Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 160
Filtrar
1.
Oper Dent ; 47(6): 630-639, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36149436

RESUMO

OBJECTIVE: This study aimed to evaluate the external and internal adaptations of cervical restorations using different restorative techniques. METHODS: Forty extracted and intact human premolars received standardized cervical preparations to simulate non-carious cervical lesions. The teeth were randomly divided into four groups (n=10) according to the restorative technique: D, direct composite restoration without a base (Palfique LX5, Tokuyama Dental Corp Inc, Tokyo, Japan); DB, direct composite restoration with a flowable composite liner (Estelite Flow Quick -High Flow, Tokuyama Dental Corp Inc); DI, direct-indirect composite restoration bonded with flowable composite; and I, indirect restoration bonded with flowable composite. Marginal adaptation of the restorations was observed in different segments of the margins using a scanning electron microscope. Analyses of internal adaptation were performed using micro-computed tomography. The Kruskal-Wallis and Mann-Whitney tests were used for statistical analysis of the data (α=5%). RESULTS: No significant differences were found in the marginal adaptation of the groups (p>0.05), although a significantly higher percentage of continuous margin was found in the proximal segment than in the cervical segment (p<0.05). No significant differences were detected between the groups in terms of internal adaptation (p>0.05). CONCLUSION: All the restorative techniques evaluated for the restoration of cervical lesions performed similarly in terms of marginal and internal adaptation.


Assuntos
Preparo da Cavidade Dentária , Restauração Dentária Permanente , Humanos , Resinas Compostas/uso terapêutico , Forramento da Cavidade Dentária , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Microtomografia por Raio-X
2.
Arq. bras. med. vet. zootec. (Online) ; 74(6): 1017-1023, 2022. tab
Artigo em Inglês | VETINDEX | ID: biblio-1416132

RESUMO

Acute kidney injury (AKI) is defined as the rapid decline in kidney function. Its development is related to critical clinical statuses, such as sepsis, complicated post-surgical recovery, and infectious diseases. Serum cystatin C (CysC) has the best correlation with the glomerular filtration rate. Ultrasonography stands out because it is highly accessible and can be done at the bedside. Twenty-eight dogs admitted to the intensive care unit with serum creatinine values <1.6 mg/dL and at-risk factors of AKI development were selected. CysC measurements and ultrasound assessments were performed daily for 72 hours. Using CysC dosage, 22/28 animals (78.6%) were considered to have AKI, and 17/22 had ultrasound compatible with AKI changes, demonstrating moderate agreement with CysC dosage. Increased cortical renal echogenicity is the most prevalent alteration in critically ill patients and is correlated with serum increases in CysC and is associated with renal structural damage.


A injúria renal aguda (IRA) é definida como o declínio rápido da função renal. Seu desenvolvimento está relacionado a quadros clínicos críticos, como sepse, pós-operatório complicado e doenças infecciosas. A cistatina C sérica (CisC) tem melhor correlação com taxa de filtração glomerular. A ultrassonografia se destaca por ser altamente acessível e pode ser realizada à beira do leito. Foram selecionados 28 cães, internados em unidade de terapia intensiva, com valores de creatinina sérica <1,6mg/dL e fatores de risco para o desenvolvimento de IRA. Medições de CisC e avaliações ultrassonográficas foram realizadas diariamente por 72 horas. Utilizando-se a dosagem de CisC, 22/28 animais (78,6%) foram considerados portadores de IRA e 17/22 apresentaram ultrassom compatível com alterações de IRA, demonstrando concordância moderada com a dosagem de CisC. O aumento da ecogenicidade cortical renal é a alteração mais prevalente em pacientes críticos, está correlacionado com aumentos séricos de CisC e associado a dano estrutural renal.


Assuntos
Animais , Cães , Biomarcadores/análise , Cistatina C/sangue , Injúria Renal Aguda/veterinária , Rim/diagnóstico por imagem , Diagnóstico Precoce , Nefropatias/veterinária
3.
Int Endod J ; 54(8): 1212-1220, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33826773

RESUMO

AIM: To determine the anatomical reasons for sodium hypochlorite (NaOCl) accidents by testing whether this mishap is likely to occur in cases where the anatomical apex of the teeth fenestrates the overlying buccal cortical alveolar bone, allowing NaOCl to gain direct access to buccal soft tissues. METHODOLOGY: Following a cross-sectional, nonrandomized design, 13 patients who suffered unintentional NaOCl accidents whilst undergoing root canal treatment were included. After remission of symptoms, the root canals were fully irrigated with an innocuous radiopaque solution (saline diluted Claritrast 300) and subsequently CBCT scanned to create a 3D-map of the periapex and tracking of the irrigant pathway throughout the periapical tissues. An extra group of five control patients, who underwent root canal treatment with no NaOCl accident, was also CBCT-scanned after irrigation with the tracking radiopaque solution. The anatomical relationship of the cortical bone and the root apex, as well as the distribution of irrigation solution in the periapical tissue, was associated with patients undergoing a NaOCl accident or not, using a Fisher's exact test. RESULTS: The frequency of teeth with apical cortical fenestration was significantly higher in the NaOCl accident-positive group, compared to the negative (P < 0.001). All 13 accident-positive patients had an anatomical apex in direct contact with the buccal soft tissue via fenestration of the overlying cortical bone and direct contact of the foramen with the soft tissues. The radiopaque solution was distributed in the soft tissue in these cases. In contrast, accident-negative patients had no fenestration of the buccal cortical bone and the anatomical root apex was within the cancellous bone or within a bone-confined periapical lesion. The radiopaque solution was also found in the cancellous bone or the periapical lesion, but patients had no manifestations of a NaOCl accident. CONCLUSION: This quasi-experimental cross-sectional clinical study suggests that, in addition to the presence of the extruded NaOCl solution, a patent foramen that fenestrates the cortical bone merging into the mucosal tissue might constitute a risk for the clinical manifestation of a NaOCl accident. Preoperative 3D scans aid in anticipating when an accident is likely to occur.


Assuntos
Irrigantes do Canal Radicular , Hipoclorito de Sódio , Acidentes , Estudos Transversais , Cavidade Pulpar , Humanos , Preparo de Canal Radicular
4.
Int Endod J ; 54(6): 966-974, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33527413

RESUMO

AIM: To evaluate the correlation between the volume of dental hard tissues removed and the fracture resistance of mandibular molar teeth with ultraconservative (UltraAC) or traditional (TradAC) access cavity preparations. METHODOLOGY: Sixty recently extracted and intact mandibular first molars were scanned in a microcomputed tomographic (micro-CT) device, anatomically matched and assigned at random to 2 groups (n = 30), according to the access cavity type: UltraAC or TradAC. After access preparation, mesial and distal canals were prepared using Reciproc instruments and a new scan was taken. The volumes of pulp chamber and dental hard tissues in each specimen were measured before and after the experimental procedures, and the percentage volume reduction of hard tissues calculated for the entire tooth and for the crown separately. Teeth were then root filled, restored and subjected to fracture resistance tests in an universal testing machine. The force required to fracture was recorded in Newtons (N). The adherence of the variables to a Gaussian curve was verified using a Shapiro-Wilk test. Skewed data were analysed with nonparametric Wilcoxon signed rank or Spearman correlation tests, whilst the normally distributed data were analysed with a dependent samples Student t-test. Level of significance was set at 5%. RESULTS: Pre-operatively, no difference was observed between groups regarding the volume of pulp canal space or dental hard tissues (P > 0.05). After access preparation, volumes of the removed hard tissues from the entire tooth and from the crown were significantly greater in teeth prepared with TradAC than with UltraAC (P < 0.05). No significant difference was observed in the fracture resistance values between TradAC (902.9 ± 347.8 N) and UltraAC (948.7 ± 405.7 N) groups (P = 0.975). The Spearman test was unable to identify a correlation between fracture resistance and percentage volume of removed dental hard tissues in the entire root (P = 0.525, r = -0.084) or only in the crown (P = 0.152, r = -0.187). CONCLUSION: The volume of hard dental tissues removed, although greater in teeth with TradAC compared to UltraAC, did not correlate with the fracture resistance results, indicating that a minimally invasive access cavity did not increase the resistance of restored mandibular first molars to fracture.


Assuntos
Dente Molar , Preparo de Canal Radicular , Cavidade Pulpar , Dentina , Humanos , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Microtomografia por Raio-X
5.
6.
Int Endod J ; 53(11): 1506-1515, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32780440

RESUMO

AIM: To investigate a potential cause-effect relationship between dentinal microcracks and fracture resistance of mandibular incisors that had not been endodontically treated. METHODOLOGY: Sixty mandibular incisors with circular-shaped canals were selected based on micro-computed tomographic scans to create a homogeneous sample. The cross-sectional images of the specimens were screened to identify and quantify the presence of dentinal microcracks. Then, teeth were embedded in polystyrene resin and subjected to axial compressive loading using a universal testing machine. After fracture, the roots were re-scanned and fractography analysis was performed by inspection of 3D models to verify crack propagation. Spearman's rank correlation was used to assess the correlation between the number of microcracks and force required to fracture. RESULTS: Dentinal microcracks were detected in 79% of the specimens (n = 44). The incidence of microcracks varied between teeth from 6% to 42% of the total slices per sample (average of 14 ± 17%). The number of microcracks per sample varied from 0 to 1605, with an average of 412 ± 484 (median = 221 and IQR 25% = 15/75% = 658). The load at failure values varied from 227 to 924 N, with an average of 560.3 ± 168.1 N (median = 561 and IQR 25% = 458/75% = 694). The Spearman correlation coefficient (rho) equalled 0.065. CONCLUSIONS: There was no cause-effect relationship between the number of dentinal microcracks and the fracture resistance of nonendodontically treated mandibular incisors. The presence and quantity of microcracks did not make these roots more prone to fracture.


Assuntos
Preparo de Canal Radicular , Fraturas dos Dentes , Estudos Transversais , Dentina , Humanos , Laboratórios , Papel (figurativo) , Fraturas dos Dentes/diagnóstico por imagem , Fraturas dos Dentes/etiologia , Microtomografia por Raio-X
7.
Int Endod J ; 53(7): 974-985, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32159857

RESUMO

AIM: To introduce a new method to select anatomically matched teeth using micro-computed tomographic (micro-CT) technology. METHODOLOGY: Single-rooted mandibular incisors with a single root canal (n = 60) were selected and distributed into three experimental groups according to the method used for matching 10 pairs of teeth in each group. In group 1, the pairs of mandibular incisors were randomly selected from a pool of teeth. In group 2, teeth were paired based on the measurement of canal width 5 mm from the root apex using radiographs taken from buccolingual and mesiodistal directions. In group 3, teeth were scanned (pixel size of 14.25 µm) and pair-matched based on the anatomical aspects of the root canal, named aspect ratio (AR), volume and three-dimensional canal geometry. After allocating the specimens into groups 1 and 2, the teeth were scanned and the canal morphology evaluated as in group 3. A bivariate Pearson's regression analysis was performed correlating the individual AR values of each pair, and the correlation coefficient was used to estimate the strength of the pair-matching process. One-way anova post hoc Tukey's tests were applied for pairwise comparisons at a significance level of 5%. RESULTS: The micro-CT revealed that 100% of the samples had strong (80%) or very strong (20%) correlations with respect to AR values. Analysis of the radiographic method revealed strong correlation in two pairs (20%), but most of the samples had weak (30%) or negligible (30%) correlation coefficients. The randomization method resulted in three pairs (30%) with very strong correlations, whilst 50% had weak or negligible rates. A significant difference in correlation coefficients was observed in the micro-CT method compared to the other groups (P < 0.05), whilst no difference was detected between radiographic and randomized methods (P > 0.05). Eta-squared (η2 ) calculations demonstrated a very high effect size in the micro-CT group for selecting pairs (0.99) and lower effect sizes in the radiographic (0.67) and randomized (0.66) groups. CONCLUSIONS: Use of Micro-CT was able to provide better control of the confounding effect that anatomical variances in tooth morphology may have on the results in experiments with matched-pair design.


Assuntos
Cavidade Pulpar , Tratamento do Canal Radicular , Dente Pré-Molar , Incisivo , Microtomografia por Raio-X
8.
Int Endod J ; 53(3): 410-420, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31613994

RESUMO

AIM: To investigate the shaping and cleaning performance of the Clearsonic ultrasonic tip as a supplementary tool during the preparation of long oval-shaped root canals through micro-computed tomographic (micro-CT) imaging technology. The Reciproc M-Wire R40 instrument was used as a reference instrumentation technique for comparison. METHODOLOGY: Twenty mandibular incisors with single, straight and long oval-shaped canals were selected and pair-matched by micro-CT scanning. The root canals were prepared with Reciproc R25 and R40 instruments, scanned again in a micro-CT device and randomly allocated into one of the two experimental groups (n = 10), according to the supplementary debridement protocol used: Clearsonic or Reciproc R40 used in a brushing motion against buccal and lingual walls. Noninstrumented canal areas, accumulation of hard-tissue debris (AHTD) and volume of removed dentine were assessed using micro-CT imaging following the supplementary debridement protocols. Data were analysed statistically in two phases using a t-test with a significance level of 5%. RESULTS: In phase-1, there was a significant similarity between the samples regarding the evaluated micro-CT baseline parameters (P > 0.05), validating the anatomical similarity between the tooth pairs. In phase-2, there was a significant difference between the groups for canal volume, surface area, noninstrumented root canal walls and the amount of removed dentine for both absolute and percentage values (P < 0.05), but not for AHTD (P = 0.759). CONCLUSIONS: The Clearsonic tip outperformed the Reciproc R40 instrument as a supplementary debridement protocol as it was associated with significantly greater reduction of noninstrumented root canals walls and consequently a larger amount of removed dentine. Both groups performed similarly regarding the AHTD.


Assuntos
Preparo de Canal Radicular , Desbridamento , Cavidade Pulpar , Desenho de Equipamento , Ultrassom , Microtomografia por Raio-X
10.
Int Endod J ; 53(4): 440-446, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31622501

RESUMO

AIM: To evaluate the incidence of root dentinal microcracks after two extraction techniques through micro-computed tomographic (micro-CT) analysis. METHODOLOGY: Thirty pairs of premolars, extracted for orthodontic reasons, were assigned to two experimental groups, following a split-mouth design (n = 30): traumatic technique group (TTG) - teeth extracted following a conventional protocol using forceps, and an atraumatic technique group (ATG) - teeth extracted following an atraumatic technique protocol in which the root was gently detached from the periodontal ligament using a periotome. All teeth were immediately immersed in distilled water and scanned in a micro-CT device within 72 h following the extraction. The assessment of the images was completed on cross-section images by two masked evaluators. The Mann-Whitney test was used to assess the significant differences between the groups regarding the number of cross-sections displaying microcracks whilst the Fischer's exact test was used to assess differences in the frequency of specimens with defects (P < 0.05). RESULTS: A total of 52 750 micro-CT cross-sectional images were evaluated. A total of 352 cross-sections had at least one dentinal defect. Microcracks were observed in five teeth of the TTG group (n = 352 slices) and in two teeth of the ATG group (n = 103 slices). The statistical analysis used was unable to detect a significant difference between the groups in terms of the number of dentinal microcracks (P = 0.233) and in the frequency of teeth displaying microcracks (P = 0.424). CONCLUSION: A small number of sound teeth without endodontic treatment had dentinal microcracks regardless of the extraction technique applied. No difference was noticed between the traumatic and atraumatic techniques in the incidence of microcracks.


Assuntos
Preparo de Canal Radicular , Fraturas dos Dentes , Estudos Transversais , Dentina , Humanos , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA