1.
Int J Retina Vitreous ; 10(1): 33, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605358

RESUMO

BACKGROUND: Describe complications and clinical outcomes of heavy silicone oil (HSO) Oxane HD® use as an alternative to overcome the challenges of performing vitrectomy to treat tractional and rhegmatogenous retinal detachments with proliferative vitreoretinopathy (PVR). METHODS: A retrospective, observational study was performed on patients from one center from August 2014 to Aug 2023. It was included patients who underwent surgery using HSO Oxane HD® to treat rhegmatogenous retinal detachment with PVR or mixed tractional and rhegmatogenous diabetic retinal detachment. Severely ill patients who could not attend to follow up were excluded. The primary outcome was successful retinal attachment at first postoperative month. A descriptive analysis was performed. RESULTS: Among the 31 patients, 29 (93.5%) underwent surgeries due to rhegmatogenous retinal detachment and two (6.5%) for diabetic retinal detachment. The primary anatomic success was achieved in 27 (87.1%) patients. At the final visit, 17 (56.6%) had vision better than 20/400 (range, 20/30 to light perception). The vision was stable or improved in 22 (76.8%) patients at the end of follow-up. Nineteen (61.3%) patients required hypotensive eye drops after HSO use and twelve (38.7%) still required hypotensive eye drops at the final follow-up; three (9.7%) patients required additional glaucoma surgeries. CONCLUSIONS: HSO is safe and useful for complex retinal detachments cases specially with inferior tears and PVR. Ocular hypertension is frequent and usually clinically controlled with hypotensive eyedrops. Close postoperatively follow-up is advised due to the ocular complications, particularly elevated intraocular pressure and emulsification.

2.
Int J Retina Vitreous ; 9(1): 64, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872580

RESUMO

The main drawback for the use of heavy silicone oil (HSO) Oxane HD is the difficulties it presents during removal. It differs from conventional silicone oil removal because it progressively concentrates in the posterior pole during the removal because of its heavier than water density. We describe a technique to facilitate proper HSO Oxane HD removal and minimize residual posterior bubbles and intraoperative complications. We describe our pearls for removing HSO to obtain the optimal results. A concern associated with HSO is the difficulty it presents when it is removed. However, this can be overcome by appropriate modification of surgical techniques during removal to limit intraoperative complications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA