Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Dent Traumatol ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37997541

RESUMO

BACKGROUND/AIM: The interaction between the ethylene-vinyl acetate (EVA) with distinct materials utilized for obtaining dental models can affect the performance of resulting mouthguards. This study attempted to evaluate the effect of different materials for conventional (dental stone) or 3D-printed (resin) models on EVA's physical and mechanical properties and surface characteristics. MATERIAL AND METHODS: EVA sheets (Bioart) were laminated over four model types: GIV, conventional Type IV dental stone model (Zhermak); ReG, resin-reinforced Type IV dental stone model (Zero Stone); 3DnT, 3D resin printed model (Anycubic) without surface treatment; 3DT, 3D-printed model (Anycubic) with water-soluble gel (KY Jelly Lubricant, Johnson & Johnson) coating during post-curing process. The EVA specimens were cut following the ISO 37-II standard (n = 30). Shore A hardness was measured before and after plasticization on the contact (internal) or opposite (external) surfaces with the model. The breaking force (F, N), elongation (EL, mm), and ultimate tensile strength (UTS, MPa) were measured using a universal testing machine. Macro-photography and scanning electron microscopy were adopted for classifying the EVA surface alteration. Data were analyzed by one-way ANOVA with repeated measures, followed by Tukey's test (α = .05). RESULTS: Plasticization significantly decreased Shore A values for the tested EVA regardless of the model type (p < .001). Higher F, El, and UTS values were verified for the EVA with 3DT and GIV models compared to ReG and 3DnT (p < .001). 3DnT models resulted in severe surface alteration and a greater reduction of the mechanical properties of the EVA. CONCLUSION: The interaction of EVA with 3D resin-printed models without surface treatment or resin-reinforced Type IV dental stone models significantly affected the physical and mechanical properties of this material. The utilization of water-soluble gel coating during the post-curing process of 3D resin printed models improved the mechanical properties of the EVA, similarly when this material was plasticized over conventional Type IV dental stone model.

2.
Clin Oral Investig ; 27(5): 2245-2253, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37010638

RESUMO

OBJECTIVE: This study is to evaluate fracture resistance, failure mode, and gap formation at the restorative interface of unrestored or restored non-carious cervical lesions (NCCLs) submitted to a short-term erosive environment. MATERIALS AND METHODS: Artificial NCCLs were produced in vitro in bovine incisors, and were randomly divided into four restorative resins groups (n = 22): nanohybrid-NR; bulk-fill-BR; flow with a nanohybrid layer-FNR; bulk-fill with a nanohybrid layer-BNR; and a group unrestored-UR (n = 16). Half of the specimens were submitted to an erosive challenge (per 5 min, 3 × a day for 7 days, before and after restoration), and the other half, was immersed in artificial saliva. After, all teeth undergone thermal (5 ºC, 37 ºC, and 55 ºC, 3600 cycles) and mechanical (50 N, 2 Hz, 300,000 cycles) aging. Eighty teeth were subjected to compressive loading, and resistance and failures were analyzed, while 24 teeth were evaluated for gaps by microcomputed tomography. Statistical tests were performed (p < 0.05). RESULTS: The restorative approaches affected fracture resistance (η2p = 0.14, p = 0.023), and gap formation (η2 = 0.18, p = 0.012) and so did the immersion medium (fracture η2p = 0.09, p = 0.008; gap η2 = 0.09, p = 0.017). BNR showed the highest resistance, while UR the lowest. FNR showed the highest gaps in both immersion media. Neither the resin groups nor the immersion media were associated with failure mode. CONCLUSIONS: The erosive immersion medium based in acid beverages has been shown to affect NCCLs with or without restoration, but when Bulk-Fill resin is covered by nanohybrid resin, the performance is good. CLINICAL RELEVANCE: Erosion negatively affects restorations, but unrestored NCCL shows worse biomechanical performance in stress-bearing situations.


Assuntos
Resinas Compostas , Materiais Dentários , Animais , Bovinos , Bebidas , Restauração Dentária Permanente/métodos , Teste de Materiais , Microtomografia por Raio-X
3.
Eur J Dent ; 16(2): 360-366, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34905778

RESUMO

OBJECTIVE: The aim of this study was to evaluate the influence of different light-curing units (LCUs) with distinct tip diameters and light spectra for activating bulk-fill resins. MATERIALS AND METHODS: The specimens (n = 10) were made from a conventional composite (Amaris, VOCO) and bulk-fill resins (Aura Bulk Fill, SDI; Filtek One, 3M ESPE; Tetric Bulk Fill, Ivoclar Vivadent) with two diameters, 7 or 10 mm, × 2 mm thickness. Following 24 hours of specimen preparation, the degree of conversion (DC) was evaluated using the Fourier-transform infrared unit. Knoop hardness (KHN) readings were performed on the center and periphery of the specimens. Data were assessed for homoscedasticity and submitted to one-way and three-way analysis of variance followed by the Tukey's and Dunnett's tests, depending on the analysis performed (α = 0.05). RESULTS: LCUs and specimen diameter significantly affected the DC. The Tetric Bulk Fill provided increased DC results when light-cured with Valo (54.8 and 53.5%, for 7 and 10 mm, respectively) compared with Radii Xpert (52.1 and 52.9%, for 7 and 10 mm, respectively). No significant differences in KHN results were noted for the conventional resin composite (Amaris) compared with LCUs (p = 0.213) or disc diameters (p = 0.587), but the center of the specimen exhibited superior KHN (p ≤ 0.001) than the periphery. CONCLUSION: The light spectrum of the multipeak LCU (Valo) significantly increased the DC and KHN of the bulk-fill resin composite with additional initiator to camphorquinone (Tetric Bulk Fill) compared with the monowave LCU (Radii Xpert). The tip size of the LCUs influenced the performance of some of the resin composites tested.

4.
Braz Oral Res ; 34: e004, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32022223

RESUMO

The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.


Assuntos
Cerâmica/química , Desenho Assistido por Computador , Porcelana Dentária/química , Vidro/química , Análise de Variância , Colagem Dentária/métodos , Resistência à Flexão , Teste de Materiais , Microscopia Eletrônica de Varredura , Porosidade , Valores de Referência , Reprodutibilidade dos Testes , Cimentos de Resina/química , Resistência ao Cisalhamento , Propriedades de Superfície , Difração de Raios X
5.
Braz. oral res. (Online) ; 34: e004, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055523

RESUMO

Abstract The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.


Assuntos
Cerâmica/química , Desenho Assistido por Computador , Porcelana Dentária/química , Vidro/química , Valores de Referência , Propriedades de Superfície , Difração de Raios X , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Porosidade , Colagem Dentária/métodos , Cimentos de Resina/química , Resistência ao Cisalhamento , Resistência à Flexão
6.
Braz Dent J ; 28(5): 624-631, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29215689

RESUMO

The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.


Assuntos
Hemostáticos , Cimentos de Resina/química , Cor , Microscopia Eletrônica de Varredura , Soluções , Análise Espectral , Propriedades de Superfície
7.
Braz. j. oral sci ; 16: e17070, jan.-dez. 2017. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-883661

RESUMO

The aim of this study was to evaluate the presence of filling material in oval root canals after endodontic retreatment performed by different techniques, considering the area (mm2), location and root third using computed microtomography (µ-CT). Methods: Thirty human lower central incisor underwent biomechanical preparation, root filling and filling removal using two techniques (n=15): MN- manual retreatment technique (Gates Glidden burs and stainless steel manual files); and RT- rotary retreatment technique (ProTaper Universal and ProTaper Retreatment Systems). Cross-sectional images of the teeth were made using µ-CT to identify the presence of remaining filling in all root thirds of the canal walls. The remaining material detected in 150 µ-CT sections was identified and its area quantified (mm2) for each root third individually. Results: Data analysis showed no difference in the remaining area of filling material (p=0.8611) for the both techniques. Higher frequency of remaining material was verified in the lingual wall of the root canals. Regardless of the retreatment technique, the apical third showed lager areas of remaining filling material. More areas of remaining material were detected in the cervical third of the RT group, whereas for the MN group, most areas were observed in the middle and apical thirds. Conclusion: According to our results, no significant differences were verified between the efficiency of the rotary and manual techniques for removing filling material due to the interferences caused by the root canal anatomy (AU)


Assuntos
Humanos , Masculino , Feminino , Retratamento , Preparo de Canal Radicular , Microtomografia por Raio-X
8.
Braz. dent. j ; 28(5): 624-631, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888690

RESUMO

Abstract The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.


Resumo O objetivo desse estudo foi avaliar o grau de conversão, estabilidade de cor, composição química e resistência de união de um cimento resinoso fotoativado contaminado com três soluções hemostáticas diferentes. Foram preparadas amostras para o grupo controle (cimento não contaminado) e grupos experimentais (cimento contaminado com uma das soluções hemostáticas) de acordo com os testes. Para o grau de conversão e análise de cor (n=10), as amostras (3 mm de diâmetro e 2 mm de espessura) foram avaliadas por espectroscopia de infravermelho com transformação de Fourier (FTIR) e espectrofotometria CIELAB (L*, A*, B*), respectivamente. Para a análise química elementar (n=1), os espécimes (2 mm de espessura e 6 mm de diâmetro) foram avaliados por espectroscopia de energia dispersiva de raios-x (EDS). As resistências de união dos grupos foram avaliadas pelo ensaio de microcisalhamento (n=20) em um substrato cerâmico de vidro reforçado com leucita, seguida da análise de modo de falha por microscopia eletrônica de varredura (MEV). Os valores médios, com exceção da avaliação química e do modo de falha, foram avaliados por ANOVA e pelo teste de Tukey. A estabilidade de cor foi influenciada pelo tempo de armazenagem (p<0,001) e interação entre a contaminação e o tempo (p<0,001). A contaminação pelo Hemostop e Viscostat Clear não influenciaram no GC, porém a contaminação com Viscostat aumentou o GC. A resistência de união do cimento a cerâmica foi negativamente afetada pelos contaminantes (p<0,001). A contaminação por agentes hemostáticos afetou a resistência de união, o grau de conversão e a estabilidade de cor do cimento resinoso fotoativado testado.


Assuntos
Hemostáticos , Cimentos de Resina/química , Cor , Microscopia Eletrônica de Varredura , Soluções , Análise Espectral , Propriedades de Superfície
9.
Braz Dent J ; 28(1): 16-23, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28301013

RESUMO

The aim of this study was to evaluate the µTBS in different dentin substrates and water-storage periods. Twenty-four dentin blocks obtained from sound third molars were randomly divided into 3 groups: Sound dentin (Sd), Caries-affected dentin (Ca) and Caries-infected dentin (Ci). Dentin blocks from Ca and Ci groups were subjected to artificial caries development (S. mutans biofilm). The softest carious tissue was removed using spherical drills under visual inspection with Caries Detector solution (Ca group). It was considered as Ci (softer and deeply red stained dentin) and Ca (harder and slightly red stained dentin). The Adper Single Bond 2 adhesive system was applied and Z350 composite blocks were built in all groups. Teeth were stored in deionized water for 24 h at 37 ºC and sectioned into beams (1.0 mm2 section area). The beams from each tooth were randomly divided into three storages periods: 24 h, 6 months or 1 year. Specimens were submitted to µTBS using EZ test machine at a crosshead speed of 1.0 mm/min. Failure mode was examined by SEM. Data from µTBS were submitted to split plot two-way ANOVA and Tukey's HSD tests (a=0.05). The µTBS (MPa) of Sd (41.2) was significantly higher than Ca (32.4) and Ci (27.2), regardless of storage. Ca and Ci after 6 months and 1 year, presented similar µTBS. Mixed and adhesive failures predominated in all groups. The highest µTBS values (48.1±9.1) were found for Sd at 24 h storage. Storage of specimens decreased the µTBS values for all conditions.


Assuntos
Cárie Dentária , Adesivos Dentinários , Dentina , Análise do Modo e do Efeito de Falhas na Assistência à Saúde , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Dente Serotino , Resistência à Tração
10.
J Appl Oral Sci ; 25(1): 61-68, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28198977

RESUMO

OBJECTIVE: The aim of this study was to assess the performance of resin cements when different curing modes are used, by evaluating the degree of conversion and bond strength to a ceramic substrate. MATERIAL AND METHODS: Three resin cements were evaluated, two dual-cured (Variolink II and RelyX ARC) and one light-cured (Variolink Veneer). The dual-cured resin cements were tested by using the dual activation mode (base and catalyst) and light-activation mode (base paste only). For degree of conversion (DC) (n=5), a 1.0 mm thick feldspathic ceramic disc was placed over the resin cement specimens and the set was light activated with a QTH unit. After 24 h storage, the DC was measured with Fourier transform infrared spectroscopy (FTIR). For microshear bond strength testing, five feldspathic ceramic discs were submitted to surface treatment, and three cylindrical resin cement specimens were bonded to each ceramic surface according to the experimental groups. After 24 h, microshear bond testing was performed at 0.5 mm/min crosshead speed until the failure. Data were submitted to one-way ANOVA followed by Tukey test (p<0.05). Scanning electron microscopy (SEM) was used for classifying the failure modes. RESULTS: Higher DC and bond strength values were shown by the resin cements cured by using the dual activation mode. The Variolink II group presented higher DC and bond strength values when using light-activation only when compared with the Variolink Veneer group. CONCLUSION: The base paste of dual-cured resin cements in light-activation mode can be used for bonding translucent ceramic restorations of up to or less than 1.0 mm thick.


Assuntos
Silicatos de Alumínio/química , Bis-Fenol A-Glicidil Metacrilato/química , Cerâmica/química , Cura Luminosa de Adesivos Dentários/métodos , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Compostos de Potássio/química , Cimentos de Resina/química , Análise de Variância , Lâmpadas de Polimerização Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Processos Fotoquímicos , Polimerização , Valores de Referência , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Propriedades de Superfície , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA