1.
Water Environ Res ; 83(11): 2036-48, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22195426

RESUMO

Activated sludge modeling technology is maturing; however, currently, there exists a great need to increase its use in daily engineering practice worldwide. A good way for building the capacities of the practitioners is to promote good modeling practices and standardize the protocols. In this study, a systematic procedure was proposed to calibrate the Activated Sludge Model No. 1 (ASM1) at a large wastewater treatment plant, by which the model adequately predicted the quality of the effluent and the sludge quantities. A hydraulics model was set up and validated through a tracer test. The Vesilind settling constants were measured and combined with the default value of the flocculent zone settling parameter, to calibrate the clarifiers. A virtual anoxic tank was installed in the return activated sludge to mimic the denitrification occurring in the settlers. In ASM1, the calibrated parameters were only two influent chemical oxygen demand fractions and one kinetic constant (oxygen half-saturation coefficient).


Assuntos
Desnitrificação , Modelos Químicos , Esgotos , Poluentes Químicos da Água/isolamento & purificação , Calibragem
2.
Water Environ Res ; 83(2): 162-72, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21449478

RESUMO

For activated sludge modeling purposes, the methods used to evaluate the readily biodegradable chemical oxygen demand (RBCOD) in the influents are by biological or via physicochemical assays. However, there has not been sufficient wide comparison between these methods. The main goal of this study was to investigate the performance of the main chemical oxygen demand (COD) fractionation protocols, considering a representative wastewater in the context of tropical and developing countries. Different physicochemical characterization procedures, respirometric tests, and chemical analyses were performed. The fate of the soluble COD in the aeration tanks was studied. The results of the study showed that a marked difference may exist, in municipal wastewaters, between the estimates of the RBCOD fractions measured by respirometry and by any of the physicochemical methods. The evaluated influent showed a rather large fraction of COD that was passing the filters without being rapidly biodegradable, but which was removed quickly by enmeshment in the bioflocs. The consequences of such divergences and behavior are discussed.


Assuntos
Biodegradação Ambiental , Reatores Biológicos , Consumo de Oxigênio/fisiologia , Eliminação de Resíduos Líquidos , Monitoramento Ambiental , Poluentes Químicos da Água