Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Dentomaxillofac Radiol ; 45(2): 20150332, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26648387

RESUMO

OBJECTIVES: This study aimed to evaluate the accuracy of three different methods for assessing the volume of cleft defects in CBCT images. The influence of field of view (FOV) and voxel sizes was also assessed. METHODS: Using three radio-opaque plastic skulls, unilateral defects were created to mimic alveolar clefts and were filled with wax following the contralateral side contours. They were scanned in a CBCT unit using four different acquisition protocols, varying FOV and voxel sizes. Using three different methods, the defect/wax volume was evaluated on the images by defining: (1) the width, height and facial-palatal length of the defect in maximum intensity projection; (2) the areas of the defect on axial slices; and (3) the threshold and segmentation of the region of interest. The values obtained from each method using different acquisition protocols were compared with the real volume of the wax (gold standard) using ANOVA and Tukey's test. RESULTS: Methods 2 and 3 did not differ from the gold standard (p > 0.05). Conversely, Method 1 presented statistically significant overestimated values (p < 0.01). No differences were found among the different FOV and voxel sizes (p > 0.05). CONCLUSIONS: CBCT volumes proved reliable for the volumetric assessment of alveolar cleft defects, when using Methods 2 and 3 regardless of FOV and voxel sizes. It may be possible to improve surgical planning and outcomes by knowing the exact volume of grafting material needed prior to the surgical intervention.


Assuntos
Processo Alveolar/anormalidades , Fissura Palatina/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Processo Alveolar/diagnóstico por imagem , Pontos de Referência Anatômicos/diagnóstico por imagem , Cefalometria/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento Tridimensional/estatística & dados numéricos , Modelos Anatômicos , Palato/diagnóstico por imagem , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA