Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Sensors (Basel) ; 24(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38203149

RESUMO

The use of advanced modulation and control schemes for power converters, such as a Feedback Quantizer and Predictive Control, is widely studied in the literature. This work focuses on improving the closed-loop modulation scheme called Feedback Quantizer, which is applied to a three-phase voltage source inverter. This scheme has the natural behavior of mitigating harmonics at low frequencies, which are detrimental to electrical equipment such as transformers. This modulation scheme also provides good tracking for the voltage reference at the fundamental frequency. On the other hand, the disadvantage of this scheme is that it has a variable switching frequency, creating a harmonic spectrum in frequency dispersion, and it also needs a small sampling time to obtain good results. The proposed scheme to improve the modulation scheme is based on a Discrete Space Vector with virtual vectors to obtain a better approximation of the optimal vectors for use in the algorithm. The proposal improves the conventional scheme at a high sampling time (200 µs), obtaining a THD less than 2% in the load current, decreases the noise created by the conventional scheme, and provides a fixed switching frequency. Experimental tests demonstrate the correct operation of the proposed scheme.

3.
Sensors (Basel) ; 23(14)2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37514583

RESUMO

Microgrids represent a promising energy technology, because of the inclusion in them of clean and smart energy technologies. They also represent research challenges, including controllability, stability, and implementation. This article presents a dSPACE-control-platform-based implementation of a fixed-switching-frequency modulated model predictive control (M2PC) strategy, as an inner controller of a two-level, three-phase voltage source inverter (VSI) working in an islanded AC microgrid. The developed controller is hierarchical, as it includes a primary controller to share the load equally with the other power converter with its own local modulated predictive-based controller. All details of the implementation are given for establishing the dSPACE-based implementation of the control on a dSPACE ds1103 control platform, using MATLAB/Simulink for the controller design, I/O implementation and configuration with the embedded dSPACE's real-time interface in Simulink, and then using the ControlDesk software for monitoring and testing of the real plant. The latter consists of the VSI operating with LCL filters, and sharing an RL load with a paralleled VSI with exactly the same controller. Finally, the obtained experimental waveforms are shown, with our respective conclusions representing this work, which is a very valuable tool for helping microgrid researchers implement dSPACE-based real-time simulations.

4.
Sensors (Basel) ; 23(8)2023 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37112161

RESUMO

Pulsed electrolysis has become a promising research topic in recent decades due to advances in solid-state semiconductor devices. These technologies have enabled the design and construction of simpler, more efficient, and less costly high-voltage and high-frequency power converters. In this paper, we study high-voltage pulsed electrolysis considering variations in both power converter parameters and cell configuration. Experimental results are obtained for frequency variations ranging from 10 Hz to 1 MHz, voltage changes from 2 V to 500 V, and electrode separations from 0.1 to 2 mm. The results demonstrate that pulsed plasmolysis is a promising method for decomposing water for hydrogen production.

5.
Sensors (Basel) ; 23(7)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37050455

RESUMO

Software Defined Networking (SDN) is a communication alternative to increase the scalability and resilience of microgrid hierarchical control. The common architecture has a centralized and monolithic topology, where the controller is highly susceptible to latency problems, resiliency, and scalability issues. This paper proposes a novel and intelligent control network to improve the performance of microgrid communications, solving the typical drawback of monolithic SDN controllers. The SDN controller's functionalities are segregated into microservices groups and distributed through a bare-metal Kubernetes cluster. Results are presented from PLECS hardware in the loop simulation to validate the seamless transition between standard hierarchical control to the SDN networked microgrid. The microservices significantly impact the performance of the SDN controller, decreasing the latency by 10.76% compared with a monolithic architecture. Furthermore, the proposed approach demonstrates a 42.23% decrease in packet loss versus monolithic topologies and a 53.41% reduction in recovery time during failures. Combining Kubernetes with SDN microservices can eliminate the single point of failure in hierarchical control, improve application recovery time, and enhance containerization benefits, including security and portability. This proposal represents a reference framework for future edge computing and intelligent control approaches in networked microgrids.

6.
Sensors (Basel) ; 24(1)2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38202887

RESUMO

The Scholander-type pressure chamber to measure midday stem water potential (MSWP) has been widely used to schedule irrigation in commercial vineyards. However, the limited number of sites that can be evaluated using the pressure chamber makes it difficult to evaluate the spatial variability of vineyard water status. As an alternative, several authors have suggested using the crop water stress index (CWSI) based on low-cost thermal infrared (TIR) sensors to estimate the MSWP. Therefore, this study aimed to develop a low-cost wireless infrared sensor network (WISN) to monitor the spatial variability of MSWPs in a drip-irrigated Cabernet Sauvignon vineyard under two levels of water stress. For this study, the MLX90614 sensor was used to measure canopy temperature (Tc), and thus compute the CWSI. The results indicated that good performance of the MLX90614 infrared thermometers was observed under laboratory and vineyard conditions with root mean square error (RMSE) and mean absolute error (MAE) values being less than 1.0 °C. Finally, a good nonlinear correlation between the MSWP and CWSI (R2 = 0.72) was observed, allowing the development of intra-vineyard spatial variability maps of MSWP using the low-cost wireless infrared sensor network.

7.
Sensors (Basel) ; 22(11)2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35684722

RESUMO

The use of controlled power converters has been extended for high power applications, stacking off-the-shelve semiconductors, and allowing the implementation of, among others, AC drives for medium voltages of 2.3 kV to 13.8 kV. For AC drives based on power cells assembled with three-phase diode rectifiers and cascaded H-bridge inverters, a sophisticated input multipulse transformer is required to reduce the grid voltage, provide isolation among the power cells, and compensate for low-frequency current harmonics generated by the diode-based rectifiers. However, this input multipulse transformer is bulky, heavy, and expensive and must be designed according to the number of power cells, not allowing total modularity of the AC drives based on cascade H-bridges. This study proposes and evaluates a control strategy based on a finite control set-model predictive control that emulates the harmonic cancellation performed by an input multipulse transformer in a cascade H-bridge topology. Hence, the proposed method requires conventional input transformers and replaces the three-phase diode rectifiers. As a result, greater modularity than the conventional multicell converter and improved AC overall input current with a THD as low as 2% with a unitary displacement power factor are achieved. In this case, each power cell manages its own DC voltage using a nonlinear control strategy, ensuring stable system operation for passive and regenerative loads. The experimental tests demonstrated the correct performance of the proposed scheme.

8.
Eur Respir J ; 59(2)2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34266942

RESUMO

BACKGROUND: The awake prone positioning strategy for patients with acute respiratory distress syndrome is a safe, simple and cost-effective technique used to improve hypoxaemia. We aimed to evaluate intubation and mortality risk in patients with coronavirus disease 2019 (COVID-19) who underwent awake prone positioning during hospitalisation. METHODS: In this retrospective, multicentre observational study conducted between 1 May 2020 and 12 June 2020 in 27 hospitals in Mexico and Ecuador, nonintubated patients with COVID-19 managed with awake prone or awake supine positioning were included to evaluate intubation and mortality risk through logistic regression models; multivariable and centre adjustment, propensity score analyses, and E-values were calculated to limit confounding. RESULTS: 827 nonintubated patients with COVID-19 in the awake prone (n=505) and awake supine (n=322) groups were included for analysis. Fewer patients in the awake prone group required endotracheal intubation (23.6% versus 40.4%) or died (19.8% versus 37.3%). Awake prone positioning was a protective factor for intubation even after multivariable adjustment (OR 0.35, 95% CI 0.24-0.52; p<0.0001, E=2.12), which prevailed after propensity score analysis (OR 0.41, 95% CI 0.27-0.62; p<0.0001, E=1.86) and mortality (adjusted OR 0.38, 95% CI 0.26-0.55; p<0.0001, E=2.03). The main variables associated with intubation among awake prone patients were increasing age, lower baseline peripheral arterial oxygen saturation/inspiratory oxygen fraction ratio (P aO2 /F IO2 ) and management with a nonrebreather mask. CONCLUSIONS: Awake prone positioning in hospitalised nonintubated patients with COVID-19 is associated with a lower risk of intubation and mortality.


Assuntos
COVID-19 , Insuficiência Respiratória , COVID-19/terapia , Humanos , Oxigênio/uso terapêutico , Decúbito Ventral , Insuficiência Respiratória/terapia , Estudos Retrospectivos , SARS-CoV-2 , Vigília
9.
Sensors (Basel) ; 21(19)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34640806

RESUMO

The use of renewable energies sources is taking great importance due to the high demand for electricity and the decrease in the use of fossil fuels worldwide. In this context, electricity generation through photovoltaic panels is gaining a lot of interest due to the reduction in installation costs and the rapid advance of the development of new technologies. To minimize or reduce the negative impact of partial shading or mismatches of photovoltaic panels, many researchers have proposed four configurations that depend on the power ranges and the application. The microinverter is a promising solution in photovoltaic systems, due to its high efficiency of Maximum Power Point Tracking and high flexibility. However, there are several challenges to improve microinverter's reliability and conversion efficiency that depend on the proper control design and the power converter design. This paper presents a review of different control strategies in microinverters for different applications. The control strategies are described and compared based on stability, dynamic response, topologies, and control objectives. One of the most important results showed that there is little research regarding the stability and robustness analysis of the reviewed control strategies.

10.
Med. crít. (Col. Mex. Med. Crít.) ; 33(5): 245-250, sep.-oct. 2019. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1287141

RESUMO

Resumen: Introducción: Las complicaciones postoperatorias a nivel pulmonar son causa de morbilidad y mortalidad, particularmente cuando desarrollan síndrome de dificultad respiratoria aguda y requieren ventilación mecánica; uno de los métodos empleados para pacientes que no responden al manejo ventilatorio convencional es la posición prono; sin embargo, hay poca evidencia sobre ventilación en prono en pacientes quirúrgicos abdominales. Material y métodos: Se revisó una cohorte de pacientes ventilados en prono para analizar el comportamiento de los cortocircuitos pulmonares y el índice PaO2/FiO2 antes, durante y después de la ventilación en prono. Resultados: Se observó una disminución significativa de los cortocircuitos pulmonares a partir de las 48 horas, mientras que el aumento de la PaO2/FiO2 fue significativa a partir de las 12 horas de prono; no se revisaron eventos adversos relevantes durante la pronación. Conclusiones: La ventilación en posición prono es una maniobra segura que provee una opción terapéutica en pacientes refractarios a manejo convencional, incluso durante el postquirúrgico de abdomen.


Abstract: Introduction: Postoperative complications at the respiratory level are a cause of morbidity and mortality, particularly when they develop acute respiratory distress syndrome and require mechanical ventilation; one of the methods used for patients who do not respond to conventional ventilatory management is the prone position, however, there is little evidence on prone ventilation in abdominal surgical patients. Material and methods: A cohort of patients ventilated in prone was reviewed to analyze the behavior of pulmonary shunts and the PaO2/FiO2 index before, during and after prone ventilation. Results: A significant decrease in pulmonary shunts was observed after 48 hours, while the increase in PaO2/FiO2 was significant after 12 hours of prone; no serioud adverse events were recorded during pronation. Conclusions: The prone position is a safe ventilatory maneuver that provides a therapeutic option in patients refractory to conventional management, even during abdominal post-surgery.


Resumo: Introdução: As complicações pós-operatórias a nível pulmonar causam morbimortalidade, principalmente quando desenvolvem síndrome do desconforto respiratório agudo e requerem ventilação mecânica; um dos métodos utilizados para pacientes que não respondem ao tratamento ventilatório convencional é a posição prona, no entanto, existem poucas evidências sobre a ventilação prona em pacientes cirúrgicos abdominais. Material e métodos: Uma coorte de pacientes ventilados em decúbito prona foi revisada para analisar o comportamento dos shunts pulmonares e o índice de PaO2/ FiO2 antes, durante e após a ventilação prona. Resultados: Foi observada uma diminuição significativa dos curtos-circuitos pulmonares após 48 horas, enquanto o aumento da PaO2/ FiO2 foi significativo após 12 horas; nenhum evento adverso relevante foi verificado durante a pronação. Conclusões: A ventilação prona é uma manobra segura que oferece uma opção terapêutica em pacientes refratários ao tratamento convencional, mesmo durante o abdome pós-cirúrgico.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA