Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Clin Ophthalmol ; 18: 1691-1699, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38863678

RESUMO

Purpose: To assess ocular pain in patients undergoing multiple intravitreal injections of anti-vascular endothelial growth factor (anti-VEGF) who have previous factors that may influence pain sensitivity. Methodology: This is a prospective, observational, case series study involving patients who underwent multiple (≥3) pro re nata intravitreal injections of ranibizumab or aflibercept to treat any cause of chorioretinal vascular disease. Ocular pain was assessed by the numerical analog scale during intravitreal injection. For this study, the main variable was ocular pain and the secondary variables included age, sex, previous history of glaucoma, primary retinal vascular disease, severe dry eye history, trigeminal pain, scleral buckle surgery, collagen diseases, fibromyalgia, severe migraine history, pars plana vitrectomy, scleral thickness measurements, and type of anti-VEGF. Results: In a total of 894 patients, 948 eyes (4822 intravitreal injections), 793 patients (88.6%) had ocular pain sensitivity between no pain to mild pain, 80 patients (8.9%) had moderate ocular pain, 15 patients (1.6%) had severe ocular pain, and 6 patients (0.7%) had extremely severe ocular pain. Patients with severe dry eye (p = 0.01) and previous history of scleral buckle surgery (p = 0.01) showed a significant correlation with ocular pain during intravitreal injection. Pars plana scleral thickness (>550 um) and diabetic neuropathy were associated with ocular pain but did not meet the criteria for statistical significance (p = 0.09 and p = 0.06, respectively). Conclusion: Dry eye and prior scleral buckle surgery may contribute to pain associated with intravitreal injection. These issues should be taken into consideration in patients undergoing multiple intravitreal injections.

2.
Int J Retina Vitreous ; 10(1): 43, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38877585

RESUMO

BACKGROUND: Diabetic retinopathy (DR) stands as the foremost cause of preventable blindness in adults. Despite efforts to expand DR screening coverage in the Brazilian public healthcare system, challenges persist due to various factors including social, medical, and financial constraints. Our objective was to evaluate the quality of images obtained with the AirDoc, a novel device, compared to Eyer portable camera which has already been clinically validated. METHODS: Images were captured by two portable retinal devices: AirDoc and Eyer. The included patients had their fundus images obtained in a screening program conducted in Blumenau, Santa Catarina. Two retina specialists independently assessed image's quality. A comparison was performed between both devices regarding image quality and the presence of artifacts. RESULTS: The analysis included 129 patients (mean age of 61 years), with 29 (43.28%) male and an average disease duration of 11.1 ± 8 years. In Ardoc, 21 (16.28%) images were classified as poor quality, with 88 (68%) presenting artifacts; in Eyer, 4 (3.1%) images were classified as poor quality, with 94 (72.87%) presenting artifacts. CONCLUSIONS: Although both Eyer and AirDoc devices show potential as screening tools, the AirDoc images displayed higher rates of ungradable and low-quality images, that may directly affect the DR and DME grading. We must acknowledge the limitations of our study, including the relatively small sample size. Therefore, the interpretations of our analyses should be approached with caution, and further investigations with larger patient cohorts are warranted to validate our findings.

3.
Acta Diabetol ; 60(8): 1075-1081, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37149834

RESUMO

AIMS: This study aims to compare the performance of a handheld fundus camera (Eyer) and standard tabletop fundus cameras (Visucam 500, Visucam 540, and Canon CR-2) for diabetic retinopathy and diabetic macular edema screening. METHODS: This was a multicenter, cross-sectional study that included images from 327 individuals with diabetes. The participants underwent pharmacological mydriasis and fundus photography in two fields (macula and optic disk centered) with both strategies. All images were acquired by trained healthcare professionals, de-identified, and graded independently by two masked ophthalmologists, with a third senior ophthalmologist adjudicating in discordant cases. The International Classification of Diabetic Retinopathy was used for grading, and demographic data, diabetic retinopathy classification, artifacts, and image quality were compared between devices. The tabletop senior ophthalmologist adjudication label was used as the ground truth for comparative analysis. A univariate and stepwise multivariate logistic regression was performed to determine the relationship of each independent factor in referable diabetic retinopathy. RESULTS: The mean age of participants was 57.03 years (SD 16.82, 9-90 years), and the mean duration of diabetes was 16.35 years (SD 9.69, 1-60 years). Age (P = .005), diabetes duration (P = .004), body mass index (P = .005), and hypertension (P < .001) were statistically different between referable and non-referable patients. Multivariate logistic regression analysis revealed a positive association between male sex (OR 1.687) and hypertension (OR 3.603) with referable diabetic retinopathy. The agreement between devices for diabetic retinopathy classification was 73.18%, with a weighted kappa of 0.808 (almost perfect). The agreement for macular edema was 88.48%, with a kappa of 0.809 (almost perfect). For referable diabetic retinopathy, the agreement was 85.88%, with a kappa of 0.716 (substantial), sensitivity of 0.906, and specificity of 0.808. As for image quality, 84.02% of tabletop fundus camera images were gradable and 85.31% of the Eyer images were gradable. CONCLUSIONS: Our study shows that the handheld retinal camera Eyer performed comparably to standard tabletop fundus cameras for diabetic retinopathy and macular edema screening. The high agreement with tabletop devices, portability, and low costs makes the handheld retinal camera a promising tool for increasing coverage of diabetic retinopathy screening programs, particularly in low-income countries. Early diagnosis and treatment have the potential to prevent avoidable blindness, and the present validation study brings evidence that supports its contribution to diabetic retinopathy early diagnosis and treatment.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Edema Macular , Humanos , Masculino , Pessoa de Meia-Idade , Retinopatia Diabética/diagnóstico , Edema Macular/diagnóstico , Edema Macular/etiologia , Smartphone , Estudos Transversais , Retina , Programas de Rastreamento/métodos
4.
Rev. méd. Minas Gerais ; 19(4,supl.3): S64-S68, out.-dez. 2009. ilus
Artigo em Português | LILACS | ID: lil-568873

RESUMO

Este trabalho salienta a possibilidade de a alteração do excipiente de medicamentos tomados por longos períodos desencadear a Necrólise Epidérmica Tóxica. É feita a descrição clínica de paciente de 30 anos com farmacodermia associada ao uso de antirretrovirais.


This work emphasizes the possibility that changing the excipient of some drugs taken over long periods can trigger Toxic Epidermic Necrolysis. This article shows the clinical aspects of a patient who took AZT/r since March/2007. Thus, the suspicion that this drug would trigger Stevens-Johnson syndrome isn’t significative. On the other hand, the fact that the antiretroviral vehicle has been changed leads to a strong suspicion that it could be involved in triggering this syndrome. It is reported the clinical description of a 30-year patient eruption associated with the use of retroviral.


Assuntos
Humanos , Masculino , Adulto , Síndrome de Stevens-Johnson , Terapia Antirretroviral de Alta Atividade , Excipientes Farmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA