Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 66(3): 353-61, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17855099

RESUMO

The traceability of activity measurements performed during the development phase of the radiopharmaceutical and in its clinical application is essential for establishing the comparability of clinical results reported in the nuclear medicine field. This paper presents and discusses the evaluation over time of the quality of activity measurement results obtained in Cuban nuclear medicine, on the basis of statistical samples taken during the radionuclide calibrator comparison program. An attempt is also made to evaluate the role played by such comparisons in quality measurement improvement in nuclear medicine, on the basis of results obtained in a number of countries and published by several authors over a period of time. Specifically, improvements of the measurement performance over time assessed by such exercises were found dissimilar in magnitudes for different countries. Two phases could be distinguished in the improvement process over time. Firstly, a fast improvement can be obtained resulting from the improvement in measurement accuracy of devices. After that, the achievement of new and sustained improvements goes slowly and requires an application of quality assurance programs where the qualification upgrading of personnel become an essential point.


Assuntos
Medicina Nuclear/normas , Radioisótopos/normas , Compostos Radiofarmacêuticos/normas , Calibragem , Humanos , Reprodutibilidade dos Testes
2.
Appl Radiat Isot ; 64(4): 475-84, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16303312

RESUMO

This paper describes the results obtained using a simulated test for administration of activity in nuclear medicine between 2002 and 2004. Measurements in the radionuclide calibrator are made during the different stages of the procedure. The test attempts to obtain supplementary information on the quality of the measurement, with the aim of evaluating in a more complete way the accuracy of the administered activity value compared with the prescribed one. The participants' performance has been assessed by means of a statistical analysis of the reported data. Dependences between several attributes of the simulated administration tests results are discussed. Specifically, the proportion of satisfactory results in the 2003-2004 period was found to be higher than in 2002. It reveals an improvement of the activity administration in the Cuban nuclear medicine departments since 2003.


Assuntos
Medicina Nuclear , Calibragem , Meia-Vida , Medicina Nuclear/instrumentação , Radioisótopos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA