Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pediatr Cardiol ; 2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38825661

RESUMO

This study aimed to analyze prenatal cardiac ultrasound markers of outcome in fetuses with Ebstein's anomaly (EA). From a retrospective database, 35 fetuses diagnosed with EA at fetal medicine centers in Brazil, Italy, and Poland were retrieved. The primary outcome was perinatal mortality. We analyzed prenatal cardiac ultrasound markers of outcomes and perinatal follow-up. Gestational age at diagnosis, extracardiac fetal anomalies, spontaneous fetal demise, and gestational age at each event were recorded. In postnatal survivors, data on cardiac surgery and short-term postoperative outcomes were collected. Our study included a cohort of 35 fetuses with EA (mean gestational age of 29.4 weeks), in which 6 fetuses were excluded due to termination of pregnancy (3), pregnancy still ongoing (2), and missed follow-up (1). Of the remaining 29 cases, severe tricuspid regurgitation and absence of anterograde pulmonary flow (pulmonary atresia) were observed in 88%. Significant cardiomegaly accounts for 58% of these data with a mean cardiothoracic ratio of 0.59. The cardiovascular profile (CVS) score ≤ 6 in six patients with one survival (4 fetal deaths, one stillbirth, and one survival). All fetuses with CVS score of 5 had intrauterine demise. Seventeen fetuses were born alive (53.1% of 29 cases). Of the remaining fetuses, one (1%) fetal was a stillbirth, six (20%) fetuses were neonatal deaths, and five (17%) fetuses were fetal deaths. Of the nineteen patients who underwent surgery to correct the cardiac defect, 17 survived after surgery. Among the survivors, biventricular cardiac repair was performed using the cone technique (da Silva's approach) in the majority of cases. We observed 2 abnormal karyotypes among in the remaining 29 fetuses. One of the patients with abnormal karyotype was a fetus with ascites and large for gestational age. The other patient with abnormal karyotype underwent cardiac surgery and progressed to neonatal death. Nine patients (25%) had extracardiac anomalies (genitourinary anomalies and single umbilical artery), being that 2 of them are alive and 4 died (2 had fetal and 2 neonatal death). Fetal EA is associated with high mortality. The most common prenatal marker associated with non-survival was CVP score ≤ 6. Fetuses that survived and underwent postnatal corrective surgery are significantly favorable outcomes.

2.
J Matern Fetal Neonatal Med ; 36(1): 2203791, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37080921

RESUMO

OBJECTIVE: This study aimed to analyze prenatal diagnosis, perinatal outcomes, and postnatal follow-up in fetuses with ectopia cordis (EC). METHODS: This retrospective analysis accessed 31 patients with EC who were either diagnosed or referred to a tertiary Fetal Medicine centers for EC diagnosis in Brazil, Germany, Italy, and Poland. We analyzed prenatal diagnosis, perinatal outcomes, and follow-up in these patients. RESULTS: Our study included a cohort of 31 fetuses with EC, 4 and 27 of whom had partial and complete protrusion of the heart through a ventral defect in the thoracoabdominal wall, respectively. EC was diagnosed by fetal echocardiography at a mean gestational age of 20.3 ± 8.6 weeks (range, 8-35 weeks). Of the four cases, in which the karyotype was performed, all of them had a normal result (1 - 46,XX and 3 - 46,XY). Five patients showed conotruncal abnormalities and six ventricular septal defects. Termination of pregnancy (TOP) was performed in 15 cases (48%) and seven pregnant women had spontaneous fetal demise (22.5%). Of the seven fetuses that were born alive, four of them died, and three infants underwent surgery. Among these three infants, all of them survived, one was 5 months, 13 years old and 29 years old at the time of study completion. CONCLUSIONS: Ectopia cordis is associated with high mortality rates and intracardiac/extra-cardiac defects. Ventricular septal defects and conotruncal anomalies were the more common intracardiac defects associated with EC. However, in this cohort of fetuses with EC the incidence of PC was lower than reported in the literature.


Assuntos
Ectopia Cordis , Cardiopatias Congênitas , Comunicação Interventricular , Lactente , Humanos , Gravidez , Feminino , Adolescente , Ectopia Cordis/diagnóstico por imagem , Estudos Retrospectivos , Seguimentos , Ultrassonografia Pré-Natal , Diagnóstico Pré-Natal , Cardiopatias Congênitas/diagnóstico
3.
Int J Cardiovasc Imaging ; 39(3): 531-539, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36334212

RESUMO

To determine reference values for the foramen ovale (FO) area of fetal hearts by three-dimensional (3D) ultrasound using spatio-temporal image correlation (STIC) method in the rendering mode, as well as applicability in fetuses with congenital heart disease (CHD). A retrospective and prospective study was performed of 242 normal fetuses and 36 fetuses with CHD between 20 and 33 + 6 weeks of gestation. The FO area was determined in the four-chamber view with manual delineation. To determine the reference curve of the FO area as a function of gestational age (GA), a linear regression model was utilized with an adjusted coefficient of determination (R2). For intra- and interobserver reproducibility calculations, the concordance correlation coefficient (CCC) was used. The mean ± standard deviation (SD) of the FO measurement area was 21.2 ± 1.8 and 48.1 ± 1.9 mm2 at 20 and 33 weeks' gestation, respectively. A linear correlation was observed between the FO area and GA (1.924*GA - 17.95; R2 = 0.91). Good intra- (CCC = 0.97) and interobserver (CCC = 0.94) agreement was observed for the FO area measurement. The mean difference in FO area between normal and CHD fetuses was - 14.4 mm2 (p < 0.001). Reference values for the FO area of fetal hearts were determined by 3D ultrasound using STIC in the rendering mode. This method showed good intra- and interobserver reproducibility and could be used to assess different CHD types.


Assuntos
Ecocardiografia Tridimensional , Forame Oval , Cardiopatias Congênitas , Feminino , Gravidez , Humanos , Ecocardiografia Tridimensional/métodos , Valores de Referência , Estudos Prospectivos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal/métodos , Valor Preditivo dos Testes , Coração Fetal/diagnóstico por imagem , Idade Gestacional
4.
J Perinat Med ; 51(6): 805-814, 2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-36584322

RESUMO

OBJECTIVES: To determine reference curves for fetal aortic and pulmonary valve annulus area by three-dimensional ultrasonography using the spatio-temporal image correlation (STIC) in the rendering mode, and to ascertain its applicability in congenital heart disease (CHD). METHODS: We performed a retrospective cross-sectional study of 328 normal fetuses and 42 fetuses with CHD between 20 and 33 weeks 6 days of gestation. The outflow plane view of the great vessels was used to measure the areas of the valvar annuli, and the measurements were performed in systole. A linear regression model adjusted according to the determination coefficient (R2) was utilized to construct the reference intervals. The concordance correlation coefficient (CCC) was used to calculate the reproducibility of the mitral and tricuspid valve areas. RESULTS: The mean ± standard deviation (SD) of the aortic and pulmonary valve annulus areas ranged from 6.6 ± 1.2 to 32.9 ± 1.1 mm2 and 10.7 ± 1.3 to 40.3 ± 1.2 mm2, respectively. We observed a linear relationship and strong positive correlation between the area of the aortic and pulmonary valve annuli with r=0.97 and 0.96, respectively. Good intra (CCC=0.99) and interobserver agreement (CCC=0.98) was observed for the measurement of the aortic valve annulus area. A good intra (CCC=0.99) and interobserver (CCC=0.97) agreement was also observed for the measurement of the pulmonary valve annulus area. The mean ± SD of the difference of the areas of the aortic and pulmonary valve annuli between the normal fetuses and those with CHD were -1.801 ± 1.429 mm2 (p=0.208) and -1.033 ± 1.467 mm2 (p<0.0001), respectively. CONCLUSIONS: The reference curves for the areas of the aortic and pulmonary valve annuli of fetal hearts were determined, and showed good inter and intraobserver reproducibility. The constructed reference curves showed applicability in different types of CHD.


Assuntos
Cardiopatias Congênitas , Valva Pulmonar , Feminino , Gravidez , Humanos , Valva Pulmonar/diagnóstico por imagem , Estudos Transversais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos , Coração Fetal/diagnóstico por imagem , Ultrassonografia , Cardiopatias Congênitas/diagnóstico por imagem
5.
Diagnostics (Basel) ; 12(11)2022 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-36428871

RESUMO

The aim of this review is to present a wide spectrum of placental and umbilical cord pathologies affecting the pregnancy. Placental and umbilical cord anomalies are highly associated with high-risk pregnancies and may jeopardize fetal well-being in utero as well as causing a predisposition towards poor perinatal outcome with increased fetal and neonatal mortality and morbidity. The permanent, computerized perinatology databases of different international centers have been searched and investigated to fulfil the aim of this manuscript. An extended gallery of prenatal imaging with autopsy correlation in specific cases will help to provide readers with a useful iconographic tool and will assist with the understanding and definition of this critical obstetrical and perinatological issue.

6.
J Matern Fetal Neonatal Med ; 35(16): 3070-3075, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32814485

RESUMO

BACKGROUND: An accurate estimated fetal weight (EFW) calculated with traditional formulae in cases of abdominal wall defects (AWDs) can be challenging. As a result of reduced abdominal circumference, fetal weight may be underestimated, which could affect prenatal management. Siemer et al. proposed a formula without the use of abdominal circumference, but it is not used in our protocols yet. OBJECTIVES: Our aim was to evaluate the correlation of EFW and birth weight in fetuses with AWD by using Hadlock 1, Hadlock 2, and Siemer et al.'s formulae. Our secondary goal was to evaluate how often fetuses classified as small for gestational age (SGA) were in fact SGA at birth. STUDY DESIGN: This was a retrospective cohort study of gestations complicated by gastroschisis and omphalocele at two tertiary-care centers in Brazil and Italy during an 8-year period. Of a total of 114 cases, 85 (44 cases of gastroschisis and 41 cases of omphalocele) met our criteria. RESULTS: The last prenatal scan was performed 5.2 (±4.1) days before birth. The mean gestational age at birth was 37.2 (±1.8) weeks. Correlation of EFW with birth weight was calculated with the three formulae with and without adjustment for weight gain between scan and birth, with the use of the Spearman coefficient. The correlation between EFW and weight at birth was positive according to all three formulae for the infants with gastroschisis. This finding was not confirmed in the infants with omphalocele. All formulae overestimated the number of SGA cases: although only 17.6% of fetuses were actually SGA at birth, the Hadlock formulae had classified nearly 35% of them as SGA, and Siemer et al.'s formula, 15.3%. CONCLUSION: All three formulae yielded a good correlation between EFW in the last scan and birth weight in the infants with gastroschisis but not for those with omphalocele. Cases of SGA were overestimated.


Assuntos
Gastrosquise , Hérnia Umbilical , Peso ao Nascer , Feminino , Retardo do Crescimento Fetal , Peso Fetal , Feto , Gastrosquise/complicações , Gastrosquise/epidemiologia , Idade Gestacional , Hérnia Umbilical/complicações , Hérnia Umbilical/epidemiologia , Humanos , Recém-Nascido , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal
7.
Prenat Diagn ; 34(12): 1153-60, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25042276

RESUMO

OBJECTIVES: The aims of this study were to assess the viewing rate and determine reference ranges ​​for the papillary muscle areas in the fetal atrio-ventricular valves using four-dimensional (4D) ultrasound and spatio-temporal image correlation (STIC) in the rendering mode. METHODS: This cross-sectional prospective study included 310 4D STIC volume data sets of normal fetuses between 18 weeks 0 day and 34 weeks 0 day of gestation. The papillary muscles were antero-lateral (MPAL) and postero-medial (MPPM) to the mitral valve and antero-superior (MPAS), inferior (MPI) and septal (MPS) to the tricuspid valve. Polynomial regressions were built to determine the reference ranges, and adjustments were made using the determination coefficient (R(2) ). To assess inter-observer reproducibility, the intra-class correlation coefficient (ICC) was used. RESULTS: Identification of the papillary muscles was possible in 89.3% patients. The best-fit regression equations between papillary muscle areas and gestational age were second degree. The inter-observer reproducibility was good (ICC: 0.98 to MPAS, 0.97 to MPI, 0.98 to MPS, 0.98 to MPAL and 0.97 to MPPM). CONCLUSIONS: Identification of the papillary muscles of the fetal valves was possible in most of the 4D STIC volume data sets, enabling the determination of reference ranges using the rendering mode. The reference ranges ​​for the papillary muscle areas were determined.


Assuntos
Coração Fetal/diagnóstico por imagem , Músculos Papilares/diagnóstico por imagem , Adolescente , Adulto , Estudos Transversais , Ecocardiografia Quadridimensional , Feminino , Humanos , Pessoa de Meia-Idade , Gravidez , Estudos Prospectivos , Valores de Referência , Ultrassonografia Pré-Natal , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA