1.
Braz. dent. sci ; 27(2): 1-12, 2024. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1551332

RESUMO

Objective: In response to the demand for dental implants, extensive research has been conducted on methods for transferring load to the surrounding bone. This study aimed to evaluate the stresses on the peripheral bone, implants, and prostheses under scenarios involving of the following variables: prosthesis designs, vertical bone heights, load angles, and restorative materials. Material and Methods: Three implants were inserted in the premolar and molar regions (5-6-7) of the two mandibular models. Model 1 represented 0 mm marginal bone loss and Model 2 simulated 3 mm bone loss. CAD/CAM-supported materials, hybrid ceramic (HC), resin-nano ceramic (RNC), lithium disilicate (LiSi), zirconia (Zr), and two prosthesis designs (splinted and non-splinted) were used for the implant-supported crowns. Forces were applied vertically (90°) to the central fossa and buccal cusps and obliquely (30°) to the buccal cusps only. The stresses were evaluated using a three-dimensional Finite Element Analysis. Results: Oblique loading resulted in the highest stress values. Of the four materials, RNC showed the low stress in the restoration, particularly in the marginal area. The use of different restorative materials did not affect stress distribution in the surrounding bone. The splinted prostheses generated lower stress magnitude on the bone, and while more stress on the implants were observed. Conclusion: In terms of the stress distribution on the peri-implant bone and implants, the use of different restorative materials is not important. Oblique loading resulted in higher stress values, and the splinted prosthesis design resulted in lower stress (AU)


Objetivo: Em resposta à demanda por implantes dentários, extensa pesquisa foi realizada sobre métodos para transferir carga ao osso circundante. Este estudo buscou avaliar os estresses no osso periférico, implantes e próteses em cenários que envolvem as seguintes variáveis: designs de próteses, alturas ósseas verticais, ângulos de carga e materiais restauradores. Material e Métodos: Três implantes foram inseridos nas regiões dos pré-molares e molares (5-6-7) de dois modelos de mandíbula. O Modelo 1 representou perda óssea marginal de 0 mm e o Modelo 2 simulou perda óssea de 3 mm. Materiais suportados por CAD/CAM, cerâmica híbrida (HC), cerâmica nano-resina (RNC), dissilicato de lítio (LiSi), zircônia (Zr) e dois designs de próteses (sintetizadas e não-sintetizadas) foram utilizados para as coroas suportadas por implantes. Forças foram aplicadas verticalmente (90°) à fossa central e cúspides bucais e obliquamente (30°) apenas às cúspides bucais. Os estresses foram avaliados usando Análise de Elementos Finitos tridimensional. Resultados: Cargas oblíquas resultaram nos valores mais altos de estresse. Entre os quatro materiais, RNC mostrou baixo estresse na restauração, especialmente na área marginal. O uso de diferentes materiais restauradores não afetou a distribuição de estresse no osso circundante. Próteses sintetizadas geraram menor magnitude de estresse no osso, enquanto mais estresse nos implantes foi observado. Conclusão: Em termos de distribuição de estresse no osso peri-implantar e implantes, o uso de diferentes materiais restauradores não é crucial. Cargas oblíquas resultaram em valores mais altos de estresse, e o design de prótese sintetizada resultou em menor estresse. (AU)


Assuntos
Implantes Dentários , Prótese Dentária , Análise de Elementos Finitos , Fenômenos Biomecânicos
2.
São José dos Campos; s.n; 2024. 81 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1552084

RESUMO

O objetivo deste estudo foi avaliar o comportamento biomecânico através da resistência à fadiga e análise por elementos finitos de coroas bioinspiradas bilaminadas com infraestruturas modificadas na superfície vestibular (Estudo A) e utilizando diferentes materiais cerâmicos com módulos elásticos distintos (Estudo B). Para isso, foram confeccionados 90 preparos para coroa total em resina epóxi G10, sobre os quais foram preparadas coroas bioinspiradas de acordo com os seguintes grupos: Estudo A - IC (infraestrutura convencional), IME (infraestrutura modificada estratificada) e IMC (infraestrutura modificada cimentada), todas confeccionadas em dissilicato de lítio (infraestrutura) + porcelana (recobrimento); Estudo B ­ DL+LEU (dissilicato de lítio + leucita), LEU+DL (leucita + dissilicato de lítio), CH+DL (cerâmica híbrida + dissilicato de lítio) e CH+LEU (cerâmica híbrida + leucita). Para o Estudo A, todas as infraestruturas foram usinadas; os recobrimentos dos grupos IC e IME foram confeccionados através da estratificação, e os recobrimentos do grupo IMC foram usinados. Já para o Estudo B, todas as peças foram usinadas, de acordo com o material cerâmico de cada grupo. Em seguida, foi realizada a cimentação adesiva dos recobrimentos sobre as infraestruturas (a depender do grupo) e das coroas sobre os preparos utilizando cimento resinoso fotopolimerizável (Variolink Esthetic LC). Após a cimentação, os espécimes foram submetidos ao teste de fadiga cíclica (10.000 ciclos, 20Hz), e como desfecho foram considerados dois eventos, em que o primeiro foi a ocorrência de trinca e/ou lascamento (evento 1) e o segundo foi a falha catastrófica do conjunto (evento 2). Os valores de carga e número de ciclos para falha em que foram observados os eventos 1 e 2 foram utilizados para realizar a análise de sobrevivência de acordo com Kaplan-Meier e Log-Rank (Mantel-Cox; 95%). As marcas de fratura e o modo de falha das coroas foram avaliados e classificados por estereomicroscópio óptico e microscópio eletrônico de varredura. Por fim, foi realizada análise por elementos finitos (FEA) para ambos os estudos, a fim de avaliar a distribuição de tensões sobre as coroas e interface adesiva. Para o Estudo A, os resultados do teste de fadiga mostraram que, considerando o evento 1 (trinca/lascamento), os grupos IC e IMC apresentaram médias de carga fadiga estatisticamente significantes entre si (733,33 N e 913,33 N, respectivamente), enquanto o grupo IME apresentou média superior (1.020 N). O mesmo foi observado para o número de ciclos em fadiga para todos os grupos. Ao considerar o evento 2 (falha catastrófica), os três grupos apresentaram médias estatisticamente semelhantes entre si (~1.028 N). Os resultados de FEA mostraram que o grupo IC concentrou maior tensão de tração do que os grupos IME e IMC. Para o Estudo B, no teste de fadiga, o grupo DL+LEU apresentou a maior média de resistência à fadiga (evento 1: 913,33 N e evento 2: 1033,33 N), enquanto todas as outras combinações de materiais cerâmicos analisadas foram estatisticamente semelhantes entre si, considerando carga e número de ciclos. Com relação ao FEA, os grupos com cerâmica híbrida (CH+DL e CH+LEU) apresentaram menores picos de concentração de tensão na infraestrutura do que os grupos com cerâmicas vítreas (DL+LEU e LEU+DL), porém, em contrapartida, concentraram maior tensão na interface adesiva. Com isso, conclui-se que a utilização da infraestrutura modificada é uma alternativa viável e promissora para tratamentos reabilitadores, apresentando sobrevivência em fadiga e distribuição de tensões satisfatórias. Além disso, a combinação entre uma infraestrutura de dissilicato de lítio e recobrimento de cerâmica a base de leucita corresponde a melhor abordagem considerando a infraestrutura modificada.(AU)


The objective of this study was to evaluate the biomechanical behavior through fatigue resistance and finite element analysis of bilaminar bioinspired crowns with modified infrastructures on the buccal surface (Study A) and using different ceramic materials with different elastic moduli (Study B). For this, 90 preparations were made for a full crown in G10 epoxy resin, on which bioinspired crowns were prepared according to the following groups: Study A - CI (conventional infrastructure), SMI (stratified modified infrastructure) and CMI (cemented modified infrastructure ), all made of lithium disilicate (infrastructure) + porcelain (veneer); Study B ­ LD+LEU (lithium disilicate + leucite), LEU+LD (leucite + lithium disilicate), HC+LD (hybrid ceramic + lithium disilicate) and HC+LEU (hybrid ceramic + leucite). For Study A, all infrastructures were machined; the coverings of the CI and SMI groups were made through stratification technique, and the veneers of the SMI group were machined. For Study B, all pieces were machined, according to the ceramic material of each group. Then, the veneers were cemented into their infrastructures (depending on the group) and crowns were cemented into preparations using light-cured resin cement (Variolink Esthetic LC). After cementing, the specimens were subjected to the cyclic fatigue test (10,000 cycles, 20Hz), and as an outcome two events were considered: the occurrence of cracking and/or chipping (event 1) and catastrophic failure (event 2). The load (N) and number of cycles to failure in which events 1 and 2 were observed were used to perform the survival analysis according to Kaplan-Meier and Log-Rank (Mantel- Cox; 95%). The fracture marks and failure mode of the crowns were evaluated and classified by optical stereomicroscope and scanning electron microscope. Finally, finite element analysis (FEA) was performed for both studies in order to evaluate the stress distribution over the crowns and adhesive interface. For Study A, the results of the fatigue test showed that, considering event 1 (cracking/chipping), the CI and CMI groups presented average to failure that were statistically significant compared to each other (733.33 N and 913.33 N, respectively), while the SMI group showed higher averages (1,020 N). Same pattern was observed for the number of cycles under fatigue for both groups. When considering event 2 (catastrophic failure), the three groups presented statistically similar means (~1,028 N). The FEA results showed that the CI group concentrated greater tensile stress than the CMI and SMI groups. For Study B, in the fatigue test, the LC+LEU group presented the highest average fatigue resistance (event 1: 913.33 N and event 2: 1033.33 N), while all other combinations of ceramic materials analyzed were statistically similar to each other, considering load and number of cycles. Regarding FEA, the groups with hybrid ceramics (HC+LC and HC+LEU) showed lower stress concentration peaks in the infrastructure than the groups with glass ceramics (LC+LEU and LEU+LC), however, on the other hand, concentrated greater tension at the adhesive interface. With this, it is concluded that the use of modified infrastructure is a viable and promising alternative for oral rehabilitation treatments, presenting satisfactory fatigue survival and adequate stress distribution. Furthermore, the combination of a lithium disilicate infrastructure and a leucite-based ceramic coating corresponds to the best approach considering the modified infrastructure.(AU)


Assuntos
Cerâmica , Análise de Elementos Finitos , Biomimética , Prótese Parcial Fixa , Fadiga
3.
Dental press j. orthod. (Impr.) ; 29(1): e2423195, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1534312

RESUMO

ABSTRACT Introduction: Surgically assisted rapid palatal expansion (SARPE) has been the treatment of choice in subjects presenting skeletally mature sutures. Objective: The purpose of this study was to analyze stress distribution and displacement of the craniofacial and dentoalveolar structures resulting from three types of palatal expanders with surgical assistance using a non-linear finite element analysis. Material and Methods: Three different palatal expanders were designed: Model-I (tooth-bone-borne type containing four miniscrews), Model-II (tooth-bone-borne type containing two miniscrews), and Model-III (bone-borne type containing four miniscrews). A Le Fort I osteotomy was performed, and a total of 5.0 mm palatal expansion was simulated. Nonlinear analysis (three theory) method (geometric nonlinear theory, nonlinear contact theory, and nonlinear material methods) was used to evaluate stress and displacement of several craniofacial and dentoalveolar structures. Results: Regardless of the maxillary expander device type, surgically assisted rapid palatal expansion produces greater anterior maxillary expansion than posterior (ANS ranged from 2.675 mm to 3.444 mm, and PNS ranged from 0.522 mm to 1.721 mm); Model-I showed more parallel midpalatal suture opening pattern - PNS/ANS equal to 54%. In regards to ANS, Model-II (1.159 mm) and Model-III (1.000 mm) presented larger downward displacement than Model-I (0.343 mm). PNS displaced anteriorly more than ANS for all devices; Model-III presented the largest amount of forward displacement for PNS (1.147 mm) and ANS (1.064 mm). All three type of expanders showed similar dental displacement, and minimal craniofacial sutures separation. As expected, different maxillary expander designs produce different primary areas and levels of stresses (the bone-borne expander presented minimal stress at the teeth and the tooth-bone-borne expander with two miniscrews presented the highest). Conclusions: Based on this finite element method/finite element analysis, the results showed that different maxillary expander designs produce different primary areas and levels of stresses, minimal displacement of the craniofacial sutures, and different skeletal V-shape expansion.


RESUMO Introdução: A expansão rápida da maxila assistida cirurgicamente (ERMAC) tem sido o tratamento de escolha em indivíduos que apresentam suturas esqueleticamente maduras. Objetivo: O objetivo deste estudo foi avaliar, utilizando uma análise não linear com elementos finitos, a distribuição de tensões e os deslocamentos das estruturas craniofaciais e dentoalveolares gerados por três tipos de expansores palatinos usados na ERMAC. Material e Métodos: Três tipos de expansores palatinos foram projetados: Modelo I (dento-osseossuportado com quatro mini-implantes), Modelo II (dento-osseossuportado com dois mini-implantes) e Modelo III (osseossuportado com quatro mini-implantes). Uma osteotomia Le Fort I foi realizada e foi simulada uma expansão palatina total de 5,0 mm. Um método de análise não linear (três teorias - teoria da não-linearidade geométrica, teoria do contato não linear e métodos para materiais não lineares) foi utilizado para avaliar a tensão e o deslocamento de diversas estruturas craniofaciais e dentoalveolares. Resultados: Independentemente do tipo de aparelho expansor palatino, a ERMAC produziu maior expansão anterior da maxila do que posterior (ENA variou de 2,675 mm a 3,444 mm e ENP variou de 0,522 mm a 1,721 mm); o Modelo I apresentou padrão de abertura mais paralela da sutura palatina mediana, com ENP/ENA igual a 54%. Com relação à ENA, o Modelo II (1,159 mm) e o Modelo III (1,000 mm) apresentaram maior deslocamento para baixo do que o Modelo I (0,343 mm). A ENP deslocou-se mais para anterior do que a ENA com todos os aparelhos; o Modelo III apresentou o maior deslocamento para anterior da ENP (1,147 mm) e da ENA (1,064 mm). Os três tipos de expansores apresentaram deslocamento dentário semelhante e separação mínima das suturas craniofaciais. Como esperado, diferentes designs de expansores palatinos produzem diferentes áreas primárias e níveis de tensões (o expansor osseossuportado apresentou tensão mínima nos dentes, e o expansor dento-osseossuportado com dois mini-implantes apresentou o maior). Conclusões: Com base nesse estudo de elementos finitos, os resultados mostraram que diferentes designs de expansores palatinos produzem diferentes áreas primárias e níveis de tensão, com deslocamento mínimo das suturas craniofaciais e diferentes expansões esqueléticas em forma de V.

4.
Belo Horizonte; s.n; 2024. 193 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1568066

RESUMO

A prótese obturadora (PO) permite o restabelecimento estético e funcional de indivíduos maxilectomizados. Os objetivos deste estudo foram: 1. avaliar pelo método de elementos finitos (MEF), o comportamento biomecânico de infraestruturas metálicas de próteses parciais removíveis obturadoras (PPRO) para uma maxila com ressecção do tipo Classe II de Aramany, variando o tipo de conector maior; 2. realizar uma revisão sistemática com meta-análise em rede sobre a eficácia da PO, e outros tratamentos na qualidade de vida de seus usuários. No primeiro estudo, um modelo virtual simulando uma maxila Classe II de Aramany com ressecção óssea do lado esquerdo, e ausência dos dentes 24, 25, 26 e 27 foi construído no programa Rhinoceros® 7.0, a partir de duas tomografias. Em seguida, três infraestruturas de PPRO digitais foram confeccionadas variando o tipo de conector maior: grupo controle com conector maior tipo placa palatina com extensão reduzida (GC), conector maior tipo placa palatina com extensão total (ME), e conector maior tipo barra anteroposterior com extensão reduzida (AP). A análise de elementos finitos foi realizada no software Optistruct 2022, e os resultados analisados no HyperView 2022. Os resultados foram avaliados de forma qualitativa por meio da observação visual das imagens gráficas com variação dos gradientes de cores, de acordo com a distribuição de tensão, e quantitativa por meio da tensão de von Mises (σVM), tensão máxima principal (σmax), tensão mínima principal (σmin) e deslocamento (mm). No segundo estudo foi realizada uma revisão sistemática com meta-análise em rede (PROSPERO #CRD42023430827). Foram incluídos ensaios clínicos randomizados (ECRs) e estudos de intervenção não randomizados (EINRs) com pacientes reabilitados com prótese obturadora como um dos tratamentos de reabilitação. Sete desfechos reportados pelos pacientes foram analisados separadamente para cada desenho de estudo, de acordo com os questionários de QV: aparência, mastigação, dor, contato social, fala, deglutição e QV geral. Os dados foram convertidos para o questionário UW-QOL v4, exceto o contato social que foi convertido para o EORTC QLQ-H&N35. Foi usada meta-análise em rede Bayesiana modelo randômico para calcular as diferenças médias, e intervalos de credibilidade de 95% (Crl) para cada comparação entre tratamentos. A interpretação seguiu a certeza da evidência por meio da abordagem GRADE para meta-análise e a diferença mínima importante (DMI). A revisão incluiu 4 ECRs e 9 EINRs. Sete tratamentos foram avaliados: pré-cirúrgico (considerado sem tratamento), obturador pós-cirúrgico, obturador provisório, obturador convencional, obturador suportado por implante, obturador magnético e retalho, totalizando 120 comparações de tratamentos em todos os sete desfechos. Verificou-se pelos resultados do primeiro estudo que CG e AP apresentaram comportamentos semelhantes, já ME apresentou maiores valores de tensão para praticamente todos os componentes do sistema. Nenhum dos grupos apresentou valores de deslocamento significativos. Para a revisão sistemática, observou-se que a estimativa de efeito de alguns tratamentos alcançou a DMI, entretanto, o intervalo de credibilidade cruzou a linha de efeito nulo, com certeza da evidência muito baixa, portanto, nenhum tratamento foi mais eficaz que o outro. Para ambos os estudos, mais estudos laboratoriais e ensaios clínicos randomizados são incentivados para confirmar as evidências encontradas.


The obturator prosthesis (OP) allows the restoration of speech, aesthetics, and oral function in patients with maxilectomized individuals. The objectives of the study were: 1. to evaluate, using the finite element analysis (FEA) methodology, the biomechanical behavior of metallic infrastructures of removable partial denture obturator (RPDO) for a maxilla with Aramany Class II resection, varying the type of major connector; 2. carry out a systematic review with network meta-analysis on the effectiveness of the OP and other treatments on the quality of life of its users. In the first study, a virtual model simulating an Aramany Class II maxilla with bone resection on the maxillary left side and absence of teeth 24, 25, 26 and 27 was developed using the Rhinoceros® 7.0 program based on two tomography scans. After obtaining the virtual model, three infrastructures digital RPDOs were created varying the type of major connector: major connector with reduced coverage (RPDO1), major connector with extensive coverage (RPDO2) and major connector with anteroposterior bar (RPDO3). The FEA analysis was carried out using the Optistruct 2022 software, and the results were analyzed using the HyperView 2022 software. The results were evaluated qualitatively through visual observation of graphic images with variation of color gradients according to the stress distribution and quantitative von Mises stress (σVM), maximum principal stress (σmax), minimum principal stress (σmin) and displacement (mm). For the second study, the systematic review with network meta-analysis (PROSPERO #CRD42023430827). Randomized controlled trials (RCTs) and non-randomized studies of intervention (NRSIs) with obturator prosthesis as one of the treatments were included. Seven patient-reported outcomes were analyzed separately for each study design, according to the QOL questionnaires: appearance, chewing, pain, social contact, speech, swallowing and general QOL. Data were converted to the UW-QOL v4 questionnaire, except social contact, which was converted to the EORTC QLQ-H&N35. Network meta-analysis (NMA) Bayesian random model was used to calculate mean differences (MD) and 95% credibility intervals (Crl) for each treatment comparison. Interpretation followed the certainty of evidence through the GRADE approach for NMA and the least important difference (DMI). The review included 4 RCTs and 9 NRSIs. Seven treatments were evaluated: presurgical (considered no treatment), surgical obturator, interim obturator, obturator, implant-supported obturator, magnet obturator, and flap, totaling 120 treatment comparisons in all seven outcomes. The results of the first study indicate that RPDO1 and RPDO3 showed similar behaviors, while RPDO2 presented the highest stress values for all system components. None of the groups presented significant displacement values. In the systematic review, it was observed that the effect estimates of some treatments reached the DMI, however, for all treatment comparisons, the credibility interval crossed the null effect line with very low certainty of evidence. No treatment showed superiority compared to another for any outcome. For both studies, further laboratory studies and RCTs are encouraged to confirm the evidence.


Assuntos
Análise de Elementos Finitos , Prótese Parcial , Prótese Maxilofacial , Reabilitação Bucal , Metanálise em Rede , Revisão Sistemática
5.
Rev. bras. ortop ; 59(2): 278-283, 2024. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1565384

RESUMO

Abstract Objective To evaluate the stability of osteotomies created in the subtrochanteric and trochanteric regions in a pediatric femur model fixed by flexible intramedullary rods. Methods Tomographic sections were obtained from a pediatric femur model with two elastic titanium rods and converted to a three-dimensional model. This model created a mesh with tetrahedral elements according to the finite element method. Three virtual models were obtained, and osteotomies were performed in different regions: mediodiaphyseal, subtrochanteric, and trochanteric. A vertical load of 85N was applied to the top of the femoral head, obtaining the displacements, the maximum and minimum main stress, and the equivalent Von Mises stress on the implant. Results With the applied load, displacements were observed at the osteotomy site of 0.04 mm in the diaphyseal group, 0.5 mm in the subtrochanteric group, and 0.06 mm in the trochanteric group. The maximum stress in the diaphyseal, subtrochanteric, and trochanteric groups was 10.4 Pa, 7.52 Pa, and 26.4 Pa, respectively. That is around 40% higher in the trochanteric group in regards to the diaphyseal (control). The minimum stress of the bone was located in the inner cortical of the femur. The equivalent Von Mises stress on the implants occurred at osteotomy, with a maximum value of 27.6 Pa in the trochanteric group. Conclusion In both trochanteric and subtrochanteric osteotomies, fixation stability was often lower than in the diaphyseal model, suggesting that flexible intramedullary nails are not suitable implants for proximal femoral fixations.


Resumo Objetivo Avaliar a estabilidade de osteotomias criadas nas regiões subtrocantérica e trocantérica em modelo de fêmur pediátrico, fixadas por hastes intramedulares flexíveis. Método A partir de um modelo de fêmur pediátrico com duas hastes elásticas de titânio, foram obtidos cortes tomográficos que foram convertidos para um modelo tridimensional. Neste modelo foi criado uma malha com elementos tetraédricos, de acordo com o método dos elementos finitos. Foram obtidos três modelos virtuais, e realizadas osteotomias em regiões diferentes: mediodiafisária, subtrocantérica e trocantérica. Foi aplicado um carregamento vertical de 85N no topo da cabeça do fêmur, obtidos os deslocamentos, a tensão máxima e mínima principal e tensão equivalente de Von Mises no implante. Resultados Com o carregamento aplicado foram observados deslocamentos no local da osteotomia de 0,04mm no grupo diafisário, 0,5mm no subtrocantérico e 0,06mm no trocantérico. A tensão máxima principal foi 10,4Pa, 7,52Pa e 26,4Pa nos grupos diafisário, subtrocantérico e trocantérico, respectivamente. Ou seja, a tensão máxima foi em torno de 40% maior no grupo trocantérico, em relação ao diafisário (controle). A face de tensão mínima do osso localizou-se na cortical interna do fêmur. A tensão equivalente de Von Mises nos implantes ocorreu na osteotomia, com valor máximo de 27,6Pa no grupo trocantérico. Conclusão Tanto nas osteotomias no nível trocantérico, quanto subtrocantérico, a estabilidade da fixação foi muitas vezes menor que no modelo diafisário, sugerindo que as hastes intramedulares flexíveis não são implantes adequados para as fixações proximais do fêmur.


Assuntos
Humanos , Criança , Osteotomia , Análise de Elementos Finitos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas , Modelos Anatômicos
6.
São José dos Campos; s.n; 2024. 73 p. ilus, tab.
Tese em Português | BBO - Odontologia | ID: biblio-1553188

RESUMO

Este estudo avalia o comportamento em fadiga e distribuição de tensões de três desenhos de preparo para overlays (n=21) (com preparo de istmo [IST], com preparo não retentivo [nRET] e sem preparo de istmo [sIST]) e o efeito do material restaurador (resina composta [Tetric CAD] e cerâmica vítrea reforçada por leucita [Empress CAD]) cimentados sobre resina epóxi G10. Com o objetivo de determinar os perfis de carregamento para o ensaio de vida acelerado step-stress (SSALT)), três espécimes de cada grupo foram testados monotônicamente, e os demais foram ensaiados até a fratura, em uma máquina de simulação de mastigação. O número de ciclos e a respectiva carga em que cada espécime falhou foi utilizado para análise de sobrevivência, assim como os dados de espécimes sobreviventes ao teste. Foi realizada a análise de probabilidade Weibull. O modo de falha dos espécimes foi avaliado por estereomicroscopia e microscopia eletrônica de varredura. O comportamento biomecânico foi avaliado utilizando a análise por elementos finitos, e a distribuição de tensão foi avaliada considerando os modelos isotrópicos, linearmente elásticos e homogêneos; uma carga axial (200 N) foi aplicada à superfície oclusal dos molares. A concentração de tensão nas restaurações, interfaces adesivas e estrutura dental foi analisada pelo critério de Tensão Máxima Principal. Houve diferença estatística no SSALT entre nRET-RC (1840,46N) e os demais grupos de estudo, no FEA os grupos LEU absorveram maiores picos de tensão e RC os menores. Os diferentes desenhos de preparo para overlay influenciam a resistência à fratura e a distribuição de tensões em restaurações de cerâmica reforçada com leucita e resina composta para CAD/CAM.(AU)


This study assessed the fatigue behavior and stress distribution of three preparation designs for overlays (n=21) (with isthmus preparation [IST], with non-retentive preparation [nRET], and without isthmus preparation [sIST]) and the effect of the restorative material (composite resin [Tetric CAD] and leucite-reinforced glass ceramic [Empress CAD]) cemented on G10 epoxy resin. To determine the loading profiles for the step-stress accelerated life test (SSALT), three specimens from each group were tested monotonically, and the remainder were tested until fracture, in a chewing simulation machine. The number of cycles and the corresponding load at which each specimen failed were used for survival analysis, along with data from surviving specimens. Weibull probability analysis was performed. The failure mode of the specimens was evaluated through stereomicroscopy and scanning electron microscopy. Biomechanical behavior was assessed using finite element analysis, and stress distribution was evaluated considering isotropic, linearly elastic, and homogeneous models; an axial load (200 N) was applied to the occlusal surface of the molars. Stress concentration in restorations, adhesive interfaces, and dental structure was analyzed using the Maximum Principal Stress criterion. There was a statistical difference in SSALT between nRET-RC (1840.46N) and the other study groups. In FEA, the LEU groups absorbed higher stress peaks, and RC groups absorbed lower ones. The different preparation designs for overlays influence the fracture resistance and stress distribution in leucite-reinforced ceramic and composite resin restorations for CAD/CAM.(AU)


Assuntos
Estresse Mecânico , Prótese Dentária , Análise de Elementos Finitos
7.
Rev. cir. traumatol. buco-maxilo-fac ; 23(2): 17-25, abr./jun 2023. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1537357

RESUMO

Introdução: A osteotomia Le Fort I possibilita a correção de deformidades dentofaciais que envolvem o terço médio da face. Para sua fixação, convencionou-se o emprego de quatro mini-placas nos pilares zigomático-maxilar e nasomaxilar. Propôs-se então, a dispensa da fixação do segmento posterior, surgindo questionamentos relacionados à capacidade biomecânica do sistema. Objetivos: Comparar o estresse biomecânico gerado em três meios distintos de fixação da osteotomia Le Fort I frente ao movimento de avanço sagital linear maxilar de 7mm. Metodologia: Trata-se de uma pesquisa experimental laboratorial, utilizando-se da análise de elementos finitos como ferramenta analítica, a fim de constatar qual das técnicas sofrerá maior estresse biomecânico. Resultados: Constatou-se que o estresse biomecânico gerado é maior quando aplicado em 4 pontos do que quando aplicado em apenas 2 pontos. Conclusão: Os resultados obtidos fornecem informações aos cirurgiões sobre a real necessidade do uso de fixação adicional de acordo com o método de fixação planejado. No entanto, deve ser interpretado de forma cautelosa, considerando-se as limitações deste estudo. Sendo assim, uma análise incipiente, que tem como intuito o fornecimento de evidência científica de grande significância.


Introducción: La osteotomía Le Fort I permite la corrección de deformidades dentofaciales que involucran el tercio medio de la cara. Para su fijación se acordó utilizar cuatro miniplacas en los pilares cigomaticomaxilar y nasomaxilar. Entonces se propuso prescindir de la fijación del segmento posterior, planteando interrogantes relacionados con la capacidad biomecánica del sistema. Objetivos: Comparar el estrés biomecánico generado en tres medios diferentes de fijación de la osteotomía Le Fort I frente a un movimiento de avance sagital lineal maxilar de 7mm. Metodología: Se trata de una investigación experimental de laboratorio, utilizando como herramienta analítica el análisis de elementos finitos, con el fin de comprobar cuál de las técnicas sufrirá un mayor estrés biomecánico. Resultados: Se encontró que el estrés biomecánico generado es mayor cuando se aplica en 4 puntos que cuando se aplica solo en 2 puntos. Conclusión: Los resultados obtenidos brindan información a los cirujanos sobre la necesidad real de utilizar fijación adicional de acuerdo al método de fijación planificado. Sin embargo, debe interpretarse con cautela, considerando las limitaciones de este estudio. Por tanto, un análisis incipiente, que pretende aportar evidencias científicas de gran trascendencia.


Introduction: The Le Fort I osteotomy allows the correction of dentofacial deformities involving the middle third of the face. For its fixation, it was agreed to use four mini plates on the zygomaticomaxillary and nasomaxillary pillars. It was then proposed to dispense with the fixation of the posterior segment, raising questions related to the biomechanical capacity of the system. Objectives: To compare the biomechanical stress generated in three different means of fixation of the Le Fort I osteotomy against a 7mm maxillary linear sagittal advancement movement. Methodology: This is an experimental laboratory research, using finite element analysis as an analytical tool, in order to verify which of the techniques will suffer greater biomechanical stress. Results: It was found that the biomechanical stress generated is greater when applied to 4 points than when applied to only 2 points. Conclusion: The results obtained provide information to surgeons about the real need to use additional fixation according to the planned fixation method. However, it should be interpreted with caution, considering the limitations of this study. Therefore, an incipient analysis, which aims to provide scientific evidence of great significance.


Assuntos
Osteotomia de Le Fort , Análise de Elementos Finitos , Cirurgia Ortognática , Fixação Interna de Fraturas
8.
Braz. dent. sci ; 26(2): 1-10, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1436570

RESUMO

The maxillary bone restriction can limit the implants position to support a full-arch prosthesis. Objective:Therefore, this study evaluated the biomechanical behavior of a full-arch prosthesis supported by six implants in different configurations: group A (implants inserted in the region of canines, first premolars and second molars), group B (implants inserted in the region of first premolar, first molar and second molar) and group C (implants in second premolar, first premolar and second molar). Material and Methods: The models were analyzed by the finite element method validated by strain gauge. Three types of loads were applied: in the central incisors, first premolars and second molars, obtaining results of von-Mises stress peaks and microstrain. All registered results reported higher stress concentration in the prosthesis of all groups, with group C presenting higher values in all structures when compared to A and B groups. The highest mean microstrain was also observed in group C (288.8 ± 225.2 µÎµ/µÎµ), however, there was no statistically significant difference between the evaluated groups. In both groups, regardless of the magnitude and direction of the load, the maximum von-Mises stresses recorded for implants and prosthesis displacements were lower in group A. Conclusion: It was concluded that an equidistant distribution of implants favors biomechanical behavior of full-arch prostheses supported by implants; and the placement of posterior implants seems to be a viable alternative to rehabilitate totally edentulous individuals. (AU)


A limitação óssea maxilar totais pode limitar o posicionamento dos implantes para suportar uma prótese de arco total. Objetivo: Sendo assim, este estudo avaliou o comportamento biomecânico de uma prótese de arco total suportada por seis implantes em diferentes configurações: grupo A (implantes inseridos na região de caninos, primeiros pré-molares e segundos molares), grupo B (implantes inseridos na região de primeiro pré-molar, primeiro molar e segundo molar) e grupo C (implantes em segundo pré-molar, primeiro pré-molar e segundo molar). Materiais e métodos: Os modelos foram analisados pelo método de elementos finitos validados por extensometria. Foram aplicados três tipos de cargas: nos incisivos centrais, primeiros pré-molares e nos segundos molares, obtendo resultados de picos de tensão de von-Mises e microdeformação. Todos os resultados registrados mostraram maior concentração de tensão na prótese de todos os grupos, sendo que o grupo C apresentou maiores valores em todas as estruturas quando comparado com os grupos A e B. A maior média de microdeformação também foi observada no grupo C (288,8 ± 225,2 µÎµ/µÎµ), no entanto, não houve diferença estatisticamente significativa entre os grupos avaliados. Em todos os grupos, independentemente da magnitude e direção da carga, as tensões máximas de von-Mises registradas para os implantes e deslocamentos de próteses foram menores no grupo A. Conclusão: Concluiu-se que a distribuição de implantes de forma equidistante favorece o desempenho biomecânico das próteses de arco total suportada por implantes; e o posicionamento de implantes posteriores parece ser uma alternativa viável para reabilitar indivíduos densdentados totais. (AU)


Assuntos
Fenômenos Biomecânicos , Implantes Dentários , Prótese Dentária , Análise de Elementos Finitos , Maxila
9.
Acta ortop. bras ; 31(2): e259557, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1439140

RESUMO

ABSTRACT Objective: To determine, by biomechanical analysis, safe patellar cut limits in anterior cruciate ligament (ACL) reconstruction that minimize fracture risks. Methods: From three-dimensional reconstruction, triangular cuts were made in the patella, with a depth of 6.5 mm and variable width and length (10 to 20 mm and 8 to 12 mm, respectively, both with an interval of 1 mm). The combinations of cuts constituted 55 models for tests, with five variations in width and 11 variations in length, tested with the finite element method (FEM). Results: The mean of the localized principal maximum (traction force) values was 4.36 Pa (SD 0.87 ± 0.76) and the localized principal minimum (compression force) was −4.33 Pa (SD 1.05 ± 1.11). Comparing width and length to the tension force of the values of the main maximum, we found statistical significance from 11 mm for width and 13 mm for length. Conclusion: In ACL reconstruction, the removal of the patellar bone fragment is safe for fragments smaller than 11 mm in width and 13 mm in length, which corresponds to 24% of the width and 28% of the length of the patella used. Level of Evidence II, Comparative Prospective Study.


RESUMO Objetivo: Determinar, por meio de análise biomecânica, os limites de corte patelar seguros para a reconstrução do ligamento cruzado anterior (LCA) e que minimizem riscos de fratura. Métodos: A partir de reconstrução tridimensional, foram feitos cortes triangulares na patela, com profundidade de 6,5 mm e largura e comprimento variáveis (8 a 12 mm e 10 a 20 mm), respectivamente, com intervalo de 1 mm). As combinações dos cortes constituíram 55 modelos para ensaios, com 5 variações de largura e 11 variações de comprimento, ensaiados por meio do método dos elementos finitos (MEF). Resultados: A média dos valores da máxima principal localizada (força de tração) foi de 4,36 Pa (DP 0,87 ± 0,76), e a mínima principal localizada (força de compressão) foi de −4,33 Pa (DP 1,05 ± 1,11). Comparando largura e comprimento à força de tensões dos valores da máxima principal, houve significância estatística a partir de 11 mm para largura e 13 mm para comprimento. Conclusão: Na reconstrução do LCA, a retirada do fragmento ósseo patelar mostrou-se segura para fragmentos menores que 11 mm de largura e 13 mm de comprimento, o que corresponde a 24% da largura e 28% do comprimento da patela utilizada. Nível de Evidência II, Estudo Prospectivo Comparativo.

10.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1411432

RESUMO

Objective: to analyze the stress distribution in a 3D model that simulates second molar mesialization using two different types of mini-implants. Material and Methods: a mandible bone model was obtained by recomposing a computed tomography performed by a software program. The cortical and trabecular bone, a lower second molar, periodontal ligament, orthodontic tube, resin cement and the mini-implants were designed and modeled using the Rhinoceros 4.0 software program. The characteristics of self-drilling orthodontic mini-implants were: one with 7 mm length, 1 mm transmucosal neck section and 1.6 mm diameter and another with 5 mm length and 1.5 mm diameter. A total of 235.161 and 224.505 elements were used for the mesh. These models were inserted into the bone block and then subjected to loads of 200 cN (centinewton). The results were calculated and analyzed by the Ansys 17.0 software program for qualitative verification through displacement and maximum principal stress maps. Results: it was possible to observe that the periodontal ligament presented low displacement and stress values. However, the physiological values presented are among those capable to provide orthodontic movement, with compression and tensile area visualization staggered between 0.1 and -0.1 MPa (megapascal). Conclusion: within the limitations of the study, the mini-implants tested showed similar results where the load on the tooth allowed dental displacement (molar mesialization), with a tendency to rotate it, theoretically allowing the second molar to take the location of the first molar. (AU)


Objetivo: analisar a distribuição de tensões em um modelo 3D que simula a mesialização do segundo molar usando dois tipos diferentes de mini-implantes. Material e Métodos: um modelo de osso mandibular foi obtido por recomposição de uma tomografia computadorizada realizada por um software. O osso cortical e trabecular, um segundo molar inferior, ligamento periodontal, tubo ortodôntico, cimento resinoso e os mini-implantes foram projetados e modelados no software Rhinoceros 4.0. As características dos mini-implantes ortodônticos auto perfurantes foram: um com 7 mm de comprimento, 1 mm de secção transmucosa e 1,6 mm de diâmetro e outro com 5 mm de comprimento e 1,5 mm de diâmetro. Para a malha, foram utilizados 235.161 e 224.505 elementos. Esses modelos foram inseridos no bloco ósseo e então submetidos a cargas de 200 cN (centinewton). Os resultados foram calculados e analisados pelo software Ansys 17.0 para verificação qualitativa por meio de mapas de deslocamento e tensões máximas principais. Resultados: foi possível observar que o ligamento periodontal apresentou baixos valores de deslocamento e tensões. Porém, os valores fisiológicos apresentados são capazes de proporcionar movimentação ortodôntica, com visualização da área de compressão e tração escalonada entre 0,1 e -0,1 MPa (megapascal). Conclusão: dentro das limitações do estudo, os mini-implantes testados apresentaram resultados semelhantes onde a carga sobre o dente permitiu o deslocamento dentário (mesialização do molar), com tendência a girá-lo, permitindo teoricamente que o segundo molar ocupe do lugar do primeiro molar (AU)


Assuntos
Avulsão Dentária , Implantes Dentários , Análise de Elementos Finitos , Procedimentos de Ancoragem Ortodôntica , Aparelhos Ortodônticos Fixos