Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Catheter Cardiovasc Interv ; 98(5): E746-E757, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33555107

RESUMO

BACKGROUND: There is a rising trend for transcatheter aortic valve implantation (TAVI) in bicuspid aortic stenosis patients. Data on the use of self-expandable (SEV) vs. balloon-expandable (BEV) valves in these patients are scarce. Therefore, we systematically compared clinical outcomes in bicuspid aortic stenosis patients treated with SEV and BEV. METHODS: Data were extracted from PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, Google Scholar and reference lists of relevant articles. Eight studies published from 2013 to 2020 including a total of 1,080 patients (BEV: n = 620; SEV: n = 460) were selected. Primary endpoints were procedural, 30-day and 1-year mortality. Secondary endpoints were new pacemaker implantation, annular rupture, coronary obstruction, moderate-to-severe paravalvular leak, need of second valve, stroke and acute kidney injury. RESULTS: We found no statistically significant difference in mortality between patients treated with BEV vs. SEV during index procedure, at 30 days and at 1 year. BEVs showed a statistically significant higher risk of annulus rupture (2.5%) in comparison with SEV (0%) (OR 5.81 [95% CI, 3.78-8.92], p < .001). New generation BEVs were also associated with significantly less paravalvular leak when compared to new generation SEVs (OR 0.08 [95% CI, 0.02-0.35], p = .001). CONCLUSIONS: This meta-analysis of observational studies of TAVI for bicuspid valves, showed no difference in short- and mid-term TAVI mortality with BEVs and SEVs. BEVs presented a higher risk of annular rupture in comparison with SEV.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Constrição Patológica , Humanos , Estudos Observacionais como Assunto , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 97(1): E95-E103, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32301250

RESUMO

INTRODUCTION: Few data exist regarding the late clinical impact of the Selvester score prediction of myocardial fibrosis after transcatheter aortic valve replacement (TAVR). This study evaluated the predictive power of the Selvester score on survival in patients with aortic stenosis (AS) undergoing TAVR. METHODS AND RESULTS: Patients with severe AS who had preoperative electrocardiograms were included. Clinical follow-up was obtained retrospectively. The primary endpoint was all-cause mortality. Secondary endpoints were cardiovascular death and major adverse cardiac events (MACEs). Two-hundred twenty-eight patients were included (mean age, 81.5 ± 7.4 years; women, 58.3%). Deceased patients had a higher mean score (4.6 ± 3.2 vs. 1.4 ± 1.3; p < .001). At a mean follow-up of 36.2 ± 21.2 months, the Selvester score was independently associated with all-cause mortality (hazard ratio [HR], 1.65; 95% confidence interval [CI], 1.48-1.84; p < .001), cardiovascular death (HR, 1.59; 95% CI, 1.38-1.74; p < .001), and MACE (HR, 1.55; 95% CI, 1.30-1.68; p < .001). After 5 years, the mortality risk was incrementally related to the Selvester score. The involvement of the inferior wall of the left ventricle was a lower mortality risk factor (HR, 0.42; 95% CI, 0.18-0.98; p = .046). For a Selvester score of 3, the area under the curve showed 0.92, 0.94, and 0.86 (p < .001), respectively, for 1, 2, and 3 years. CONCLUSIONS: Elevated Selvester scores increase the risk of poor outcomes in patients with AS undergoing TAVR. The involvement of the anterior or lateral wall presents worse prognosis.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 97(1): 167-174, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32445607

RESUMO

OBJECTIVES: The aim of the study was to evaluate mid- to late clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) with Acurate neo™ (Boston Scientific, Boston, MA). BACKGROUND: TAVR is an established treatment for aortic stenosis (AS). Few data exist on mid- to long-term outcomes and durability after new-generation valves. METHODS: All consecutive patients (n = 104) who underwent Acurate neo™ implantation from 2012 to 2018 were included. Follow-up was systematically performed at 1, 6, 12, and 24 months and yearly thereafter. Outcomes were reported according to VARC-2, and structural valve deterioration (SVD) or bioprosthetic valve failure defined accordingly to new definitions. RESULTS: Mean age was 82 ± 5.4 years, 56.7% were female and the Society of Thoracic Surgeons score for mortality was 5.9 ± 4%. Patients were followed for a median of 3 years (1,092 days; IQR 1.5-4 years), and the maximum follow-up was 7 years. All-cause mortality values at 1 and 5 years were 8.5% and 40.5%, respectively. No relevant changes in mean gradient and orifice area occurred (7.9 ± 3.8 mmHg and 1.9 ± 0.3 cm2 at 1 year; 6.6 ± 2.1 mmHg and 1.8 ± 0.3 cm2 at 5 years), and there was a significant rate of paravalvular leaks resolution at 1, 2, and 3 years (p = .004; p < .001; p < .001, respectively). None of the patients had leaflet thrombosis or endocarditis. One patient developed SVD at 84 months. CONCLUSIONS: Acurate neo™ was associated with sustained echocardiographic results. Reassuring mid- to long-term outcomes was observed in this cohort of elderly patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Trends Cardiovasc Med ; 31(7): 435-445, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33065313

RESUMO

Aortic stenosis (AS) remains one of the most common valvular heart diseases, with enormous impact on patient survival. Over the past years, transcatheter aortic valve implantation (TAVI) has become a reality worldwide, offering a less invasive method to treat AS. Apart from the classical indications for aortic valve disease, recent studies tried to address unanswered questions for TAVI - asymptomatic severe AS, bicuspid aortic valves and moderate AS in patients with heart failure. This review discusses the rationale of those possible indications, pitfalls and current evidence in the medical literature.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Insuficiência Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Braz J Cardiovasc Surg ; 35(2): 127-133, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32369290

RESUMO

OBJECTIVE: To evaluate the hemodynamic performance (i.e., gradients and paravalvular leakage [PVL]) of the new and experimental Braile Inovare® Proseal. Additionally, we aimed to assess pre and postoperatively the aortic annulus and the transcatheter prosthesis using multislice computed tomography (MSCT). METHODS: Patients were selected by a multidisciplinary heart team and referred for transcatheter aortic valve replacement (TAVR). MSCT was performed before and after surgery. Measurements of the aortic valve and prosthesis were conducted and correlated with the valve gradient and residual PVL. RESULTS: Twenty-one patients were selected for the protocol. Patients had a mean age of 79 years and 38% of them were of female sex. The mean EuroSCORE II value was 12.5%±10.8. Mean gradient was reduced from 45.8±11.04 mmHg to 5.59±2.61 mmHg and there were no instances of PVL worse than mild. There were no cases of coronary obstruction or procedural death. Circularity was present in all prostheses evaluated. Circularity indexes for the prostheses were: inflow 0.05±0.03, middle third 0.04±0.02, and outflow 0.04±0.02 (P=0.08). The mean distance between the prosthesis and the left and right coronary ostia were 14.8 mm±3.3 and 17.3 mm±3, respectively. Oversizing was appropriate with a mean of 22.14%±6%. CONCLUSION: Braile Inovare® Proseal transcatheter device has demonstrated low gradients with low rates of PVL. Oversizing by annular measurements was adequate. MSCT was adequate to evaluate device sizing and has demonstrated preserved expansibility and circularity in the evaluated cases.


Assuntos
Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica , Estenose da Valva Aórtica , Cateterismo Cardíaco , Feminino , Hemodinâmica , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
7.
Catheter. cardiovasc. interv ; 97(1): 167-174, May. 2020. graf, ilus, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1145584

RESUMO

Abstract Objectives: The aim of the study was to evaluate mid- to late clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) with A curate neo™ (Boston Scientific, Boston, MA). Background: TAVR is an established treatment for aortic stenosis (AS). Few data exist on mid- to long-term outcomes and durability after new-generation valves. Methods: All consecutive patients (n = 104) who underwent A curate neo™ implantation from 2012 to 2018 were included. Follow-up was systematically performed at 1, 6, 12, and 24 months and yearly thereafter. Outcomes were reported according to VARC-2, and structural valve deterioration (SVD) or bioprosthetic valve failure defined accordingly to new definitions. Results: Mean age was 82 ± 5.4 years, 56.7% were female and the Society of Thoracic Surgeons score for mortality was 5.9 ± 4%. Patients were followed for a median of 3 years (1,092 days; IQR 1.5­4 years), and the maximum follow-up was 7 years. All-cause mortality values at 1 and 5 years were 8.5% and 40.5%, respectively. No relevant changes in mean gradient and orifice area occurred (7.9 ± 3.8 mmHg and 1.9 ± 0.3 cm2 at 1 year; 6.6 ± 2.1 mmHg and 1.8 ± 0.3 cm2 at 5 years), and there was a significant rate of paravalvular leaks resolution at 1, 2, and 3 years (p = .004; p < .001; p < .001, respectively). None of the patients had leaflet thrombosis or endocarditis. One patient developed SVD at 84 months. Conclusions: A curate neo™ was associated with sustained echocardiographic results. Reassuring mid- to long-term outcomes was observed in this cohort of elderly patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Ecocardiografia
8.
Catheter. cardiovasc. interv ; 97(1): 95-103, May. 2020. graf., tab.
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1248171

RESUMO

INTRODUCTION: Few data exist regarding the late clinical impact of the Selvester score prediction of myocardial fibrosis after transcatheter aortic valve replacement (TAVR). This study evaluated the predictive power of the Selvester score on survival in patients with aortic stenosis (AS) undergoing TAVR. METHODS And Results: Patients with severe AS who had preoperative electrocardiograms were included. Clinical follow-up was obtained retrospectively. The primary endpoint was all-cause mortality. Secondary endpoints were cardiovascular death and major adverse cardiac events (MACEs). Two-hundred twenty-eight patients were included (mean age, 81.5 ± 7.4 years; women, 58.3%). Deceased patients had a higher mean score (4.6 ± 3.2 vs. 1.4 ± 1.3; p < .001). At a mean follow-up of 36.2 ± 21.2 months, the Selvester score was independently associated with all-cause mortality (hazard ratio [HR], 1.65; 95% confidence interval [CI], 1.48-1.84; p < .001), cardiovascular death (HR, 1.59; 95% CI, 1.38-1.74; p < .001), and MACE (HR, 1.55; 95% CI, 1.30-1.68; p < .001). After 5 years, the mortality risk was incrementally related to the Selvester score. The involvement of the inferior wall of the left ventricle was a lower mortality risk factor (HR, 0.42; 95% CI, 0.18-0.98; p = .046). For a Selvester score of 3, the area under the curve showed 0.92, 0.94, and 0.86 (p < .001), respectively, for 1, 2, and 3 years. CONCLUSIONS: Elevated Selvester scores increase the risk of poor outcomes in patients with AS undergoing TAVR. The involvement of the anterior or lateral wall presents worse prognosis.


Assuntos
Estenose da Valva Aórtica , Mortalidade
9.
JACC Case Rep ; 2(3): 480-485, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34317269

RESUMO

We describe the endovascular management of a middle-aged woman who developed a bleeding suprasternal fistula after conventional aortic valve replacement. The patient's condition was considered inoperable. A customized stent attached to a transcatheter valve was successfully used to treat the individual, this being the first-in-human case of the promising Endo-Bentall procedure. (Level of Difficulty: Advanced.).

10.
Rev. bras. cir. cardiovasc ; 35(2): 127-133, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1101470

RESUMO

Abstract Objective: To evaluate the hemodynamic performance (i.e., gradients and paravalvular leakage [PVL]) of the new and experimental Braile Inovare® Proseal. Additionally, we aimed to assess pre and postoperatively the aortic annulus and the transcatheter prosthesis using multislice computed tomography (MSCT). Methods: Patients were selected by a multidisciplinary heart team and referred for transcatheter aortic valve replacement (TAVR). MSCT was performed before and after surgery. Measurements of the aortic valve and prosthesis were conducted and correlated with the valve gradient and residual PVL. Results: Twenty-one patients were selected for the protocol. Patients had a mean age of 79 years and 38% of them were of female sex. The mean EuroSCORE II value was 12.5%±10.8. Mean gradient was reduced from 45.8±11.04 mmHg to 5.59±2.61 mmHg and there were no instances of PVL worse than mild. There were no cases of coronary obstruction or procedural death. Circularity was present in all prostheses evaluated. Circularity indexes for the prostheses were: inflow 0.05±0.03, middle third 0.04±0.02, and outflow 0.04±0.02 (P=0.08). The mean distance between the prosthesis and the left and right coronary ostia were 14.8 mm±3.3 and 17.3 mm±3, respectively. Oversizing was appropriate with a mean of 22.14%±6%. Conclusion: Braile Inovare® Proseal transcatheter device has demonstrated low gradients with low rates of PVL. Oversizing by annular measurements was adequate. MSCT was adequate to evaluate device sizing and has demonstrated preserved expansibility and circularity in the evaluated cases.


Assuntos
Humanos , Masculino , Feminino , Idoso , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Estenose da Valva Aórtica , Desenho de Prótese , Volume Sistólico , Cateterismo Cardíaco , Função Ventricular Esquerda , Resultado do Tratamento , Tomografia Computadorizada Multidetectores , Hemodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA