Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
J Clin Exp Dent ; 16(3): e367-e376, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38600931

RESUMO

Background: The aim of this systematic review is to determine the effectiveness of self-etching primers in comparison to the conventional protocol with hydrofluoric acid and silane treatment for bonding lithium disilicate ceramics. Material and Methods: The formulated PICO question for this research was: "Does self-etching silane primer surface treatment in lithium disilicate ceramics present a similar bond strength value compared to conventional hydrofluoric acid and silane treatment?". Combinations of words and appropriate truncations were adapted for each database. For the selection, duplicate articles were systematically eliminated using Mendeley software. The Cohen's Kappa statistic was then computed, RoBDEMAT questions were addressed, and the meta-analyses were conducted using RevMan 5.4, at a significance level of 5%. Results: Two independent reviewers conducted a blind and independent analysis of 190219 articles from PubMed, Scopus, Web of Science, and OpenGrey. Subsequently, they extracted data from 21 studies for the systematic review and in 16 the meta-analysis. In all in vitro studies, the most frequently cited concentration of hydrofluoric acid was 5%. In the meta-analysis, no statistical differences were observed between the two treatments concerning bond strength. Conclusions: Self-etching silane primers demonstrate promising results in lithium disilicate bonding, suggesting their potential as an alternative surface treatment to hydrofluoric acids + silane. Key words:Lithium disilicate, Hydrofluoric acid, Dental Porcelain, Ceramics, Silanes.

2.
J Esthet Restor Dent ; 36(9): 1326-1336, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38665052

RESUMO

OBJECTIVES: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling. MATERIALS AND METHODS: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB). Specimens underwent mechanical cycling (5 × 106 cycles; 150 N) evaluating fatigue resistance (number of failures) and those that failed were subsequently subjected to fractographic analyses (stereomicroscope and scanning electron microscope) to evaluate failure location and area, and maximum fracture load was also measured. RESULTS: The failure-related survival rate (100%) and maximum fracture resistance of the MZrB were significantly higher than those of MC and Zr (50%; p < 0.05). There were no significant differences in the failure rate and fracture resistance when a CoCr base abutment was used or not in the translucent monolithic Zr groups (p > 0.05;MZrB vs. MZr). Failure location, with MC crowns' fractures, noted at the screw area (p = 0.043), while all-ceramic crowns were mostly in the cuspid and to failure area, the Zr group had the largest mean (15.55 ± 9.17 mm2) among the groups, significant difference only when compared with MC (1.62 ± 0.81 mm2) (p = 0.025). CONCLUSIONS: Translucent monolithic zirconia crowns exhibited significantly higher fatigue and fracture resistance compared with conventional MC and bilayered crowns. CLINICAL SIGNIFICANCE: The appropriate choice of material and manufacturing technique is crucial for predicting the higher clinical performance of single crowns. Enhanced mechanical resistance in terms of fatigue and fracture resistance can be achieved by replacing MC and bilayered restorations with computer-aided design and computer-aided manufacturing monolithic zirconia.


Assuntos
Coroas , Análise do Estresse Dentário , Zircônio , Zircônio/química , Cerâmica/química , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Prótese Dentária Fixada por Implante , Teste de Materiais , Humanos
3.
Braz Oral Res ; 37: e034, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37132723

RESUMO

This study aimed to compare the mechanical properties of various occlusal plate materials by analyzing surface roughness, Knoop microhardness, flexural strength, and modulus of elasticity. Fifty samples were prepared and classified as SC (self-curing acrylic resin), WB (heat-cured acrylic resin), ME (acrylic resin polymerized by microwave energy), P (resin print), and M (polymethylmethacrylate polymer block for computer-aided design/computer-aided manufacturing). The data were analyzed using a one-way analysis of variance and Tukey's honestly significant difference test. Surface roughness was the same in all groups. The surface hardness of group M was statistically superior. The samples from groups P and M had higher flexural strength than other samples. The modulus of elasticity of group SC was statistically lower than that of other groups. The mechanical properties of the materials used to make the occlusal plates differed, and group M achieved the best results in all analyses. Therefore, clinicians must consider the material used to manufacture long-lasting and efficient occlusal splints.


Assuntos
Resinas Acrílicas , Placas Oclusais , Desenho Assistido por Computador , Resistência à Flexão , Dureza , Teste de Materiais , Propriedades de Superfície , Estresse Mecânico
4.
Braz. oral res. (Online) ; 37: e034, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1430028

RESUMO

Abstract This study aimed to compare the mechanical properties of various occlusal plate materials by analyzing surface roughness, Knoop microhardness, flexural strength, and modulus of elasticity. Fifty samples were prepared and classified as SC (self-curing acrylic resin), WB (heat-cured acrylic resin), ME (acrylic resin polymerized by microwave energy), P (resin print), and M (polymethylmethacrylate polymer block for computer-aided design/computer-aided manufacturing). The data were analyzed using a one-way analysis of variance and Tukey's honestly significant difference test. Surface roughness was the same in all groups. The surface hardness of group M was statistically superior. The samples from groups P and M had higher flexural strength than other samples. The modulus of elasticity of group SC was statistically lower than that of other groups. The mechanical properties of the materials used to make the occlusal plates differed, and group M achieved the best results in all analyses. Therefore, clinicians must consider the material used to manufacture long-lasting and efficient occlusal splints.

5.
J Clin Exp Dent ; 14(3): e235-e240, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35317292

RESUMO

Background: To evaluate the stress distribution of three-element prostheses on two different implant systems (External Hexagon (EH) or Morse Taper (MT)) and with two different retention mechanisms (screw-retained or cemented), by photoelastic analysis and strain gauge analyses. Material and Methods: Four photoelastic and 24 strain gauge models of a partially edentulous maxilla were made and were divided in four groups according to connection and retention system: Group I (EH-C) - external hexagon+cement-retained prosthesis; Group II (EH-S) external hexagon+screw-retained prosthesis; Group III (MT-C) - morse taper+cement-retained prosthesis; Group IV (MT-S) - morse taper+screw-retained prosthesis. The implants were installed in the axial position, the first in the region of element 15 and the distal implant in the region of element 17. Loads of 100 N were applied on the occlusal surface of the prosthesis for 10 seconds. For the photoelasticity analysis, photographic images were taken and were evaluated according to the number of high-intensity fringes. For the strain gauge analysis, the strain gauges were positioned on the marginal crest of the implants and on the apical region, being numbered for analysis of the stress distribution in each region. The electrical signals were captured and processed by specific software. Results: Higher concentration of tension was observed in the apical region of the implants and mainly in the distal implant, where the formation of fringes was higher. The microstrain values obtained for each group were similar: EH-C (454±18,3 µÉ›); EH-S (469±94 µÉ›); MT-C (466±49,8 µÉ›); MT-S (460±36,6 µÉ›). It was observed that apical position had higher stress concentrations for all analyzed groups. Conclusions: The different connections and fixation mode did not interfere in the amount of tension generated in the tissue adjacent to the implant, also the region that generated the greatest amount of tension was in the apical region of the anterior implant. Key words:Dental implants, biomechanics, fixed prosthodontics.

6.
J Prosthet Dent ; 128(4): 566-574, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33745685

RESUMO

STATEMENT OF PROBLEM: Although recent studies have reported the success of implant-supported monolithic restorations, consensus on the use of monolithic ceramic restorations is lacking. PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate the survival and biological and technical complication rates of monolithic single crowns and fixed partial dentures (FPDs). MATERIAL AND METHODS: An electronic search was conducted by 2 independent authors on the PubMed/MEDLINE, Scopus, and Cochrane Library databases. The Newcastle-Ottawa scale and Cochrane risk of bias tool were used to assess the quality and risk of bias of the included studies. Meta-analysis was performed by using the R software program. RESULTS: The search identified 763 articles, 18 of which met the eligibility criteria. A total of 15 studies evaluated monolithic ceramic single crowns, and 4 studies evaluated FPDs. The studies included 1061 monolithic single crowns (524 lithium disilicate, 461 zirconia, and 76 polymer-infiltrated ceramic network [PICN]) and 104 FPDs (36 lithium disilicate and 68 zirconia). Meta-analysis of single-arm studies indicated the proportion of survival, biological, and technical complication rates of 1% (95% confidence interval [CI]: 0% to 3%), 1% (CI: 0% to 4%), and 2% (CI: 1% to 4%), respectively, for single crowns, independent of ceramic material, and 3% (CI: 0% to 34%), 5% (CI: 1% to 21%), and 5% (CI: 1% to 21%) for FPDs, respectively. Only 5 studies performed a direct comparison between monolithic and veneered ceramic restorations, and no significant difference was observed in terms of survival (risk ratio [RR]: 0.68; CI: 0.25-1.91; P=.96), biological (RR: 0.69; CI: 0.31-1.53; P=.35), and technical complication rates (RR: 0.87; CI: 0.40-1.88; P=.29). CONCLUSIONS: The use of monolithic ceramic can be considered a favorable treatment for tooth-supported single crowns and FPDs, with high survival and low complication rates. However, further randomized controlled trials are needed to reassess these clinical performances, mainly by comparing them with the performance of veneered restorations.


Assuntos
Planejamento de Prótese Dentária , Falha de Restauração Dentária , Zircônio , Porcelana Dentária , Cerâmica , Coroas , Prótese Dentária Fixada por Implante/efeitos adversos
7.
Eur J Dent ; 16(2): 449-453, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34852392

RESUMO

OBJECTIVE: The aim of this study is to verify whether removable dentures of patients admitted to an intensive care unit (ICU) are niches of microorganisms that can cause pathologies (Staphylococcus aureus, Candida spp., and enterobacteria). MATERIALS AND METHODS: Fifteen patients who were denture wearers (removable partial denture and complete denture) were included in this study. Patients must wear their dentures daily, and these dentures must have acrylic parts. Microbial biofilm was collected from the acrylic part of one denture of each patient. Then, the biofilm was seeded on different culture media: Sabouraud agar, blood agar, MacConkey agar, and mannitol salt agar. In this study, biochemical evaluations of microorganisms were performed. STATISTICAL ANALYSIS: The percentage of dentures with the microorganism identified by each culture medium was calculated. RESULTS: In total, 100% of the dentures were positive for Staphylococcus spp. (blood agar) and Candida spp. (Sabouraud agar); 33.3% of the dentures were positive for S. aureus (Mannitol salt agar); and 13.3% of the dentures were positive for Shigella spp. (MacConkey agar). CONCLUSION: Removable dentures of patients (removable partial dentures and complete dentures) admitted to an ICU are niches of microorganisms that can cause pathologies.

8.
Dent Mater ; 37(12): 1873-1883, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34702557

RESUMO

OBJECTIVES: To characterize the surface of zirconia (Y-TZP) submitted to different surface treatments (with and without plasma associations) and to evaluate the shear bond strength (SBS) between veneering ceramic (VC) and Y-TZP after different aging methods. METHODS: 301 Y-TZP specimens were fabricated and distributed into 7 groups: C (control): no treatment; Al: airborne abrasion with 27 µm Al2O3 particle; L: liner; P: plasma; Al + L: airborne + liner; Al + P: airborne + plasma; P + L: plasma + liner. The Y-TZP surface was characterized by SEM, EDS, AFM, surface profilometry, surface-free energy (SFE), and XRD. SBS between Y-TZP and VC was verified after three aging protocols: initial, after hydrothermal aging (autoclave for 5 h), or thermal fatigue (30,000 baths - 5-55 °C). One- (profilometry, SFE) and two-way ANOVA (SBS), and Tukey's HSD test were used. RESULTS: For the plasma groups, a full globular surface coverage was observed (SEM, AFM). Si was found for Al, L, Al + L, and P + L. Roughness was lower for C, P, and Al + P. For SFE, the highest values were found when the liner was applied (>74.59 nm/Nm). The highest monoclinic content was observed for Al + L (6.96%) and Al + P (5.86%). For the initial period, Al and P + L presented the lowest SBS values (<5.85 MPa; P > 0.331). The highest SBS values were found for L, P, and P + L (hydrothermal aging) and for P, L, Al + L, and Al + P (thermal fatigue). SIGNIFICANCE: Changes in Y-TZP topography and the SBS with the VC were found, according to treatments performed. Plasma treatment improved SBS and did not cause phase transformation.


Assuntos
Colagem Dentária , Cerâmica , Teste de Materiais , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento , Propriedades de Superfície , Ítrio , Zircônio
9.
J Indian Prosthodont Soc ; 21(2): 125-137, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33938862

RESUMO

Aim: This systematic review with meta-analysis aimed to evaluate the effect of the laser treatment on bond strength between Y-TZP and the resin cement or with the veneering ceramic, and the effect on the alteration of the Y-TZP surface roughness. Settings and Design: Systematic review and meta analysis following PROSPERO guidelines. Materials and Methods: A comprehensive review was performed up to September 2020 on four databases (PubMed/MEDLINE, Embase, Scopus, and Cochrane Library), using the combination of keywords: "laser AND zirconia AND surface treatment AND bond strength". Statistical Analysis Used: The meta-analysis was based on the Mantel-Haenszel and inverse variance methods. The continuous outcome was evaluated by mean difference and the corresponding 95% confidence intervals. Results: A total of 37 studies were identified for the inclusion of data, with only in vitro studies. The types of laser reported in the studies were: Er:YAG, Nd:YAG, Er,Cr:YSGG, CO2, Femtosecond, and Yb lasers. A random-effect model found statistically significant differences between lasers and control groups of Y-TZP (P < 0.00001; MD: 3.08; 95% CI: 2.58 to 3.58). Only the bond strength with the Er:YAG laser did not present statistical difference (P = 0.51; MD: 0.22; 95% CI: -0.44-0.88). In another analysis, a random-effect model found a statistically significant difference between the laser and control groups on surface roughness (P < 0.00001; MD: 0.96; 95% CI: 0.86 to 1.06). Conclusions: Laser irradiation is capable to improve the Y-TZP surface roughness and the bond strength of zirconia with resin cement and veneering ceramics. However, there is a lack of laser protocol for the zirconia surface, a fact that makes a simple and direct comparison difficult.


Assuntos
Lasers de Estado Sólido , Cimentos de Resina , Cerâmica , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento , Propriedades de Superfície , Ítrio , Zircônio
10.
J Esthet Restor Dent ; 33(6): 919-924, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33045124

RESUMO

OBJECTIVE: To evaluate the optical, chemical, and mechanical properties of feldspathic porcelain after handling with different instrument materials. MATERIAL AND METHODS: Feldspathic porcelain was manipulated with different spatula compositions: metal spatula (MS), plastic spatula (PS), and glass spatula (GS) for the fabrication of 30 (n = 10) disks. Contrast ratio (CR), translucency parameter (TP), and surface Knoop microhardness (KHN) were measured. The color change (ΔE00 ) was evaluated using the CIEDE2000 system. Scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) were used for surface analysis. Data were analyzed using one-way ANOVA and Tukey test (P < 0.05). RESULTS: All groups presented different morphological surfaces with higher presence of Al on the MS. PS group presented lower Al, Si, K than MS, and GS. Higher CR was observed for PS (0.734; P < 0.043), followed by MS (0.696; P < 0.043) and GS (0.65; P < 0.011). The highest TP (13.06) and KHN (386.27) were presented by GS (P < 0.001). MS and PS presented similar KHN results. The higher ΔE00 were found for plastic/metal comparison. Also, the L* values for the MS group (67.49) were lower than the other groups. CONCLUSION: The use of metal spatula promoted higher color alteration during feldspathic porcelain manipulation than did the other materials. Handling with glass instrument promoted higher microhardness than other spatula materials. CLINICAL SIGNIFICANCE: The effect of the material used for ceramic handling on feldspathic porcelain properties is often ignored. This study shows that the handling spatula material must be carefully chosen to avoid inadvertent changes to the feldspathic porcelain restoration.


Assuntos
Cerâmica , Porcelana Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA