1.
J Vasc Access ; 22(1): 34-41, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32406328

RESUMO

BACKGROUND: Short-term peripheral venous catheter-associated bloodstream infection rates have not been systematically studied in Asian countries, and data on peripheral venous catheter-associated bloodstream infections incidence by number of short-term peripheral venous catheter days are not available. METHODS: Prospective, surveillance study on peripheral venous catheter-associated bloodstream infections conducted from 1 September 2013 to 31 May 2019 in 262 intensive care units, members of the International Nosocomial Infection Control Consortium, from 78 hospitals in 32 cities of 8 countries in the South-East Asia Region: China, India, Malaysia, Mongolia, Nepal, Philippines, Thailand, and Vietnam. For this research, we applied definition and criteria of the CDC NHSN, methodology of the INICC, and software named INICC Surveillance Online System. RESULTS: We followed 83,295 intensive care unit patients for 369,371 bed-days and 376,492 peripheral venous catheter-days. We identified 999 peripheral venous catheter-associated bloodstream infections, amounting to a rate of 2.65/1000 peripheral venous catheter-days. Mortality in patients with peripheral venous catheter but without peripheral venous catheter-associated bloodstream infections was 4.53% and 12.21% in patients with peripheral venous catheter-associated bloodstream infections. The mean length of stay in patients with peripheral venous catheter but without peripheral venous catheter-associated bloodstream infections was 4.40 days and 7.11 days in patients with peripheral venous catheter and peripheral venous catheter-associated bloodstream infections. The microorganism profile showed 67.1% were Gram-negative bacteria: Escherichia coli (22.9%), Klebsiella spp (10.7%), Pseudomonas aeruginosa (5.3%), Enterobacter spp. (4.5%), and others (23.7%). The predominant Gram-positive bacteria were Staphylococcus aureus (11.4%). CONCLUSIONS: Infection prevention programs must be implemented to reduce the incidence of peripheral venous catheter-associated bloodstream infections.


Assuntos
Infecções Bacterianas/epidemiologia , Infecções Relacionadas a Cateter/epidemiologia , Cateterismo Periférico/efeitos adversos , Infecção Hospitalar/epidemiologia , Dispositivos de Acesso Vascular/efeitos adversos , Ásia/epidemiologia , Infecções Bacterianas/microbiologia , Infecções Bacterianas/mortalidade , Infecções Bacterianas/terapia , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/mortalidade , Infecções Relacionadas a Cateter/terapia , Cateterismo Periférico/mortalidade , Infecção Hospitalar/microbiologia , Infecção Hospitalar/mortalidade , Infecção Hospitalar/terapia , Mortalidade Hospitalar , Humanos , Incidência , Controle de Infecções , Tempo de Internação , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Crit Care Med ; 48(2): e87-e97, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31939807

RESUMO

OBJECTIVES: To assess the attitudes of practitioners with respect to net ultrafiltration prescription and practice among critically ill patients with acute kidney injury treated with renal replacement therapy. DESIGN: Multinational internet-assisted survey. SETTING: Critical care practitioners involved with 14 societies in 80 countries. SUBJECTS: Intervention: MEASUREMENT AND MAIN RESULTS:: Of 2,567 practitioners who initiated the survey, 1,569 (61.1%) completed the survey. Most practitioners were intensivists (72.7%) with a median duration of 13.2 years of practice (interquartile range, 7.2-22.0 yr). Two third of practitioners (71.0%; regional range, 55.0-95.5%) reported using continuous renal replacement therapy with a net ultrafiltration rate prescription of median 80.0 mL/hr (interquartile range, 49.0-111.0 mL/hr) for hemodynamically unstable and a maximal rate of 299.0 mL/hr (interquartile range, 200.0-365.0 mL/hr) for hemodynamically stable patients, with regional variation. Only a third of practitioners (31.5%; range, 13.7-47.8%) assessed hourly net fluid balance during continuous renal replacement therapy. Hemodynamic instability was reported in 20% (range, 20-38%) of patients and practitioners decreased the rate of fluid removal (70.3%); started or increased the dose of a vasopressor (51.5%); completely stopped fluid removal (35.8%); and administered a fluid bolus (31.6%), with significant regional variation. Compared with physicians, nurses were most likely to report patient intolerance to net ultrafiltration (73.4% vs 81.3%; p = 0.002), frequent interruptions (40.4% vs 54.5%; p < 0.001), and unavailability of trained staff (11.9% vs 15.6%; p = 0.04), whereas physicians reported unavailability of dialysis machines (14.3% vs 6.1%; p < 0.001) and costs associated with treatment as barriers (12.1% vs 3.0%; p < 0.001) with significant regional variation. CONCLUSIONS: Our study provides new knowledge about the presence and extent of international practice variation in net ultrafiltration. We also identified barriers and specific targets for quality improvement initiatives. Our data reflect the need for evidence-based practice guidelines for net ultrafiltration.


Assuntos
Injúria Renal Aguda/terapia , Terapia de Substituição Renal Contínua/métodos , Cuidados Críticos/métodos , Estado Terminal/terapia , Recursos Humanos em Hospital/estatística & dados numéricos , Terapia de Substituição Renal Contínua/efeitos adversos , Humanos , Ultrafiltração
3.
Am J Infect Control ; 38(2): 95-104.e2, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20176284

RESUMO

We report the results of the International Infection Control Consortium (INICC) surveillance study from January 2003 through December 2008 in 173 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study, using Centers for Disease Control and Prevention (CDC) US National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infection, we collected prospective data from 155,358 patients hospitalized in the consortium's hospital ICUs for an aggregate of 923,624 days. Although device utilization in the developing countries' ICUs was remarkably similar to that reported from US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were markedly higher in the ICUs of the INICC hospitals: the pooled rate of central venous catheter (CVC)-associated bloodstream infections (BSI) in the INICC ICUs, 7.6 per 1000 CVC-days, is nearly 3-fold higher than the 2.0 per 1000 CVC-days reported from comparable US ICUs, and the overall rate of ventilator-associated pneumonia (VAP) was also far higher, 13.6 versus 3.3 per 1000 ventilator-days, respectively, as was the rate of catheter-associated urinary tract infection (CAUTI), 6.3 versus 3.3 per 1000 catheter-days, respectively. Most strikingly, the frequencies of resistance of Staphylococcus aureus isolates to methicillin (MRSA) (84.1% vs 56.8%, respectively), Klebsiella pneumoniae to ceftazidime or ceftriaxone (76.1% vs 27.1%, respectively), Acinetobacter baumannii to imipenem (46.3% vs 29.2%, respectively), and Pseudomonas aeruginosa to piperacillin (78.0% vs 20.2%, respectively) were also far higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 23.6% (CVC-associated bloodstream infections) to 29.3% (VAP).


Assuntos
Infecções Bacterianas/epidemiologia , Infecção Hospitalar/epidemiologia , Unidades de Terapia Intensiva , Adulto , África/epidemiologia , Ásia/epidemiologia , Farmacorresistência Bacteriana , Europa (Continente)/epidemiologia , Humanos , Incidência , Lactente , Recém-Nascido , América Latina/epidemiologia , Estados Unidos/epidemiologia , Adulto Jovem