Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 37(8S): S803-S806, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34998907

RESUMO

BACKGROUND: Component positioning in total hip arthroplasty (THA) may be improved with utilization of intraoperative imaging. The purpose of this study is to determine if intraoperative imaging during THA is cost-effective. METHODS: A break-even analysis was used as a model for cost-effectiveness, which incorporates cost of imaging (including direct charges and the additional time required for imaging), rate of revision surgery, and cost of revision surgery, yielding a final revision rate that needs to be achieved with use of intraoperative imaging in order for its use to be cost-effective. Absolute risk reduction (ARR) is determined by the difference between the initial revision rate and final revision rate. RESULTS: At an anticipated institutional cost of $120 and requiring 4 additional minutes, intraoperative fluoroscopy would be cost-effective if the baseline rate of revision due to component mispositioning (0.62%) is reduced to 0.46%. Intraoperative flat plate radiographs ($127) are cost-effective at an ARR of 0.16%. Cost-effectiveness is achieved with lower ARR in the setting of lower imaging costs ($15, ARR 0.02%), and higher ARR with higher imaging costs ($225, ARR 0.29%). ARR for cost-effectiveness is independent of baseline revision rate, but varies with the cost of revision procedures. CONCLUSION: At current revision rates for component malpositioning, only 1 revision among 400 THAs needs to be prevented for the utilization of fluoroscopy (or 1 in 385 THAs with flat plate imaging), to achieve cost-effectiveness.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Análise Custo-Benefício , Fluoroscopia , Humanos , Radiografia , Reoperação
2.
J Thorac Cardiovasc Surg ; 157(5): 2061-2069, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31288365

RESUMO

BACKGROUND: Complete pulmonary metastasectomy for sarcoma metastases provides patients an opportunity for long-term survival and possible cure. Intraoperative localization of preoperatively identified metastases and identification of occult lesions can be challenging. In this trial, we evaluated the efficacy of near-infrared (NIR) intraoperative imaging using second window indocyanine green during metastasectomy to identify known metastases and to detect occult nodules. METHODS: Thirty patients with pulmonary nodules suspicious for sarcoma metastases were enrolled in an open-label, feasibility study (NCT02280954). All patients received intravenous indocyanine green (5 mg/kg) 24 hours before metastasectomy. Patients 1 through 10 (cohort 1) underwent metastasectomy via thoracotomy to assess fluorescence patterns of nodules detected by traditional methods (preoperative imaging and intraoperative visualization/bimanual palpation). After confirming reliability within cohort 1, patients 11 through 30 (cohort 2) underwent video-assisted thoracic surgery metastasectomy with NIR imaging. RESULTS: In cohort 1, 14 out of 16 preoperatively identified pulmonary metastases (87.5%) displayed tumor fluorescence. Nonfluorescent metastases were deeper than fluorescent metastases (2.1 cm vs 1.3 cm; P = .03). Five out of 5 metastases identified during thoracotomy displayed fluorescence. NIR imaging identified 3 additional occult lesions in this cohort. In cohort 2, 33 out of 37 known pulmonary metastases (89.1%) displayed fluorescence. Nonfluorescent tumors were deeper than 2.0 cm (P = .007). NIR imaging identified 24 additional occult lesions. Of 24 occult lesions, 21 (87.5%) were confirmed metastases and the remaining 3 nodules were lymphoid aggregates. CONCLUSIONS: NIR intraoperative imaging with indocyanine green (5 mg/kg and 24 hours before surgery) localizes known sarcoma pulmonary metastases and identifies otherwise occult lesions. This approach may be a useful intraoperative adjunct to improve metastasectomy.


Assuntos
Neoplasias Pulmonares/cirurgia , Metastasectomia/métodos , Nódulos Pulmonares Múltiplos/cirurgia , Imagem Óptica/métodos , Pneumonectomia , Sarcoma/cirurgia , Nódulo Pulmonar Solitário/cirurgia , Espectroscopia de Luz Próxima ao Infravermelho , Cirurgia Torácica Vídeoassistida , Toracotomia , Adulto , Idoso , Estudos de Viabilidade , Feminino , Corantes Fluorescentes/administração & dosagem , Humanos , Verde de Indocianina/administração & dosagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Masculino , Metastasectomia/efeitos adversos , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/secundário , Pneumonectomia/efeitos adversos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sarcoma/diagnóstico por imagem , Sarcoma/secundário , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/secundário , Cirurgia Torácica Vídeoassistida/efeitos adversos , Toracotomia/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Carga Tumoral , Adulto Jovem
3.
Phys Med ; 58: 114-120, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30824142

RESUMO

PURPOSE: Radio-guided surgery with ß- decays is a novel technique under investigation. One of the main advantages is its capability to detect small (⩽0.1 ml) samples after injecting the patient with low activity of radiopharmaceutical. This paper presents an experimental method to quantify this feature based on ex-vivo tests on specimens from meningioma patients. METHODS: Patients were enrolled on the basis of the standard uptake value (SUV) and the tumour-to-non-tumour activity ratio (TNR) resulted from 68Ga-DOTATOC PET exams. After injecting the patients with 93-167 MBq of 90Y-DOTATOC, 26 samples excised during surgery were analyzed with a ß- probe. The radioactivity expected on the neoplastic specimens was estimated according to the SUV found in the PET scan and the correlation with the measured counts was studied. The doses to surgeon and medical personnel were also evaluated. RESULTS: Even injecting as low as 1.4 MBq/kg of radiotracer, tumour residuals of 0.1 ml can be detected. A negligible dose to the medical personnel was confirmed. CONCLUSIONS: Radio-guided surgery with ß- decays is a feasible technique with a low radiation dose for both personnel and patient, in particular if the patient is injected with the minimum required activity. A correlation greater than 80% was observed between the measured counts and the expected activity for the lesion samples based on the individual SUV and the TNR. This makes identifiable the minimum injectable radiotracer activity for cases where 90Y is the utilized radionuclide.


Assuntos
Partículas beta , Tomografia por Emissão de Pósitrons , Cirurgia Assistida por Computador/métodos , Radioisótopos de Ítrio/administração & dosagem , Humanos , Injeções , Meningioma/diagnóstico por imagem , Meningioma/cirurgia , Exposição Ocupacional/análise , Octreotida/administração & dosagem , Octreotida/análogos & derivados , Doses de Radiação
4.
Oral Maxillofac Surg ; 20(1): 79-83, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26546376

RESUMO

PURPOSE: Isolated zygomatic arch fractures (IZAFs) are habitually reduced at a distance, via a temporal approach. Open reductions are not recommended due to the associated morbidity and complications. However, performing closed reductions makes it difficult to determine whether it was done satisfactorily. This study aims to determine whether the acquisition of intraoperative images with a C-arm to evaluate IZAF reductions is a useful technique in treating such fractures. METHODS: Our hypothesis is that acquiring intraoperative images with a C-arm reduces the need for a second surgery. Between 2009 and 2012, 50 patients who were diagnosed with IZAF requiring surgery were randomly distributed into two groups: 25 patients were in the experimental group, where fracture reduction was performed and immediately corroborated intraoperatively for an adequate result using a C-arm, and 25 patients were assigned to a control group where the fracture reduction was controlled with post-surgery imaging. RESULTS: The results did not reveal significant differences between both groups (p = 0.5). Nevertheless, the experimental group had the advantage of being able to immediately reduce the fracture again if the result was unsatisfactory. CONCLUSIONS: Despite the fact that the results are not statistically significant (p = 0.5), the authors recommend undertaking an intraoperative imaging analysis in areas where we are not certain of the reduction.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Fixação de Fratura/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Cirurgia Assistida por Computador/instrumentação , Fraturas Zigomáticas/cirurgia , Adolescente , Adulto , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto Jovem , Fraturas Zigomáticas/diagnóstico por imagem
5.
J Thorac Cardiovasc Surg ; 150(1): 28-35.e1, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26126457

RESUMO

BACKGROUND: More than 80,000 people undergo resection of a pulmonary tumor each year, and the only method to determine if the tumor is malignant is histologic analysis. We propose that a targeted molecular contrast agent could bind lung adenocarcinomas, which could be identified using real-time optical imaging at the time of surgery. METHODS: Fifty patients with a biopsy-proven lung adenocarcinoma were enrolled. Before surgery, patients were systemically administered 0.1 mg/kg of a fluorescent folate receptor alpha (FRα)-targeted molecular contrast agent by intravenous infusion. During surgery, tumors were imaged in situ and ex vivo, after the lung parenchyma was dissected to directly expose the tumor to the imaging system. RESULTS: Tumors ranged from 0.3 to 7.5 cm (mean: 2.6 cm), and 46 of 50 (92%) lung adenocarcinomas were fluorescent. No false uptake occurred, and in 2 cases, intraoperative imaging revealed tumor metastases (3 mm and 6 mm) that were not recognized preoperatively. Four adenocarcinomas were not fluorescent, and immunohistochemistry showed that these adenocarcinomas did not express FRα. Tumor fluorescence was independent of nodule size, uptake of 2-deoxy-2-((18)F)fluoro-D-glucose, histology, and tumor differentiation. Molecular imaging could identify only 7 of the 50 adenocarcinomas in situ in the patient without bisection. The most important predictor of the success of molecular imaging in locating the tumor in situ was the distance of the nodule from the pleural surface. CONCLUSIONS: Intraoperative molecular imaging with a targeted contrast agent can identify lung adenocarcinomas, and this technology is currently useful in patients with subpleural tumors, irrespective of size. With further refinements, this tool may prove useful in locating adenocarcinomas that are deeper in the lung parenchyma, in lymph nodes, and at pleural and resection margins.


Assuntos
Adenocarcinoma/patologia , Adenocarcinoma/cirurgia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Imagem Molecular , Monitorização Intraoperatória , Pneumonectomia , Adenocarcinoma de Pulmão , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoresceína-5-Isotiocianato , Corantes Fluorescentes , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
6.
Technol Cancer Res Treat ; 14(2): 213-20, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24354756

RESUMO

Fluorescence guided surgery (FGS) is a developing field of surgical and oncologic research. Practically, FGS has shown useful applications in urologic surgery, benign biliary surgery, colorectal cancer liver metastasis resection, and ovarian cancer debulking. Most notably in in cancer surgery, FGS allows for the clear delineation of cancerous tissue from benign tissue. FGS requires the utilization of a fluorescent contrast agent and an intraoperative fluorescence imaging device (IFID). Currently available IFIDs are expensive, unable to work with multiple fluorophores, and can be cumbersome. This study aims to describe the development and utility of a small, cost-efficient, and interchangeable IFID made from commercially available components. Extensive research was done to design and construct a light-weight, portable, and cost-effective IFID. We researched the capabilities, size, and cost of several camera types and eventually decided on a near-infrared (NIR) charged couple device (CCD) camera for its overall profile. The small portable interchangeable imager of fluorescence (SPIIF) is a "scout" IFID system for FGS. The main components of the SPIIF are a NIR CCD camera with an articulating light filter. These components and a LED light source with an attached heat sink are mounted on a small metal platform. The system is connected to a laptop by a USB 2.0 cable. Pixielink © software on the laptop runs the system by controlling exposure time, gain, and image capture. After developing the system, we evaluated its utility as an IFID. The system weighs less than two pounds and can cover a large area. Due to its small size, it is easily made sterile by covering it with any sterile plastic sheet. To determine the system's ability to detect fluorescent signal, we used the SPIIF to detect indocyanine green under ex and in-vivo conditions and fluorescein under ex-vivo conditions. We found the SPIIF was able to detect both ICG and fluorescein under different depths of a semi-opaque colloid. Second, we found that a concentration as low as 0.5 g/ml of indocyanine green dissolved in plasma was detectable. Lastly, in a murine and human cancer model, the SPIIF was able to detect indocyanine green signal within tumors and generate a signal-to-background ratio (SBR) of 3.75. This study shows that a low-cost IFID can be made from commercially available parts. Second, this IFID is capable of in and ex-vivo detection of multiple fluorophores without sacrificing its small size or favorable ergonomics.


Assuntos
Neoplasias Ósseas/cirurgia , Carcinoma Pulmonar de Lewis/cirurgia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Imagem Óptica/instrumentação , Osteossarcoma/cirurgia , Cirurgia Assistida por Computador/instrumentação , Animais , Carcinoma Pulmonar de Lewis/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Linhagem Celular Tumoral , Feminino , Fluoresceína , Corantes Fluorescentes , Humanos , Verde de Indocianina , Masculino , Camundongos Endogâmicos C57BL , Pessoa de Meia-Idade , Transplante de Neoplasias , Osteossarcoma/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA