Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39000840

RESUMO

This study introduces an innovative approach to the layered model, emphasizing the physical-chemical characterization of miscible liquid systems through ultrasonic techniques, with a specific focus on the water-ethanol system used in pharmaceutical formulations. Traditional characterization methods, while effective, face challenges due to the complex nature of solutions, such as the need for large pressure variations and strict temperature control. The proposed approach integrates partial molar volumes and partial propagation velocity functions into the layered model, enabling a nuanced understanding of miscibility and interactions. Ultrasonic techniques are used to calculate the isentropic compressibility coefficient for each component of the mixture as well as the total value using an additive mixing rule. Unlike conventional methods, this technique uses tabulated and experimental data to estimate the propagation velocity in the mixture, leading to a more precise computation of the isentropic compressibility coefficient. The results indicate a significant improvement in predicting the behavior of the water-ethanol system compared to the classical layered model. The methodology demonstrates the potential to provide new physicochemical insights that can be applied to other miscible systems beyond water-ethanol. This research has implications for improving the efficiency and accuracy of liquid medication formulations in the pharmaceutical industry.

2.
Ultrasonics ; 142: 107387, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38971005

RESUMO

The ultrasonic pulse-echo technique is widely employed to measure the wall thickness reduction due to corrosion in pipelines. Ultrasonic monitoring is noninvasive and can be performed online to evaluate the structural health of pipelines. Although ultrasound is a robust technique, it presents two main difficulties arising from the temperature variation in the medium being monitored: the mechanical assembly must have high stability and the ultrasonic propagation velocity must take into account the temperature variation. In this paper, a detailed strategy is presented to compensate for changes in the propagation velocity whenever the temperature changes. The method is considered self-compensated because the calibration data is obtained from the ultrasonic signals captured using the pipe under evaluation. The analysis of systematic errors in the temperature compensation is presented, first considering that a reference initial pipe thickness is given, and second when a reference sound velocity is given. The technique was evaluated under laboratory conditions using a closed loop with accelerated corrosion through the use of continuous flow saline water containing sand. In this test, the ultrasonic results were compared with the traditional coupon method used to determine corrosion loss. The results show that the self-compensated method was able to compensate for temperature fluctuations, and the total thickness loss measured by the ultrasound technique was close to the value measured by the coupons. Finally, the measurement system was tested in a production pipeline exposed to sunlight. The results show that the self-compensated method can reduce the oscillations in the thickness loss readings, caused by temperature swings, but large temperature variations cannot be completely compensated for. This experiment also shows the effects of low mechanical stability, which caused completely invalid results.

3.
Machines ; 10(1): 1-15, 2022. ilus, graf
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1371294

RESUMO

ABSTRACT: In patients with severe heart disease, the implantation of a ventricular assist device (VAD) may be necessary, especially in patients with an indication for heart transplantation. For this, the Institute Dante Pazzanese of Cardiology (IDPC) has developed an implantable centrifugal blood pump that will be able to help a diseased human heart to maintain physiological blood flow and pressure. This device will be used as a totally or partially implantable VAD. Therefore, performance assurance and correct specification of the VAD are important factors in achieving a safe interaction between the device and the patient's behavior or condition. Even with reliable devices, some failures may occur if the pumping control does not keep up with changes in the patient's behavior or condition. If the VAD control system has no fault tolerance and no system dynamic adaptation that occurs according to changes in the patient's cardiovascular system, a number of limitations can be observed in the results and effectiveness of these devices, especially in patients with acute comorbidities. This work proposes the application of a mechatronic approach to this class of devices based on advanced control, instrumentation, and automation techniques to define a method to develop a hierarchical supervisory control system capable of dynamically, automatically, and safely VAD control. For this methodology, concepts based on Bayesian networks (BN) were used to diagnose the patient's cardiovascular system conditions, Petri nets (PN) to generate the VAD control algorithm, and safety instrumented systems to ensure the safety of the VAD system.


Assuntos
Materiais Biocompatíveis , Coração Auxiliar , Pressão Sanguínea , Tomada de Decisões Assistida por Computador
4.
Sensors (Basel) ; 21(15)2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34372323

RESUMO

This work shows the application of an ultrasonic multiple-scattering sensor for monitoring water-in-petroleum emulsions. The sensor consists of a commercial ultrasonic transducer with an array of cylindrical scatterers placed in the near field. The scatterers are thin metal bars arranged in rows in front of the transducer. The backscattering signals were analyzed by calculating the wave energy and by a cross-correlation between signal segments; they were also used to determine the propagation velocity in the emulsions. The tests performed used emulsions with water volume concentrations from 0% to 50%. The results showed that both the signal energy and propagation velocity strongly depended on the concentration of water in the emulsion. Therefore, the ultrasonic multiple-scattering sensor can be used for on-line and real-time monitoring of the water content in water-in-crude-oil emulsions.


Assuntos
Petróleo , Emulsões , Petróleo/análise , Ultrassom , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA