Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 149
Filtrar
1.
Int Arch Otorhinolaryngol ; 28(2): e219-e225, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618593

RESUMO

Introduction Cochlear implant (CI) activation usually takes place at ∼ 30 days postoperative (PO). In our service, CI surgery is performed with local anesthesia and sedation, so activation is possible with the patient's cooperation, immediately after the CI surgery, still in the operating room (OR). Objective The objective of the present study was to provide the patient with hearing experience with the CI and to assess auditory perception immediately after surgery while still in the OR, as well as to compare impedance telemetry (IT), neural response telemetry (NRT), and comfort (C) level at two moments: in the OR and at the definitive activation, ∼ 30 days PO. Methods Nine adult patients (12 ears) with acquired (postlingual) deafness were included. Auditory perception was evaluated through the Ling Six Sound Check, musical instruments, and clapping, presented in two different programming maps, elaborated using t-NRT, and comparing IT, NRT, and C level between the two moments. Results We observed that while still in the OR, the patient can already present auditory detection and recognition responses. The values of IT, NRT threshold (t-NRT), and C on both dates differed, with statistical significance. Conclusion We concluded that it is possible to provide the patient with an auditory experience with the CI immediately after surgery, and that the auditory experience and the values of electrode IT, NRT, and C vary significantly between the two moments.

2.
Int Arch Otorhinolaryngol ; 28(2): e301-e306, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618606

RESUMO

Introduction Facial nerve stimulation (FNS) is a complication in cochlear implant (CI) when the electrical current escapes from the cochlea to the nearby facial nerve. Different management to reduce its effects are available, although changes might result in a less-than-ideal fitting for the CI user, eventually reducing speech perception. Objective To verify the etiologies that cause FNS, to identify strategies in managing FNS, and to evaluate speech recognition in patients who present FNS. Methods Retrospective study approved by the Ethical Board of the Institution. From the files of a CI group, patients who were identified with FNS either during surgery or at any time postoperatively were selected. Data collection included: CI manufacturer, electrode array type, age at implantation, etiology of hearing loss, FNS identification date, number of electrodes that generated FNS, FNS management actions, and speech recognition in quiet and in noise. Results Data were collected from 7 children and 25 adults. Etiologies that cause FNS were cochlear malformation, head trauma, meningitis, and otosclerosis; the main actions included decrease in the stimulation levels followed by the deactivation of electrodes. Average speech recognition in quiet before FNS was 86% and 80% after in patients who were able to accomplish the test. However, there was great variability, ranging from 0% in quiet to 90% of speech recognition in noise. Conclusion Etiologies that cause FNS are related to cochlear morphology alterations. Facial nerve stimulation can be solved using speech processor programming parameters; however, it is not possible to predict outcomes, since results depend on other variables.

3.
Braz J Otorhinolaryngol ; 90(4): 101428, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38603969

RESUMO

OBJECTIVE: This is a retrospective analysis of the major and minor complications of cochlear implants, as well as the Risk Factors (RF) involved. METHODS: We analyzed the medical records of patients submitted to cochlear implants at public University from 2006 to July 2019, and list here the major and minor complications found, and their risk factors. RESULTS: There were 193 ears, 100 (51.3%) from females and 93 (48.2%) from males, with a mean age of 23.63 years. In 54 of them (28%), there were alterations seen in the Temporal Bone CT scan, and 44 (22.8%) in the brain MRI. There were 158 (81.9%) insertions performed; 127 (65.8%) of them through the round window. There were 78 complications: 19 (9.8%) major and 56 (29%) minor complications. Among the major complications, there were 3 (1.6%) Surgical Site infections (SS); 5 (2.6%) hematomas/seromas; 5 (2.6%) electrode extrusion; 5 (2.6%) device faults; 1 (0.5%) wrong path. Among the minor complications, there were 6 (3.1%) Acute Otitis Media (AOM); 9 (4.7%) SS infections; 4 (2.1%) facial paresis; 17 (8.8%) vertigos; 9 (4.7%) with tinnitus. The most important RF was age. Patients younger than 2.5 years had more major complications: SS infection (p = 0.018) and electrode extrusion (p = 0.017). There was a higher rate of vertigo in adults (p = 0.003), and it was more often associated with comorbidities (p = 0.008). The insertion route, the presence of changes in CT and MRI and the CI brand used did not impact the number of complications. CONCLUSION: Among the minor complications, those involving the vestibular system were the most common, especially in adults with comorbidities. Regarding major complications, there was an emphasis on SS infections, hematomas, seromas, electrode extrusion, especially in children under two years of age. There were implanted device faults (2.6%), with none of the brands evaluated standing out.


Assuntos
Implante Coclear , Complicações Pós-Operatórias , Humanos , Masculino , Feminino , Estudos Retrospectivos , Fatores de Risco , Adulto , Implante Coclear/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Adulto Jovem , Pessoa de Meia-Idade , Adolescente , Criança , Implantes Cocleares/efeitos adversos , Pré-Escolar , Idoso , Lactente , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética
4.
CoDAS ; 36(1): e20220177, 2024. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1528447

RESUMO

RESUMO Objetivo Desenvolver guia para elaboração de relatórios fonoaudiológicos de crianças implantadas para serem compartilhados entre fonoaudiólogos dos serviços de implante coclear (IC) e reabilitadores. Método O método Delphi foi utilizado para selecionar os itens relevantes e fundamentais que deveriam constar nas duas versões propostas para compor o guia: Guia 1 - Relatórios fonoaudiológicos fornecidos pelo serviço de IC aos reabilitadores, e Guia 2 - Relatórios fonoaudiológicos fornecidos pelos reabilitadores aos serviços de IC. Vinte e um fonoaudiólogos especialistas e com experiência na área de implante coclear e de reabilitação auditiva participaram da discussão e do julgamento dos itens durante as rodadas de seleção. Considerou-se consenso quando o item obteve a concordância igual ou superior a 80% entre os participantes, sendo selecionados para comporem os dois guias. Resultados Após as duas rodadas, 21 itens do Guia 1 obtiveram consenso entre os terapeutas, ou seja, mais de 80% deles concordaram que estes itens deveriam estar presentes no relatório enviado pelo serviço de IC. Para o Guia 2, 22 itens analisados pelos fonoaudiólogos atuantes em serviços de IC setor pós-operatório, foram selecionados na segunda rodada. Conclusão A partir da análise das duas rodadas, foi desenvolvido o "Guia para a elaboração de relatórios fonoaudiológicos: intersecção entre serviço de IC e reabilitadores". Este material pode ser aplicado na rotina de acompanhamento de crianças implantadas, padronizando as informações compartilhadas sobre o dispositivo eletrônico, resultados de avaliações, monitoramento dos resultados e processo terapêutico dessa população.


ABSTRACT Purpose To develop a guide for the preparation of speech-language reports of implanted children to be shared among speech-language pathologists of cochlear implant (CI) services and rehabilitation professionals. Methods The Delphi method was used to select the relevant and fundamental items that should be included in the two versions proposed for the guide: Guide 1 - Speech-language reports provided by the CI services to rehabilitators, and Guide 2 - Speech-language reports provided by the rehabilitators to CI services. Twenty-one speech therapists specialized and with experience in cochlear implants and auditory rehabilitation participated in the discussion and judgment of the items during the selection rounds. Consensus was considered when the item reached agreement equal to or greater than 80% among participants, being selected to compose the two guides. Results After the two rounds, 21 items from Guide 1 reached consensus among therapists, that is, more than 80% of them agreed that these items should be present in the report sent by the CI service. For Guide 2, 22 items analyzed by speech therapists working in CI services in the postoperative sector were selected in the second round. Conclusion Based on the analysis of the two rounds, the "Guide for the preparation of speech-language pathology reports: intersection between CI service and rehabilitators" was developed. This material can be applied in the follow-up of implanted children, standardizing the information shared about the electronic device, evaluation results, monitoring of results and therapeutic process of this population.

5.
Int. arch. otorhinolaryngol. (Impr.) ; 28(2): 301-306, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558017

RESUMO

Abstract Introduction Facial nerve stimulation (FNS) is a complication in cochlear implant (CI) when the electrical current escapes from the cochlea to the nearby facial nerve. Different management to reduce its effects are available, although changes might result in a less-than-ideal fitting for the CI user, eventually reducing speech perception. Objective To verify the etiologies that cause FNS, to identify strategies in managing FNS, and to evaluate speech recognition in patients who present FNS. Methods Retrospective study approved by the Ethical Board of the Institution. From the files of a CI group, patients who were identified with FNS either during surgery or at any time postoperatively were selected. Data collection included: CI manufacturer, electrode array type, age at implantation, etiology of hearing loss, FNS identification date, number of electrodes that generated FNS, FNS management actions, and speech recognition in quiet and in noise. Results Data were collected from 7 children and 25 adults. Etiologies that cause FNS were cochlear malformation, head trauma, meningitis, and otosclerosis; the main actions included decrease in the stimulation levels followed by the deactivation of electrodes. Average speech recognition in quiet before FNS was 86% and 80% after in patients who were able to accomplish the test. However, there was great variability, ranging from 0% in quiet to 90% of speech recognition in noise. Conclusion Etiologies that cause FNS are related to cochlear morphology alterations. Facial nerve stimulation can be solved using speech processor programming parameters; however, it is not possible to predict outcomes, since results depend on other variables.

6.
Int. arch. otorhinolaryngol. (Impr.) ; 28(2): 219-225, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558023

RESUMO

Abstract Introduction Cochlear implant (CI) activation usually takes place at ∼ 30 days postoperative (PO). In our service, CI surgery is performed with local anesthesia and sedation, so activation is possible with the patient's cooperation, immediately after the CI surgery, still in the operating room (OR). Objective The objective of the present study was to provide the patient with hearing experience with the CI and to assess auditory perception immediately after surgery while still in the OR, as well as to compare impedance telemetry (IT), neural response telemetry (NRT), and comfort (C) level at two moments: in the OR and at the definitive activation, ∼ 30 days PO. Methods Nine adult patients (12 ears) with acquired (postlingual) deafness were included. Auditory perception was evaluated through the Ling Six Sound Check, musical instruments, and clapping, presented in two different programming maps, elaborated using t-NRT, and comparing IT, NRT, and C level between the two moments. Results We observed that while still in the OR, the patient can already present auditory detection and recognition responses. The values of IT, NRT threshold (t-NRT), and C on both dates differed, with statistical significance. Conclusion We concluded that it is possible to provide the patient with an auditory experience with the CI immediately after surgery, and that the auditory experience and the values of electrode IT, NRT, and C vary significantly between the two moments.

7.
Audiol., Commun. res ; 29: e2778, 2024. tab, graf
Artigo em Português | LILACS | ID: biblio-1533839

RESUMO

RESUMO Objetivo Avaliar a contribuição da tecnologia de escuta assistida em usuários de implante coclear (IC) em situações de reverberação e ruído. Métodos Estudo transversal prospectivo aprovado pelo Comitê de Ética Institucional (CAAE 8 3031418.4.0000.0068). Foram selecionados adolescentes e adultos usuários de IC com surdez pré ou pós-lingual. Para usuários bilaterais, cada orelha foi avaliada separadamente. O reconhecimento de fala foi avaliado por meio de listas gravadas de palavras dissílabas apresentadas a 65 dBA a 0° azimute com e sem o Mini Microfone2 (Cochlear™) conectado ao processador de fala Nucleus®6. A reverberação da sala foi medida como 550 ms. Para avaliar a contribuição do dispositivo de escuta assistida (DEA) em ambiente reverberante, o reconhecimento de fala foi avaliado no silêncio. Para avaliar a contribuição do DEA em reverberação e ruído, o reconhecimento de fala foi apresentado a 0° azimute com o ruído proveniente de 8 alto-falantes dispostos simetricamente a 2 metros de distância do centro com ruído de múltiplos falantes usando relação sinal-ruído de +10dB. Para evitar viés de aprendizado ou fadiga, a ordem dos testes foi randomizada. A comparação das médias foi analisada pelo teste t para amostras pareadas, adotando-se nível de significância de p<0,005. Resultados Dezessete pacientes com idade média de 40 anos foram convidados e concordaram em participar, sendo 2 participantes bilaterais, totalizando 19 orelhas. Houve contribuição positiva significante do Mini Mic2 na reverberação e ruído+reverberação (p<0,001). Conclusão DEA foi capaz de melhorar o reconhecimento de fala de usuários de IC tanto em situações de reverberação quanto ruidosas.


ABSTRACT Purpose This study aimed to evaluate the contribution of assistive listening technology with wireless connectivity in cochlear implant (CI) users in reverberating and noise situations. Methods Prospective cross-sectional study approved by the Institutional Ethics Committee (CAAE 8 3031418.4.0000.0068). Adolescents and adults CI users with pre- or post-lingual deafness were selected. For bilateral users, each ear was assessed separately. Speech recognition was assessed using recorded lists of disyllabic words presented at 65 dBA at 0° azimuth with and without the Wireless Mini Microphone 2 (Cochlear™) connected to the Nucleus®6 speech processor. Room reverberation was measured as 550 ms. To assess the contribution of the assistive listening device (ALD) in a reverberating environment, speech recognition was assessed in quiet. To assess the contribution of the ALD in reverberation and noise, speech recognition was presented at 0° azimuth along with the noise coming from 8 loudspeakers symmetrically arranged 2 meters away from the center with multi-talker babble noise using signal to noise ratio of +10dB. To avoid learning bias or fatigue, the order of the tests was randomized. Comparison of means was analyzed by t test for paired samples, adopting significance level of p <0.005. Results Seventeen patients with a mean age of 40 years were invited and agreed to participate, with 2 bilateral participants, totaling 19 ears assessed. There was a significant positive contribution from the Mini Mic2 in reverberation, and noise+reverberation (p <0.001). Conclusion ALD was able to improve speech recognition of CI users in both reverberation and noisy situations.


Assuntos
Humanos , Masculino , Feminino , Adulto , Tecnologia Assistiva , Medição de Ruído , Implante Coclear , Surdez , Reconhecimento de Voz , Inteligibilidade da Fala , Estudos Transversais
8.
Int. arch. otorhinolaryngol. (Impr.) ; 27(3): 445-454, Jul.-Sept. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514246

RESUMO

Abstract Introduction Despite the developing technology of cochlear implants (CIs), implanted prelingual hearing-impaired children exhibit variable speech processing outcomes. When these children match in personal and implant-related criteria, the CI outcome variability could be related to higher-order cognitive impairment. Objectives To evaluate different domains of cognitive function in good versus poor CI performers using a multidisciplinary approach and to find the relationship between these functions and different levels of speech processing. Methods This observational, cross-sectional study used the word recognition score (WRS) test to categorize 40 children with CIs into 20 good (WRS/65%) and 20 poor performers (WRS < 65%). All participants were examined for speech processing at different levels (auditory processing and spoken language) and cognitive functioning using (1) verbal tests (verbal component of Stanford-Binet intelligence [SBIS], auditory memory, auditory vigilance, and P300); and (2) performance tasks (performance components of SBIS, and trail making test). Results The outcomes of speech processing at different functional levels and both domains of cognitive function were analyzed and correlated. Speech processing was impaired significantly in poor CI performers. This group also showed a significant cognitive function deficit, in which the verbal abilities were more affected (in 93.5%) than in the good performers (in 69.5%). Moreover, cognitive function revealed a significant correlation and predictive effect on the CI speech outcomes. Conclusion Cognitive function impairment represented an important factor that underlies the variable speech proficiency in cochlear-implanted children. A multidisciplinary evaluation of cognitive function would provide a comprehensive overview to improve training strategies.

9.
Int. arch. otorhinolaryngol. (Impr.) ; 27(3): 487-498, Jul.-Sept. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514249

RESUMO

Abstract Introduction Between 15% to 30% of individuals with bilateral prelingual sensorineural hearing loss present with associated disabilities. Cochlear implant (CI) is an alternative treatment that provides consistent access to environmental and speech sounds, which results in significant benefits regarding quality of life and auditory and language development. Objectives To study the auditory and communicative performance of individuals with CI and delayed neuropsychomotor development after a minimum of five years using the device. Methods A total of eight patients were included in the study. We collected the multidisciplinary clinical records of participants, as well as the answers for the questionnaires applied remotely, which included the Children with Cochlear Implants: Parental Perspectives (CCIPP), International Classification of Functioning, Disability and Health: Children and Youth Version (ICF-CY), and the Gross Motor Function Classification System (GMFCS). Results We found that throughout the years of CI use, the auditory threshold means improved significantly in all tested frequencies, as did the speech detection threshold and the language and hearing results. Regarding parental perception, parents evaluated aspects related to their children's social relations to be positive, and had worse perceptions regarding aspects related to their education. Conclusion We observed a progression in the participants' auditory and language skills throughout the years of CI use; even in the presence of other associated disabilities. Future multicentric studies with larger samples are needed to further the advancement of rehabilitation in patients with other associated disabilities.

10.
Int Arch Otorhinolaryngol ; 27(3): e487-e498, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37564470

RESUMO

Introduction Between 15% to 30% of individuals with bilateral prelingual sensorineural hearing loss present with associated disabilities. Cochlear implant (CI) is an alternative treatment that provides consistent access to environmental and speech sounds, which results in significant benefits regarding quality of life and auditory and language development. Objectives To study the auditory and communicative performance of individuals with CI and delayed neuropsychomotor development after a minimum of five years using the device. Methods A total of eight patients were included in the study. We collected the multidisciplinary clinical records of participants, as well as the answers for the questionnaires applied remotely, which included the Children with Cochlear Implants: Parental Perspectives (CCIPP), International Classification of Functioning, Disability and Health: Children and Youth Version (ICF-CY), and the Gross Motor Function Classification System (GMFCS). Results We found that throughout the years of CI use, the auditory threshold means improved significantly in all tested frequencies, as did the speech detection threshold and the language and hearing results. Regarding parental perception, parents evaluated aspects related to their children's social relations to be positive, and had worse perceptions regarding aspects related to their education. Conclusion We observed a progression in the participants' auditory and language skills throughout the years of CI use; even in the presence of other associated disabilities. Future multicentric studies with larger samples are needed to further the advancement of rehabilitation in patients with other associated disabilities.

SELEÇÃO DE REFERÊNCIAS