Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Vet Dent ; 38(2): 75-80, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34736337

RESUMO

Dental implants are not routinely used for rehabilitation in veterinary dentistry. For some veterinarians, further studies are necessary to be considered for clinical use in animals. The objective of the present in vitro study was to evaluate static fatigue of dental implants and to correlate that with the bite strength of dogs described in the literature. Sixty implants and abutments were used with the smallest diameter of each brand of implant utilized in the study. Three groups (n = 20) were created on the basis of the implant diameter, all with external hex connector: 3.30 mm (group 1), 4.0 mm (group 2) and 5.0 mm (group 3). All groups were subjected to quasi-static loading at 30° to the implant's long axis in a universal machine (model AME-5 kN). The mean fracture strength for group 1 was 964 ± 187 N, for group 2 was 1618 ± 149 N and for group 3 was 2595 ± 161 N. Significant differences between the groups with respect to resistance after the load applications were observed (P < .05). The diameter of implants affects the resistance to external forces during the application of non-axial strength (off-axis loading) and must be considered during the planning of rehabilitation to avoid problems.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Animais , Força de Mordida , Implantes Dentários/veterinária , Falha de Restauração Dentária/veterinária , Análise do Estresse Dentário/veterinária , Cães , Teste de Materiais/veterinária
2.
Rev. MVZ Córdoba ; 23(1): 6537-6551, Jan.-Apr. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-957351

RESUMO

ABSTRACT The traumatic accidents which result in fractures and even in impairment of a bone segment have a high prevalence in routine veterinary surgery. Many times these fractures are complex and difficulty healing or need bone grafts to preserve and restore the length of the affected limb. Thus, the recovery time of these animals is usually delicate and long, with complications risks, such as delayed union and non-union of the fractured bone segments or absence of graft incorporation. In this sense, the stem cells (SC) have shown to be a strong ally of the orthopedic doctors due to their capacity to provide osteoprogenitor cells, to increase the osteoinductive effect minimize the healing time and provide a greater efficiency to the repairing process. Due to that, before the expectation of their assignments, this review aims to describe the stem cells characteristics, their current applications in the fractures healing and, especially, their contribution to the bone grafts consolidation.


RESUMEN Los accidentes traumáticos que resultan en fracturas y hasta en el comprometimiento de un segmento óseo tienen alta prevalencia en la rutina quirúrgica veterinaria. Muchas veces esas fracturas son complejas y presentan dificultades de cicatrización o necesitan de injertos óseos para preservar y restaurar el largo del miembro acometido. De esa forma, el tiempo de recuperación de esos animales suele ser delicado y prolongado con riegos de complicaciones, como unión retardada y no unión de los segmentos óseos fracturados o ausencia de incorporación de los injertos. En este sentido, las células-madre (CT) vienen demostrando ser una fuerte aliada de los ortopedistas debido a su capacidad en proveer células osteoprogenitoras, de incrementar el efecto osteoinductor, minimizar el tiempo de cicatrización y proporcionar mayor eficiencia al proceso reparador. Frente a la expectativa de sus atribuciones, la presente revisión tiene por objetivo describir las características de las células-madre, sus aplicaciones actuales en la cicatrización de fracturas y, especialmente, su contribución en la consolidación de injertos óseos.


Assuntos
Medicina Veterinária , Osso e Ossos , Transplante Ósseo , Células-Tronco Mesenquimais , Terapia Baseada em Transplante de Células e Tecidos
3.
Vet Res Forum ; 9(4): 293-299, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30713606

RESUMO

The aim of this study was to evaluate the potential use of a DNA comet assay, DNA fragmentation fluorimetric assay and reactive oxygen species levels as potential biomarkers of genome conditions of dental pulp stem cells (DPSCs) isolated from dog canine teeth. Mesenchymal stem cells were isolated from the dental pulp collected from dog teeth. The results obtained suggest the ideal moment for clinical application of cellular therapy for this type of cell. The cell culture was maintained with Dulbecco's modified Eagle's medium supplemented with 10.00% fetal bovine serum for eight passages. During each passage, cell proliferation, oxidative stress and level of DNA fragmentation were assessed by3-(4,5-dimethylthiazol-2-yl)-2,5 diphenyltetrazolium (MTT) assay, testing 2,7 dichlorodihydro-fluorescein-diacetate and PicoGreen®, respectively. There were important differences among the first three DPSC passages compared to passages 4-8 and a large number of nuclei with some levels of DNA damage (30.00 to 40.00% in initial DPSC passages and > 50.00% in late passages), indicating in vitro DPSC genomic fragility. Within the limitations of this study, the results suggest these relatively simple and inexpensive approaches - comet and DNA fragmentation assays - could help sort stem cells with less DNA damage for use in research or therapies.

4.
Ciênc. rural (Online) ; 47(2): 1-6, 2017.
Artigo em Inglês | VETINDEX | ID: biblio-1479860

RESUMO

This study evaluated the use of bipolar electrosurgery and laparoscopic clipping, and their effects on blood loss and the inflammatory response, during a two portal video-assisted ovariohysterectomy technique (two groups with 10 animals each). Surgical time and blood loss volume were significantly lower in the electrosurgery group. There were no significant changes in haematocrit between groups; however, haematocrit did differ between evaluated times, and decreased 10% from the initial measurement to four hours after the procedure. The inflammatory response was significantly higher throughout the post-surgical period, but without any different clinical signs between the two groups. Both techniques had good application for the two portal video-assisted procedure; however, the bipolar electrosurgery allowed for shorter surgical times, reduced blood loss and a minimal learning curve for the surgeon.


Este estudo avaliou a utilização da eletrocirurgia bipolar e do clipador laparoscópico em relação à perda sanguínea e resposta inflamatória durante a ovariohisterectomia videoassistida com dois portais (dois grupos com 10 animais). O tempo cirúrgico, assim como o volume de sangue perdido foram significativamente menores no Grupo Bipolar. Não houve mudanças significativas no hematócrito entre os grupos, mas entre os tempos avaliados houve redução de 10% do valor inicial até quatro horas após o procedimento. A resposta inflamatória foi significativamente maior durante todo o período de avaliação após a cirurgia, mas sem manifestações clínicas diferentes daquelas apresentadas pelo Grupo Clipador. Ambas as técnicas têm boa execução pelo procedimento videoassistido, contudo, o uso da eletrocirurgia bipolar permite tempos cirúrgicos menores, perda de sangue mínima e menor curva de aprendizado para o cirurgião.


Assuntos
Feminino , Animais , Cães , Cirurgia Vídeoassistida , Cães , Eletrocirurgia , Eletrocirurgia/veterinária , Hemostasia Cirúrgica , Instrumentos Cirúrgicos
5.
Ci. Rural ; 47(2): 1-6, 2017.
Artigo em Inglês | VETINDEX | ID: vti-684408

RESUMO

This study evaluated the use of bipolar electrosurgery and laparoscopic clipping, and their effects on blood loss and the inflammatory response, during a two portal video-assisted ovariohysterectomy technique (two groups with 10 animals each). Surgical time and blood loss volume were significantly lower in the electrosurgery group. There were no significant changes in haematocrit between groups; however, haematocrit did differ between evaluated times, and decreased 10% from the initial measurement to four hours after the procedure. The inflammatory response was significantly higher throughout the post-surgical period, but without any different clinical signs between the two groups. Both techniques had good application for the two portal video-assisted procedure; however, the bipolar electrosurgery allowed for shorter surgical times, reduced blood loss and a minimal learning curve for the surgeon. (AU)


Este estudo avaliou a utilização da eletrocirurgia bipolar e do clipador laparoscópico em relação à perda sanguínea e resposta inflamatória durante a ovariohisterectomia videoassistida com dois portais (dois grupos com 10 animais). O tempo cirúrgico, assim como o volume de sangue perdido foram significativamente menores no Grupo Bipolar. Não houve mudanças significativas no hematócrito entre os grupos, mas entre os tempos avaliados houve redução de 10% do valor inicial até quatro horas após o procedimento. A resposta inflamatória foi significativamente maior durante todo o período de avaliação após a cirurgia, mas sem manifestações clínicas diferentes daquelas apresentadas pelo Grupo Clipador. Ambas as técnicas têm boa execução pelo procedimento videoassistido, contudo, o uso da eletrocirurgia bipolar permite tempos cirúrgicos menores, perda de sangue mínima e menor curva de aprendizado para o cirurgião. (AU)


Assuntos
Animais , Feminino , Cães , Eletrocirurgia , Eletrocirurgia/veterinária , Instrumentos Cirúrgicos , Hemostasia Cirúrgica , Cirurgia Vídeoassistida , Cães
6.
Ciênc. rural ; 47(2): 20151245, 2017. tab
Artigo em Inglês | LILACS | ID: biblio-828461

RESUMO

ABSTRACT: This study evaluated the use of bipolar electrosurgery and laparoscopic clipping, and their effects on blood loss and the inflammatory response, during a two portal video-assisted ovariohysterectomy technique (two groups with 10 animals each). Surgical time and blood loss volume were significantly lower in the electrosurgery group. There were no significant changes in haematocrit between groups; however, haematocrit did differ between evaluated times, and decreased 10% from the initial measurement to four hours after the procedure. The inflammatory response was significantly higher throughout the post-surgical period, but without any different clinical signs between the two groups. Both techniques had good application for the two portal video-assisted procedure; however, the bipolar electrosurgery allowed for shorter surgical times, reduced blood loss and a minimal learning curve for the surgeon.


RESUMO: Este estudo avaliou a utilização da eletrocirurgia bipolar e do clipador laparoscópico em relação à perda sanguínea e resposta inflamatória durante a ovariohisterectomia videoassistida com dois portais (dois grupos com 10 animais). O tempo cirúrgico, assim como o volume de sangue perdido foram significativamente menores no Grupo Bipolar. Não houve mudanças significativas no hematócrito entre os grupos, mas entre os tempos avaliados houve redução de 10% do valor inicial até quatro horas após o procedimento. A resposta inflamatória foi significativamente maior durante todo o período de avaliação após a cirurgia, mas sem manifestações clínicas diferentes daquelas apresentadas pelo Grupo Clipador. Ambas as técnicas têm boa execução pelo procedimento videoassistido, contudo, o uso da eletrocirurgia bipolar permite tempos cirúrgicos menores, perda de sangue mínima e menor curva de aprendizado para o cirurgião.

7.
Ci. Rural ; 47(2)2017.
Artigo em Inglês | VETINDEX | ID: vti-736738

RESUMO

ABSTRACT: This study evaluated the use of bipolar electrosurgery and laparoscopic clipping, and their effects on blood loss and the inflammatory response, during a two portal video-assisted ovariohysterectomy technique (two groups with 10 animals each). Surgical time and blood loss volume were significantly lower in the electrosurgery group. There were no significant changes in haematocrit between groups; however, haematocrit did differ between evaluated times, and decreased 10% from the initial measurement to four hours after the procedure. The inflammatory response was significantly higher throughout the post-surgical period, but without any different clinical signs between the two groups. Both techniques had good application for the two portal video-assisted procedure; however, the bipolar electrosurgery allowed for shorter surgical times, reduced blood loss and a minimal learning curve for the surgeon.


RESUMO: Este estudo avaliou a utilização da eletrocirurgia bipolar e do clipador laparoscópico em relação à perda sanguínea e resposta inflamatória durante a ovariohisterectomia videoassistida com dois portais (dois grupos com 10 animais). O tempo cirúrgico, assim como o volume de sangue perdido foram significativamente menores no Grupo Bipolar. Não houve mudanças significativas no hematócrito entre os grupos, mas entre os tempos avaliados houve redução de 10% do valor inicial até quatro horas após o procedimento. A resposta inflamatória foi significativamente maior durante todo o período de avaliação após a cirurgia, mas sem manifestações clínicas diferentes daquelas apresentadas pelo Grupo Clipador. Ambas as técnicas têm boa execução pelo procedimento videoassistido, contudo, o uso da eletrocirurgia bipolar permite tempos cirúrgicos menores, perda de sangue mínima e menor curva de aprendizado para o cirurgião.

8.
Acta sci. vet. (Impr.) ; 45: 1-7, 2017. ilus, tab
Artigo em Português | VETINDEX | ID: biblio-1457622

RESUMO

Background: Several routes of administration have been used for cell and gene therapy delivery in kidney disease in the last years. Moreover, a more homogenous distribution and a higher response was observed when administered intra-arterially. The main objective of the present study was to describe and to compare the use of Fogarty thru-lumen embolectomy catheter with angiographic catheter through the femoral artery by using conventional radiology as a guide.Materials, Methods & Results: Seven healthy dogs were used in these experiments. First, a Fogarty thru-lumen embolectomy catheter was introduced followed by an angiographic catheter. The primary outcome was the number of attempts for the placement of the introducer and the number of radiographic studies to carry out nephrography. Preceding the surgical procedure, ultrasonographic evaluation was performed in all animals in order to measure the diameter of the left and right femoral arteries, left and right renal and abdominal aorta at the renal level. After trichotomy and antisepsis of the medial face of the two pelvic limbs, the 6F valve introducer was placed based on the modified Seldinger technique. Thereafter, aortography was performed, showing its collateral arteries, with contrast injection, and it was estimated how much of the Fogarty 5,5F catheter had to be introduced. Subsequently, a guidewire was inserted through the catheter followed by the Fogarty catheter. Another x-ray was taken to show the position of the catheter. It was observed whether the catheter was positioned correctly and the cuff was filled, and then another contrasting radiograph was performed. If the contrast was not going to the kidneys, the cuff of the catheter was deflated, the catheter was repositioned and a new contrast radiography was performed.[...]


Assuntos
Animais , Cães , Artéria Renal , Cateteres Urinários/veterinária , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/veterinária , Angiografia/veterinária , Radiografia Intervencionista/métodos , Radiografia Intervencionista/veterinária , Tecnologia Radiológica/métodos , Tecnologia Radiológica/veterinária
9.
Acta sci. vet. (Online) ; 45: 1-7, 2017. ilus, tab
Artigo em Português | VETINDEX | ID: vti-20237

RESUMO

Background: Several routes of administration have been used for cell and gene therapy delivery in kidney disease in the last years. Moreover, a more homogenous distribution and a higher response was observed when administered intra-arterially. The main objective of the present study was to describe and to compare the use of Fogarty thru-lumen embolectomy catheter with angiographic catheter through the femoral artery by using conventional radiology as a guide.Materials, Methods & Results: Seven healthy dogs were used in these experiments. First, a Fogarty thru-lumen embolectomy catheter was introduced followed by an angiographic catheter. The primary outcome was the number of attempts for the placement of the introducer and the number of radiographic studies to carry out nephrography. Preceding the surgical procedure, ultrasonographic evaluation was performed in all animals in order to measure the diameter of the left and right femoral arteries, left and right renal and abdominal aorta at the renal level. After trichotomy and antisepsis of the medial face of the two pelvic limbs, the 6F valve introducer was placed based on the modified Seldinger technique. Thereafter, aortography was performed, showing its collateral arteries, with contrast injection, and it was estimated how much of the Fogarty 5,5F catheter had to be introduced. Subsequently, a guidewire was inserted through the catheter followed by the Fogarty catheter. Another x-ray was taken to show the position of the catheter. It was observed whether the catheter was positioned correctly and the cuff was filled, and then another contrasting radiograph was performed. If the contrast was not going to the kidneys, the cuff of the catheter was deflated, the catheter was repositioned and a new contrast radiography was performed.[...](AU)


Assuntos
Animais , Cães , Artéria Renal , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/veterinária , Cateteres Urinários/veterinária , Tecnologia Radiológica/métodos , Tecnologia Radiológica/veterinária , Angiografia/veterinária , Radiografia Intervencionista/métodos , Radiografia Intervencionista/veterinária
10.
Semina Ci. agr. ; 37(2): 867-876, mar.-abr. 2016. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-23430

RESUMO

Bladder calculi associated or not with early crystalluria or salt deposits can be a common finding after reconstructive bladder surgery. The objective of this study was to characterize calculi and urine of domestic rabbits treated with mesenchymal adipose-derived stem cells (ADSCs) after partial urinary bladder allotransplantation. Twenty-four New Zealand White rabbits were submitted to surgery and treated postoperatively with cyclosporine or ADSCs for immunosuppression. There were no signs of graft rejection in either treatment group 30 days after surgery. Fewer animals presented bladder calculi in the ADSC treated group (33.3%) compared to the cyclosporine treated group (58.3%). Calcium was the predominant component of calculi in both groups. Urinalysis revealed no haematuria or bacteriuria in the ADSC group, in contrast to the results obtained for the cyclosporine group. ADSCs may be an attractive alternative to cyclosporine for immunosuppression after bladder allotransplantation.(AU)


A litíase vesical pode ser um achado comum quando se faz a reconstrução da bexiga, condição que pode estar associada a alterações precoces como cristalúria e presença de depósito de sais. O objetivo deste artigo é caracterizar os cálculos e a urinálise de coelhos domésticos submetidos a alotransplante de vesícula urinária e tratados com células-tronco alogênicas derivadas do tecido adiposo (ADSCs). Foram utilizados 25 coelhos Nova Zelândia Branco, os quais foram submetidos a alotransplante parcial de bexiga e tratados com ciclosporina (GCi) ou células-tronco mesenquimais (GCe) como agentes imunossupressores. Houve menor número de animais com cálculo vesical no grupo tratado com ADSCs (33.3%), sendo cálcio o mineral mais frequentemente observado; na urinálise, os animais tratados com ADSCs não demonstraram hematúria e/ou bacteriúria. As ADSCs podem ser uma alternativa à ciclosporina para imunossupressão após alotransplante de bexiga.(AU)


Assuntos
Animais , Coelhos , Cálculos da Bexiga Urinária/veterinária , Cálculos da Bexiga Urinária/cirurgia , Alotransplante de Tecidos Compostos Vascularizados , Células-Tronco , Urinálise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA