Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Materials (Basel) ; 17(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38612181

RESUMO

The use of titanium as a biomaterial for the treatment of dental implants has been successful and has become the most viable and common option. However, in the last three decades, new alternatives have emerged, such as polymers that could replace metallic materials. The aim of this research work is to demonstrate the structural effects caused by the fatigue phenomenon and the comparison with polymeric materials that may be biomechanically viable by reducing the stress shielding effect at the bone-implant interface. A numerical simulation was performed using the finite element method. Variables such as Young's modulus, Poisson's coefficient, density, yield strength, ultimate strength, and the S-N curve were included. Prior to the simulation, a representative digital model of both a dental implant and the bone was developed. A maximum load of 550 N was applied, and the analysis was considered linear, homogeneous, and isotropic. The results obtained allowed us to observe the mechanical behavior of the dental implant by means of displacements and von Mises forces. They also show the critical areas where the implant tends to fail due to fatigue. Finally, this type of non-destructive analysis proves to be versatile, avoids experimentation on people and/or animals, and reduces costs, and the iteration is unlimited in evaluating various structural parameters (geometry, materials, properties, etc.).

2.
Materials (Basel) ; 15(21)2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36363435

RESUMO

Dental implants have become an alternative to replace the teeth of people suffering from edentulous and meet the physiological and morphological characteristics (recovering 95% of the chewing function). The evolution and innovation of biomaterials for dental implants have had a trajectory that dates back to prehistory, where dental pieces were replaced by ivory or seashells, to the present day, where they are replaced by metallic materials such as titanium or ceramics such as zirconium or fiberglass. The numerical evaluation focuses on comparing the stress distribution and general displacement between different dental implants and a healthy tooth when applying a force of 850 N. For the analysis, a model of the anatomical structure was developed of a healthy tooth considering three essential parts of the tooth (enamel, dentin, and pulp). The tooth biomodel was established through computed tomography. Three dental implant models were considered by changing the geometry of the abutment. A structural simulation was carried out by applying the finite element method (FEM). In addition, the material considered for the analyses was zirconium oxide (ZrO2), which was compared against titanium alloy (Ti6Al4V). The analyses were considered with linear, isotropic, and homogeneous properties. The variables included in the biomodeling were the modulus of elasticity, Poisson's ratio, density, and elastic limit. The results obtained from the study indicated a significant difference in the biomechanical behavior of the von Mises forces and the displacement between the healthy tooth and the titanium and zirconium implant models. However, the difference between the titanium implant and the zirconium implant is minimal because one is more rigid, and the other is more tenacious.

3.
Materials (Basel) ; 14(11)2021 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-34070453

RESUMO

Biofuels represent an energy option to mitigate polluting gases. However, technical problems must be solved, one of them is to improve the combustion process. In this study, the geometry of a piston head for a diesel engine was redesigned. The objective was to improve the combustion process and reduce polluting emissions using biodiesel blends as the fuel. The methodology used was the mechanical engineering design process. A commercial piston (base piston) was selected as a reference model to assess the piston head's redesign. Changes were applied to the profile of the piston head based on previous research and a new model was obtained. Both models were evaluated and analyzed using the finite element method, where the most relevant physical conditions were temperature and pressure. Numerical simulations in the base piston and the new piston redesign proposal presented similar behaviors and results. However, with the proposed piston, it was possible to reduce the effort and the material. The proposed piston profile presents adequate results and behaviors. In future, we suggest continuing conducting simulations and experimental tests to assess its performance.

4.
Biomed Res Int ; 2021: 6688164, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33880378

RESUMO

The modelling of biological structures has allowed great advances in Engineering, Biology, and Medicine. In turn, these advances are seen from the design of footwear and sports accessories, to the design of prostheses, accessories and rehabilitation treatments. The reproduction of the various tissues has gone through an important evolution thanks to the development of computer systems and programs. However, knowledge of the medical-biological and engineering areas continues to be required, and it involves a considerable investment of time and resources. The resulting biomodels still require great precision. The present work shows a methodology that allows to optimize computational resources and reduce elaboration time of biomodels. Through this methodology, it is possible to generate a biomodel of high biofidelity of a human knee. This biomodel is constituted by hard tissues (cortical and trabecular bones) and soft tissues (ligaments and meniscus) resulting in the modelling of the lower third of the femur, the tibial plateaus, the anterior cruciate ligament, posterior cruciate ligament, external lateral ligament, interior lateral ligaments, and the meniscus. With this model and methodology, it is possible to perform numerical analyses that will provide results very similar to those of real life. As, the methodology allows to assign the mechanical properties to each tissue and the anatomical structure.


Assuntos
Imageamento Tridimensional , Joelho/diagnóstico por imagem , Impressão Tridimensional , Análise de Elementos Finitos , Humanos , Ligamentos/diagnóstico por imagem , Imageamento por Ressonância Magnética
5.
Comput Math Methods Med ; 2020: 4292501, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32454882

RESUMO

Experimental research on living beings faces several obstacles, which are more than ethical and moral issues. One of the proposed solutions to these situations is the computational modelling of anatomical structures. The present study shows a methodology for obtaining high-biofidelity biomodels, where a novel imagenological technique is used, which applies several CAM/CAD computer programs that allow a better precision for obtaining a biomodel, with highly accurate morphological specifications of the molar and tissues that shape the biomodel. The biomodel developed is the first lower molar subjected to a basic chewing simulation through the application of the finite element method, resulting in a viable model, able to be subjected to various simulations to analyse molar biomechanical characteristics, as well as pathological conditions to evaluate restorative materials and develop treatment plans. When research is focused in medical and dental investigation aspects, numerical analyses could allow the implementation of several tools commonly used by mechanical engineers to provide new answers to old problems in these areas. With this methodology, it is possible to perform high-fidelity models no matter the size of the anatomical structure, nor the complexity of its structure and internal tissues. So, it can be used in any area of medicine.


Assuntos
Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Imageamento Tridimensional/métodos , Modelos Dentários , Dente Molar/anatomia & histologia , Dente Molar/diagnóstico por imagem , Fenômenos Biomecânicos , Biologia Computacional , Simulação por Computador , Desenho Assistido por Computador , Humanos , Imageamento Tridimensional/estatística & dados numéricos , Modelos Biológicos , Dente Molar/fisiologia , Software
6.
Appl Bionics Biomech ; 2018: 4196343, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29849758

RESUMO

The aim of the present work is to identify the reactions of the dental organs to the different forces that occur during chewing and the transcendence of the union and contact maintained by the dental tissues. The study used a lower first molar biomodel with a real morphology and morphometry and consisting of the three dental tissues (enamel, dentin, and pulp) each with its mechanical properties. In it, two simulations were carried out, as would the process of chewing a food. One of the simulations considers the contact between the enamel and the dentin, and the other does not take it into account. The results obtained differ significantly between the simulations that consider contact and those that do not, establishing the importance of taking this contact into account. In this way, the theories that establish horizontal and lateral occlusion forces are present during the functional chewing process which are viable to be correct. The case studies carried out present not only the reasons for the failure of enamel but also the failure of the restoration materials used. This reflection will allow the development of more adequate materials, mechanical design of prostheses, implants, and treatment.

7.
Micromachines (Basel) ; 8(11)2017 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-30400510

RESUMO

A strong influence of mechanical action in nonlinear optical transmittance experiments with bimetallic nanoparticles integrated by gold and platinum was observed. The nanostructured samples were synthesized by a sol-gel method and contained in an ethanol suspension. UV-VIS spectroscopy evaluations, Transmission electron microscopy studies and input-output laser experiments were characterized. A two-photon absorption effect was induced by nanosecond pulses at 532 nm wavelength with an important contribution from the plasmonic response of the nanomaterials. All-optical identification of acoustical waves was remarkably improved by optical nonlinearities. High sensitivity for instrumentation of mechano-optical signals sensing particular fluids was demonstrated by using a variable carbon dioxide incorporation to the system.

8.
Rev. colomb. biotecnol ; 17(1): 79-90, ene.-jun. 2015. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-751192

RESUMO

El ritmo de vida actual, tanto sociocultural como tecnológico, ha desembocado en un aumento de enfermedades y padecimientos que afectan las capacidades físico-motrices de los individuos. Esto ha originado el desarrollo de prototipos para auxiliar al paciente a recuperar la movilidad y la fortaleza de las extremidades superiores afectadas. El presente trabajo aborda el diseño de una estructura mecánica de un exoesqueleto con 4 grados de libertad para miembro superior. La cual tiene como principales atributos la capacidad de ajustarse a la antropometría del paciente mexicano (longitud del brazo, extensión del antebrazo, condiciones geométricas de la espalda y altura del paciente). Se aplicó el método BLITZ QFD para obtener el diseño conceptual óptimo y establecer adecuadamente las condiciones de carga de servicio. Por lo que, se definieron 5 casos de estudio cuasi-estáticos e implantaron condiciones para rehabilitación de los pacientes. Asimismo, mediante el Método de Elemento Finito (MEF) se analizaron los esfuerzos y deformaciones a los que la estructura está sometida durante la aplicación de los agentes externos de servicio. Los resultados presentados en éste trabajo exhiben una nueva propuesta para la rehabilitación de pacientes con problemas de movilidad en miembro superior. Donde el equipo propuesto permite la rehabilitación del miembro superior apoyado en 4 grados de libertad (tres grados de libertad en el hombro y uno en el codo), el cual es adecuado para realizar terapias activas y pasivas. Asimismo, es un dispositivo que está al alcance de un mayor porcentaje de la población por su bajo costo y fácil desarrollo en la fabricación.


The pace of modern life, both socio-cultural and technologically, has led to an increase of diseases and conditions that affect the physical-motor capabilities of persons. This increase has originated the development of prototypes to help patients to regain mobility and strength of the affected upper limb. This work, deals with the mechanical structure design of an exoskeleton with 4 degrees freedom for upper limb. Which has the capacity to adjust to the Mexican patient anthropometry (arm length, forearm extension, geometry conditions of the back and the patient's height) BLITZ QFD method was applied to establish the conceptual design and loading service conditions on the structure. So, 5 quasi-static cases of study were defined and conditions for patient rehabilitation were subjected. Also by applying the finite element method the structure was analyzed due to service loading. The results presented in this work, show a new method for patient rehabilitation with mobility deficiencies in the upper limb. The proposed new design allows the rehabilitation of the upper limb under 4 degrees of freedom (tree degrees of freedom at shoulder and one at the elbow), which is perfect to perform active and passive therapy. Additionally, it is an equipment of low cost, which can be affordable to almost all the country population.

9.
Rev. colomb. biotecnol ; 15(1): 28-41, ene.-jun. 2013. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-696142

RESUMO

El desgaste de los insertos de Polietileno de Ultra-Alto Peso Molecular (UHMWPE pos sus siglas en inglés) continúa afectando la longevidad de las prótesis totales de rodilla (PTR) junto con el aflojamiento aséptico, y ambos constituyen las dos principales causas de falla de las prótesis. Considerando esto, es necesario encontrar soluciones adecuadas para evitar el desgaste excesivo y hasta la ruptura de los insertos de polietileno. En este trabajo se realizó el estudio mediante simulación numérica de una PTR Scorpio II® Stryker®, la cual se retiró por desgaste del inserto de UHMWPE en el Hospital 1° de Octubre del ISSSTE en México. Se utilizaron las hipótesis de Bartel et al. (1995) y Chillag et al. (1991) para la validación del método numérico utilizado, las cuales establecen que el desgaste del polietileno puede reducirse utilizando insertos tibiales de mayor espesor, lo cual disminuye las presiones de contacto. Los análisis se realizaron mediante MEF variando el espesor del inserto de 6, 8, 10, 12 y 14 mm, suponiendo cargas axiales de tipo cuasi-estático en la articulación a cero grados de flexión, para 1.33 veces el peso de un individuo de 75 kg (736 N) empleando el ciclo normalizado de marcha. Los resultados obtenidos muestran similitud con los reportados por Bei et al. (2004) y Deen et al. (2006). Después de validar el método, se desarrolló el modelo de MEF de la PTR y se determinaron las curvas de esfuerzo y de áreas de contacto del inserto de UHMWPE, con lo que se obtuvo información importante para modificar el diseño y obtener una prótesis de geometría conforme en los planos coronal y sagital del inserto femoral y el inserto de polietileno, de acuerdo con el fenotipo mexicano.


Wear of UHMWPE inserts continues affecting the longevity of total knee replacements (TKR) together with septic loosening, and both constitute two main causes of prosthesis failure. It is necessary to find appropriate solutions to avoid excessive wear and failure of polyethylene inserts. In this work a study was carried out by means of numeric simulation of a Scorpio II® Stryker® TKR, which was retired due to wear of UHMWPE in the Hospital 1° de Octubre of ISSSTE in Mexico city. Hypotheses of Bartel et al. (1995) and Chillag et al. (1991) were used, which settle down that wear of polyethylene can decrease using thicker tibial inserts, which can be reduced contact pressures. Analyses of this work was carried out by means of FEM varying insert thickness of 6, 8, 10, 12 and 14 mm, considered quasi-static axial loads actuating on the articulation with zero degrees of flexion and loads equivalent to 1.33 times of bodyweight of a subject of 75 kg (736 N) was considered. Normalized gait cycle was employed and results obtained are similar to those reported by Bei et al. (2004) and Deen et al. (2006). After validating the method, a model of study case of TKR in FEM was developed and the curves of stress and contact areas of UHMWPE were determined, with which important information was obtained to modify the design, as well as to obtain a prosthesis of optimal conformity in both coronal and sagital planes of the femoral and UHMWPE inserts, in agreement with characteristics of the Mexican phenotype.


Assuntos
Humanos , Joelho , Análise Numérica Assistida por Computador , Próteses e Implantes , Polietileno , Pressão
10.
Rev. colomb. biotecnol ; 12(2): 41-54, dic. 2010. ilus
Artigo em Espanhol | LILACS | ID: lil-590773

RESUMO

En México, la mortalidad debido a enfermedades bronco-respiratorias se ubica en el sexto lugar según datos estadísticos dados por el Instituto Nacional de Enfermedades Respiratorias (INER). Esto genera la necesidad de incrementar la eficiencia en la aplicación de los tratamientos usados para este tipo de patología. Algunos de los métodos utilizados con mayor frecuencia para el tratamiento de estas dolencias hacen uso de micro dispositivos, también conocidos como válvulas endobronquiales. Este es un sistema alternativo que evita cirugías invasivas y logra prolongar e incrementar la calidad de vida de los pacientes. En este trabajo se presenta el análisis del desempeño de la válvula IBV®. Para el desarrollo del estudio numérico se determinaron las dimensiones y propiedades mecánicas del modelo a partir de catálogos del fabricante. Se desarrolló un modelo para el cual se consideraron las propiedades del Nitinol® y Silastic®. Asimismo, se propusieron dos condiciones de operación para la válvula, una anclada en el bronquio y la otra en la condición en la que se encuentra plegada dentro del broncoscopio. Se utilizó el Método del elemento finito (MEF) para simular las condiciones de trabajo de la válvula. Los resultados encontrados muestran el funcionamiento estructural y el nivel de los esfuerzos generados en el implante durante el ciclo de respiración forzada del individuo. Además, se proporcionan las bases para generar un nuevo dispositivo que pueda emular el funcionamiento de este tipo de implantes y aumente la eficiencia del tratamiento de dicha patología.


In Mexico, the mortality rate due to bronchial respiratory sickness is placed in the sixth position, according to statistics from the National Institute of Breathing Sickness (INER), so it is convenient to increment the efficiency of treatments for those pathologies. The intrabronchial valve is a recommended alternative method; being it main objective to avoid invasive surgery and increase the time and quality of patient´s life. Within this work a biomechanical analysis of an IBV® valve is carried out. Regarding the numerical analysis, the dimensions and mechanical properties of the valve were proposed based on catalogues published by the manufacturer as more reliable information was not available in the open literature. As a result, a new model was developed in which both materials Nitinol® and Silastic® are considered as the main valve materials. The proposed working conditions assume that the valve is implanted in folded form at the bronchus and then anchored when it is unfolded. Finite Element Method (FEM) was used to simulate the proposed working conditions. Results obtained show the structural performance and the level of stress generated in the implant during the breathing cycle. In addition, it provides the knowledge to generate a new device that could emulate the performance of these implants and develop a more efficient treatment this disease.


Assuntos
Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/enfermagem , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/induzido quimicamente , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/química , Neoplasias Pulmonares/tratamento farmacológico , Valvas Cardíacas/anormalidades , Valvas Cardíacas/fisiologia , Valvas Cardíacas/imunologia , Valvas Cardíacas/patologia , Valvas Cardíacas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA