Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Intervalo de ano de publicação
2.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
3.
Circ., cariovasc. interv. (Print) ; 14(6): 010440, June. 2021. graf, ilus, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352656

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has determined a paradigm shift in the treatment of patients with severe aortic stenosis. However, the durability of bio prostheses is still a matter of concern, and little is known about the management of degenerated TAV. We sought to evaluate the outcomes of patients with a degenerated TAV treated by means of a second TAVR. METHODS: The TRANSIT is an international registry that included cases of degenerated TAVR from 28 centers. Among around 40 000 patients treated with TAVR in the participating centers, 172 underwent a second TAVR: 57 (33%) for a mainly stenotic degenerated TAV, 97 (56%) for a mainly regurgitant TAV, and 18 (11%) for a combined degeneration. Overall, the rate of New York Heart Association class III/IV at presentation was 73.5%. RESULTS: Valve Academic Research Consortium 2 device success rate was 79%, as a consequence of residual gradient (14%) or regurgitation (7%). At 1 month, the overall mortality rate was 2.9%, while rates of new hospitalization and New York Heart Association class III/IV were 3.6% and 7%, respectively, without significant difference across the groups. At 1 year, the overall mortality rate was 10%, while rates of new hospitalization and New York Heart Association class III/IV were 7.6% and 5.8%, respectively, without significant difference across the groups. No cases of valve thrombosis were recorded. CONCLUSIONS: Selected patients with a degenerated TAV may be safely and successfully treated by means of a second TAVR. This finding is of crucial importance for the adoption of the TAVR technology in a lower risk and younger population.


Assuntos
Estenose da Valva Aórtica , Próteses e Implantes , Substituição da Valva Aórtica Transcateter
4.
Am. j. cardiol ; 125(9): 1369-1377, May., 2020. graf.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1099637

RESUMO

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on preBAV was available for 1,262 patients (99.9%). Primary endpoints were pre-discharge moderate-tosevere paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation (PPI), and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n=1,051) or without predilatation (n=211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs. 3.4%, p=0.214; 30-day PPI 9.0% vs. 8.0%, p=0.660; 30-day death or stroke 4.9% vs. 4.4%, p=0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification. (AU)


Assuntos
Substituição da Valva Aórtica Transcateter , Valva Aórtica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA