Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Oral Investig ; 27(1): 377-385, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36220953

RESUMO

OBJECTIVE: Assess the prevalence of self-reported TMD symptoms and anxiety and check the quality of sleep and life during the distance learning period in university students at the University of Brasilia (UnB). MATERIALS AND METHODS: The participants were students from the Health Sciences College and Medicine College at UnB. Self-administered questionnaires were used to evaluate symptoms of TMD, quality of life, and sleep quality. One-way analysis of variance, followed by Bonferroni test, and Kruskal-Wallis test, followed by Dunn's test, were performed (P < 0.05). For qualitative data analysis, the chi-square test was applied (P < 0.05). RESULTS: Total 156 students were included; prevalence of TMD, anxiety, sleep disturbance, and poor sleep quality was 73.1%, 84%, 12.8%, and 62.8%, respectively. A greater prevalence of painful TMD was observed in students with severe anxiety (P = 0.007). Students with symptoms of painful TMD, severe anxiety, and sleep disorders had statistically worse quality of life. CONCLUSIONS: The implementation of distance learning in health courses to replace classroom teaching during the COVID-19 pandemic has impacted TMD prevalence, anxiety, quality of life, and sleep quality. CLINICAL RELEVANCE: Psychological factors are directly associated with TMD symptoms and quality of life, TMD conditions are related to quality of life as well. COVID-19 pandemic and the distance learning in health courses are new situations that can lead to a great impact on mental health and in consequence to TMD conditions and quality of life.


Assuntos
COVID-19 , Educação a Distância , Transtornos da Articulação Temporomandibular , Humanos , Autorrelato , Prevalência , Qualidade de Vida , Pandemias , COVID-19/complicações , COVID-19/epidemiologia , Transtornos da Articulação Temporomandibular/complicações , Inquéritos e Questionários , Dor
2.
Prosthet Orthot Int ; 46(3): 299-304, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35019887

RESUMO

OBJECTIVE: This study reports a clinical case of rehabilitation of a patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound. The finger prosthesis was custom- made using a silicone. CASE DESCRIPTION: This study presents a clinical case of a female patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound in 2016. The patient was attended at a reference center in maxillofacial rehabilitation in the city of Brasilia, Distrito Federal, Brazil, for the manufacture of a finger prosthesis. After molding, a finger waxing was obtained using the right little finger as a template. The waxing was later adjusted on the plaster model of the affected stump. The prosthesis was manufactured with silicone and intrinsically stained with a makeup powder. A water-based adhesive and a ring were used to generate a slight compression so that the prosthesis was retained on the stump. OUTCOMES: The rehabilitation showed satisfactory levels of stability, retention, and aesthetics, and it was usable and clinically acceptable, as observed in a follow-up appointment in February 2020. CONCLUSIONS: The complete or partial reestablishment of functions performed by important structures, such as the fingers, is essential to increase the quality of life of individuals, improving their performance of daily activities. In addition, reporting on this public health problem allows scientific advancement in the area.


Assuntos
Traumatismos dos Dedos , Armas de Fogo , Ferimentos por Arma de Fogo , Desarticulação , Feminino , Traumatismos dos Dedos/reabilitação , Traumatismos dos Dedos/cirurgia , Humanos , Desenho de Prótese , Qualidade de Vida , Silicones , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/cirurgia
3.
J Clin Exp Dent ; 11(9): e807-e813, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31636873

RESUMO

BACKGROUND: The aim of this study was to evaluate the distribution of stress in complete fixed mandibular prostheses with infrastructures (IE) fabricated with different materials and techniques, under compressive force. MATERIAL AND METHODS: A model of an edentulous mandible, which received five 4x11 mm external hexagon implants between the mental foramens, was fabricated. The groups were divided into: Group I - IE in nickel-chromium with an acrylic resin occlusal coating; Group II - IE in nickel-chromium with a ceramic occlusal coating; Group III - IE milled in zirconia with a ceramic coating. For the photoelastic methodology, 70 N axial loads were applied in three regions. Photographic images were taken and analyzed according to the number of high-intensity fringes. For the strain gauge methodology, the measurement of stresses was performed in two distinct regions. The same compression tests described earlier were then performed. The registered stress values were grouped in tables and submitted to two-factor variance analysis (ANOVA) and the Tukey test with 5% significance. RESULTS: The results of the two methodologies demonstrated smaller stress values for Group I, when compared to the other groups. CONCLUSIONS: It was possible to conclude that the complete fixed prostheses, with infrastructures cast in metal and acrylic occlusal coating, demonstrated better biomechanical results. Key words:Dental implants, mandibular prosthesis implantation, biomechanics.

4.
J Prosthodont ; 28(6): 692-700, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31125155

RESUMO

PURPOSE: To investigate the influence of nonthermal plasma (NTP) treatment on the tensile bond strength between heat-polymerized acrylic resin for ocular prostheses and silicone reliner, with and without the use of an adhesive primer. MATERIALS AND METHODS: One-hundred and sixty-four acrylic resin specimens were fabricated and randomly distributed into four groups according to the type of surface treatment: Sofreliner Primer, NTP, Sofreliner Primer + NTP, and NTP + Sofreliner Primer. Two specimens interposed with relining material (Sofreliner) formed one test sample to perform the tensile bond strength tests, before (initial) and after storage (final) in saline solution (37°C, 90 days, n = 10). Surface characterization was performed by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The failure type was classified as cohesive, adhesive, or mixed. The data were analyzed statistically using the two-way ANOVA and Tukey test, as well as the chi-squared test (α = 0.05), Bonferroni correction (α = 0.005), and Spearman correlation coefficient (α = 0.05). RESULTS: The SEM and EDS analyses showed the presence of a thin, homogenous organic film in the groups treated with NTP. The NTP + Sofreliner Primer group presented the largest bond strength mean values in the initial period (p < 0.05). Sofreliner Primer and NTP + Sofreliner Primer groups presented the first and second largest tensile bond strength mean values in the final period (p < 0.05), respectively. NTP + Sofreliner Primer group also had the largest number of cohesive (70%, initial) and mixed (90%, final) failures. CONCLUSIONS: The NTP treatment performed before the primer application enhanced the bond between the acrylic resin ocular prosthesis and the Sofreliner silicone-based reliner, even after 90 days of immersion in saline solution.


Assuntos
Colagem Dentária , Silicones , Resinas Acrílicas , Cimentos Dentários , Análise do Estresse Dentário , Olho Artificial , Teste de Materiais , Propriedades de Superfície , Resistência à Tração
5.
BMC Oral Health ; 19(1): 75, 2019 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-31053131

RESUMO

BACKGROUND: The aim was to analyze the levels of stress of edentulous patients through the state-trait anxiety inventory (STAI) and salivary flow through the visual analogue scale (VAS) xerostomia questionnaire, as well as analyze the levels of cortisol, capillary blood glucose, and blood pressure (BP) before and after the installation of complete dentures. METHODS: Fifty patients were evaluated. The STAI and VAS xerostomia questionnaire were applied before the installation of the prosthesis, on the day of its installation, and 1 month after the last recall visit. The BP measurement, as well as salivary and blood collections, were performed before the installation of the prothesis, and 1 month after the last recall visit. Data from the VAS xerostomia questionnaire and cortisol levels were submitted to ANOVA and the Tukey test (P = .05). Data from the STAI, as well as blood glucose and BP levels, were submitted to the Chi-square test (P = .05). The correlation between cortisol and blood glucose and between cortisol levels and BP was analyzed. RESULTS: There was no statistically significant association between the questions of the VAS xerostomia questionnaire, STAI-state and STAI-trait scores, or the periods analyzed. However, the cortisol level collected in the morning decreased after the installation of the prosthesis. There was a correlation between cortisol and blood glucose and BP levels. CONCLUSIONS: The installation of complete dentures was beneficial for patients since it was probably responsible for the cortisol level reduction.


Assuntos
Ansiedade/metabolismo , Glicemia/metabolismo , Pressão Sanguínea/fisiologia , Prótese Total/psicologia , Hidrocortisona/metabolismo , Estresse Psicológico/diagnóstico , Estresse Psicológico/psicologia , Ansiedade/psicologia , Humanos
6.
J Med Eng Technol ; 42(5): 359-367, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30251571

RESUMO

In some clinical situations, the clinician may encounter previously installed implants that should be associated with other implants for a proper rehabilitation. The aim of this study was to evaluate the biomechanical behaviour of a multiple prosthesis joined by different implant connections using photoelasticity. Photoelastic models with a screwed fixed prosthesis supported by implants with different connection systems (Morse taper, external hexagon, internal hexagon, and Flexcone), and different combinations among them, were fabricated. Each assembly was placed in a circular polariscope, and axial and oblique (45°) loads of 100 N were applied on the occlusal surface of the crowns. The fringe patterns were photographed and the analysis was performed by counting the number of high-intensity fringes and also according to the stress distribution region where they appeared. Among implants of the same connection, the external connections obtained a greater number of high intensity fringes when compared to the internal connections. From the biomechanical point of view, the association between different types of connections obtained positive results.


Assuntos
Próteses e Implantes , Fenômenos Biomecânicos , Estresse Mecânico
7.
J Med Eng Technol ; 41(4): 309-313, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28351185

RESUMO

New systems are released in the odontological market with the objective of bringing improvements and advancements in the clinical success of implants and implant-supported prostheses. The distribution of tension for the bone/implant system of these new systems is important. The purpose of this work was to evaluate, by photoelastic analysis and strain gauges, the distribution of tension for the bone/implant system, using the Slim system. A photoelastic cast with an external hexagon implant was manufactured and a metal prosthesis was screwed below it, with or without the tested system. For the photoelasticity methodology, a photoelastic cast, with or without the tested system, was positioned in a circular polariscope, and axial loads of 100 N were applied to the centre of the crown. The pattern of tension generated was photographed and analysed qualitatively in an imaging programme. For the extensometry methodology, two extensometers were placed in the mesial and distal region of the implant in the photoelastic cast. The axial loads were applied to the group again, with or without the system (n = 10). The t test of independent samples with a significance level of 5% was used for this analysis. This study demonstrated greater tension values for both the photoelastic and extensometry methods when the tested system was used. Clinical studies must be performed to evaluate the tested system because the results might not be clinically significant to a bone reabsorption.


Assuntos
Implantes Dentários , Fenômenos Biomecânicos , Humanos , Teste de Materiais , Estresse Mecânico
8.
Implant Dent ; 26(1): 106-111, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28060024

RESUMO

PURPOSE: The aim of this study was to assess stress distribution in the bone-implant interface of a mandibular implant-supported prosthesis with different cantilever lengths, aesthetic coating materials, and implant abutments. MATERIALS AND METHODS: A photoelastic model of an edentulous mandible, containing 5 external hexagon implants, was constructed. Experimental models were divided into 6 groups: group 1-UCLA component and metal bar; group 2-UCLA component and acrylic resin coating; group 3-UCLA component and porcelain coating; group 4-abutment and metal bar; group 5-abutment and acrylic resin coating; and group 6-abutment and porcelain coating. Forces were applied to the most anterior implant, the most posterior implant, and different cantilever lengths. RESULTS: The results showed a higher number of high-stress fringes as the cantilever length increased. Fringes were better distributed in groups with prostheses composed of acrylic resin and in groups that contained an abutment. CONCLUSION: The stress distribution in the bone-implant interface is improved when the cantilever is eliminated and when abutments in an acrylic resin prosthesis are used.


Assuntos
Prótese Dentária Fixada por Implante/métodos , Prótese Total , Interface Osso-Implante/fisiopatologia , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante/normas , Análise do Estresse Dentário , Prótese Total/normas , Humanos , Técnicas In Vitro , Resinas Sintéticas/uso terapêutico , Suporte de Carga
9.
J Med Eng Technol ; 41(2): 115-121, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27696920

RESUMO

Short dental implants have been used as an attempt to avoid bone grafts surgery, however there are few literature reports that evaluate changes to their design. Therefore, the aim of this study was to assess the effect of different short implant design on stress distribution through photoelastic analysis. Six external hexagon (5 × 5 mm) short dental implants with different design were used. Each group was treated with a single crown and a three element fixed partial dental prosthesis, resulting in a total of 12 photoelastic models. The assembling photoelastic model-implant-prosthesis was set in a circular polariscope where loads of 100N were applied on the occlusal surface with a Universal Test Machine (UTM). The tension fringes were photographed and later assessed qualitatively by a graphic software (Adobe Photoshop). Less high-intensity fringes were observed on the short implants with triangular threads, short external hexagon and flat apical profile. In conclusion, the macrodesign influenced the amount of stress distributed to the bone when short dental implants are placed.


Assuntos
Implantes Dentários , Prótese Parcial Fixa , Estresse Mecânico , Fenômenos Biomecânicos , Humanos , Teste de Materiais , Desenho de Prótese
10.
Toxicol In Vitro ; 36: 180-185, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27521695

RESUMO

The aim of this study was to evaluate the influence of pigment incorporation on the cytotoxicity of ocular prosthesis N1 color acrylic resin. Nine samples were manufactured by heat-polymerization in water bath and divided into 3 groups: acrylic resin without pigment incorporation (group R), acrylic resin with pigment incorporation (group RP), and acrylic pigment (group P). Eluates formed after 72h of sample immersion in medium were incubated with conjunctival cell line (Chang conjunctival cells) for 72h. The negative control group consisted in medium without samples (group C). The cytotoxic effect from the eluates was evaluated using MTT assay (cell proliferation), ELISA assay (quantification of IL1ß, IL6, TNF α and CCL3/MIP1α) and RT-PCR assay (mRNA expression of COL IV, TGF ß and MMP9). Data were submitted to ANOVA with Bonferroni post-tests (p<0.05). All groups were considered non-cytotoxic based on cell proliferation. However, resin with pigment incorporation showed significant IL6 quantity increase. Resin without pigment incorporation exhibited higher mRNA expression of COL IV, MMP9 and TGF ß, however it was also observed for the negative control group. The materials exhibited divergent biological behavior. Despite the pigment incorporation that resulted in an increase of IL6, no cytotoxicity was observed based on cell proliferation.


Assuntos
Resinas Acrílicas/toxicidade , Corantes/toxicidade , Túnica Conjuntiva/citologia , Olho Artificial , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Colágeno Tipo IV/genética , Humanos , Metaloproteinase 9 da Matriz/genética , RNA Mensageiro/metabolismo , Fator de Crescimento Transformador beta/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA