Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz J Med Biol Res ; 55: e11774, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35319673

RESUMO

Elastase-2 (ELA-2) is an angiotensin II-generating enzyme that participates in the cardiovascular system. ELA-2 is involved in hemodynamic and autonomic control and is upregulated in myocardial infarction and hypertension. The inhibition of angiotensin-converting enzyme (ACE) increased ELA-2 expression in the carotid arteries and heart of spontaneously hypertensive rats. In this study, we sought to investigate the role of ACE inhibition in hemodynamic and autonomic balance in elastase-2 knockout (ELA-2 KO) mice. Male ELA-2 KO and C57BL/6 mice were treated with the ACE inhibitor enalapril or saline for 10 days. After treatment, mice underwent surgery for cannulation of the femoral artery and arterial pressure recordings were made five days later in awake animals. The variability of systolic blood pressure (SBP) and pulse interval (PI) was evaluated in the time and frequency domain. Spontaneous baroreflex was assessed by the sequencing method. ACE inhibition caused a significant decrease in mean arterial pressure (117±2.2 vs 100±2.8 mmHg) and an increase in heart rate (570±32 vs 655±15 bpm) in ELA-2 KO mice. Despite a tendency towards reduction in the overall heart rate variability (standard deviation of successive values: 7.6±1.1 vs 4.7±0.6 ms, P=0.08), no changes were found in the root of the mean sum of squares or in the power of the high-frequency band. ACE inhibition did not change the spontaneous baroreflex indices (gain and baroreflex effectiveness index) in ELA-2 KO mice. Altogether, this data suggested that ACE played a role in the maintenance of hemodynamic function in ELA-2 KO mice.


Assuntos
Angiotensina II , Hemodinâmica , Animais , Hemodinâmica/fisiologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Elastase Pancreática
2.
Braz. j. med. biol. res ; 55: e11774, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1364555

RESUMO

Elastase-2 (ELA-2) is an angiotensin II-generating enzyme that participates in the cardiovascular system. ELA-2 is involved in hemodynamic and autonomic control and is upregulated in myocardial infarction and hypertension. The inhibition of angiotensin-converting enzyme (ACE) increased ELA-2 expression in the carotid arteries and heart of spontaneously hypertensive rats. In this study, we sought to investigate the role of ACE inhibition in hemodynamic and autonomic balance in elastase-2 knockout (ELA-2 KO) mice. Male ELA-2 KO and C57BL/6 mice were treated with the ACE inhibitor enalapril or saline for 10 days. After treatment, mice underwent surgery for cannulation of the femoral artery and arterial pressure recordings were made five days later in awake animals. The variability of systolic blood pressure (SBP) and pulse interval (PI) was evaluated in the time and frequency domain. Spontaneous baroreflex was assessed by the sequencing method. ACE inhibition caused a significant decrease in mean arterial pressure (117±2.2 vs 100±2.8 mmHg) and an increase in heart rate (570±32 vs 655±15 bpm) in ELA-2 KO mice. Despite a tendency towards reduction in the overall heart rate variability (standard deviation of successive values: 7.6±1.1 vs 4.7±0.6 ms, P=0.08), no changes were found in the root of the mean sum of squares or in the power of the high-frequency band. ACE inhibition did not change the spontaneous baroreflex indices (gain and baroreflex effectiveness index) in ELA-2 KO mice. Altogether, this data suggested that ACE played a role in the maintenance of hemodynamic function in ELA-2 KO mice.

3.
Mol Neurobiol ; 55(8): 7062-7071, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29383685

RESUMO

Several pieces of evidence indicate that elastase-2 (ELA2; chymotrypsin-like ELA2) is an alternative pathway to the generation of angiotensin II (ANGII). Elastase-2 knockout mice (ELA2KO) exhibit alterations in the arterial blood pressure and heart rate. However, there is no data on the behavioral consequences of ELA2 deletion. In this study, we addressed this question, submitting ELA2KO and wild-type (WT) mice to several models sensitive to anxiety- and depression-like, memory, and repetitive behaviors. Our data indicates a higher incidence of barbering behavior in ELA2KO compared to WT, as well as an anxiogenic phenotype, evaluated in the elevated plus maze (EPM). While a decrease in locomotor activity was observed in ELA2KO in EPM, this feature was not the main source of variation in the other parameters analyzed. The marble-burying test (MBT) indicated increase in repetitive behavior, observed by a higher number of buried marbles. The actimeter test indicated a decrease in total activity and confirmed the increase in repetitive behavior. The spatial memory was tested by repeated exposure to the actimeter in a 24-h interval. Both ELA2KO and WT exhibited decreased activity compared to the first exposure, without any distinction between the genotypes. However, when submitted to the cued fear conditioning, ELA2KO displayed lower levels of freezing behavior in the extinction session when compared to WT, but no difference was observed during the conditioning phase. Increased levels of BDNF were found in the prefrontal cortex but not in the hippocampus of ELA2KO mice compared to WT. Finally, in silico analysis indicates that ELA2 is putatively able to cleave BDNF, and incubation of the purified enzyme with BDNF led to the degradation of the latter. Our data suggested an anxiogenic- and antidepressant-like phenotype of ELA2KO, possibly associated with increased levels of BDNF in the prefrontal cortex.


Assuntos
Antidepressivos/metabolismo , Ansiedade/enzimologia , Fator Neurotrófico Derivado do Encéfalo/metabolismo , Córtex Pré-Frontal/metabolismo , Serina Endopeptidases/deficiência , Animais , Comportamento Animal , Simulação por Computador , Condicionamento Psicológico , Medo , Feminino , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Fenótipo , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Proteínas Recombinantes/farmacologia , Serina Endopeptidases/genética , Serina Endopeptidases/metabolismo
4.
Braz J Med Biol Res ; 49(10): e5294, 2016 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-27580004

RESUMO

Determination of left ventricular ejection fraction (LVEF) using in vivo imaging is the cardiac functional parameter most frequently employed in preclinical research. However, there is considerable conflict regarding the effects of anesthetic agents on LVEF. This study aimed at assessing the effects of various anesthetic agents on LVEF in hamsters using transthoracic echocardiography. Twelve female hamsters were submitted to echocardiography imaging separated by 1-week intervals under the following conditions: 1) conscious animals, 2) animals anesthetized with isoflurane (inhaled ISO, 3 L/min), 3) animals anesthetized with thiopental (TP, 50 mg/kg, intraperitoneal), and 4) animals anesthetized with 100 mg/kg ketamine plus 10 mg/kg xylazine injected intramuscularly (K/X). LVEF obtained under the effect of anesthetics (ISO=62.2±3.1%, TP=66.2±2.7% and K/X=75.8±1.6%) was significantly lower than that obtained in conscious animals (87.5±1.7%, P<0.0001). The K/X combination elicited significantly higher LVEF values compared to ISO (P<0.001) and TP (P<0.05). K/X was associated with a lower dispersion of individual LVEF values compared to the other anesthetics. Under K/X, the left ventricular end diastolic diameter (LVdD) was increased (0.60±0.01 cm) compared to conscious animals (0.41±0.02 cm), ISO (0.51±0.02 cm), and TP (0.55±0.01 cm), P<0.0001. The heart rate observed with K/X was significantly lower than in the remaining conditions. These results indicate that the K/X combination may be the best anesthetic option for the in vivo assessment of cardiac systolic function in hamsters, being associated with a lower LVEF reduction compared to the other agents and showing values closer to those of conscious animals with a lower dispersion of results.


Assuntos
Anestésicos/farmacologia , Volume Sistólico/efeitos dos fármacos , Função Ventricular Esquerda/efeitos dos fármacos , Animais , Combinação de Medicamentos , Ecocardiografia/métodos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/efeitos dos fármacos , Isoflurano/farmacologia , Ketamina/farmacologia , Mesocricetus , Valores de Referência , Sístole/efeitos dos fármacos , Tiopental/farmacologia , Fatores de Tempo , Xilazina/farmacologia
5.
Physiol Meas ; 37(7): 1120-8, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27328016

RESUMO

Analysis of heart rate variability (HRV) is performed through interbeat interval time series derived from either electrocardiographic or arterial pressure (AP) recordings. However, little attention has been given to the reliability of calculating the time series from different sources, i.e. electrocardiogram (ECG) or pulse intervals (PI). Therefore, the present study aimed to evaluate the correlation between interbeat interval time series obtained from RR, inter-systolic (SS) and inter-diastolic (DD) intervals, as well as their impact on indices of HRV calculated from series of RR or PI. Conscious rats previously instrumented with subcutaneous electrodes and a catheter into the femoral artery were subjected to simultaneous ECG and AP recording for 5 min. Correlation and Bland-Altman plots between RR and PI were evaluated. Moreover, HRV was analyzed in time (mean cardiac interval, SDNN and RMSSD) and frequency domain (power in LF and HF spectral bands) as well as by nonlinear approaches (symbolic dynamics and sample entropy). First, RR showed a stronger correlation with PI calculated by DD than SS. Second, most HRV indices showed similar results when calculated with RR or DD series, but not with SS series. Considering RR interval as the gold standard for the calculation of cardiac cycle, when using PI inter diastolic intervals are the better choice to study HRV. These findings are quite relevant, especially when AP recording is used for HRV analysis.


Assuntos
Pressão Arterial/fisiologia , Determinação da Pressão Arterial , Eletrocardiografia , Artéria Femoral/fisiologia , Frequência Cardíaca/fisiologia , Animais , Determinação da Pressão Arterial/métodos , Eletrocardiografia/métodos , Eletrodos Implantados , Masculino , Modelos Cardiovasculares , Dinâmica não Linear , Ratos Wistar , Processamento de Sinais Assistido por Computador , Vigília/fisiologia
6.
Braz. j. med. biol. res ; 45(5): 444-449, May 2012. ilus
Artigo em Inglês | LILACS | ID: lil-622770

RESUMO

The time to reach the maximum response of arterial pressure, heart rate and vascular resistance (hindquarter and mesenteric) was measured in conscious male spontaneously hypertensive (SHR) and normotensive control rats (NCR; Wistar; 18-22 weeks) subjected to electrical stimulation of the aortic depressor nerve (ADN) under thiopental anesthesia. The parameters of stimulation were 1 mA intensity and 2 ms pulse length applied for 5 s, using frequencies of 10, 30, and 90 Hz. The time to reach the hemodynamic responses at different frequencies of ADN stimulation was similar for SHR (N = 15) and NCR (N = 14); hypotension = NCR (4194 ± 336 to 3695 ± 463 ms) vs SHR (3475 ± 354 to 4494 ± 300 ms); bradycardia = NCR (1618 ± 152 to 1358 ± 185 ms) vs SHR (1911 ± 323 to 1852 ± 431 ms), and the fall in hindquarter vascular resistance = NCR (6054 ± 486 to 6550 ± 847 ms) vs SHR (4849 ± 918 to 4926 ± 646 ms); mesenteric = NCR (5574 ± 790 to 5752 ± 539 ms) vs SHR (5638 ± 648 to 6777 ± 624 ms). In addition, ADN stimulation produced baroreflex responses characterized by a faster cardiac effect followed by a vascular effect, which together contributed to the decrease in arterial pressure. Therefore, the results indicate that there is no alteration in the conduction of the electrical impulse after the site of baroreceptor mechanical transduction in the baroreflex pathway (central and/or efferent) in conscious SHR compared to NCR.


Assuntos
Animais , Masculino , Ratos , Barorreflexo/fisiologia , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Hipertensão/fisiopatologia , Aorta/inervação , Estado de Consciência , Estimulação Elétrica , Ratos Endogâmicos SHR , Ratos Wistar , Estudos Retrospectivos , Resistência Vascular/fisiologia
7.
Braz J Med Biol Res ; 45(5): 444-9, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22415118

RESUMO

The time to reach the maximum response of arterial pressure, heart rate and vascular resistance (hindquarter and mesenteric) was measured in conscious male spontaneously hypertensive (SHR) and normotensive control rats (NCR; Wistar; 18-22 weeks) subjected to electrical stimulation of the aortic depressor nerve (ADN) under thiopental anesthesia. The parameters of stimulation were 1 mA intensity and 2 ms pulse length applied for 5 s, using frequencies of 10, 30, and 90 Hz. The time to reach the hemodynamic responses at different frequencies of ADN stimulation was similar for SHR (N = 15) and NCR (N = 14); hypotension = NCR (4194 ± 336 to 3695 ± 463 ms) vs SHR (3475 ± 354 to 4494 ± 300 ms); bradycardia = NCR (1618 ± 152 to 1358 ± 185 ms) vs SHR (1911 ± 323 to 1852 ± 431 ms), and the fall in hindquarter vascular resistance = NCR (6054 ± 486 to 6550 ± 847 ms) vs SHR (4849 ± 918 to 4926 ± 646 ms); mesenteric = NCR (5574 ± 790 to 5752 ± 539 ms) vs SHR (5638 ± 648 to 6777 ± 624 ms). In addition, ADN stimulation produced baroreflex responses characterized by a faster cardiac effect followed by a vascular effect, which together contributed to the decrease in arterial pressure. Therefore, the results indicate that there is no alteration in the conduction of the electrical impulse after the site of baroreceptor mechanical transduction in the baroreflex pathway (central and/or efferent) in conscious SHR compared to NCR.


Assuntos
Barorreflexo/fisiologia , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Hipertensão/fisiopatologia , Animais , Aorta/inervação , Estado de Consciência , Estimulação Elétrica , Masculino , Ratos , Ratos Endogâmicos SHR , Ratos Wistar , Estudos Retrospectivos , Resistência Vascular/fisiologia
8.
Braz. j. med. biol. res ; 44(6): 583-591, June 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-589975

RESUMO

Ventilatory differences between rat strains and genders have been described but the morphology of the phrenic nerve has not been investigated in spontaneously hypertensive (SHR) and normotensive Wistar-Kyoto (WKY) rats. A descriptive and morphometric study of the phrenic nerves of male (N = 8) and female (N = 9) SHR, and male (N = 5) and female (N = 6) WKY is presented. After arterial pressure and heart rate recordings, the phrenic nerves of 20-week-old animals were prepared for epoxy resin embedding and light microscopy. Morphometric analysis performed with the aid of computer software that took into consideration the fascicle area and diameter, as well as myelinated fiber profile and Schwann cell nucleus number per area. Phrenic nerves were generally larger in males than in females on both strains but larger in WKY compared to SHR for both genders. Myelinated fiber numbers (male SHR = 228 ± 13; female SHR = 258 ± 4; male WKY = 382 ± 23; female WKY = 442 ± 11 for proximal right segments) and density (N/mm²; male SHR = 7048 ± 537; female SHR = 10355 ± 359; male WKY = 9457 ± 1437; female WKY = 14351 ± 1448) for proximal right segments) were significantly larger in females of both groups and remarkably larger in WKY than SHR for both genders. Strain and gender differences in phrenic nerve myelinated fiber number are described for the first time in this experimental model of hypertension, indicating the need for thorough functional studies of this nerve in male and female SHR.


Assuntos
Animais , Feminino , Masculino , Ratos , Nervo Frênico/anatomia & histologia , Ratos Endogâmicos SHR/anatomia & histologia , Ratos Endogâmicos WKY/anatomia & histologia , Bainha de Mielina , Fibras Nervosas Mielinizadas , Fatores Sexuais , Especificidade da Espécie
9.
Braz J Med Biol Res ; 44(6): 583-91, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21537611

RESUMO

Ventilatory differences between rat strains and genders have been described but the morphology of the phrenic nerve has not been investigated in spontaneously hypertensive (SHR) and normotensive Wistar-Kyoto (WKY) rats. A descriptive and morphometric study of the phrenic nerves of male (N = 8) and female (N = 9) SHR, and male (N = 5) and female (N = 6) WKY is presented. After arterial pressure and heart rate recordings, the phrenic nerves of 20-week-old animals were prepared for epoxy resin embedding and light microscopy. Morphometric analysis performed with the aid of computer software that took into consideration the fascicle area and diameter, as well as myelinated fiber profile and Schwann cell nucleus number per area. Phrenic nerves were generally larger in males than in females on both strains but larger in WKY compared to SHR for both genders. Myelinated fiber numbers (male SHR = 228 ± 13; female SHR = 258 ± 4; male WKY = 382 ± 23; female WKY = 442 ± 11 for proximal right segments) and density (N/mm²; male SHR = 7048 ± 537; female SHR = 10355 ± 359; male WKY = 9457 ± 1437; female WKY = 14351 ± 1448) for proximal right segments) were significantly larger in females of both groups and remarkably larger in WKY than SHR for both genders. Strain and gender differences in phrenic nerve myelinated fiber number are described for the first time in this experimental model of hypertension, indicating the need for thorough functional studies of this nerve in male and female SHR.


Assuntos
Nervo Frênico/anatomia & histologia , Ratos Endogâmicos SHR/anatomia & histologia , Ratos Endogâmicos WKY/anatomia & histologia , Animais , Feminino , Masculino , Bainha de Mielina , Fibras Nervosas Mielinizadas , Ratos , Fatores Sexuais , Especificidade da Espécie
10.
Braz J Med Biol Res ; 43(10): 969-75, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20945035

RESUMO

The low incidence of cardiovascular diseases, including hypertension, in premenopausal women has led to the conclusion that ovarian hormones may have a protective effect on the cardiovascular system. We evaluated the effects of ovariectomy and/or estradiol on sympathovagal balance and heart rate variability (HRV) in female spontaneously hypertensive rats (SHR) with tachycardia and compared them to Wistar rats (12 weeks old; N = 8-12). Ovariectomy (OVX) and/or estradiol (10 µg/kg) did not affect basal arterial pressure in either rat strain, but estradiol increased basal heart rate (HR) in OVX SHR (454 ± 18 vs 377 ± 9 bpm). HR changes elicited by methylatropine and propranolol were used to evaluate the sympathovagal balance. Ovariectomy did not affect the cardiac sympathovagal balance of any group, while estradiol increased sympathetic tone in OVX SHR (120 ± 8 vs 56 ± 10 bpm) and sham-operated Wistar rats (57 ± 7 vs 28 ± 4 bpm), and decreased the parasympathetic tone only in OVX SHR (26 ± 7 vs 37 ± 5 bpm). HRV was studied in the frequency domain (Fast Fourier Transformation). Spectra of HR series were examined at low frequency (LF: 0.2-0.75 Hz) and high frequency (HF: 0.75-3 Hz) bands. The power of LF, as well as the LF/HF ratio, was not affected by ovariectomy, but estradiol increased both LF (29 ± 4 vs 18 ± 3 nu in Wistar sham-operated, 26 ± 5 vs 15 ± 3 nu in Wistar OVX, 50 ± 3 vs 38 ± 4 nu in SHR sham-operated, and 51 ± 3 vs 42 ± 3 nu in SHR OVX) and LF/HF (0.48 ± 0.08 vs 0.23 ± 0.03 nu in Wistar sham-operated, 0.41 ± 0.14 vs 0.19 ± 0.05 nu in Wistar OVX, 0.98 ± 0.11 vs 0.63 ± 0.11 nu in SHR sham-operated, and 1.10 ± 0.11 vs 0.78 ± 0.1 nu in SHR OVX). Thus, we suggest that ovariectomy did not affect the cardiac sympathovagal balance of SHR or Wistar rats, while estradiol increased the sympathetic modulation of HR.


Assuntos
Pressão Sanguínea/efeitos dos fármacos , Estradiol/farmacologia , Estrogênios/farmacologia , Frequência Cardíaca/efeitos dos fármacos , Ovariectomia , Sistema Nervoso Simpático/efeitos dos fármacos , Animais , Feminino , Ratos , Ratos Endogâmicos SHR , Ratos Wistar , Sistema Nervoso Simpático/fisiologia , Nervo Vago/efeitos dos fármacos , Nervo Vago/fisiologia
SELEÇÃO DE REFERÊNCIAS