Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 259(6): 1579-1586, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33417091

RESUMO

PURPOSE: To assess the cumulative risk of progression in glaucomatous eyes in the severe stage of disease. METHODS: This was a retrospective observational study. Patients that had severe damage in at least one eye, as defined by three criteria including a mean deviation of ≤ - 20 dB, were included. Glaucoma progression was defined as a loss of ≥ 2 dB in mean deviation confirmed in three consecutive visual field tests, or a persistent loss of two or more lines of vision-not attributable to non-glaucomatous causes-in three consecutive follow-up examinations. Kaplan-Meier survival analysis was used to assess the cumulative incidence of progression of the first eye to reach endpoint in cases where both eyes were eligible. RESULTS: A total of 143 eyes from 119 patients, were studied over a mean period of 4.9 ± 2.9 years. Baseline mean deviation was - 25.3 ± 3.6 dB. Twenty-three eyes of 22 patients reached the progression endpoint: 14 eyes by visual field criteria and 9 by visual acuity criteria. The cumulative 5-year risk of progression estimated by Kaplan-Meier analysis was 14.6% (95% confidence interval: 6.1-22.2%). CONCLUSIONS: In severe glaucoma patients, we found a cumulative incidence of progression of 2.9% per year during the first 5 years of follow-up. Similar incidences have been reported in other studies of glaucoma at different stages of severity.


Assuntos
Glaucoma , Campos Visuais , Progressão da Doença , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Humanos , Pressão Intraocular , Estudos Retrospectivos , Transtornos da Visão/diagnóstico , Transtornos da Visão/epidemiologia , Testes de Campo Visual
2.
Clin Ophthalmol ; 14: 4201-4207, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33299296

RESUMO

OBJECTIVE: To compare global retinal sensitivity thresholds obtained through the Easyfield perimeter (EF) and Humphrey visual field analyzer (HFA). DESIGN: Observational cross-sectional study. PARTICIPANTS: Glaucomatous patients and glaucoma suspects enrolled between October 2018 and April 2019. MATERIALS AND METHODS: All participants underwent EF (SPARK Precision) and HFA perimetry (SITA-Standard). After inclusion, demographic and ocular data were collected, including measurements of retinal nerve fiber layer (RNFL) thickness obtained from spectral-domain optical coherence tomography (SD-OCT). Global indices (mean deviation, MD; pattern standard deviation, PSD) values were compared between perimeters, and their correlation and agreement were evaluated. We used regression analysis to investigate structure-functional correlations between SD-OCT measurements and MD index of each perimeter. RESULTS: We investigated 111 eyes from 69 patients. Mean MD (mean difference=1.49dB) and PSD values (mean difference=0.42dB) from the HFA were significantly larger than those from the EF perimeter (p<0.001). There were significant linear correlations between EF-MD and HFA-MD (r=0.56), and EF-PSD and HFA-PSD (r=0.38; p<0.001). We found significant non-linear associations between average RNFL thickness and MD values derived from both EF (R2=0.41) and HFA (R2=0.17) perimeters (p≤0.012). A difference <2dB between EF-MD and HFA-MD was found in 53% of the eyes, while 71% of them had a difference <1dB between EF-PSD and HFA-PSD. CONCLUSION: While we found a moderate correlation and a small mean sensitivity difference between test results, EF's correlation with structural measurements was at least comparable to that of the HFA. Our findings suggest that although these tests should not be used interchangeably, EF SPARK Precision could be used as an alternative for functional assessment in eyes with mild glaucoma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA