Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 9(11): e21797, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38027580

RESUMO

Many studies have been conducted to focused on developing an optimal alkali/surfactant/polymer (ASP) composition to increase the recovered fraction of oil in reservoirs that have already undergone water injection. To analyze the effect of alkali (Na2CO3), surfactant (lauryl sodium sulfate), and polymer (commercial xanthan gum) concentration on oil recovery, a complete factorial experimental design was performed with combinations of three variables (alkali, surfactant, and polymer) and three central point replications (2³ + 3). The experiments were carried out on a core holder using rock samples from the Botucatu formation. The simulated oil reservoirs have an average permeability of 348 mD and a temperature of 60 °C. The crude oil was acquired from the Carmópolis field, with 25.72 °API. Synthetic production water containing 40,000 mg L-1 of NaCl and 13,000 mg L-1 of Na2SO4 was injected through an HPLC pump to saturate the rock samples and to recover the oil in the secondary step. From the experimental results, it was verified that the surfactant and polymer concentrations are the most statistically significant independent variables and that first-order interactions are not statistically significant for the process. The oil recovery factors in the secondary stage ranged between 30 and 36 % of the OOIP, which are within the range reported in the literature. The optimal composition of the ASP fluid obtained a recovered fraction of oil of 62 % in the advanced step. Other combinations reported in the literature used higher concentrations of alkali, surfactant, and polymer with lower recoveries and higher cost in the injection design. Thus, the present study highlights the necessity to investigate the performance of each component of the ASP solution. In addition, the results obtained in this study are very attractive for possible full-scale applications.

2.
Expert Opin Ther Pat ; 30(4): 287-301, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32008403

RESUMO

Introduction: This review aims to assess the available technologies, advances, and trends from technological readiness level 4 to level 8 for cancer immunologic therapeutics using the association of OX40 and CPG-ODN, usually known as cancer vaccine.Areas covered: Patent documents and clinic studies referring to the use of CpG-ODN and of OX40 association for cancer therapeutics. Patent data were obtained within the worldwide basis of the European Patent Office (EPO). The 138 patents of 36 patent families found were analyzed focusing on word distribution of technology developers and potential markets, legal status, annual evolution of first priority, technological domains, applicants and co-applicants and detailed analysis of each technology. Two clinical studies are in progress.Expert opinion: Traditional methods in post cancer diagnosis are being replaced by immunological association therapies. It is expected that the development of cancer vaccines will expand the scope of cancer-specific immunotherapy, especially if associated with alternative systems for expression and delivery with future potential. It is expected that genetic and controlled and/or specific nano delivery are improved. Furthermore, these new developments will likely address the problem of long-term treatments, reducing cancer mortality and reducing patient numbers worldwide.


Assuntos
Vacinas Anticâncer/uso terapêutico , Ligante OX40 , Oligodesoxirribonucleotídeos , Receptores OX40/efeitos dos fármacos , Adjuvantes Imunológicos , Animais , Humanos , Imunoterapia , Patentes como Assunto
3.
Expert Opin Ther Pat ; 28(7): 561-571, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29874935

RESUMO

INTRODUCTION: Bruxism is among the most chronic dental problems worldwide, and its perception may increase indicatively the condition of people's health, avoiding future health problems. Technologic solutions have improved considerably owing to new diagnostic and treatment technologies and their automation. This review aims to assess therapeutic methods for bruxism through analysis of patent applications spanning recent decades. AREAS COVERED: Patent families of bruxism, and products available on the market. Data were obtained through Questel Orbit from the European Patent Office on a worldwide basis using Cooperative Patent Classification (CPC), analyzing 134 patent families. The products on the market were mapped and classified as used for diagnosis, treatment, or both. EXPERT OPINION: This technological prospect has shown that the technological field of bruxism is growing toward smaller, automated devices; there is still no predominant owner of the technologies. Products are expected to provide home use with a high degree of reliability and specificity, using the Internet of Things (telemedicine associated with industry 4.0) and enabling real-time diagnosis.


Assuntos
Bruxismo/terapia , Equipamentos e Provisões , Bruxismo do Sono/terapia , Bruxismo/diagnóstico , Desenho de Equipamento , Humanos , Patentes como Assunto , Bruxismo do Sono/diagnóstico
4.
Talanta ; 117: 263-7, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-24209339

RESUMO

Power transformers are essential for a functioning electrical system and therefore require special attention by maintenance programs because a fault can harm both the company and society. The temperature inside a power transformer and the dissolved gases, which are primarily composed of acetylene, are the two main parameters monitored when detecting faults. This paper describes the development of a device for analyzing the acetylene content in insulating oil using spectrofluorimetry. Using this device introduces a new methodology for the maintaining and operating power transformers. The prototype is currently operating in a substation. The results presented by this system were satisfactory; when compared to chromatographic data, the errors did not exceed 15%. This prototype may be used to confirm the quality of an insulating oil sample to detect faults in power transformers.

5.
Waste Manag ; 33(12): 2670-4, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23993759

RESUMO

In Brazil, and mainly in the State of Bahia, crude vegetable oils are widely used in the preparation of food. Street stalls, restaurants and canteens make a great use of palm oil and soybean oil. There is also some use of castor oil, which is widely cultivated in the Sertão Region (within the State of Bahia), and widely applied in industry. This massive use in food preparation leads to a huge amount of waste oil of different types, which needs either to be properly disposed of, or recovered. At the Laboratorio Energia e Gas-LEN (Energy & Gas lab.) of the Universidade Federal da Bahia, a cycle of experiments were carried out to evaluate the recovery of waste oils for biodiesel production. The experiences were carried out on a laboratory scale and, in a semi-industrial pilot plant using waste oils of different qualities. In the transesterification process, applied waste vegetable oils were reacted with methanol with the support of a basic catalyst, such as NaOH or KOH. The conversion rate settled at between 81% and 85% (in weight). The most suitable molar ratio of waste oils to alcohol was 1:6, and the amount of catalyst required was 0.5% (of the weight of the incoming oil), in the case of NaOH, and 1%, in case of KOH. The quality of the biodiesel produced was tested to determine the final product quality. The parameters analyzed were the acid value, kinematic viscosity, monoglycerides, diglycerides, triglycerides, free glycerine, total glycerine, clearness; the conversion yield of the process was also evaluated.


Assuntos
Biocombustíveis/análise , Óleos de Plantas/química , Brasil , Resíduos Industriais , Projetos Piloto
6.
Talanta ; 85(1): 430-4, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21645721

RESUMO

Oxidation stability is an important quality parameter for biodiesel. In general, the methods used to evaluate the oxidation stability of oils and biodiesels are time-consuming. This work reports the use of spectrofluorimetry, a fast analytical technique, associated with multivariate data analysis as a powerful analytical tool to prediction of the oxidation stability. The prediction of the oxidation stability showed a good agreement with the results obtained by the EN14112 reference method Rancimat. The models presented high correlation (0.99276 and 0.97951) between real and predicted values. The R(2) values of 0.98557 and 0.95943 indicated the accuracy of the models to predict the oxidation stability of soy oil and soy biodiesel, respectively. The residual distribution does not follow a trend with respect to the predicted variables indicating the good quality of the fits.


Assuntos
Biocombustíveis/análise , Óleos/análise , Espectrometria de Fluorescência/métodos , Calibragem , Análise Multivariada , Óleos/química , Oxirredução , Controle de Qualidade , Óleo de Soja
7.
Anal Bioanal Chem ; 388(5-6): 1303-10, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17522849

RESUMO

Multipumping (MPFS) and multicommuted (MCFS) flow systems relying on pulsed and laminar flows were critically compared. The mixing conditions and dispersion associated with both systems were evaluated by simulating the sample with bromocresol green. The molybdenum blue method for phosphate determination in soil extracts was also implemented in both flow systems. Furthermore, laser-induced fluorescence (LIF) was applied to visualize the dispersing sample; rhodamine B was used as the fluorescent species. The pulsed flow enhanced the mixing of the solutions involved, thus reducing reagent consumption (48 and 96 microl for MPFS and MCFS), and improving sampling rate (67 and 144 h(-1) for MCFS and MPFS). For phosphate determination, results obtained with both systems were precise (r.s.d. < 0.5%; n = 10) and accurate. Analyses of the absorbance vs time/space LIF plots revealed that exploitation of pulsed flow led to a pronounced radial dispersion and to a limited axial dispersion, typical aspects of turbulent flows.


Assuntos
Técnicas de Química Analítica/métodos , Verde de Bromocresol/análise , Calibragem , Corantes Fluorescentes/química , Lasers , Modelos Químicos , Modelos Teóricos , Molibdênio/análise , Fosfatos/análise , Fosfatos/química , Reprodutibilidade dos Testes , Soluções , Espectrometria de Fluorescência , Fatores de Tempo
8.
J Phys Chem B ; 110(14): 7587-91, 2006 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-16599542

RESUMO

High-density polyethylene (HDPE) and polypropylene (PP) were studied to identify tailor-made materials for walls of pipelines and ducts for crude paraffinic oil that inhibit paraffin depositions. The interfacial interaction was investigated from 50 to 70 degrees C and as a function of the n-C(36)H(74) paraffin concentration added to the paraffinic crude oil. The static and the dynamic interfacial tensions were observed, respectively, by traditional contact angle measurements and by fluorescence depolarization of the natural fluorescent probes of the crude oil, flowing at a high rate. The static interaction showed a low dependence on the n-paraffin content for both surfaces. For PP, it decreased slightly as the n-paraffin concentration increased, evidencing an increase in the liquid-liquid interaction. The dynamic interfacial tension with PP clearly decreased as temperature and n-paraffin concentration increased, the latter effect being attributed to the PP methyl groups hindering the interaction between the n-paraffin and the PP main chain. For the flow on HDPE, the interaction proved to be highly dependent on the n-paraffin concentration and temperature. It increased as n-paraffin was added and temperature decreased. The former effect is attributed to the alignment of the n-paraffin chains within the high rate flowing liquid and the similar molecular geometry of the n-paraffin and the linear polymer surface (almost without branches), which increases the number of sites available for interaction. PP proved to be more suitable for transportation of crude oil rich in paraffins with more than 36 carbon atoms, while HDPE was more suitable for those with smaller paraffinic chains.

9.
J Colloid Interface Sci ; 281(1): 201-8, 2005 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-15567397

RESUMO

This work was concerned with the dependence of the interfacial tension (Gamma(SL)) on surface degree of oxygen content and on polymer branching degree. The static Gamma(SL) was evaluated by contact angle (theta;(c)) and the dynamic Gamma(SL) by fluorescence depolarization of molecular probes seeded in induced flows of monoethylene glycol. The latter results were interpreted using statistical covariant analysis. Two different systems of flowing films were studied: free films flowing on the surfaces on which they impinge and films flowing inside 1-mm-thick microflow cells. The solid surfaces were polyethylene of low density, medium density, high density, and linear with low density, polypropylene, vinyl acetate co-polymer with oxygen content of 15% and 28%, borosilicate, and tin dioxide. Increase in oxygen content of the surface decreased both the static and the dynamic Gamma(SL), which demonstrated that the presence of oxygen atoms hindered wetting. Only the dynamical Gamma(SL) was sensitive to polymer branching, and it increased as branching degree decreased. This was attributed to the higher hydrogen-atom density at the surface, which favored temporary intermolecular bonds between the surface and the flowing liquid.

10.
J Colloid Interface Sci ; 271(1): 201-5, 2004 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-14757095

RESUMO

A recent trend is the production of workable microchannel flow cells (MF cells). The nondestructive methods used to assess their reliability are based mainly on output monitoring and do not evaluate internal chemical interactions. We investigate a nondestructive method for evaluating changes in the chemical composition of the inner walls based on evaluation of the extent of alignment of a fluorescent probe in a liquid flowing within MF cells. Two MF cells were built with a 10-microm inner spacing. Their inner walls had four parallel SnO(2) strips, 2.00 mm wide, separated by 0.50-mm-wide glass strips. One cell had strips parallel to the flow and the other perpendicular. Flow-induced intermolecular alignment of rhodamine B in monoethylene glycol was scanned with 28-microm precision by fluorescence depolarization, using polarized-laser-induced fluorescence within induced flows (PLF-FI). No changes of polarization were seen when the flow was stopped. Under flowing conditions, polarization was always 4% lower in the glass region as compared to SnO(2). Glass had a higher solid-liquid interfacial tension (determined by contact angle measurements), thus being more wettable and increasing the drag, which propagates into the liquid flow, decreasing polarization. PLF-FI can thus identify regions with different chemical constitutions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA