Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
1.
BMC Public Health ; 24(1): 2188, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39135026

RESUMO

BACKGROUND: Population surveys are crucial for public policy planning and provide valuable representative data. In the health sector studies to identify and assess the prevalence of Arterial Hypertension (AH), a chronic non-communicable disease (NCD), along with its associated risk factors have been conducted. OBJECTIVES: This study aims to assess the effectiveness of a population health survey in estimating the prevalence of arterial hypertension (AH) in the Sorocaba municipality between August 2021 and June 2023. METHODS: The analyzed performance indicator is the precision (design effect - deff) of AH prevalence in adults (≥ 18 years) and their exposure to primary risk factors. The total sample included 1,080 individuals from the urban area, deemed sufficient to estimate a deff of 1.5. This cluster-based study utilized census sectors as clusters, with data collected through household interviews, standardized questionnaires, and measurements of blood pressure and biometric parameters. The deff calculation formula used was weighted variance / raw variance. The Research Ethics Committee approved this study, with registration CAAE 30538520-1-0000-5373. RESULTS: The deff values ranged from 0.44 for chronic obstructive pulmonary disease to 1.63 for asthma, with a deff of 1.00 for AH prevalence. CONCLUSION: The study demonstrated good precision in its results, with high receptivity and cooperation from participants. The cost-effectiveness of the research deemed appropriate. The technique of selecting households within clusters (census sectors) based on detailed mapping and demographic data from the Instituto Brasileiro de Geografia e Estatística (IBGE) proved to be practical and efficient, suitable for replication in other municipalities and for studying other NCDs.


Assuntos
Inquéritos Epidemiológicos , Hipertensão , Humanos , Hipertensão/epidemiologia , Hipertensão/diagnóstico , Prevalência , Adulto , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Adolescente , Adulto Jovem , Fatores de Risco , Brasil/epidemiologia
2.
J Otolaryngol Head Neck Surg ; 53: 19160216241250353, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109789

RESUMO

BACKGROUND: Vestibular Activities and Participation Measure (VAP) subscales assess the effect of vestibular disorders on activity and participation. This study aimed to perform the cross-cultural adaptation and assess the validity, internal consistency, reliability, and measurement error of the Brazilian version of VAP subscales. METHODS: The cross-cultural adaptation followed the translation, synthesis, back-translation, review by a committee of experts, and pretesting phases. Structural validity was assessed using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA), while Spearman's correlation between VAP subscales and the Dizziness Handicap Inventory (DHI) was used to assess construct validity. Cronbach's alpha measured internal consistency. Intraclass correlation coefficient (ICC) assessed intra- and inter-rater reliability, and measurement error was calculated by using the standard error of measurement (SEM) and minimal detectable change (MDC). RESULTS: Additional information was included in the Brazilian version of the Vestibular Activities and Participation measure (VAP-BR) after approval by one of the developers of the instrument to improve the understanding among individuals. One factor was found in the EFA for each subscale with 50% explained variance. Regarding CFA, the subscales 1 (S1) and 2 (S2) presented, respectively, adequate model fit indices (ie, comparative fit index of 0.99 and 0.97, and standardized root mean square residual of 0.04 for both subscales), but a very low factor load in item 6 of S1 (0.08). Chronbach's alpha was 0.80 (S1) and 0.82 (S2). For intra-rater assessment, the S1 and S2 presented an ICC of 0.87 and 0.90, SEM of 0.01 and 1.16, and MDC of 0.39 and 0.46, respectively. When assessed by 2 different raters, SEM values were 1.03 and 1.53, and MDC values were 2.85 and 4.23 for S1 and S2, respectively; both subscales showed an ICC of 0.92. Correlations between DHI and VAP subscales presented coefficients above 0.57. CONCLUSION: The Brazilian version of VAP subscales presents good measurement properties and may assist health professionals in identifying activity limitations and participation restrictions in individuals with vestibular disorders.


Assuntos
Comparação Transcultural , Traduções , Doenças Vestibulares , Humanos , Brasil , Reprodutibilidade dos Testes , Doenças Vestibulares/diagnóstico , Doenças Vestibulares/fisiopatologia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Inquéritos e Questionários/normas , Psicometria , Avaliação da Deficiência , Análise Fatorial , Idoso
3.
Biomedica ; 44(Sp. 1): 160-170, 2024 05 31.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39079137

RESUMO

INTRODUCTION: Choric obstructive pulmonary disease (COPD) is the third mortality cause in the world, and the development of useful diagnostic tools is necessary to improve timely diagnostic rates in primary care settings. OBJECTIVE: To develop a web application displaying spirometric and clinical information - including respiratory symptoms and risk factors- to facilitate a COPD diagnosis. MATERIALS AND METHODS: In this cross-sectional study, an expert consensus was carried out with three specialists using the Delphi method to choose the relevant variables for COPD diagnosis. We developed a Python-based web application to diagnose COPD, displaying the clinical variables deemed relevant by the experts along the spirometric curve. RESULTS: Twenty-six clinical variables were included in the web application for the diagnosis of COPD. A fourth expert used the web application to classify a cohort of 695 patients who had undergone spirometry in a third-level centre and had answered at least one of five questionnaires for COPD screening. Out of the 695 subjects, 34% had COPD, according to the expert that diagnosed them using the web application. Only 42% of the patients in the COPD group had received a previous COPD diagnosis and 19% of the patients in the no COPD group had been misdiagnosed with the disease. CONCLUSION: We developed a web application that displays demographic and clinical information, as well as spirometric data, to facilitate the process of diagnosing COPD in primary care settings.


Introducción. La enfermedad pulmonar obstructiva crónica (EPOC) es la tercera causa de mortalidad en el mundo y es necesario el desarrollo de herramientas diagnósticas útiles para mejorar las tasas de diagnóstico oportuno en los entornos de atención primaria. Objetivo. Desarrollar una aplicación web que muestre la información clínica y de la espirometría ­incluyendo síntomas respiratorios y factores de riesgo­ para facilitar el diagnóstico de la EPOC. Materiales y métodos. En este estudio transversal se realizó un consenso de expertos con tres especialistas usando el método Delphi para elegir las variables relevantes para el diagnóstico de EPOC. Se desarrolló una aplicación web basada en Python que muestra la información clínica relevante según los expertos, junto con la curva y los datos de la espirometría para el diagnóstico de la EPOC. Resultados. Se incluyeron 26 variables clínicas para el diagnóstico de la EPOC. Un cuarto experto utilizó la aplicación web para clasificar una cohorte de 695 pacientes a los que se les había realizado una espirometría en un centro de tercer nivel y que habían contestado al menos uno de los cinco cuestionarios para la detección de la EPOC. De los 695 sujetos, el 34 % tenían EPOC según el experto que les diagnosticó usando la aplicación web. Sólo el 42 % de los pacientes del grupo con EPOC había recibido un diagnóstico previo de la enfermedad y el 19 % de los pacientes del grupo sin EPOC había sido diagnosticado erróneamente con la enfermedad. Conclusión. Se desarrolló una aplicación web que muestra información demográfica y clínica, así como datos espirométricos, para facilitar el proceso de diagnóstico de la EPOC en entornos de atención primaria.


Assuntos
Internet , Atenção Primária à Saúde , Doença Pulmonar Obstrutiva Crônica , Espirometria , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Humanos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Técnica Delphi
4.
Gac Sanit ; 38: 102372, 2024 Mar 08.
Artigo em Espanhol | MEDLINE | ID: mdl-38460207

RESUMO

OBJECTIVE: To evaluate the health information system (HIS) of Mexico according to the information reported to the Organization for Economic Co-operation and Development (OECD). The ultimate goal is to identify the improvements that should be considered. METHOD: Health indicators published by the OECD (2017 to 2021) are analyzed according to 11 thematic groups. Coverage (quantity and type of indicators reported by thematic group) and quality of information were assessed, according to OECD guidelines. RESULTS: Mexico reported annually 14 of 378 indicators (3.7%), and discontinuously 204. In no group were all indicators reported annually, except for the two on COVID-19. Three out of 88 were reported annually on use of services; and none on health status, quality of care and pharmaceutical market. Twelve indicators (5.5% of those reported by Mexico, 3.2% of the full OECD set) had optimal quality and annual reporting. 57.7% of the reported indicators had at least one quality defect. CONCLUSIONS: Within the framework of the standards set by the OECD, of which Mexico is a member, the Mexican HIS presents significant deficits in coverage and quality of information. These results should be considered to implement improvement initiatives.

5.
J Infect Public Health ; 17(4): 687-695, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38471259

RESUMO

BACKGROUND: Surveillance of healthcare-associated infections (HAIs) is an essential component of hospital infection prevention and control systems. We aimed to assess the quality of the data compiled by the Brazilian HAI Surveillance System from pediatric (PICUs) and neonatal intensive care units (NICUs), between 2012 and 2021. METHODS: Data Quality Review, including adherence, completeness, internal consistency, consistency over time, and consistency of population trend, were computed at both national and state levels based on quality metrics from World Health Organization Toolkit. Incidence rates (or incidence density) of ventilator-associated pneumonia (VAP) and central line-associated bloodstream infection (CLABSI) were obtained from the Brazilian National Nosocomial Infections Surveillance (NNIS) system. Data on sepsis-related mortality, spanning the period from 2012 to 2021, were extracted from the Brazilian National Health Service database (DATASUS). Additionally, correlations between sepsis-related mortality and incidence rates of VAP or CLABSI were calculated. RESULTS: Throughout the majority of the study period, adherence to VAP reporting remained below 75%, exhibiting a positive trend post-2016. Widespread outliers, as well as inconsistencies over time and in population trends, were evident across all 27 states. Only four states maintained consistent adherence levels above 75% for more than 8 years regarding HAI incidence rates. Notably, CLABSI in NICUs boasted the highest reporting adherence among all HAIs, with 148 periods out of 270 (54.8%) exhibiting reporting adherence surpassing 75%. Three states achieved commendable metrics for CLABSI in PICUs, while five states demonstrated favorable results for CLABSI in NICUs. CONCLUSIONS: While adherence to HAI report is improving among Brazilian states, an important room for improvement in the Brazilian NNIS exists. Additional efforts should be made by the Brazilian government to improve the reliability of HAI data, which could serve as valuable guidance for hospital infection prevention and control policies.


Assuntos
Infecções Relacionadas a Cateter , Infecção Hospitalar , Pneumonia Associada à Ventilação Mecânica , Sepse , Recém-Nascido , Humanos , Criança , Infecção Hospitalar/prevenção & controle , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/prevenção & controle , Confiabilidade dos Dados , Brasil/epidemiologia , Reprodutibilidade dos Testes , Medicina Estatal , Sepse/epidemiologia , Sepse/complicações , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Unidades de Terapia Intensiva
6.
J Stomatol Oral Maxillofac Surg ; : 101828, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38508394

RESUMO

OBJECTIVES: The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using computed tomography. STUDY DESIGN: This prospective in-vitro study used 30 polyurethane pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the dental implants as a control group, considered as the gold standard for postoperative comparison. RESULTS: The difference between these methods is close to zero and not statistically significant (p > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396. CONCLUSION: The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.

7.
Arch Orthop Trauma Surg ; 144(3): 1149-1159, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38231206

RESUMO

INTRODUCTION: Despite being the most used exam today, few studies have evaluated the accuracy of findings on non-contrast magnetic resonance imaging (MRI). The primary objective of the study was to evaluate the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of non-contrast MRI findings in frozen shoulder, isolated and in combination. The secondary objectives were to define the interobserver and intraobserver agreement of the assessments and the odds ratio for frozen shoulder because of the various findings of MRI. METHODS: A retrospective diagnostic accuracy study comparing non-contrast MRI findings between the frozen shoulder group and the control group. Sensitivity, specificity, positive and negative predictive value, accuracy, odds ratio, interobserver and intraobserver agreement were calculated for each finding and their possible associations. RESULTS: The hyperintensity on capsule in the axillary recess presented 84% sensitivity, 94% specificity, and 89% accuracy. The obliteration of the subcoracoid fat triangle in the rotator interval had sensitivity 34%, specificity 82% and accuracy 58%. For coracohumeral ligament thickness ≥ 2 mm had specificity 66%, 48% specificity and 57% accuracy. Capsule thickness in the axillary recess ≥ 4 mm resulted in 54% sensitivity, 82% specificity, and 68% accuracy. Regarding interobserver agreement, only the posteroinferior and posterosuperior quadrants showed moderate results, and all the others showed strong reliability. The odds ratio for hyperintensity in the axillary recess was 82.3 for frozen shoulder. The association of these findings increased specificity (95%). CONCLUSION: The accuracy of non-contrast magnetic resonance imaging is high for diagnosing frozen shoulder, especially when evaluating the hyperintensity of the axillary recess. The exam has high reliability and reproducibility. The presence of an association of signs increases the specificity of the test. LEVEL OF EVIDENCE: Level III, study of diagnostic test.


Assuntos
Bursite , Articulação do Ombro , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Articulação do Ombro/patologia , Imageamento por Ressonância Magnética/métodos , Bursite/diagnóstico por imagem , Sensibilidade e Especificidade
8.
Cad. Saúde Pública (Online) ; 40(1): e00070523, 2024. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1528221

RESUMO

O planejamento, o monitoramento e a avaliação das ações de alimentação e nutrição dependem de estimativas confiáveis realizadas a partir de dados antropométricos de qualidade adequada. O objetivo deste estudo foi analisar a qualidade de dados antropométricos de crianças menores de 5 anos no Sistema de Vigilância Alimentar e Nutricional (SISVAN) no período de 2008 a 2020. A amostra compreendeu 23.453.620 crianças menores de 5 anos. Inicialmente, avaliamos a distribuição de valores faltantes e de valores fora do espectro do equipamento e calculamos o índice de preferência de dígito para peso e altura. Os índices nutricionais altura para idade (A-I), peso para idade (P-I) e índice de massa corporal para idade (IMC-I) foram calculados com a utilização do padrão de crescimento da Organização Mundial da Saúde, de 2006. Em seguida, sinalizamos os valores biologicamente implausíveis (VBI) e calculamos o desvio padrão (DP) dos índices nutricionais. Para cada município, calculamos a média e o DP de A-I e P-I e plotamos os valores de DP em função da média. Em todas as Unidades Federativas, o índice de preferência de dígito alcançou valor mínimo de 80 para altura e 20 para peso. Para os três índices nutricionais, houve redução da frequência de VBI no período de 2008 a 2020. Mesmo após a exclusão dos VBI, identificamos elevada variabilidade para os três índices nutricionais. Os indicadores avaliados demonstraram baixa qualidade da mensuração principalmente nas regiões Norte e Nordeste. Nossos resultados indicam qualidade insuficiente dos dados antropométricos em crianças menores de 5 anos e reforçam a necessidade de investimento em ações para o aprimoramento da coleta e do registro das informações antropométricas.


The planning, monitoring, and evaluation of food and nutrition actions depend on reliable estimates based on adequate anthropometric data. The study aimed to analyze the quality of anthropometric data of children aged under 5 years in the Brazilian National Food and Nutrition Surveillance System (SISVAN) from 2008 to 2020. The sample comprised 23,453,620 children aged under 5 years. Initially, we evaluated the distribution of missing values and values outside the spectrum of the instrument, and calculated the digit preference index for weight and height. The nutritional indexes height for age (HAZ), weight for age (WAZ), and body mass index for age (BAZ) were calculated according to the World Health Organization 2006 child growth standards. Then, we identified the biologically implausible values (BIV) and calculated the standard deviation (SD) of the nutritional indexes. For each municipality, we calculated the mean and SD of HAZ and WAZ; and plotted the SD values as a function of the mean. In all Federative Units, the digit preference index reached a minimum value of 80 for height and 20 for weight. For the three nutritional indexes, there was a reduction in the frequency of BIV in the 2008-2020 period. Even after the exclusion of BIV, we identified high variability for the three nutritional indexes. The indicators evaluated showed low quality of measurement, especially in the North and Northeast regions. Our results indicate insufficient quality of anthropometric data in children aged under 5 years, and reinforce the need to invest in actions to improve the collection and recording of anthropometric information.


La planificación, monitoreo y evaluación de acciones de alimentación y nutrición dependen de estimaciones confiables realizadas a partir de datos antropométricos de calidad adecuada. El objetivo del estudio fue analizar la calidad de datos antropométricos de niños menores de 5 años en el Sistema de Vigilancia Alimentaria y Nutricional (SISVAN) entre los años 2008 y 2020. La muestra se compuso de 23.453.620 niños menores de 5 años. Al principio, evaluamos la distribución de valores faltantes y de valores fueras del espectro del equipo, y calculamos el índice de preferencia de dígito para peso y altura. Los índices nutricionales altura para edad (A-E), peso para edad (P-E) e índice de masa corporal para edad (IMC-E) se calcularon utilizando el patrón de crecimiento de la Organización Mundial de la Salud de 2006. Luego, indicamos los valores biológicamente inverosímiles (VBI) y calculamos la desviación estándar (DE) de los índices nutricionales. Para cada municipio, calculamos la media y la DE de A-E y P-E; y representamos los valores de DE en función de la media. En todas las Unidades Federativas, el índice de preferencia de dígito alcanzó el valor mínimo de 80 para altura y 20 para peso. Para los tres índices nutricionales, hubo una disminución de la frecuencia de VBI entre los años de 2008 y 2020. Incluso tras excluir los VBI, identificamos una alta variabilidad para los tres índices nutricionales. Los indicadores evaluados demostraron una baja calidad de medición, sobre todo en las regiones Norte y Nordeste. Nuestros resultados indican una calidad insuficiente de datos antropométricos en niños menores de 5 años y fortalecen la necesidad de inversión en acciones para mejorar la recolección y registro de las informaciones antropométricas.

9.
Physis (Rio J.) ; 34: e34013, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558682

RESUMO

Abstract Introduction The pregnant woman's card is one of the instruments used to evaluate prenatal care. It is an important source of data for epidemiological survey, being essential to ensure the flow of information and contribute to the continuity of care. Objective: Analyze studies that focused on the evaluation of the completeness of the pregnant woman's card. Methods A systematic review was carried out in the Scielo, Virtual Health Library, EMBASE, and Web of Science databases and the checklist based on the Preferred Reporting Items for Systematic Reviews (PRISMA) guideline was used. Results Forty-three studies were identified, resulting in seven analyzed. The studies showed methodological differences, especially regarding the fields of the pregnant woman's card selected for analysis, method of presentation and interpretation of results, ranging from relative frequency with different categories to classification by Romero & Cunha score. This divergence limited the comparison of findings. Even so, all studies observed poor completeness in important fields of the maternity card. Conclusion It is extremely important that professionals and managers value the full completion of the pregnant woman's card, favoring the assessment of care and decision-making during prenatal care.


Resumo Introdução O cartão da gestante é um dos instrumentos utilizados para avaliar o pré-natal. É importante fonte de dados para levantamento epidemiológico, sendo fundamental para garantir fluxo de informações e contribuir para a continuidade do cuidado. Objetivo: Analisar estudos que se detiveram na avaliação da completitude do cartão da gestante. Métodos Realizou-se revisão sistemática nas bases de dados Scielo, Biblioteca Virtual em Saúde, EMBASE e Web of Science e utilizou-se a checklist com base na diretriz Preferred Reporting Items for Systematic Reviews (PRISMA). Resultados Quarenta e três estudos foram identificados, resultando em sete analisados. Os estudos apresentaram diferença metodológica, sobretudo quanto aos campos do cartão da gestante selecionados para análise, método de apresentação e interpretação de resultados, variando da frequência relativa com diferentes categorias à classificação pelo score de Romero & Cunha. Essa divergência limitou a comparação dos achados. Ainda assim, todos os estudos observaram completitude ruim em campos importantes do cartão da gestante. Conclusão É extremamente importante que profissionais e gestores valorizem o preenchimento integral do cartão da gestante, favorecendo a avaliação da assistência e a tomada de decisão durante o pré-natal.

10.
Dental press j. orthod. (Impr.) ; 29(1): e2423217, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1550226

RESUMO

ABSTRACT Objective: This study evaluated the accuracy and precision of digital models acquisition using a home-built, low-cost scanning system based on the structured light method. Methods: a plaster model (PM) was scanned using the experimental device (SL) and a dental desktop scanner (DS). The teeth dimensions of PM and SL models were measured in triplicate, with a caliper and digitally, respectively. The agreement of the measurements of each model was evaluated using the intraclass correlation coefficient, and the validity between the different measurement techniques was assessed using the Bland-Altman analysis. The accuracy and precision of the models were qualitatively investigated using the mesh superposition of the SL and DS models. Results: A high intraclass correlation coefficient was observed in all models (PM=0.964; SL1=0.998; SL2=0.995; SL3=0.998), and there was no statistical difference between the measurements of the SL models (p>0.05). PM and SL model measurements were found to be in good agreement, with only 3.57% of the observed differences between the same measurement being located outside 95% limits of agreement according to Bland and Altman (0.43 and -0.40 mm). In the superimpositions of SL-SL and SL-DS models, areas of discrepancy greater than 0.5 mm were observed mainly in interproximal, occlusal, and cervical sites. Conclusion: These results indicate that the home-built SL scanning system did not possess sufficient accuracy and precision for many clinical applications. However, the consistency in preserving the dental proportions suggests that the equipment can be used for planning, storage, and simple clinical purposes.


RESUMO Objetivo: Este estudo avaliou a acurácia e a precisão da aquisição de modelos digitais utilizando um sistema de digitalização caseiro e de baixo custo baseado no método de luz estruturada. Material e Métodos: Para isso, um modelo de gesso (MG) foi digitalizado utilizando o dispositivo experimental (LE) e um scanner dental de mesa (SD). As dimensões dos dentes dos modelos MG e LE foram medidas em triplicata com um paquímetro e digitalmente, respectivamente. A concordância das medidas de cada modelo foi avaliada usando o coeficiente de correlação intraclasse, e a validade entre as diferentes técnicas de medição foi avaliada usando a análise de Bland-Altman. A acurácia e a precisão dos modelos foram investigadas qualitativamente usando a sobreposição de malhas dos modelos LE e SD. Resultados: Um alto coeficiente de correlação intraclasse foi observado em todos os modelos (MG=0,964; LE1=0,998; LE2=0,995; LE3=0,998) e não houve diferença estatística entre as medições dos modelos LE (p>0,05). As medições dos modelos MG e LE mostraram boa concordância, com apenas 3,57% das diferenças observadas entre as mesmas medições localizadas fora dos limites de concordância de 95% de acordo com a análise de Bland-Altman (0,43 e -0,40 mm). Nas sobreposições dos modelos LE-LE e LE-SD, foram observadas áreas de discrepância maiores que 0,5 mm principalmente nos sítios interproximais, oclusais e cervicais. Conclusões: Esses resultados indicam que o sistema de digitalização por luz estruturada caseiro não possui precisão e acurácia suficientes para muitas aplicações clínicas. No entanto, a consistência na preservação das proporções dentárias sugere que o equipamento pode ser usado para planejamento, armazenamento e propósitos clínicos simples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA