Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Vasc Access ; : 11297298221127756, 2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36203380

RESUMO

BACKGROUND: Catheter implantation techniques for peritoneal dialysis (PD) have advanced significantly in recent years. We aimed to analyze the survival and associated complications of catheters inserted using a new technique that is guided by ultrasound and fluoroscopy and requires minimal tissue dissection. The procedure was performed by nephrologists in the outpatient basis, we compared these results of the minimally invasive insertion with traditional implantation using trocars. METHODS: A total of 152 PD catheters were placed in 152 patients with stage 5 chronic kidney disease; 62.5% of the patients were men, with a mean age of 56.6 ± 18.5 years. The following two methods were used: minimally invasive insertion (MI group, n = 73) and trocar insertion (T group, n = 79). Patients in both the groups were followed prospectively for 26 months from the date of the first implantation. RESULTS: Gender, age, and prevalence of diabetes mellitus were not significantly different between the groups, while the body mass index, presence of obesity, and abdominal scars from previous surgeries were higher in the MI group (p = 0.021). The incidence of catheter dysfunction was lower in the MI group compared to group T (6.8% vs 20.3%; p = 0.019). Exit site infection was also lower with the new technique (4.1% vs. 18.9%; p = 0.005). Further, the cumulative incidence of peritonitis also reduced with MI (p = 0.034). Finally, the overall catheter survival at 1 year was 89%, which has been shown as higher in group MI (95% vs 82% in group T; p = 0.025). CONCLUSION: The MI technique for catheter insertion showed low complication rates and excellent catheter survival as compared to traditional implantation methods; thus, it may be an alternative method for PD catheter placement.

2.
Int Urol Nephrol ; 54(1): 193-199, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34132971

RESUMO

PURPOSE: Hemodialysis patients with COVID-19 are at increased risk of death. We aimed to describe the characteristics of a cohort of Brazilian hemodialysis patients with COVID-19 and assess their mortality rate and risk factors for death. METHODS: Retrospective cohort study of 741 Brazilian hemodialysis patients with confirmed COVID-19 from Feb-Dec/2020, of 52 dialysis centers of the country. We analyzed comorbid conditions, sociodemographic factors, and dialysis-related parameters. To detect risk factors for mortality in hemodialysis patients, we performed multivariable Cox proportional hazard regression analysis. Survival was analyzed by Kaplan-Meier. RESULTS: From 9877 hemodialysis patients, 741 were diagnosed with COVID-19. Mean age was 57 ± 16 years, 61% were male, and 51% white. The most frequent symptoms were fever (54.1%), cough (50.9%), and dyspnea (37.2%); 14.2% were asymptomatic. There were 139 deaths (18.8%), with 66% within the disease's first 15 days. 333 patients (44.9%) required hospitalization, and 211 (28.5%) were admitted to an intensive care unit. The cumulative probability of survival at 90 days of diagnosis was 79% (95% CI 76-82%). In the fully adjusted multivariate model, the risk factors significantly associated with death were diabetes mellitus (HR 1.52, 95% CI 1.05-2.19, P = 0.026), use of a central venous catheter (CVC) (HR 1.79, 95% CI 1.22-2.64, P = 0.003), age (HR 1.03, 95% CI 1.01-1.04, P < 0.001), and origin from the North vs. Southeast region (HR 2.60, 95% CI 1.01-6.68, P = 0.047). CONCLUSIONS: Hemodialysis patients using a CVC as the vascular access, aside from diabetic and elderly ones, should be closely monitored due to their high risk of death in the course of the COVID-19.


Assuntos
COVID-19/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Cateteres Venosos Centrais/efeitos adversos , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Brasil/epidemiologia , Infecções Relacionadas a Cateter/epidemiologia , Comorbidade , Feminino , Seguimentos , Humanos , Incidência , Falência Renal Crônica/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2 , Taxa de Sobrevida/tendências , Fatores de Tempo
3.
PLoS One ; 15(10): e0239770, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33052974

RESUMO

Microcirculatory disorders have been consistently linked to the pathophysiology of sepsis. One of the major organs affected is the kidneys, resulting in sepsis-associated acute kidney injury (SA-AKI) that correlates considerably with mortality. However, the potential role of clinical assessment of peripheral perfusion as a possible tool for SA-AKI management has not been established. To address this gap, the purpose of this study was to investigate the prevalence of peripheral hypoperfusion in SA-AKI, its association with mortality, and fluid balance. This observational cohort study enrolled consecutive septic patients in the Intensive Care Unit. After fluid resuscitation, peripheral perfusion was evaluated using the capillary filling time (CRT) and peripheral perfusion index (PI) techniques. The AKI was defined based on both serum creatinine and urine output criteria. One hundred and forty-one patients were included, 28 (19%) in the non-SA-AKI group, and 113 (81%) in the SA-AKI group. The study revealed higher peripheral hypoperfusion rates in the SA-AKI group using the CRT (OR 3.6; 95% CI 1.35-9.55; p < 0.05). However, this result lost significance after multivariate adjustment. Perfusion abnormalities in the SA-AKI group diagnosed by both CRT (RR 1.96; 95% CI 1.25-3.08) and PI (RR 1.98; 95% CI 1.37-2.86) methods were associated to higher rates of 28-day mortality (p < 0.01). The PI's temporal analysis showed a high predictive value for death over the first 72 h (p < 0.01). A weak correlation between PI values and the fluid balance was found over the first 24 h (r = - 0.20; p < 0.05). In conclusion, peripheral perfusion was not different intrinsically between patients with or without SA-AKI. The presence of peripheral hypoperfusion in the SA-AKI group has appeared to be a prognostic marker for mortality. This evaluation maintained its predictive value over the first 72 hours. The fluid balance possibly negatively influences peripheral perfusion in the SA-AKI.


Assuntos
Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/fisiopatologia , Microcirculação/fisiologia , Sepse/fisiopatologia , Injúria Renal Aguda/sangue , Estudos de Coortes , Creatinina/sangue , Feminino , Hidratação/métodos , Humanos , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Perfusão/métodos , Prognóstico , Sepse/sangue , Sepse/mortalidade , Equilíbrio Hidroeletrolítico/fisiologia
5.
Semin Dial ; 27(3): E32-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24118030

RESUMO

Percutaneous peritoneal catheter insertion can be performed by trained nephrologists. The objective of this study was to compare the outcome of peritoneal dialysis (PD) catheters percutaneous inserted with the traditional surgical technique. One hundred twenty-one PD catheters were placed in 121 stage-5 Chronic kidney disease patients using three techniques: percutaneous insertion (Group P, n = 53), percutaneous insertion guided by radioscopy (Group R, n = 26), and surgical insertion (Group S, n = 42). The mean age of the whole cohort was 57 ± 16 years and 54% were male. Patients and catheter outcomes were followed up prospectively for 19 months. Gender, age, body mass index, previous abdominal surgeries, and the prevalence of diabetes mellitus were not significantly different among the groups as well as the incidence of bleeding and the presence of catheter dysfunction. In addition, the incidence of exit-site infections and peritonitis was not significantly different among the groups. Finally, the survival catheter rate was not significantly different by the end of the follow-up of 19 months (70% in P group, 85% in R, and 70% in S group (log rank = 0.88, p = 0.95). The outcome of percutaneous implanted catheters, which were inserted by a trained nephrologist, did not demonstrate to be inferior as compared with the traditional surgical approach.


Assuntos
Cateterismo/instrumentação , Cateteres de Demora , Falência Renal Crônica/terapia , Cavidade Peritoneal/cirurgia , Diálise Peritoneal/instrumentação , Brasil/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/epidemiologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Rev Col Bras Cir ; 39(5): 401-7, 2012.
Artigo em Inglês, Português | MEDLINE | ID: mdl-23174792

RESUMO

OBJECTIVE: To analyze the relation between vitamin D insufficiency and wound healing in patients with venous ulcers; to correlate vitamin D insufficiency with characteristics of the ulcer (size and pain) and to evaluate if reposition of vitamin D in these subjects expedites ulcer healing. METHODS: We selected 26 patients with leg ulcers, and 26 control patients without ulcers, matched for gender, age, systemic arterial hypertension and tobacco use. The venous ulcer group was divided in two subgroups: one that received placebo (nine patients) and other receiving vitamin D, 50.000 IU per week over two months (13 patients). Blood was collected for 25 OH vitamin D dosage before and after the medication. In the ulcer group, we obtained data concerning demographics, leg ulcer size, as well as pain severity, measured by an analogical visual scale. Data was grouped in contingency and frequency tables, the tests of Fisher and chi-squared being used for nominal variables and Mann-Whitney for numerical variables. The adopted significance was of 5%. RESULTS: We found vitamin D insufficiency in the great majority of the patients. The median level in the ulcer group was 17.05 ng/dl and 22.75 ng/dl in the group without ulcer (p=0,0182) No relation was found between the ulcer size without treatment and the level of vitamin D. After treatment, the average size of the ulcer changed from 25 cm² to 18 cm² in the patients that took vitamin D and from 27 cm² to 24,5 cm² in the placebo group (p=0,7051 and p=0,7877, respectively). Considering the variability of the size of the ulcer in the treatment group versus placebo group, the average size was equal to -0,75 cm² in the first group and +4cm² in the second (p=0,0676) CONCLUSION: Patients with leg ulcers have more vitamin D deficiency. No difference in the ulcer characteristics was noted between those with and without vitamin D deficiency. There was a trend toward a better healing in those with vitamin D reposition.


Assuntos
Úlcera Varicosa/tratamento farmacológico , Vitamina D/uso terapêutico , Vitaminas/uso terapêutico , Cicatrização/efeitos dos fármacos , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fenômenos Fisiológicos da Pele/efeitos dos fármacos , Úlcera Varicosa/etiologia , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/tratamento farmacológico
7.
Rev Col Bras Cir ; 39(3): 178-82, 2012.
Artigo em Inglês, Português | MEDLINE | ID: mdl-22836564

RESUMO

OBJECTIVES: 1) To assess the changes in body weight and body mass index in grade 2 and 3 obese patients with type 2 diabetes mellitus, pre and postoperatively; 2) to assess the changes in pre and postoperative fasting blood glucose, postprandial glucose, glycated hemoglobin and insulin. METHODS: A prospective study was undertaken with 40 selected patients with grade 2 and 3 obesity and type 2 diabetes mellitus, all with indication for surgical treatment of obesity. All patients underwent Roux-en-Y gastric bypass without ring. The clinical parameters weight and body mass index were analyzed, as well as the laboratory parameters fasting blood glucose, postprandial glucose, glycated hemoglobin, and insulin. The analyses were carried out in the preoperative period and at 60 days postoperatively. Statistical analysis was conducted with Student's t and the Kolmogorov-Smirnov tests. RESULTS: Mean preoperative weight was 107.3 kg, declining to 89.5 kg postoperatively. Mean initial body mass index was 39.5 kg/m², and 32.9 kg/m² at 60 postoperative days. Preoperative fasting blood glucose was 132 mg/dL, which was reduced to 40.4 mg/dL, on average, postoperatively. Postprandial blood glucose was 172 mg/dL in the preoperative period and 111.6 mg/dL in the postoperative measurement. Initial glycated hemoglobin was 7%, declining to 5.7% postoperatively. Preoperative and postoperative insulin levels were 29.6 µIU/mL and 13.9 µIU/mL, respectively. The level of significance was p<0.001 for all variables. CONCLUSION: There was a statistically significant reduction in body weight and body mass index between the pre and postoperative periods, as well as in fasting blood glucose, postprandial glucose, glycated hemoglobin.


Assuntos
Diabetes Mellitus Tipo 2/complicações , Derivação Gástrica , Obesidade/complicações , Obesidade/cirurgia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
J Am Soc Nephrol ; 22(10): 1939-45, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21852579

RESUMO

There is growing concern about the development of antibacterial resistance with the use of antibiotics in catheter lock solutions. The use of an antibiotic that is not usually used to treat other serious infections may be an alternative that may reduce the clinical impact should resistance develop. We conducted a randomized controlled trial to compare a solution of minocycline and EDTA with the conventional unfractionated heparin for the prevention of catheter-related bacteremia in hemodialysis patients during a period of 90 d. The study included 204 incident catheters (27.8% tunneled); 14 catheters were excluded because of early dysfunction and 3 because of protocol violations. We observed catheter-related bacteremia in 19 patients in the heparin group (4.3 per 1000 catheter-days) and in 5 patients in the minocycline-EDTA group (1.1 per 1000 catheter-days; P = 0.005). We did not detect a significant difference in the rate of catheter removal for dysfunction. Catheter-related bacteremia-free survival was significantly higher in the minocycline-EDTA group than in the heparin group (P = 0.005). In conclusion, a minocycline-EDTA catheter lock solution is effective in the prevention of catheter-related bacteremia in hemodialysis patients.


Assuntos
Antibacterianos/administração & dosagem , Bacteriemia/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Minociclina/administração & dosagem , Adulto , Idoso , Anticoagulantes/administração & dosagem , Bacteriemia/etiologia , Cateteres de Demora/microbiologia , Ácido Edético/administração & dosagem , Feminino , Heparina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Diálise Renal/instrumentação , Análise de Sobrevida
9.
Semin Dial ; 21(3): 269-73, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18248519

RESUMO

Both physical examination (PE) and intra-access pressure (IAP) measurements have been used in the identification of stenosis in an arteriovenous access. The aim of this study was to evaluate the accuracy of PE and IAP in the diagnosis of arteriovenous fistula (AVF) stenosis. A total of 84 patients were enrolled in the study (54% men, mean age of 50.7 +/- 12.7 years and mean AVF patency of 24.9 +/- 7.8 months, 52% radiocephalic). Abnormalities of pulse and thrill were used as the diagnostic tools for the detection of stenosis using the physical examination. For IAP, stenosis was suspected when the ratio between IAP at the arterial puncture site and the mean blood pressure was <0.13 or >0.43. The diagnosis of stenosis was confirmed by Doppler ultrasound (DU). Sensitivity (S), specificity (SP), positive predictive value (PPV), negative predictive value (PNV), and accuracy were calculated for the two early detection tests. According to DU, 50 (59%) AVF were considered positive for the presence of stenosis. Fifty-six (66%) AVF were considered positive for the presence of stenosis by PE and 34 (40%) by IAP. S, SP, PPV, and NPV for PE and IAP were 96%, 76%, 86%, and 93% and 60%, 88%, 88%, and 60%, respectively. The accuracy for PE and IAP was 88% and 71%, respectively. PE proved to be an accurate method for the diagnosis of stenosis and should be part of all surveillance protocols of stenosis detection in AVF.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Exame Físico , Adulto , Determinação da Pressão Arterial , Intervalos de Confiança , Constrição Patológica/diagnóstico , Feminino , Humanos , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Diálise Renal , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA