Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 465
Filtrar
1.
Braz J Infect Dis ; 28(4): 103848, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39032516

RESUMO

BACKGROUND: The Amazonas state/AM and Manaus rank among the highest AIDS detection rates in Brazil. High proportion of HIV infected blood donors and transmission clusters of multidrug antiretroviral/ARV resistant viruses were described in HEMOAM blood donors, a main Amazonas public blood bank. Recent and long-term infections among previously genotyped donors are reported. METHODS/MATERIALS: The recency immunoassay Lag Avidity EIA (Maxim, USA) was employed. Clinical/CD4/viral load medical file data of the main local HIV management center (FMT-HVD) and ARV treatment/ART data were reviewed. RESULTS: Among 142 HIV-blood donors, chronic infection predominated (n = 87; 61.3 %), 79 based on LAg EIA and 8 undisclosed HIV identified in FMT-HVD records, mostly young adult, single males, 4 repeat donors, all ART-naive. Recent infections represented 30.3 % (n = 43), 39 identified by LAg EIA and 4 immunologic windows (antibody negative/NAT/RNA positive). The overall profile of recent and long-term infections was similar, including moderate rate of transmitted drug resistance/TDR, however with multiple resistance mutations to more than one ARV-class, suggesting ART/failure. DISCUSSION: Recent/acute and undisclosed/long-term HIV infections represent blood safety alerts suggesting test-seeking behavior of at-risk populations. Early ART use in Brazil, can turn HIV diagnosis more challenging representing a blood transfusion risk in the highly endemic Brazilian Amazon.


Assuntos
Doadores de Sangue , Infecções por HIV , Humanos , Doadores de Sangue/estatística & dados numéricos , Masculino , Brasil/epidemiologia , Infecções por HIV/epidemiologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/transmissão , Adulto , Feminino , Adulto Jovem , Pessoa de Meia-Idade , Doença Aguda , Carga Viral , Adolescente , Doenças Endêmicas , Contagem de Linfócito CD4 , HIV-1/genética , Doença Crônica
2.
Rev Fac Cien Med Univ Nac Cordoba ; 81(2): 302-317, 2024 06 28.
Artigo em Espanhol | MEDLINE | ID: mdl-38941225

RESUMO

Introduction: Metabolic syndrome (MS) is associated with increased cardiovascular risk. Blood donors are an apparently healthy population in which certain cardiometabolic characteristics are not evaluated in their selection, and there is limited information on their presence. Aim: To determine the frequency of metabolic syndrome and its metabolic characteristics in blood donors. Materials and methods: Cross-sectional study was carried in a population of 244 blood donors between 18 and 55 years of age who attended the Hemotherapy and Blood Bank Service of the Cayetano Heredia Hospital in Lima, Perú during the month of May 2023. The diagnosis of MS was made according to the Adult Treatment Panel III (ATP III) criteria. A bivariate analysis was performed between MS and metabolic characteristics with sex and a significance level of 5% was considered. Results: 63.9% of blood donors were male. 43.6% of the population had MS. The most frequent characteristics found were hypertriglyceridemia (54.5%), abdominal obesity (51.2%) and high-density lipoprotein (HDL) low (48.8%). The age range of 40 to 49 years presented the highest frequency of MS (14.3%). Hypertriglyceridemia and high blood pressure were associated with male sex (p=0.003 and p=0.019 respectively), while low HDL was associated with female sex (p<0.001). Conclusions: Blood donors present an elevated frequency of MS. The detection of MS in apparently healthy populations as part of primary care could allow the formulation of strategies for early detection of cardiovascular risk factors.


INTRODUCCIÓN: El síndrome metabólico (SM) está asociado a un incremento del riesgo cardiovascular. Los donantes de sangre son una población aparentemente sana en donde ciertas características cardiometabolicas no son evaluadas en su selección, existiendo limitada información sobre su presencia. OBJETIVO: Determinar la frecuencia de síndrome metabólico y sus características metabólicas en donantes de sangre. Materiales y métodos: Estudio transversal realizado en 244 donantes de sangre entre 18 y 55 años que acudieron al Servicio de Hemoterapia y Banco de sangre del Hospital Cayetano Heredia en Lima- Perú, durante el mes de mayo del 2023. Se realizó el diagnóstico de SM según los criterios del Adult Treatment Panel III (ATP III). Se realizó un análisis bivariado entre el SM y características metabólicas con el sexo y se consideró un nivel de significancia del 5%. RESULTADOS: El 63.9% de los donantes de sangre fueron del sexo masculino. El 43.6 % de la población presentó SM. Las características más frecuentes fueron la hipertrigliceridemia (54.5%), obesidad abdominal (51.2%) y lipoproteina de alta densidad (HDL) bajo (48.8%). El rango de edad de 40 a 49 años presentó la mayor frecuencia de SM (14.3%). La hipertrigliceridemia y presión arterial elevada estuvieron asociadas al sexo masculino (p=0.003 y p=0.019 respectivamente), mientras que el HDL bajo al sexo femenino (p <0.001). CONCLUSIONES: Los donantes de sangre presentan una frecuencia elevada de SM. La detección de SM en poblaciones aparentemente sanas como parte de la atención primaria podría permitir formular estrategias de detección temprana de factores de riesgo cardiovascular.


Assuntos
Doadores de Sangue , Síndrome Metabólica , Humanos , Síndrome Metabólica/sangue , Síndrome Metabólica/epidemiologia , Masculino , Feminino , Doadores de Sangue/estatística & dados numéricos , Adulto , Estudos Transversais , Pessoa de Meia-Idade , Adulto Jovem , Adolescente , Peru/epidemiologia , Fatores de Risco , Obesidade Abdominal/epidemiologia , Obesidade Abdominal/sangue , Fatores Sexuais , Distribuição por Sexo
3.
Front Med (Lausanne) ; 11: 1380129, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38751980

RESUMO

Objective: Arboviruses pose a challenge in ensuring the supply of pathogen-free blood components because they are not routinely screened in blood banks, and blood components from infected asymptomatic donors could be transfused. This study aimed to detect and characterize arboviral infections in Colombian blood donors. Methods: In a cross-sectional study, the prevalence of dengue (DENV), Zika (ZIKV), and chikungunya (CHIKV) viruses and co-infections of blood donors were compared between an epidemic period (November 2019-February 2020, n = 462) and an endemic period (November 2021-August 2022, n = 1,119). Viral RNA from each donor serum was purified, and the viruses were detected using a previously standardized multiplex hemi-nested RT-PCR protocol. Subsequently, donors who tested positive were surveyed 15 days after the detection of the virus to identify clinical characteristics related to the arboviral infection. The prevalences of each virus were presented as percentages and compared between epidemic and endemic periods. Results: Significantly higher prevalences were found in the epidemic period compared with the endemic period for DENV (14.5 vs. 1.9%), ZIKV (7.8 vs. 0.3%), CHIKV (8 vs. 3.3%), and co-infections (4.3 vs. 0.2%). The survey response rate of positive donors in the two periods was 83/175 (47%). In total, 57% of the donors surveyed were asymptomatic. Symptomatic donors most frequently reported headache (31%), malaise (13%), arthralgia (10%), and fever/chills (8%). Conclusion: The prevalence observed in epidemic and endemic periods was higher than that reported in other studies in the Americas. The high proportion of asymptomatic cases found, in addition to the mild and nonspecific manifestations among the symptomatic, may limit the effectiveness of the donor selection criteria used to mitigate the risk of transfusion-transmitted arboviruses.

4.
Physiol Meas ; 45(5)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38749458

RESUMO

Objective.Diagnosis of incipient acute hypovolemia is challenging as vital signs are typically normal and patients remain asymptomatic at early stages. The early identification of this entity would affect patients' outcome if physicians were able to treat it precociously. Thus, the development of a noninvasive, continuous bedside monitoring tool to detect occult hypovolemia before patients become hemodynamically unstable is clinically relevant. We hypothesize that pulse oximeter's alternant (AC) and continuous (DC) components of the infrared light are sensitive to acute and small changes in patient's volemia. We aimed to test this hypothesis in a cohort of healthy blood donors as a model of slight hypovolemia.Approach.We planned to prospectively study blood donor volunteers removing 450 ml of blood in supine position. Noninvasive arterial blood pressure, heart rate, and finger pulse oximetry were recorded. Data was analyzed before donation, after donation and during blood auto-transfusion generated by the passive leg-rising (PLR) maneuver.Main results.Sixty-six volunteers (44% women) accomplished the protocol successfully. No clinical symptoms of hypovolemia, arterial hypotension (systolic pressure < 90 mmHg), brady-tachycardia (heart rate <60 and >100 beats-per-minute) or hypoxemia (SpO2< 90%) were observed during donation. The AC signal before donation (median 0.21 and interquartile range 0.17 a.u.) increased after donation [0.26(0.19) a.u;p< 0.001]. The DC signal before donation [94.05(3.63) a.u] increased after blood extraction [94.65(3.49) a.u;p< 0.001]. When the legs' blood was auto-transfused during the PLR, the AC [0.21(0.13) a.u.;p= 0.54] and the DC [94.25(3.94) a.u.;p= 0.19] returned to pre-donation levels.Significance.The AC and DC components of finger pulse oximetry changed during blood donation in asymptomatic volunteers. The continuous monitoring of these signals could be helpful in detecting occult acute hypovolemia. New pulse oximeters should be developed combining the AC/DC signals with a functional hemodynamic monitoring of fluid responsiveness to define which patient needs fluid administration.


Assuntos
Doadores de Sangue , Dedos , Fotopletismografia , Humanos , Projetos Piloto , Feminino , Masculino , Adulto , Dedos/irrigação sanguínea , Hemorragia/diagnóstico , Pessoa de Meia-Idade , Hipovolemia/diagnóstico , Hipovolemia/fisiopatologia , Oximetria , Doença Aguda , Adulto Jovem , Frequência Cardíaca
5.
Artigo em Inglês | MEDLINE | ID: mdl-38429196

RESUMO

INTRODUCTION: The prime responsibility of blood transfusion services in India is to provide safe blood. The donated blood is tested for human immunodeficiency virus (HIV), hepatitis B virus (HBV), hepatitis C virus (HCV), malaria and syphilis. In India, the screening of donated blood for syphilis is performed by rapid plasma reagin (RPR) or venereal disease research laboratory (VDRL), whereas the World Health Organization (WHO) recommends screening of syphilis in blood donors by enzyme-linked immunosorbent assay (ELISA). Therefore, the aim of this study was to evaluate the performance of RPR and ELISA with the Treponema pallidum hemagglutination assay (TPHA - the gold standard) for the detection of syphilis in blood donors. METHODS: In this cross-sectional study, 1524 consecutive whole blood donors were screened from April to October 2022. All blood samples collected during the study period were tested by RPR, ELISA and the TPHA and the results obtained were compared. RESULTS: The seroprevalence of syphilis in blood donors in this study was 0.06% by RPR and 0.72% by ELISA and TPHA. On considering ELISA and the TPHA as the gold standard, ELISA had comparable sensitivity (100%), a higher specificity (100% vs. 99.34%), a higher positive predictive value (PPV - 100% vs. 9.1%) and no biological false positive/false negative results (0 vs. 10 false negatives) when compared to RPR. CONCLUSION: ELISA performed better as a screening assay than RPR in the detection of syphilis in blood donors, which is in agreement with the WHO recommendations for syphilis testing in blood donors with low prevalence.

6.
J Med Virol ; 96(2): e29463, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38345135

RESUMO

We present the case of a breakthrough infection by hepatitis B virus (HBV), intending to warn about the challenge that HBV represents for transfusion safety. Virological markers for HBV infection were assayed during a blood donor screening by detection of HBsAg, anti-HBc, and viral nucleic acid (HBV DNA) by a nucleic acid test (NAT). Additionally, samples were analyzed for detection of immunoglobulin M anti-HBc, HBeAg, anti-HBe, and anti-HBs. A first-time donor repeatedly tested positive for HBV DNA by NAT and nonreactive for HBV-serological markers of infection. He stated having completed the anti-HBV vaccination schedule; thus, study of anti-Hbs resulted in reactive at protective level (18 mIU/mL). The donor denied clinical symptoms of hepatitis and remained healthy during the follow-up period. 95 days postdonation, NAT was negative, seroconversion of anti-HBc ab was detected, and a significant increase in anti-HBs concentration was measured (>1000 mIU/mL). This is the first case of HBV-breakthrough infection reported in Argentina and to our knowledge, this potential threat to transfusion safety is novel in an HBV low-endemic region with high coverage of HBV vaccination. The occurrence of breakthrough infections challenges the current protocols for the identification of HBV-infected subjects, could be a source of silent HBV transmission.


Assuntos
Vírus da Hepatite B , Hepatite B , Masculino , Humanos , Vírus da Hepatite B/genética , Infecções Irruptivas , Doadores de Sangue , DNA Viral/genética , Antígenos de Superfície da Hepatite B , Antígenos do Núcleo do Vírus da Hepatite B , Hepatite B/diagnóstico , Hepatite B/prevenção & controle , Hepatite B/epidemiologia , Anticorpos Anti-Hepatite B
8.
Trans R Soc Trop Med Hyg ; 118(2): 102-109, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37647457

RESUMO

BACKGROUND: Toxoplasmosis is one of the most common parasitic infections worldwide with varying prevalence between human populations. These variations are mainly associated with human exposure to risk factors. In this article, the seroprevalence of Toxoplasma gondii infection and the risk factors associated with infection in 1729 blood donors from São José do Rio Preto, São Paulo, Brazil were analysed. METHODS: The serological tests for detecting immunoglobulin M (IgM) and immunoglobulin G (IgG) anti-T. gondii were used. The risk factors associated with the infection were identified through the application of an epidemiological questionnaire. RESULTS: The prevalence of T. gondii infection was 48.0%. The following factors were identified in the final model after multiple logistic regression analysis: drinking raw milk (p=0.003; odds ratio [OR] 1.364 [confidence interval {CI} 1.1 to 1.7]), residing in a rural area (p<0.0001; OR 2.764 [CI 1.7 to 4.6]) and receiving a blood transfusion (p=0.015; OR 1.856 [CI 1.1 to 3.0]). CONCLUSIONS: The data obtained in this study showed that the blood donor population is exposed to risk factors related to infection by T. gondii. These data allow the establishment of control programs to contribute to public health in northwestern São Paulo state.


Assuntos
Toxoplasma , Toxoplasmose , Humanos , Doadores de Sangue , Estudos Soroepidemiológicos , Brasil/epidemiologia , Anticorpos Antiprotozoários , Toxoplasmose/parasitologia , Fatores de Risco , Imunoglobulina M
9.
Transfus Apher Sci ; 63(1): 103854, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38061923

RESUMO

BACKGROUND: Poor disinfection is the main cause of blood contamination, so its elimination is key to limiting the entry of bacteria into the collection system. With the advancement of antiseptic technology, antiseptics with sterile, disposable applicators are now available. AIM: To evaluate in situ two antiseptics (with and without applicators) for blood banks and to demonstrate in vitro antiseptic activity on bacterial biofilms of importance in transfusion medicine. METHODS: Antiseptic A (2% sterile solution of chlorhexidine gluconate/70% isopropyl alcohol provided with applicator) and bulk antiseptic B (10% povidone-iodine) were evaluated. The deferred blood donor arms were subjected to disinfection with antiseptics A and B and the contralateral arms were cultured to determine the baseline bacterial load (control). Antiseptic activity was assessed by ANOVA and logaritmic reduction values (LRV) and percentage reduction values (PRV) were calculated. Finally, the in vitro activity of antiseptic A was analyzed by confocal laser scanning microscopy (CLSM) on biofilm models. RESULTS: Prior to disinfection tests, commensal and clinically important bacteria were identified; antiseptic A showed post-disinfection bacterial growth rates of zero compared to controls (p < 0.0001). The frequency of bacterial growth with antiseptic B was 74%. A significant difference was identified between both antiseptics, where antiseptic A showed higher activity (p < 0.5468). LRV and PRV were 0.6-2.5/100% and 0.3-1.7/66.7-99.7% for antiseptics A and B, respectively. Through CLSM, disinfectant A (without applicator) showed lower in vitro antiseptic activity on the tested biofilms at the exposure times recommended by the manufacturer. CONCLUSIONS: Sterile solution of chlorhexidine gluconate/isopropyl alcohol with applicator showed advantages disinfection in deferred blood donors over povidone-iodine.


Assuntos
Anti-Infecciosos Locais , Clorexidina/análogos & derivados , Humanos , Anti-Infecciosos Locais/farmacologia , Povidona-Iodo/farmacologia , 2-Propanol , Bancos de Sangue
10.
Rev Panam Salud Publica ; 47: e162, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38089105

RESUMO

Objective: To evaluate the screening of blood samples for infectious disease markers at laboratories and blood banks in Latin America per the findings of an External Quality Assessment Program (EQAP). Methods: This qualitative analysis used data from the EQAP coordinated by the Fundação Pro Sangue Hemocentro de São Paulo with the support of the Pan American Health Organization to assess the performance of blood screening for infectious diseases from 2014 to 2018 in Latin America. Each participating laboratory or blood bank received an identical blind panel with 24 blood samples with variable reactivity for all the screening parameters. Panels were processed at each participating facility and results were returned to the Fundação Pro Sangue Hemocentro de São Paulo for individual and joint analyses. Two types of discrepant results were potential failures: false positive results (FPRs) and false nonreactive results (FNRRs). Results: A total of 23 136 samples were evaluated. Global rates of FPR, FNRR, and concordant results were 0.3%, 1.0% and 98.7%, respectively. Seven FNRRs were found for HBsAg (1.0%), 12 for syphilis (2.6%), and 21 for Chagas disease (2.9%). No FNRRs were found for the HIV, HCV, and HTLV viruses. The average accuracy of all the laboratories and blood banks participating in the EQAP during the study period was 99.5% (standard deviation, 0.5%). Conclusion: The findings of this qualitative analysis are positive for blood safety in Latin America, with an average accuracy of 99.5% among the participating laboratories and blood banks. This report reflects an important improvement in blood bank serological screening EQAP-PAHO report since the 2003.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA