Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Prim Prev ; 41(3): 279-295, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32410066

RESUMO

In 2017, Puerto Rico sustained extensive damage from Hurricane Maria, increasing the risk of fires and carbon monoxide (CO) poisonings. Using a population-based, in-person survey of households with children less than 6 years old in Puerto Rico, we collected data in 2010 concerning the presence of smoke alarms and CO alarms in these households. We generated national estimates by extrapolating the number of households in each stratum using data from the 2010 Census. We determined which household characteristics predicted the presence of these alarms. Of 355 households analyzed, 31% had functional smoke alarms, or an estimated 109,773 households territory wide. The presence of smoke alarms was associated with living in multifamily housing and no child in the household receiving government medical insurance. Public housing or publicly subsidized housing, as compared to owner-occupied housing and unsubsidized rental housing, was associated with having a functional smoke alarm in households with children aged less than 6 years. Based on only six houses having CO alarms, we estimated only 7685 (2%) households had CO alarms. The low prevalence of functional smoke or CO alarms 7 years before Hurricane Maria is unfortunate and should be remedied by ensuring that such alarms are widely installed in current rebuilding activities.


Assuntos
Monóxido de Carbono/análise , Características da Família , Incêndios , Fumaça/análise , Intoxicação por Monóxido de Carbono/prevenção & controle , Pré-Escolar , Estudos Transversais , Tempestades Ciclônicas , Feminino , Incêndios/prevenção & controle , Humanos , Equipamentos de Proteção , Habitação Popular , Porto Rico , Medição de Risco
2.
Rev. bras. oftalmol ; 79(1): 56-58, Jan.-Feb. 2020. graf
Artigo em Português | LILACS | ID: biblio-1092651

RESUMO

Resumo Fogo em campo cirúrgico durante cirurgia palpebral é uma complicação intra-operatória que é dramática tanto para o paciente quanto para a equipe médica. Relatamos um caso de acidente cirúrgico durante cirurgia palpebral onde o paciente sofreu queimadura de supercílio. Houve interação entre o oxigênio usado para sedação (máscara aberta) e uma fonte de ignição representada pelo cautério monopolar. Embora o paciente tenha apresentado boa evolução clínica com recuperação total da lesão cutânea, este caso é um alerta para se evitar tais tipo de ocorrência. Ressaltamos neste trabalho quais as condições implicadas e o modo de prevenção.


Abstract Fire in the surgical field during eyelid surgery is an intra-operative complication that is dramatic for both the patient and the medical staff. It's being reported a case of surgical accident during eyelid surgery where the patient suffered a brow burn. There was interaction between the oxygen used for sedation (open mask) and a source of ignition represented by monopolar cautery. Although the patient presented good clinical evolution with complete recovery of the cutaneous lesion, this case is an alert to avoid such type of occurrence. This work highlights the conditions involved and the way of prevention.


Assuntos
Humanos , Masculino , Idoso , Salas Cirúrgicas , Eletrocoagulação/efeitos adversos , Eletrocirurgia/efeitos adversos , Pálpebras/cirurgia , Segurança do Paciente , Incêndios/prevenção & controle , Blefaroptose/cirurgia , Queimaduras/etiologia , Fatores de Risco , Blefaroplastia/métodos , Eletricidade/efeitos adversos , Eletrocoagulação/instrumentação , Eletrocirurgia/instrumentação , Complicações Intraoperatórias
3.
Acta amaz. ; 48(4): 358-367, Oct.-Dec. 2018. graf, tab, mapas
Artigo em Inglês | VETINDEX | ID: vti-736288

RESUMO

Wildland fires can be responsible for negative impacts on the environment, causing damage to the fauna and flora and increasing the release of greenhouse gases. In the state of Amazonas, wildland fires represent a risk for biodiversity conservation, since more than 95% of the state is covered by Amazon rainforest, one of the largest and most biodiverse tropical forests of the world. This study aimed to analyze the spatiotemporal variation of fire occurrence from 2003 to 2016 in the state of Amazonas, based on data from the AQUA satellite processed by the Brazilian National Institute for Space Research, using the Collection 5 detection algorithm. The correlation between fire incidence versus anthropogenic and climatic variables was also tested. A significant uptrend was observed in the number of hot spots recorded over the years. About 83% of the wildland fires occurred during the months of August, September and October. The variables that correlated significantly with the number of hot spots for each municipality were deforested area, pasture area, agricultural area, municipality area and mean annual rainfall. The municipality with the highest number of hot spots detected was Lábrea, while Careiro da Várzea presented the highest incidence per km2. The southern and eastern regions of the state were the areas most affected by fire during the analyzed period. The results from this study emphasize the need for implementation of public policies aimed to reduce deforestation and wildland fires in the state, thus ensuring the conservation of the Amazon rainforest and its biodiversity.(AU)


As queimadas controladas e incêndios florestais podem ser responsáveis por impactos negativos ao meio ambiente, ocasionando danos à fauna e flora e contribuindo para a liberação de gases na atmosfera responsáveis pelo efeito estufa. O fogo no Amazonas representa um grande risco para a preservação da biodiversidade, já que mais de 95% da área do estado é recoberta por floresta amazônica, uma das maiores florestas tropicais do mundo. Este trabalho teve por objetivo analisar a variação espaço-temporal dos focos de calor registrados de 2003 a 2016 no estado do Amazonas, com base em dados obtidos através do satélite AQUA e processados pelo INPE, utilizando o algoritmo de detecção Collection 5. Os dados de focos de calor foram correlacionados com variáveis antropogênicas e climáticas. Foi observada uma tendência significativa de alta nos registros de focos de calor ao longo dos anos. Cerca de 83% das detecções ocorreram nos meses de Agosto, Setembro e Outubro. As variáveis área desmatada, área de pastagem, área agrícola, área do município e precipitação média anual apresentaram correlação significativa com o número de focos de calor para cada município. O município com maior registro de focos de calor foi Lábrea, enquanto Careiro da Várzea apresentou a maior incidência por área. Os resultados obtidos ressaltam a necessidade de implementação de políticas públicas que visem a redução do desmatamento e dos incêndios florestais no estado, garantindo a preservação da floresta amazônica e sua biodiversidade.(AU)


Assuntos
Incêndios Florestais , Tecnologia de Sensoriamento Remoto/métodos , Análise Espaço-Temporal , Brasil
4.
Acta amaz ; 48(4): 358-367, Oct.-Dec. 2018. graf, tab, map
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1455372

RESUMO

Wildland fires can be responsible for negative impacts on the environment, causing damage to the fauna and flora and increasing the release of greenhouse gases. In the state of Amazonas, wildland fires represent a risk for biodiversity conservation, since more than 95% of the state is covered by Amazon rainforest, one of the largest and most biodiverse tropical forests of the world. This study aimed to analyze the spatiotemporal variation of fire occurrence from 2003 to 2016 in the state of Amazonas, based on data from the AQUA satellite processed by the Brazilian National Institute for Space Research, using the Collection 5 detection algorithm. The correlation between fire incidence versus anthropogenic and climatic variables was also tested. A significant uptrend was observed in the number of hot spots recorded over the years. About 83% of the wildland fires occurred during the months of August, September and October. The variables that correlated significantly with the number of hot spots for each municipality were deforested area, pasture area, agricultural area, municipality area and mean annual rainfall. The municipality with the highest number of hot spots detected was Lábrea, while Careiro da Várzea presented the highest incidence per km2. The southern and eastern regions of the state were the areas most affected by fire during the analyzed period. The results from this study emphasize the need for implementation of public policies aimed to reduce deforestation and wildland fires in the state, thus ensuring the conservation of the Amazon rainforest and its biodiversity.


As queimadas controladas e incêndios florestais podem ser responsáveis por impactos negativos ao meio ambiente, ocasionando danos à fauna e flora e contribuindo para a liberação de gases na atmosfera responsáveis pelo efeito estufa. O fogo no Amazonas representa um grande risco para a preservação da biodiversidade, já que mais de 95% da área do estado é recoberta por floresta amazônica, uma das maiores florestas tropicais do mundo. Este trabalho teve por objetivo analisar a variação espaço-temporal dos focos de calor registrados de 2003 a 2016 no estado do Amazonas, com base em dados obtidos através do satélite AQUA e processados pelo INPE, utilizando o algoritmo de detecção Collection 5. Os dados de focos de calor foram correlacionados com variáveis antropogênicas e climáticas. Foi observada uma tendência significativa de alta nos registros de focos de calor ao longo dos anos. Cerca de 83% das detecções ocorreram nos meses de Agosto, Setembro e Outubro. As variáveis área desmatada, área de pastagem, área agrícola, área do município e precipitação média anual apresentaram correlação significativa com o número de focos de calor para cada município. O município com maior registro de focos de calor foi Lábrea, enquanto Careiro da Várzea apresentou a maior incidência por área. Os resultados obtidos ressaltam a necessidade de implementação de políticas públicas que visem a redução do desmatamento e dos incêndios florestais no estado, garantindo a preservação da floresta amazônica e sua biodiversidade.


Assuntos
Análise Espaço-Temporal , Incêndios Florestais , Tecnologia de Sensoriamento Remoto/métodos , Brasil
5.
Burns ; 43(2): 343-349, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27663506

RESUMO

PURPOSE: A major fire occurred on January 27, 2013, at 02:30 at Kiss nightclub in the city of Santa Maria, State of Rio Grande do Sul, in Southern Brazil. In this retrospective report, we aimed to describe the nightclub fire event, its immediate consequences, and evaluated its impact on legislation. Our objective was to disseminate the lessons we learned from this large-scale nightclub fire disaster. METHODS: We conducted a literature review in PubMed and Lilacs database from 2013 to 2015 related to the nightclub Kiss, Santa Maria, fire, burns, and similar events worldwide over the past 15 years. We searched in the general press and online media information sites, and seeking legislation about this topic at the federal level in Brazil. We reported on the legislation changes that resulted from this nightclub fire. RESULTS: Current federal legislation on fire prevention and the scope of public safety, including night clubs and discos, states is the duty of the state and everyone's responsibility, pursuant to Article 144 of the Federal Constitution of Brazil. Thus, the federal union, individual states and municipalities have the power to legislate on fire prevention, and especially to ensure the security of the population. A state law called "Law Kiss", was passed in 2014, establishing standards on safety, prevention and protection against fire in buildings and areas of fire risk in the state of Rio Grande do Sul. On a national level, a law of prevention and fire fighting in Brazil was also drafted after the Santa Maria disaster (Law project no. 4923, 2013). Currently, this bill is still awaiting sanction before it can take effect. CONCLUSION: As we push for enactment of the national law of prevention and fire fighting in Brazil, we will continue emphasizing fire prevention, fire protection, fire fighting, means of escape and proper management. All similar events in this and other countries remind us that similar tragedies may occur anywhere, and that the analysis of facts, previous mistakes, during and after the incident are crucial to our understanding, and will help us lessen the chance of future occurrences.


Assuntos
Queimaduras/prevenção & controle , Desastres/prevenção & controle , Incêndios/prevenção & controle , Incidentes com Feridos em Massa/prevenção & controle , Política Pública , Segurança/legislação & jurisprudência , Brasil/epidemiologia , Queimaduras/epidemiologia , Intoxicação por Monóxido de Carbono/epidemiologia , Aglomeração , Incêndios/legislação & jurisprudência , Humanos , Hidrolases/intoxicação , Incidentes com Feridos em Massa/estatística & dados numéricos , Estudos Retrospectivos , Lesão por Inalação de Fumaça/epidemiologia
6.
Rev. bras. anestesiol ; 62(3): 435-438, maio-jun. 2012.
Artigo em Português | LILACS | ID: lil-626519

RESUMO

JUSTIFICATIVA E OBJETIVOS: A existência de um ambiente rico em oxigênio, material combustível em abundância e a utilização de aparelhos capazes de fornecerem ignição transformam a sala cirúrgica em um ambiente de risco para a ocorrência de incêndios. Apesar de rara, trata-se de uma complicação potencialmente grave e na maioria das vezes evitável. Relatamos um caso de incêndio no campo cirúrgico durante uma cirurgia de blefaroplastia em que foi suplementado oxigênio por meio de cateter nasal. RELATO DO CASO: Paciente de 52 anos, sexo feminino, sem comorbidades, admitida para realização de blefaroplastia bilateral. Após monitorização e venóclise, procedeu-se à sedação endovenosa com oferta de oxigênio suplementar por meio de cateter tipo óculos, com fluxo de 4 L.min-1, seguida de anestesia local das pálpebras. Durante o ato cirúrgico, a utilização do bisturi elétrico ocasionou combustão dos campos cirúrgicos e queimaduras na face da paciente. CONCLUSÕES: O anestesiologista desempenha papel fundamental na prevenção de incêndio na sala cirúrgica, reconhecendo possíveis fontes de ignição e administrando de forma racional o oxigênio, principalmente com sistemas abertos. O primeiro passo para a prevenção deve ser a lembrança constante da possibilidade de incêndio.


BACKGROUND AND OBJECTIVES: There are several factors in operating rooms that increase the risk of fire. Besides being an oxygen-enriched environment, it contains combustible materials and equipment with available ignition sources. Although fires in operating rooms are a relatively rare event, the consequences are potentially serious and mostly avoidable. We present a case report of a fire occurring in the surgical drape during a blepharoplasty in which oxygen was supplemented by nasal catheter. CASE REPORT: Female patient, 52-years old, without comorbidities, admitted to hospital for a bilateral blepharoplasty. After monitoring and venoclysis, the patient underwent intravenous sedation and additional oxygen given via spectacle-type catheter at a flow rate of 4 L.min-1, followed by local anesthesia in the eyelids. During surgery, the use of electric scalpel provoked combustion in the surgical drapes and burns on the patient's face. CONCLUSIONS: Anesthesiologists play an important role preventing fire in operating rooms, as they can recognize possible ignition sources and rationally administer the oxygen, especially in open systems. The first step toward prevention is to be constantly aware of potential fire.


JUSTIFICATIVA Y OBJETIVOS: La existencia de un ambiente rico en oxígeno, material combustible en abundancia, y la utilización de aparatos capaces de realizar la ignición, transforma el quirófano en un ambiente de riesgo para el conato de incendios. A pesar de ser una complicación rara, es potencialmente grave y en la mayoría de los casos se puede evitar. Relatamos aquí un caso de incendio en el ambiente quirúrgico durante una cirugía de blefaroplastia en que fue suministrado oxígeno por medio de un catéter nasal. RELATO DEL CASO: Paciente de 52 años, del sexo femenino, sin comorbilidades, admitido para la realización de blefaroplastia bilateral. Posteriormente a la monitorización y a la venoclisis, se procedió a la sedación endovenosa con oferta de oxígeno suplementario por medio de un catéter tipo gafas con flujo de 4 L.min-1, seguida de anestesia local en los párpados. Durante la operación, la utilización del bisturí eléctrico creó una combustión de los campos quirúrgicos produciendo quemaduras en la cara de la paciente. CONCLUSIONES: El anestesiólogo desempeña un rol fundamental en la prevención del incendio en el quirófano, reconociendo posibles fuentes de ignición y administrando de forma racional el oxígeno, principalmente con sistemas abiertos. El primer paso para su prevención es estar siempre alertas sobre la posibilidad de que se pueda producir un incendio.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Centro Cirúrgico Hospitalar/organização & administração , Sistemas de Combate a Incêndio/normas , Incêndios/prevenção & controle , Blefaroplastia/instrumentação , Anestesia Local/instrumentação
7.
Cienc. Trab ; 12(38): 423-432, oct.-dic. 2010. graf, tab
Artigo em Espanhol | LILACS | ID: lil-583463

RESUMO

Este trabajo tiene como objetivo estudiar el nivel de seguridad contra incendios de los edificios de altura en Chile, en base a un análisis descriptivo de datos que permita establecer de modo representativo la realidad existente en ellos para, posteriormente, entregar recomendaciones de mejoramiento. Para este propósito, se ha realizado una recopilación de datos de evaluaciones a edificios de altura que han sido elaborados desde el año 1991 hasta el año 2009. Los resultados se han agrupado en función del tipo de construcción del edificio y sus partes, los equipos e instalaciones de servicio, los equipos e instalaciones de extinción y la seguridad de vida. Los resultados obtenidos permiten comprender los niveles de seguridad de vida que presentan estas edificaciones, visualizar los puntos más débiles en seguridad contra incendios y proponer cambios a nuestra legislación vigente. Además, se hace necesario mejorar las condiciones constructivas de los edificios antiguos que, en su mayoría, no cuentan con una zona vertical de seguridad que permita a los usuarios evacuar en forma segura hacia la salida en caso de presentarse una emergencia. Finalmente, se entrega en este trabajo una serie de comentarios sobre los análisis realizados.


This work aims to study the fire safety level of high-rise buildings in Chile with a descriptive data analysis that enables us to determine representatively the actual situation and then provide improvement recommendations. In order to achieve this purpose, a data collection from fire risk assessments of high rise buildings between 1991 and 2009 has been conducted. Results have been classified according to type of construction of the building and its parts, fire extinguishing equipment and system, and safety of life. Results obtained provide an understanding of the safety of life levels in these buildings, a visualization of the weakest spots in fire safety, and allow us to suggest changes in legislation in force. Moreover, it is necessary to improve construction conditions of old buildings,which mostly have no vertical safety area that enable users to evacuate in a safe manner in case of emergency. Finally, a series of comments about analysis is also available.


Assuntos
Edifícios , Saída de Emergência , Sistemas de Combate a Incêndio , Prevenção e Proteção contra Incêndios , Medidas de Segurança , Segurança/normas , Chile
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA