Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Hazard Mater ; 140(1-2): 211-20, 2007 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-16876938

RESUMO

Wastes of Araucaria angustifolia (named pinhão) natural (PW) and also loaded with Congo red (CRP) were tested as low-cost adsorbents for Cu(II) removal from aqueous solutions. In order to reduce the total number of experiments to achieve the best conditions of the batch adsorption procedure, three sets of statistical designs of experiments were carried-out for each adsorbent. Initially, a full 2(4) factorial design for each adsorbent with two central points (18 experiments) were performed, to optimize the following factors: mass of adsorbent (m), pH, time of contact (t) and initial metallic ion concentration (Co). These results indicated that almost all the main factors and its interactions were significant. It was verified for both adsorbents, that a mass of 30.0mg leaded to higher Cu(II) uptake and that the best pH for Cu(II) adsorption was 5.6. In order to continue the batch adsorption optimization of the systems, a central composite surface analysis design with two factors (Co, t) containing 13 experiments, divided in to four cube points, four axial points and five centre points was carried-out for each adsorbent. By performing these two sets of statistical design of experiments, the best conditions for Cu(II) uptake using pinhão wastes (PW) and pinhão wastes loaded with Congo red (CRP) using batch adsorption system, where: m=30.0mg of adsorbent; pH 5.6; t=2.5h. After optimizing the batch adsorption system by statistical design of experiments, isotherms for Cu(II) uptake using PW and CRP were performed. These isotherms fitted to the linear Langmuir and Freundlich models.


Assuntos
Cobre/isolamento & purificação , Resíduos Industriais/prevenção & controle , Modelos Químicos , Adsorção , Vermelho Congo , Concentração de Íons de Hidrogênio , Projetos de Pesquisa
2.
J Colloid Interface Sci ; 302(2): 396-407, 2006 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-16920134

RESUMO

7-Amine-4-azaheptylsilica (AAH Si) and 10-amine-4-azadecylsilica (AAD Si) were prepared and used for removal of Cu(II), Pb(II), and Fe(III) from aqueous solutions. Full 2(3) factorial designs with two pseudo-central points were carried out in order to achieve the best conditions of the batch adsorption procedure for metallic ion uptake by the adsorbents. To continue the optimizations, central composite surface design was also employed. These two independent statistical designs of experiments lead to the following conditions: m=30.0 mg of adsorbent; pH 6.0 for Cu(II) and Pb(II), pH 4.0 for Fe(III); t of contact 180 min to guarantee equilibration at higher adsorbate concentration. After optimization of the conditions, isotherms of the metallic ions adsorbed on the AAH Si and AAD Si adsorbents were obtained, which were fitted to nonlinear Langmuir and Freundlich isotherm models.


Assuntos
Aminas/química , Cobre/química , Ferro/química , Chumbo/química , Compostos de Organossilício/química , Projetos de Pesquisa/estatística & dados numéricos , Adsorção , Aminas/síntese química , Compostos de Organossilício/síntese química , Tamanho da Partícula , Propriedades de Superfície
3.
J Hazard Mater ; 133(1-3): 143-53, 2006 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-16297543

RESUMO

In order to reduce the total number of experiments for achieving the best conditions for Cr(VI) uptake using Araucaria angustifolia (named pinhão) wastes as a biosorbent, three statistical design of experiments were carried out. A full 2(4) factorial design with two blocks and two central points (20 experiments) was experimented (pH, initial metallic ion concentration-C(o), biosorbent concentration-X and time of contact-t), showing that all the factors were significant; besides, several interactions among the factors were also significant. These results led to the performance of a Box-Behnken surface analysis design with three factors (X, C(o) and t) and three central points and just one block (15 experiments). The performance of these two statistical designs of experiments led to the best conditions for Cr(VI) biosorption on the pinhão wastes using a batch system, where: pH 2.0; C(o) = 1200 mg l(-1) Cr(VI); X = 1.5 g l(-1) of biosorbent; t = 8 h. The maximum Cr(VI) uptake in these conditions was 125 mg g(-1). After evaluating the best Cr(VI) biosorption conditions on pinhão wastes, a new Box-Behnken surface analysis design was employed in order to verify the effects of three concomitant ions (Cl(-), NO(3)(-) and PO(4)(3-)) on the biosorption of Cr(VI) as a dichromate on the biosorbent (15 experiments). These results showed that the tested anions did not show any significant effect on the Cr(VI) uptake by pinhão wastes. In order to evaluate the pinhão wastes as a biosorbent in dynamic system, a glass column was fulfilled with pinhão wastes (4.00 g) as biosorbent, and it was fed with 25.0 mg l(-1) Cr(VI) at pH 2.0 and 2.5 ml min(-1). The breakpoint was attained when concentrations of effluent of the column attained the value of 0.05 mg l(-1) Cr(VI) using 5550 ml of the metallic ion solution. In these conditions, the biosorbent was able to remove completely Cr(VI) from aqueous solution with a ratio of Cr(VI) effluent volume/biosorbent volume of 252.3.


Assuntos
Cromo/química , Cromo/metabolismo , Esgotos , Traqueófitas/metabolismo , Adsorção , Concentração de Íons de Hidrogênio , Resíduos Industriais , Íons/química , Estrutura Molecular , Probabilidade , Soluções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA