Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Int Endod J ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984709

RESUMO

AIM: To compare the effects of Cervical Access Cavity (CervAC) and Traditional Access Cavity (TradAC) on root canal preparation, root canal filling, and fracture resistance in mandibular incisors. METHODOLOGY: Twenty recently extracted and intact mandibular incisors were initially scanned using a micro-CT device. The specimens were anatomically matched to create two groups (n = 10). A wedge-shaped non-carious cervical lesion (NCCL) was created on the buccal aspect of all teeth using a double-faced segmented diamond disc. In group 1, a TradAC was prepared, whilst in group 2, access was created through the simulated NCCL using a round diamond bur 1012. After root canal preparation with Rotate instruments sizes 15/0.04, 20/0.04, and 25/0.04, the teeth were scanned again and evaluated for root canal volume and surface area, static voxels, volume of removed dental tissue, and dentine thickness. After that, the root canals were filled using the single-cone technique, teeth were restored with composite resin, and subsequently rescanned to calculate the volume of filling materials and voids. Then, the restored teeth were subjected to fracture resistance tests using a universal testing machine. Statistical comparisons between groups were performed with the Mann-Whitney test or the Student's t-test, with a statistical significance level of 5%. RESULTS: Statistical comparisons indicated no significant differences between groups in terms of root canal volume, surface area, static voxels, removed root dentine, root canal filling volume, percentage of voids, or fracture resistance load (p > .05). Conversely, teeth prepared with TradAC showed a significantly higher percentage of dental tissue removed from the crown (p = .001) and a greater volume of filling material remnants in the pulp chamber (p < .001) compared to the CervAC group. A significantly lower percentage reduction in dentine thickness was observed only on the mesial aspect of root at Level 1 in TradAC group (p = .008). CONCLUSIONS: CervAC can be considered a viable alternative approach in the presence of NCCL in mandibular incisors.

2.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1564656

RESUMO

La preparación de la cavidad de acceso es el primer paso y un requisito esencial, para la instrumentación y obturación de los conductos radiculares durante el tratamiento endodóntico. El objetivo del presente estudio fue comparar la resistencia a la fractura in vitro de premolares con cavidad de acceso tradicional (CAT), cavidad de acceso conservador (CAC) y cavidad de acceso ultraconservador (CAU). Esta fue una investigación transversal, prospectiva y experimental pura. Se realizó con 40 segundos premolares superiores, divididos en 4 grupos. Todas las muestras fueron desinfectadas y almacenadas en recipientes con suero fisiológico al 0,9 %. Al primer grupo se designó como el control, al segundo grupo CAT, al tercer grupo CAC y al cuarto grupo CAU. Se realizaron todos los accesos endodónticos con una pieza de mano de alta velocidad con refrigeración respetando el protocolo de cada uno de los diseños, posterior a ello se realizó el tratamiento endodóntico y restauración de los especímenes. Una vez preparadas todas las muestras, estas fueron sometidas a una prueba de fatiga en una máquina de ensayo universal y los resultados se registraron en Newtons. La prueba estadística usada fue ANOVA con un nivel de significancia de 5 %. Las CAT obtuvieron el menor valor de resistencia a la fractura en comparación con el grupo control. Sin embargo, no se observaron diferencias estadísticamente significativas entre los grupos CAT, CAC Y CAU. Entre los grupos CAC y CAU, no se encontraron diferencias estadísticamente significativas en comparación con el grupo control.


The preparation of the access cavity is the first step and an essential requirement for the instrumentation and obturation of the root canals during endodontic treatment. The objective of the present study was to compare the in vitro fracture resistance of premolars with traditional access cavity (CAT), conservative access cavity (CAC) and ultraconservative access cavity (CAU). This was a cross-sectional, prospective and pure experimental research. It was carried out with 40 upper second premolars, divided into 4 groups. All samples were disinfected and stored in containers with 0.9 % physiological saline. The first group was designated as the control, the second group CAT, the third group CAC and the fourth group CAU. All endodontic accesses were carried out with a high-speed handpiece with refrigeration, respecting the protocol of each of the designs, after which the endodontic treatment and restoration of the specimens was carried out. Once all the samples were prepared, they were subjected to a fatigue test in a universal testing machine and the results were recorded in Newtons. The statistical test used was ANOVA with a significance level of 5 %. The CAT obtained the lowest fracture resistance value, presenting statistically significant differences with the control group. However, no statistically significant differences were observed between the CAT, CAC, and CAU groups. Furthermore, between the CAC and CAU groups, no statistically significant differences were found compared to the control group.

3.
Aust Endod J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747371

RESUMO

This study assessed the mechanical properties of the Only One File Blue and the Reciproc Blue instruments. A total of 80 new 25 mm reciprocating NiTi instruments (25/.08v) were evaluated for their mechanical performance (n = 40 per group). Cyclic fatigue resistance, torsional fatigue, flexural resistance and buckling resistance tests were conducted. Statistical analysis was employed with a significance level set at 5%. The results indicated no statistically significant differences in resistance to cyclic fatigue neither in the fragment length between the instruments (p > 0.05). However, the Reciproc Blue instrument exhibited greater torque to fracture and a larger rotation angle than the Only One File Blue instrument (p < 0.05). The Only One File Blue instrument demonstrated higher flexibility but lower resistance to buckling compared to the Reciproc Blue instrument (p < 0.05). In conclusion, the tested instruments exhibit differences in mechanical properties, with the Reciproc Blue instrument generally presenting greater advantages than the Only One File Blue.

4.
Sci Rep ; 14(1): 8075, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38580685

RESUMO

During the preparation of fixed prosthesis (including individual bridges and crowns) it is important to select the materials that have the best features and properties to predict a successful clinical treatment. The objective of this study was to determine if the chemical and structural characteristics could cause to increase the fracture resistance, we used four bis-acryl resins Luxatemp, Protemp, Structur and Telio. Three-points bending by Flexural test were performed in ten bars and they were carried out to compare with Anova test. In addition, the bis-acryl resins were analyzed by scanning electron microscopy, to analyze microstructure and morphology and the molecular structure were performed by Infrared Spectroscopy through Attenuated Total Reflectance. A higher flexural strength was found in Luxatemp and Structur with, no significant differences between this study groups. Regarding Protemp and Telio, these study groups showed a lower flexural strength when were compared with Luxatemp and Structur. These results corroborate SEM and ATR analysis because Luxatemp sample showed a regular size particle on the surface and chemically presents a long cross-linkage polymer chain. The presence of CO3, SiO2 and N-H groups as a fillers particle interacting with OH groups cause a higher flexural strength compared with another groups.

5.
J Esthet Restor Dent ; 36(9): 1326-1336, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38665052

RESUMO

OBJECTIVES: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling. MATERIALS AND METHODS: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB). Specimens underwent mechanical cycling (5 × 106 cycles; 150 N) evaluating fatigue resistance (number of failures) and those that failed were subsequently subjected to fractographic analyses (stereomicroscope and scanning electron microscope) to evaluate failure location and area, and maximum fracture load was also measured. RESULTS: The failure-related survival rate (100%) and maximum fracture resistance of the MZrB were significantly higher than those of MC and Zr (50%; p < 0.05). There were no significant differences in the failure rate and fracture resistance when a CoCr base abutment was used or not in the translucent monolithic Zr groups (p > 0.05;MZrB vs. MZr). Failure location, with MC crowns' fractures, noted at the screw area (p = 0.043), while all-ceramic crowns were mostly in the cuspid and to failure area, the Zr group had the largest mean (15.55 ± 9.17 mm2) among the groups, significant difference only when compared with MC (1.62 ± 0.81 mm2) (p = 0.025). CONCLUSIONS: Translucent monolithic zirconia crowns exhibited significantly higher fatigue and fracture resistance compared with conventional MC and bilayered crowns. CLINICAL SIGNIFICANCE: The appropriate choice of material and manufacturing technique is crucial for predicting the higher clinical performance of single crowns. Enhanced mechanical resistance in terms of fatigue and fracture resistance can be achieved by replacing MC and bilayered restorations with computer-aided design and computer-aided manufacturing monolithic zirconia.


Assuntos
Coroas , Análise do Estresse Dentário , Zircônio , Zircônio/química , Cerâmica/química , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Prótese Dentária Fixada por Implante , Teste de Materiais , Humanos
6.
Int J Paediatr Dent ; 34(1): 3-10, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37038703

RESUMO

BACKGROUND: The literature is scanty regarding the effect of radiation therapy (RT) on the mechanical properties of immature permanent teeth. AIM: To evaluate the effect of RT on the fracture resistance of simulated immature teeth submitted to different types of root reinforcement. DESIGN: Sixty-four human teeth simulating the Cvek stage 3 of root development were distributed into eight groups (n = 8), according to exposure or not to RT (70 Gy) and the root reinforcement method: Group NR (control)-no reinforcement/no RT; Group NR + RT (control)-no reinforcement/RT; Group PO-tricalcium silicate-based cement (TS) apical plug/canal obturation/no RT; Group PO + RT-TS apical plug/canal obturation/RT; Group TS-canal filling with TS/no RT; Group TS + RT-canal filling with TS/RT; Group FP-TS apical plug/fibreglass post/no RT; and Group FP + RT-TS apical plug/fibreglass post/RT. Fracture resistance was determined using a universal testing machine (0.5 mm/min). RESULTS: In the intergroup comparison, nonirradiated teeth had higher fracture resistance (p < .05). Groups FP and FP + RT had higher fracture resistance (p < .001). CONCLUSION: Radiotherapy affected the fracture resistance of simulated immature teeth. Reinforcement with fibreglass posts increased the fracture resistance, regardless of the radiation.


Assuntos
Materiais Restauradores do Canal Radicular , Fraturas dos Dentes , Humanos , Compostos de Cálcio , Raiz Dentária , Silicatos
7.
Nanomaterials (Basel) ; 13(23)2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38063727

RESUMO

This research article explores the effect of grain boundary (GB) misorientation on the mechanical behavior of aluminum (Al) bicrystals by means of molecular dynamics (MD) simulations. The effect of GB misorientation on the mechanical properties, fracture resistance, and crack propagation are evaluated under monotonic and cyclic load conditions. The J-integral and the crack tip opening displacement (CTOD) are assessed to establish the effect of the GB misorientation angle on the fracture resistance. The simulations reveal that the misorientation angle plays a significant role in the mechanical response of Al bicrystals. The results also evidence a gradual change in the mechanical behavior from brittle to ductile as the misorientation angle is increased.

8.
Materials (Basel) ; 16(18)2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37763547

RESUMO

The development of digital technologies has allowed for the fabrication of new materials; however, it makes it difficult to choose the best methods to obtain occlusal splints with optimal properties, so it is essential to evaluate the effectiveness of these materials. The aim of the study is to compare the fracture resistance of occlusal splints made of different materials after thermo-mechanical aging. METHODS: A total of 32 samples were made from 4 materials (two 3D printed polymeric materials, a PMMA disc for CAD/CAM, and a conventional heat-cured acrylic resin); subsequently, the fracture test was performed using the load compression mode applied occlusally on the splint surface. STATISTICAL ANALYSIS: Four statistical tests were used (Shapiro-Wilk, Levene's test, ANOVA, and Tukey's HSD test). RESULTS: The following study showed that there are differences in fracture strength among the four materials investigated, where the highest strength was observed in the milled splint, with a mean of 3051.2 N (newton) compared to the strength of the flexible splint with 1943.4 N, the printed splint with 1489.9 N, and the conventional acrylic splint with 1303.9 N. CONCLUSIONS: The milled splints were the most resistant to fracture. Of the printed splints, the splint made with flexural rigid resin withstood the applied forces in acceptable ranges, so its clinical indication may be viable. Although the results of this research indicated differences in the mechanical properties between the CAD/CAM and conventional fabrication methods, the selection may also be influenced by processing time and cost, since with a CAD/CAM system there is a significant reduction in the production time of the splint material.

9.
Polymers (Basel) ; 15(18)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37765627

RESUMO

The aim of this study was to evaluate and compare the fracture resistance of a single-unit fixed prosthesis, using a CAD/CAM PMMA material and two printed materials (3DPPa and 3DPPb). A typodont with a specific preparation for a full crown was used; a digital impression was made with a state-of-the-art scanner (PrimeScanTM, Dentsply-SironaTM, New York, NY, USA), and a full coverage restoration was designed using a biogeneric design proposal by means of specific software (InLAB 22.1, Dentsply-Sirona, NY, USA). Sixty crowns were prepared, divided into three groups according to the material: 3DPPa (n = 20), 3DPPb (n = 20), both 3D-printed from the .STL file with a resolution of 50 µm, and PMMA (n = 20) milled-derived, which were subjected to a thermocycling process. A universal testing machine (Universal/Tensile Testing Machine, Autograph AGS-X Series) with integrated software (TRAPEZIUM LITE X) equipped with a 20 kN load cell was used to determine the fracture resistance. Significant differences were found by Kruskal-Wallis test and multiple comparisons (p < 0.05) in fracture resistance between materials. The fracture resistance for the PMMA material was higher, and the standard deviation was lower (x = 1427.9; sd = 36.9 N) compared to the 3DPPa (x = 1231; sd = 380.1 N) and 3DPPb (x = 1029.9; sd = 166.46 N) prints. The restorations from the milled-derived group showed higher average fracture resistance than the provisional restorations obtained from the printed groups. However, the results demonstrated that all three materials analyzed in single-unit restorations are capable of withstanding the average masticatory forces.

10.
Braz. dent. j ; 34(4): 62-71, July-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520328

RESUMO

Abstract This study aimed to evaluate the effect of antioxidant solutions on fracture strength and bonding performance in non-vital and bleached (38% hydrogen peroxide) teeth. One hundred and eighty dentin specimens were obtained, 60 for each test: fracture strength, hybrid layer thickness, and bond strength. The groups (n=10) were randomly composed according to post-bleaching protocol: REST - restoration, without bleaching; BL - bleaching + restoration; SA - bleaching, 10% sodium ascorbate solution, and restoration; AT - bleaching, 10% α-tocopherol solution, and restoration; CRAN - bleaching, 5% cranberry solution, and restoration; CAP - bleaching, 0.0025% capsaicin solution, and restoration. Data were analyzed with ANOVA, Kruskal-Wallis, Dunn, and Qui-Square tests (α=0.05). The highest fracture strength values were observed in REST (1508.96 ±148.15 N), without significant difference for the bleached groups (p>0.05), regardless of the antioxidant use. The hybrid layer thickness in the group that was not subjected to bleaching (REST) was significantly higher than in any other group. The bond strength in the bleached and antioxidants-treated groups (SA, AT, CRAN, CAP) has no differences with the bleached group without antioxidants (BL). Adhesive failures were predominant in the groups that did not receive the antioxidant application. In conclusion, the evaluated antioxidants did not show an effect on the fracture strength, hybrid layer thickness, or bond strength of dentin bleached after endodontic treatment. The application of 10% sodium ascorbate, 10% alpha-tocopherol, 5% cranberry, or 0.0025% capsaicin solutions is not an effective step and should not be considered for the restorative protocols after non-vital bleaching.


Resumo Este estudo teve como objetivo avaliar o efeito de soluções antioxidantes na resistência à fratura e resistência de união em dentes tratados endodonticamente e clareados (38% de peróxido de hidrogênio). Cento e oitenta espécimes de dentina foram obtidos, 60 para cada teste: resistência à fratura, espessura da camada híbrida e resistência de união. Os grupos (n=10) foram compostos aleatoriamente de acordo com o protocolo pós-clareamento: REST - restauração, sem clareamento; BL - clareamento + restauração; SA - clareamento, solução de ascorbato de sódio a 10% e restauração; AT - clareamento, solução de α-tocoferol a 10% e restauração; CRAN - clareamento, solução de cranberry a 5% e restauração; CAP - clareamento, solução de capsaicina 0,0025% e restauração. Os dados foram analisados ​​com os testes ANOVA, Kruskal-Wallis, Dunn e Qui-Quadrado (α=0,05). Os maiores valores de resistência à fratura foram observados em REST (1508,96 ±148,15 N), sem diferença significativa para os grupos clareados (p>0,05), independente do uso de antioxidantes. A espessura da camada híbrida no grupo que não foi submetido ao clareamento (REST) foi significativamente maior do que em qualquer outro grupo. A resistência de união nos grupos clareado e tratado com antioxidantes (SA, AT, CRAN, CAP) não apresentou diferenças com o grupo branqueado sem antioxidantes (BL). As falhas adesivas foram predominantes nos grupos que não receberam a aplicação do antioxidante. Em conclusão, os antioxidantes avaliados não mostraram efeito sobre a resistência à fratura, espessura da camada híbrida ou resistência de união à dentina clareada após tratamento endodôntico. A aplicação de soluções de ascorbato de sódio 10%, alfa-tocoferol 10%, cranberry 5% ou capsaicina 0,0025% não é uma etapa eficaz e não deve ser considerada para os protocolos restauradores após clareamento não vital.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA