Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMJ Open Sport Exerc Med ; 7(3): e001096, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34540268

RESUMO

OBJECTIVE: To analyse rider's subjective responses after a standardised bicycle ergonomic adjustment method. METHODS: Experimental study of 160 healthy, amateur mountain bikers analysed previously and 30 days after a bike-fitting session. The main outcome measures were subjective comfort level (Feeling Scale, FEEL), fatigue (OMINI Scale) and pain (Visual Analogue Scale, VAS). RESULTS: All variables demonstrated statistical significance between groups pre and post bike-fit session (p<0001). FEEL, OMNI and VAS-knee demonstrated large effect sizes (d=1.30; d=1.39 and d=0.86, respectively). VAS-hands, VAS-neck and VAS-back indicated moderate effect size (d=0.58; d=0.52 and d=0.43, respectively). VAS-groin and VAS-ankle indicated a small size effect (d=0.46 and d=0.43, respectively). CONCLUSIONS: Overall discomfort, fatigue and pain in healthy mountain biker adults improved according to all three scales. The major improvements in pain levels were detected on the knee, hands, back and neck compared with presession values. Groin and ankle pain had smaller improvements but were still significant. Future clinical trials should address the bias effects of this experimental study.

2.
Sensors (Basel) ; 21(13)2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34208808

RESUMO

BACKGROUND: Kinematic analysis aimed toward scientific investigation or professional purposes is commonly unaffordable and complex to use. OBJECTIVE: The purpose of this study was to verify concurrent validation between a cycling-specific 3D camera and the gold-standard 3D general camera systems. METHODS: Overall, 11 healthy amateur male triathletes were filmed riding their bicycles with Vicon 3D cameras and the Retul 3D cameras for bike fitting analysis simultaneously. All 18 kinematic measurements given by the bike fitting system were compared with the same data given by Vicon cameras through Pearson correlation (r), intraclass correlation coefficients (ICC), standard error measurements (SEM), and Bland-Altman (BA) analysis. Confidence intervals of 95% are given. RESULTS: A very high correlation between cameras was found on six of 18 measurements. All other presented a high correlation between cameras (between 0.7 and 0.9). In total, six variables indicate a SEM of less than one degree between systems. Only two variables indicate a SEM higher than two degrees between camera systems. Overall, four measures indicate bias tendency according to BA. CONCLUSIONS: The cycling-specific led-emitting 3D camera system tested revealed a high or very high degree of correlation with the gold-standard 3D camera system used in laboratory motion capture. In total, 14 measurements of this equipment could be used in sports medicine clinical practice and even by researchers of cycling studies.


Assuntos
Ciclismo , Esportes , Fenômenos Biomecânicos , Humanos , Masculino , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA