1.
Arq Bras Cardiol ; 76(1): 15-28, 2001 Jan.
Artigo em Inglês, Português | MEDLINE | ID: mdl-11175481

RESUMO

OBJECTIVE: To identify left ventricular geometric patterns in hypertensive patients on echocardiography, and to correlate those patterns with casual blood pressure measurements and with the parameters obtained on a 24-hour ambulatory blood pressure monitoring. METHODS: We studied sixty hypertensive patients, grouped according to the Joint National Committee stages of hypertension. Using the single- and two-dimensional Doppler Echocardiography, we analyzed the left ventricular mass and the geometric patterns through the correlation of left ventricular mass index and relative wall thickness. On ambulatory blood pressure monitoring we assessed the means and pressure loads in the different geometric patterns detected on echocardiography RESULTS: We identified three left ventricular geometric patterns: 1) concentric hypertrophy, in 25% of the patients; 2) concentric remodeling, in 25%; and 3) normal geometry, in 50%. Casual systolic blood pressure was higher in the group with concentric hypertrophy than in the other groups (p=0.001). Mean systolic pressure in the 24h, daytime and nighttime periods was also higher in patients with concentric hypertrophy, as compared to the other groups (p=0.003, p=0.004 and p=0.007). Daytime systolic load and nighttime diastolic load were higher in patients with concentric hypertrophy ( p=0.004 and p=0.01, respectively). CONCLUSIONS: Left ventricular geometric patterns show significant correlation with casual systolic blood pressure, and with means and pressure loads on ambulatory blood pressure monitoring.


Assuntos
Hipertensão/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Remodelação Ventricular , Adolescente , Adulto , Idoso , Análise de Variância , Monitorização Ambulatorial da Pressão Arterial , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valores de Referência , Volume Sistólico , Ultrassonografia , Função Ventricular
2.
Arq Bras Cardiol ; 73(3): 291-8, 1999 Sep.
Artigo em Inglês, Português | MEDLINE | ID: mdl-10752168

RESUMO

OBJECTIVE: Studies have shown that therapy with beta-blockers reduces mortality in patients with heart failure. However, there are no studies describing the effects of propranolol on the QT dispersion in this population. The objective of this study was to assess the electrophysiological profile, mainly QT dispersion, of patients with heart failure regularly using propranolol. METHODS: Fifteen patients with heart failure and using propranolol were assessed over a period of 12 months. Twelve-lead electrocardiograms (ECG) were recorded prior to the onset of beta-blocker therapy and after 3 months of drug use. RESULTS: A significant reduction in heart rate, in QT dispersion and in QTc dispersion was observed, as was also an increase in the PR interval and in the QT interval, after the use of propranolol in an average dosage of 100 mg/day. CONCLUSION: Reduction in QT dispersion in patients with heart failure using propranolol may explain the reduction in the risk of sudden cardiac death with beta-blocker therapy, in this specific group of patients.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Eletrocardiografia/efeitos dos fármacos , Insuficiência Cardíaca/tratamento farmacológico , Frequência Cardíaca/efeitos dos fármacos , Propranolol/uso terapêutico , Adulto , Idoso , Eletrofisiologia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS