Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 12(11)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36359594

RESUMO

INTRODUCTION: Lung Ultrasonography (LUS) is a fast technique for the diagnosis of patients with respiratory syndromes. B-lines are seen in response to signal reverberations and amplifications into sites with peripheral lung fluid concentration or septal thickening. Mathematical models are commonly applied in biomedicine to predict biological responses to specific signal parameters. OBJECTIVE: This study proposes a Finite-Element numerical model to simulate radio frequency ultrasonic lines propagated from normal and infiltrated lung structures. For tissue medium, a randomized inhomogeneous data method was used. The simulation implemented in COMSOL® used Acoustic Pressure and Time-Explicit models, which are based on the discontinuous Galerkin method (dG). RESULTS: The RF signals, processed in MATLAB®, resulted in images of horizontal A-lines and vertical B-lines, which were reasonably similar to real images. DISCUSSION: The use of inhomogeneous materials in the model was good enough to simulate the scattering response, similar to others in the literature. The model is useful to study the impact of the lung infiltration characteristics on the appearance of LUS images.

2.
Rev. bras. eng. biomed ; 30(1): 3-10, Mar. 2014. ilus, tab
Artigo em Inglês | LILACS | ID: lil-707132

RESUMO

INTRODUCTION: Ultrasound Transit-Time flowmeters are based on the fact that the time required for an ultrasound pulse to propagate through a given distance in a moving medium is a function of the vectorial sum of pulse propagation velocity and medium velocity. The most common application of this flowmeter in medicine is in the evaluation of blood flow in arteries and veins during heart vascular surgery. The present article describes the design, construction and evaluation of a flow phantom for transit-time flowmeters calibration. METHODS: Basically, it is a hydraulic circuit containing degassed and distilled water. In such a circuit, a constant differential water level is established between two columns that are interconnected by tubes with defined resistance, which determines a known flow rate. A basic theoretical model to estimate the system Reynolds Number and resistance was developed. RESULTS: A flow range between 4.43 ± 0.18 ml.min-1 and 106.88 ± 0.27 ml.min-1 was found to be compatible with physiological values in small vessels. The pressure range was between 0.20 ± 0.03 cmH2O and 12.53 ± 0.07 cmH2O, and the larger Reynolds Number was 1134.07. Experimental and theoretical resistance values were similar. CONCLUSION: A reproducible phantom was designed and built to be assembled with standard low-cost materials and is capable of generating adjustable and continuous flows that can be used to calibrate TTFM systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA