Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec. (Online) ; 74(5): 948-953, Sep.-Oct. 2022. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1403408

RESUMO

The aim of this study was to develop a modified tibial plateau leveling osteotomy (TPLO) plate and to compare its biomechanical properties with a locking compression plate (LCP) and plate-rod constructs for the stabilization of experimentally induced gap fractures in canine synthetic tibias. The tibial models were assigned to either repair with a modified TPLO plate (Group 1), locking compression plate construct (Group 2), or plate-rod construct (Group 3). The specimens were loaded to failure in axial compression, three-point mediolateral and craniocaudal bending. There was no statistical difference between the three groups regarding stiffness (N/mm) and deformation (mm) in axial compression. The modified TPLO plate achieved load to failure similar to the plate-rod construct in craniocaudal bending. There was no significant difference between groups on mediolateral bending tests regarding load to failure and deformation. Furthermore, there was no significant difference in stiffness between groups 1 and 2. In conclusion, the modified TPLO plate had similar mechanical properties to LCP and plate-rod construct in the axial compression and bending tests. Nonetheless, clinical studies with a large population of dogs are required to determine the value of this new implant in proximal tibial fracture repair.


Objetivou-se desenvolver uma placa de osteotomia niveladora do platô tibial (TPLO) modificada e compará-la biomecanicamente à placa de compressão bloqueada (LCP) e à construção placa-pino intramedular na estabilização da fratura cominutiva proximal em tíbias sintéticas caninas. Para tal, tíbias caninas sintéticas foram divididas em três grupos, sendo o grupo 1 formado pela placa de TPLO modificada, o grupo 2 por placas LCP e o grupo 3 pela construção placa-pino intramedular. Os espécimes foram submetidos à carga até a falha em compressão axial, flexão mediolateral e craniocaudal em três pontos. Não houve diferença estatística entre os três grupos quanto à rigidez (N/mm) e à deformação (mm) nos testes de compressão axial. A placa de TPLO modificada obteve carga até a falha semelhante à construção placa-pino intramedular em flexão craniocaudal. Não houve diferença significativa entre os grupos nos testes de flexão mediolateral em relação à carga até a falha e a deformação, e a variável rigidez não apresentou diferenças significativas entre os grupos 1 e 2. Em conclusão, a placa de TPLO modificada apresentou similaridade mecânica em comparação com a LCP e a construção placa-pino. No entanto, estudos clínicos são necessários para determinar o valor desse novo implante na fixação de fraturas tibiais proximais.


Assuntos
Osteotomia/veterinária , Fraturas da Tíbia/cirurgia , Placas Ósseas/veterinária , Fenômenos Biomecânicos
2.
Acta odontol. venez ; 52(3)2014. tab, graf
Artigo em Espanhol | LILACS | ID: lil-778021

RESUMO

El objetivo de este estudio fue evaluar el efecto de la deficiencia de estrógenos asociada con dieta hiperlipídica sobre la integridad de la mandíbula de ratas. Para este experimento se selecionaron Ratas Wistar fueron divididas en 4 grupos: Control (C4%), Control hiperlipídica19% (C19%), ovariectomizadas 4% (OVX4%) y Ovariectomizada 19% (OVX19%). El experimento empezó con la castración (90 días), seguida de dieta hiperlipídica durante 30 días. Al fin, la sangre fue recogida para el análisis de los niveles séricos de calcio, fósforo, fosfatasa alcalina y estradiol. El fósforo disminuyó cuando hay aumento de la fosfatasa alcalina en todos los grupos en comparación con el C4%. En las vértebras L4, los pesos inmersos y húmedos aumentarán con la castración y la dieta hiperlipídica, mientras que el porcentaje de materia orgánica y minerales disminuyeron. En las mandíbulas, los pesos inmersos, húmedos y la densidad ósea aumentaran con la castración, pero disminuyeron con la combinación de castración / dieta. En las cenizas de las mandíbulas, el porcentaje de magnesio aumentó significativamente en todos los grupos. En las pruebas biomecánicas de las vértebras L4 y fémur no se encontraron diferencias significativas entre los grupos. Sin embargo, los grupos alimentados con dieta hiperlipídica tuvieron una menor resistencia a la tensión aplicada en la mandíbula. Dentro de las limitaciones del estudio, se puede notar que en estas ratas, la deficiencia de esteroides sexuales asociada con la dieta hiperlipídica influye negativamente sobre la integridad del hueso mandibular...


The aim of this study was to evaluate the effect of estrogen deficiency associated with a high fat diet on bone integrity of the jaw of rats. The pregnant rats were evaluated by vaginal cytology were 90 days old, divided into four groups: Control (C4%), Control hiperlipídica19% (C19%), ovariectomized 4% (OVX4%) and Ovariectomized19% (OVX19%). The experiment began with castration (90 days), followed by feeding with a high fat diet for 30 days. At the end, blood was collected. Jaws, vertebrae L4 and femur were removed and prepared for analysis. There were no differences in food intake, the body length or in bone measurements. Serum calcium decreased in the castrated groups. The level of phosphorus decreased and alkaline phosphatase increased in all groups. Some differences were observed among physical parameters. L4 vertebrae, immersed and wet weights increased with castration and the high fat diet, while the percentage of organic material and mineral decreased. In the jaws, immersed and wet weights and bone density increased with castration, but decreased with the combination spaying/fat diet. Bone volume and percentage of water decreased with intake of high fat diet. In the ashes of the jaws percentages of magnesium were increased in all groups, without changes in calcium and phosphorus. Groups fed with high-fat diets had lower resistance to the applied voltage in the jaw. It was demonstrated in these rats that, the deficiency of sex steroids associated with a high fat diet negatively influences mandibular bone integrity...


Assuntos
Animais , Camundongos , Antagonistas de Estrogênios/química , Dieta Hiperlipídica , Hiperlipidemias/induzido quimicamente , Fosfatase Alcalina , Densidade Óssea , Mandíbula , Fósforo
3.
RBM rev. bras. med ; 67(esp.7)jun. 2010.
Artigo em Português | LILACS | ID: lil-564313

RESUMO

Objetivos: Analisar a resistência mecânica de 13 tipos de cimentos ósseos acrílicos comercializados em nosso país, testando suas propriedades físicas de resistência às forças de tração e de flexão e comparar a resistência dos cimentos ósseos sem antibiótico com seus similares com antibiótico. Método: Foram confeccionados corpos de prova de acordo com a norma regulamentadora vigente (ISO 5833 e ISO 527), utilizando os parâmetros Weibull, onde, para se obter resultados dentro do limite mínimo de erro aceitável de 5%, o número de espécimes testados deve ser de 7 a 11 corpos de provas. Foram selecionamos nove corpos de prova para cada marca. Os testes de tração e de flexão foram realizados no Departamento de Materiais da Faculdade de Odontologia da Universidade de São Paulo - SP com a máquina de ensaio universal Riehle modelo Fs-5, com capacidade de 2.400 kg e com velocidade de 0,02 a 2 polegadas/segundo. Foram anotadas a força (MPa) no momento de fratura dos nove corpos de prova para cada cimento, assim como a média e desvio padrão para o teste de tração e flexão. O estudo estatístico foi realizado pelo teste de contraste de Tukey e pelo teste da análise de variância comparando-se as médias das amostras de cada cimento utilizado. Resultados: Observamos diferença significante entre as amostras selecionadas neste trabalho e diminuição significante na resistência mecânica das amostras que continham antibiótico na sua fórmula original em comparação com seus similares sem antibiótico. Conclusões: Os cimentos ósseos apresentaram diferenças significantes quanto à resistência mecânica à tração e à flexão. A presença de antibiótico na composição original dos cimentos ósseos diminuiu significantemente a resistência mecânica nos testes de tração e flexão.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA