20 animals/group). The osseointegration was evaluated by the implant removal torque test and the histometric analysis of the non-decalcified histological sections: 1) Contact bone/implant (%BIC); 2) Bone tissue area between implant threads (%BBT). Implants with F surface showed a higher removal torque than implants with surface M in all groups. There was no difference in %BIC between the groups regardless of the surface used. The F surface showed a tendency to present higher %BBT values for the 3 evaluation periods in the D group. The fluoride-modified implant surface has no impact on the %BIC and %BBT. However, the fluoride-modified implant surface increases the locking of the implants with the bone. The hyperglycemia was associated with lower removal torque values despite the surfaces of the implant used.


Resumo Este estudo avaliou a influência de uma superfície de titânio modificada com flúor na osseointegração em ratos com diabetes induzida. Cento e oitenta ratos foram distribuídos aleatoriamente em 3 grupos com 60 animais cada: Grupo controle (C): Animais sem diabetes; Grupo Diabetes (D): Animais com diabetes induzida descompensada; Grupo Diabetes Controlado (CD): Animais com diabetes induzido controlado pela administração de insulina. O diabetes foi induzido por injeção de estreptozotocina. Cada animal recebeu 2 implantes na metáfise proximal da tíbia, um com superfície usinada (M) e outro com superfície de titânio modificado com flúor (F), após 4 semanas de indução do diabetes. Os animais foram submetidos à eutanásia 2, 4 e 6 semanas após a colocação do implante (n = 20 animais/grupo). A osseointegração foi avaliada pelo teste de torque de remoção do implante e pela análise histométrica dos cortes histológicos não descalcificados: 1) Contato osso-implante (%BIC); 2) Área de tecido ósseo entre as roscas do implante (%BBT). Os implantes com superfície F apresentaram maior torque de remoção do que os implantes com superfície M em todos os grupos. Não houve diferença no %BIC entre os grupos independente da superfície utilizada. A superfície F mostrou tendência a apresentar maiores valores de %BBT para os 3 períodos de avaliação no grupo D. As superfícies de implantes modificadas com flúor não influenciaram nos dados de %BIC e %BBT. Entretanto, essas superfícies aumentaram o travamento dos implantes no tecido ósseo. A hiperglicemia foi associada a menores torques de remoção dos implantes independentemente do tipo de superfície de implante utilizada.

9.
Healthcare (Basel) ; 11(18)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37761669

RESUMO

This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations. After osseointegration, an intraoral scanning transfer provided a digital model (file extension .stl), which reproduced the implant's position and inclination. Then, the file was sent so that a customized abutment (CAD/CAM) could be manufactured, promoting the final rehabilitation of the case; this allowed for good hygiene, load distribution in the dynamic interocclusal relationship, and favorable esthetics, whereas many would otherwise recommend implant removal. The result presented lower costs, a shorter time frame, and a lower morbidity for the patient.

10.
Braz Dent J ; 34(3): 66-72, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37466527

RESUMO

The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of non-decalcified histological sections and evaluation of the bone implant contact (% BIC) as well as the fraction of bone tissue area between the implant threads (% BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.85% vs. 29.49 ± 10.27%) and % BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface.


Assuntos
Implantes Dentários , Osseointegração , Animais , Coelhos , Propriedades de Superfície , Interações Hidrofóbicas e Hidrofílicas , Osso e Ossos , Titânio , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA