Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 158
Filtrar
1.
Braz J Med Biol Res ; 57: e13360, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656076

RESUMO

This review provides the current state of knowledge regarding the use of nutritional nanocompounds on exercise performance. The reviewed studies used the following nanocompounds: resveratrol-loaded lipid nanoparticles, folic acid into layered hydroxide nanoparticle, redox-active nanoparticles with nitroxide radicals, and iron into liposomes. Most of these nutritional nanocompounds seem to improve performance in endurance exercise compared to the active compound in the non-nanoencapsulated form and/or placebo. Nutritional nanocompounds also induced the following physiological and metabolic alterations: 1) improved antioxidant activity and reduced oxidative stress; 2) reduction in inflammation status; 3) maintenance of muscle integrity; 4) improvement in mitochondrial function and quality; 5) enhanced glucose levels during exercise; 6) higher muscle and hepatic glycogen levels; and 7) increased serum and liver iron content. However, all the reviewed studies were conducted in animals (mice and rats). In conclusion, nutritional nanocompounds are a promising approach to improving exercise performance. As the studies using nutritional nanocompounds were all conducted in animals, further studies in humans are necessary to better understand the application of nutritional nanocompounds in sport and exercise science.


Assuntos
Condicionamento Físico Animal , Animais , Condicionamento Físico Animal/fisiologia , Nanotecnologia , Nanopartículas , Exercício Físico/fisiologia , Ratos , Estresse Oxidativo/efeitos dos fármacos , Antioxidantes/farmacologia , Resveratrol/farmacologia , Resveratrol/administração & dosagem , Camundongos
2.
Braz J Med Biol Res ; 57: e13102, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38451607

RESUMO

The present study investigated the reliability and sensitivity of a wearable near-infrared spectroscopy (wNIRS) device in moderate and heavy exercise intensity domains. On three separate days, eleven males performed an incremental test to exhaustion, and in the following visits, four submaximal constant-load bouts (i.e., test and retest) were performed in the moderate-intensity domain (100 and 130 W) and heavy-intensity domain (160 and 190 W). The local tissue oxygen saturation index (SmO2) and pulmonary oxygen uptake (V̇O2) were measured continuously. The absolute SmO2 and V̇O2 values and the change (Δ) from the 3rd to 6th min of exercise were calculated. There was good reliability for SmO2 measurements, as indicated by the high intraclass correlation coefficient analysis (ICC ≥0.84 for all) and low coefficient of variation between the two trials (CV ≤4.1% for all). Steady-state responses were observed for SmO2 and V̇O2 from the 3rd to the 6th min in the two moderate-intensity bouts (P>0.05), whereas SmO2 decreased and V̇O2 increased from the 3rd to the 6th min in the two heavy-intensity bouts (P<0.05). Together, these findings suggested that the SmO2 measured with a wNIRS device is reliable and sensitive to track local metabolic changes provoked by slight increments in exercise intensity.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho , Dispositivos Eletrônicos Vestíveis , Masculino , Humanos , Reprodutibilidade dos Testes , Terapia por Exercício , Exercício Físico
3.
Braz. j. med. biol. res ; 57: e13360, fev.2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1557306

RESUMO

Abstract This review provides the current state of knowledge regarding the use of nutritional nanocompounds on exercise performance. The reviewed studies used the following nanocompounds: resveratrol-loaded lipid nanoparticles, folic acid into layered hydroxide nanoparticle, redox-active nanoparticles with nitroxide radicals, and iron into liposomes. Most of these nutritional nanocompounds seem to improve performance in endurance exercise compared to the active compound in the non-nanoencapsulated form and/or placebo. Nutritional nanocompounds also induced the following physiological and metabolic alterations: 1) improved antioxidant activity and reduced oxidative stress; 2) reduction in inflammation status; 3) maintenance of muscle integrity; 4) improvement in mitochondrial function and quality; 5) enhanced glucose levels during exercise; 6) higher muscle and hepatic glycogen levels; and 7) increased serum and liver iron content. However, all the reviewed studies were conducted in animals (mice and rats). In conclusion, nutritional nanocompounds are a promising approach to improving exercise performance. As the studies using nutritional nanocompounds were all conducted in animals, further studies in humans are necessary to better understand the application of nutritional nanocompounds in sport and exercise science.

4.
Braz. j. med. biol. res ; 57: e13102, fev.2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1534066

RESUMO

The present study investigated the reliability and sensitivity of a wearable near-infrared spectroscopy (wNIRS) device in moderate and heavy exercise intensity domains. On three separate days, eleven males performed an incremental test to exhaustion, and in the following visits, four submaximal constant-load bouts (i.e., test and retest) were performed in the moderate-intensity domain (100 and 130 W) and heavy-intensity domain (160 and 190 W). The local tissue oxygen saturation index (SmO2) and pulmonary oxygen uptake (V̇O2) were measured continuously. The absolute SmO2 and V̇O2 values and the change (Δ) from the 3rd to 6th min of exercise were calculated. There was good reliability for SmO2 measurements, as indicated by the high intraclass correlation coefficient analysis (ICC ≥0.84 for all) and low coefficient of variation between the two trials (CV ≤4.1% for all). Steady-state responses were observed for SmO2 and V̇O2 from the 3rd to the 6th min in the two moderate-intensity bouts (P>0.05), whereas SmO2 decreased and V̇O2 increased from the 3rd to the 6th min in the two heavy-intensity bouts (P<0.05). Together, these findings suggested that the SmO2 measured with a wNIRS device is reliable and sensitive to track local metabolic changes provoked by slight increments in exercise intensity.

5.
Eur Arch Paediatr Dent ; 24(3): 409-416, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37052793

RESUMO

PURPOSE: Analyze the association between parental stress and dental caries experience in adolescents in southern Brazil using data from the Pelotas 2004 Birth Cohort. METHODS: Interviews and oral health examinations for the determination of the main exposure and outcome of the study were performed in the homes of the adolescents. The outcome was dental caries experience in the permanent dentition analyzed using the Decayed, Missing and Filling Surfaces (DMFS) index. The main exposure was parental stress measured using the Parenting Stress Index-Short Form administered to the parents of the adolescents. Demographic/socioeconomic characteristics, oral health characteristics and oral health-related quality of life were considered potential confounding factors. Negative binomial regressions estimated mean ratios (MR) and 95% confidence intervals (CI). RESULTS: Nine hundred ninety-six adolescents were evaluated at 12 and 13 years of age. The prevalence of dental caries experience in the adolescents was 36.9% (95% CI: 33.8-40.0) and 15.1% (95% CI: 12.8-17.3) of the parents had parental stress. After adjusting for confounding factors, parental stress was associated with a higher mean number of decayed, missing and filling surfaces in the adolescents (MR = 1.10; 95% CI: 1.01-1.26; p = 0.045). CONCLUSION: Adolescents of parents with parental stress have more dental caries experience compared to those whose parents do not have parental stress.


Assuntos
Cárie Dentária , Humanos , Adolescente , Cárie Dentária/epidemiologia , Estudos de Coortes , Brasil/epidemiologia , Qualidade de Vida , Índice CPO , Pais
6.
Braz J Med Biol Res ; 55: e12351, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36629524

RESUMO

In cycling, there is a body of evidence that supports that an all-out start strategy is superior to an even-pacing strategy, but it is unknown whether an all-out start strategy is superior to a self-paced strategy. In the present study, we investigated the effects of three different pacing strategies on 4-km cycling time trial performance. After preliminary trials (familiarization trials and a baseline 4-km cycling time trial), in a randomized and counterbalanced order, twelve male cyclists (32.3±7.2 years old, maximum rate of O2 uptake (V̇O2peak) 4.3±0.4 L/min) completed: 1) a self-paced 4-km cycling time trial; 2) an all-out start (∼10 s), followed by maintenance of the average baseline trial power for the first km and self-paced cycling for the remaining trial (all-out+mean); and 3) an all-out start (∼10 s), followed by a power 5% above the average baseline trial power for the first km and self-paced cycling for the remaining trial (all-out+5%mean). Although there was a significant interaction between power and distance (P=0.001) with different power distribution profiles throughout the trial, there was no significant difference (P=0.99) between the three strategies for overall exercise performance (self-paced 379.8±13.9 s, all-out+mean 380.0±16.0 s, and all-out+5%mean 380.2±11.5 s). Oxygen uptake, rating of perceived effort, and heart rate were also similar across the pacing strategies. Different all-out start strategies did not confer additional benefits to performance compared to a self-paced strategy.


Assuntos
Desempenho Atlético , Exercício Físico , Adulto , Humanos , Masculino , Desempenho Atlético/fisiologia , Ciclismo/fisiologia , Exercício Físico/fisiologia , Teste de Esforço , Frequência Cardíaca/fisiologia , Consumo de Oxigênio/fisiologia
7.
Braz J Med Biol Res ; 55: e12383, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36383804

RESUMO

The aim of this study was to describe the muscle function, architecture, and composition of long-distance master runners, and verify the association between age and these variables. Additionally, different clusters of runners were compared based on age and training variables. Forty male runners (≥50 years) reported their training routine and had their muscle function evaluated through maximum knee extensor isometric peak torque (PT) assessed with an isokinetic dynamometer. The cross-sectional area (CSA), pennation angle (PA), fascicle length (FL), muscle thickness (MT), and echo intensity (EI) were evaluated through ultrasound (muscle architecture and composition). The participants were 58.7±6.2 years old and had been training for 18.4±10.3 years, 4 sessions/week with 298.8±164.7 min/week of training. The absolute torque was 226.92±63.44 N·m, and the specific torque (PT/CSA) was 7.29±3.78 N·m/cm2. Regarding muscle architecture, the phase angle was 17.34±4°, the fascicle angle 6.78±1.04 cm, muscle thickness 2.93±0.56 cm, and the cross-sectional area 21.24±5.88 cm2. Concerning muscle composition, the master runners showed echo intensity values of 62.05±11.68 AU. The analysis demonstrated a weak and negative association between age and some muscle architecture variables (CSA and MT) and muscle function (PT). No association was verified between age and muscle composition (EI). Age partially explained CSA, MT, and muscle function changes (13, 11, and 14%, respectively). Participants' high level of physical training might have contributed to the low association between these variables and the lack of association with muscle composition.


Assuntos
Joelho , Músculo Esquelético , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Transversais , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Joelho/fisiologia , Torque , Articulação do Joelho , Força Muscular/fisiologia , Músculo Quadríceps
8.
Braz J Med Biol Res ; 55: e11901, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35239783

RESUMO

We examined whether endurance performance and neuromuscular fatigue would be affected by caffeine ingestion during closed- and open-loop exercises. Nine cyclists performed a closed-loop (4,000-m cycling time trial) and an open-loop exercise (work rate fixed at mean power of the closed-loop trial) 60 min after ingesting caffeine (CAF, 5 mg/kg) or placebo (PLA, cellulose). Central and peripheral fatigue was quantified via pre- to post-exercise decrease in quadriceps voluntary activation and potentiated twitch force, respectively. Test sensitivity for detecting caffeine-induced improvements in exercise performance was calculated as the mean change in time divided by the error of measurement. Caffeine ingestion reduced the time of the closed-loop trial (PLA: 375.1±14.5 s vs CAF: 368.2±14.9 s, P=0.024) and increased exercise tolerance during the open-loop trial (PLA: 418.2±99.5 s vs CAF: 552.5±106.5 s, P=0.001), with similar calculated sensitivity indices (1.5, 90%CI: 0.7-2.9 vs 2.8, 90%CI: 1.9-5.1). The reduction in voluntary activation was more pronounced (P=0.019) in open- (-6.8±8.3%) than in closed-loop exercises (-1.9±4.4%), but there was no difference between open- and closed-loop exercises for the potentiated twitch force reduction (-25.6±12.8 vs -26.6±12.0%, P>0.05). Caffeine had no effect on central and peripheral fatigue development in either mode of exercise. In conclusion, caffeine improved endurance performance in both modes of exercise without influence on post-exercise central and peripheral fatigue, with the open-loop exercise imposing a greater challenge to central fatigue tolerance.


Assuntos
Ciclismo , Cafeína , Método Duplo-Cego , Exercício Físico/fisiologia , Terapia por Exercício , Humanos , Músculo Quadríceps
9.
Braz. j. med. biol. res ; 55: e12351, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1420742

RESUMO

In cycling, there is a body of evidence that supports that an all-out start strategy is superior to an even-pacing strategy, but it is unknown whether an all-out start strategy is superior to a self-paced strategy. In the present study, we investigated the effects of three different pacing strategies on 4-km cycling time trial performance. After preliminary trials (familiarization trials and a baseline 4-km cycling time trial), in a randomized and counterbalanced order, twelve male cyclists (32.3±7.2 years old, maximum rate of O2 uptake (V̇O2peak) 4.3±0.4 L/min) completed: 1) a self-paced 4-km cycling time trial; 2) an all-out start (∼10 s), followed by maintenance of the average baseline trial power for the first km and self-paced cycling for the remaining trial (all-out+mean); and 3) an all-out start (∼10 s), followed by a power 5% above the average baseline trial power for the first km and self-paced cycling for the remaining trial (all-out+5%mean). Although there was a significant interaction between power and distance (P=0.001) with different power distribution profiles throughout the trial, there was no significant difference (P=0.99) between the three strategies for overall exercise performance (self-paced 379.8±13.9 s, all-out+mean 380.0±16.0 s, and all-out+5%mean 380.2±11.5 s). Oxygen uptake, rating of perceived effort, and heart rate were also similar across the pacing strategies. Different all-out start strategies did not confer additional benefits to performance compared to a self-paced strategy.

10.
Braz. j. med. biol. res ; 55: e12383, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403909

RESUMO

The aim of this study was to describe the muscle function, architecture, and composition of long-distance master runners, and verify the association between age and these variables. Additionally, different clusters of runners were compared based on age and training variables. Forty male runners (≥50 years) reported their training routine and had their muscle function evaluated through maximum knee extensor isometric peak torque (PT) assessed with an isokinetic dynamometer. The cross-sectional area (CSA), pennation angle (PA), fascicle length (FL), muscle thickness (MT), and echo intensity (EI) were evaluated through ultrasound (muscle architecture and composition). The participants were 58.7±6.2 years old and had been training for 18.4±10.3 years, 4 sessions/week with 298.8±164.7 min/week of training. The absolute torque was 226.92±63.44 N·m, and the specific torque (PT/CSA) was 7.29±3.78 N·m/cm2. Regarding muscle architecture, the phase angle was 17.34±4°, the fascicle angle 6.78±1.04 cm, muscle thickness 2.93±0.56 cm, and the cross-sectional area 21.24±5.88 cm2. Concerning muscle composition, the master runners showed echo intensity values of 62.05±11.68 AU. The analysis demonstrated a weak and negative association between age and some muscle architecture variables (CSA and MT) and muscle function (PT). No association was verified between age and muscle composition (EI). Age partially explained CSA, MT, and muscle function changes (13, 11, and 14%, respectively). Participants' high level of physical training might have contributed to the low association between these variables and the lack of association with muscle composition.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA