Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 524
Filtrar
1.
Int J Mol Sci ; 25(13)2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-39000425

RESUMO

This study investigated the impact of adding hydroxyapatite nanoparticles to implant surfaces treated with zirconia blasting and acid etching (ZiHa), focusing on structural changes and bone healing parameters in low-density bone sites. The topographical characterization of titanium discs with a ZiHa surface and a commercially modified zirconia-blasted and acid-etched surface (Zi) was performed using scanning electron microscopy, profilometry, and surface-free energy. For the in vivo assessment, 22 female rats were ovariectomized and kept for 90 days, after which one implant from each group was randomly placed in each tibial metaphysis of the animals. Histological and immunohistochemical analyses were performed at 14 and 28 days postoperatively (decalcified lab processing), reverse torque testing was performed at 28 days, and histometry from calcified lab processing was performed at 60 days The group ZiHa promoted changes in surface morphology, forming evenly distributed pores. For bone healing, ZiHa showed a greater reverse torque, newly formed bone area, and bone/implant contact values compared to group Zi (p < 0.05; t-test). Qualitative histological and immunohistochemical analyses showed higher features of bone maturation for ZiHa on days 14 and 28. This preclinical study demonstrated that adding hydroxyapatite to zirconia-blasted and acid-etched surfaces enhanced peri-implant bone healing in ovariectomized rats. These findings support the potential for improving osseointegration of dental implants, especially in patients with compromised bone metabolism.


Assuntos
Durapatita , Nanopartículas , Osseointegração , Propriedades de Superfície , Zircônio , Zircônio/química , Animais , Durapatita/química , Durapatita/farmacologia , Feminino , Ratos , Nanopartículas/química , Osseointegração/efeitos dos fármacos , Implantes Dentários , Titânio/química , Tíbia/efeitos dos fármacos , Tíbia/cirurgia , Condicionamento Ácido do Dente
2.
Biology (Basel) ; 13(7)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-39056666

RESUMO

This study evaluated the bone incorporation process of a screw-shaped internal fixation device made of poly (L-lactide-co-D, L-lactide) (PLDLLA). Thirty-two male Wistar rats received 32 fixation devices (2 mm × 6 mm) randomly assigned to either the right or left tibia and one implant in each animal. After 7, 14, 28, and 42 days, the rats were euthanized and the specimens were subjected to microtomographic computed tomography (microCT) and histomorphometric analyses to evaluate bone interface contact (BIC%) and new bone formation (NBF%) in cortical and cancellous bone areas. The animals euthanized on days 28 and 42 were treated with calcein and alizarin red, and confocal LASER microscopy was performed to determine the mineral apposition rate (MAR). Micro-CT revealed a higher percentage of bone volume (p < 0.006), trabecular separation (p < 0.001), and BIC in the cortical (p < 0.001) and cancellous (p = 0.003) areas at 28 and 42 days than at 7 and 14 days. The cortical NBF at 42 days was greater than that at 7 and 14 days (p = 0.022). No statistically significant differences were observed in cancellous NBF or MAR at 28 and 42 days. Based on these results, it can be seen that the PLDLLA internal fixation device is biocompatible and allows new bone formation around the screw thread.

3.
Biology (Basel) ; 13(7)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39056725

RESUMO

(1) Objective: The aim of this study was to assess the biological behavior of bone tissue on a machined surface (MS) and modifications made by a laser beam (LS) and by a laser beam incorporated with hydroxyapatite (HA) using a biomimetic method without thermic treatment (LHS). (2) Methods: Scanning electron microscopy coupled with energy-dispersive X-ray spectrometry (SEM/EDX) was performed before and after installation in the rabbit tibiae. A total of 20 Albinus rabbits randomly received 30 implants of 3.75 × 10 mm in the right and left tibias, with two implants on each surface in each tibia. In the animals belonging to the 4-week euthanasia period group, intramuscular application of the fluorochromes calcein and alizarin was performed. In implants placed mesially in the tibiofemoral joint, biomechanical analysis was performed by means of a removal torque (N/cm). The tibias with the implants located distally to the joint were submitted for analysis by confocal laser microscopy (mineral apposition rate) and for histometric analysis by bone contact implant (%BIC) and newly formed bone area (%NBA). (3) Results: The SEM showed differences between the surfaces. The biomechanical analysis revealed significant differences in removal torque values between the MSs and LHSs over a 2-week period. Over a 4-week period, both the LSs and LHSs demonstrated removal torque values statistically higher than the MSs. BIC of the LHS implants were statistically superior to MS at the 2-week period and LHS and LS surfaces were statistically superior to MS at the 4-week period. Statistical analysis of the NBA of the implants showed difference between the LHS and MS in the period of 2 weeks. (4) Conclusions: The modifications of the LSs and LHSs provided important physicochemical modifications that favored the deposition of bone tissue on the surface of the implants.

4.
Clin Oral Investig ; 28(7): 380, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38886209

RESUMO

OBJECTIVE: To describe the clinical and radiographic performance and survival rate of a new two-piece ceramic implant system after at least 12 months of follow-up. MATERIALS AND METHODS: Sixty-five implants were placed and followed up for at least 12 months (12.3 ± 1.5), in 50 patients. The implants were installed both in fresh extraction sockets and in healed sites and received provisional restoration when the clinical insertion torque was greater than 35Ncm. The primary results describe the survival rate of these implants. Clinical performance was evaluated through the evaluation of the Pink Esthetic Score (PES) and the degree of satisfaction of the patients. Bone loss was measured through radiographic measurements of the marginal bone loss in the mesial (MBLM) and distal (MBLD) sites. RESULTS: The survival rate was 98.5%. The average MBLM was 0.24 mm (± 0.53) and the MBLD was 0.27 mm (± 0.57). A statistical difference was observed only when comparing immediate implants with delayed ones (MBLM - p = 0.046 and MBLD - p = 0.028) and when they received immediate provisionalization or not (MBLM - p = 0.009 and MBLD - p = 0.040). The PES before the intervention (T0) was 13.4 (± 0.8) and the PES at T2 (12-month follow-up) was 12.9 (± 1.5) (p = 1.14). CONCLUSION: The new two-piece ceramic implant used in the present study showed predictable and reliable results, similar to those found with titanium implants after one year of follow-up. CLINICAL RELEVANCE: These implants can be used as an alternative to titanium implants in terms of the marginal bone loss and the degree of patient satisfaction.


Assuntos
Cerâmica , Planejamento de Prótese Dentária , Humanos , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Cerâmica/química , Resultado do Tratamento , Adulto , Satisfação do Paciente , Idoso , Estética Dentária , Perda do Osso Alveolar/diagnóstico por imagem , Alvéolo Dental/cirurgia , Alvéolo Dental/diagnóstico por imagem , Falha de Restauração Dentária , Implantes Dentários
5.
Oral Maxillofac Surg ; 28(3): 1161-1168, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38480619

RESUMO

PURPOSE: To evaluate the survival rates of dental implants with a hybrid macrostructure and the surface biomimetically coated with nanohydroxyapatite, placed in horizontally atrophic maxillae previously submitted to the guided bone regeneration (GBR) procedure, associated with the use of a deproteinized bovine bone graft (DBB). METHODS: Twenty-five patients who received 196 implants were involved in this study. First, these patients were submitted to GBR procedures and maxillary sinus lift, where DBB was used as the grafting material. The dental implants were placed after a minimum period of 6 months of the grafting procedures. The patients were followed up every six months and clinical/radiographic examinations were performed to assess the implants, using the following indicators as a reference: (1) Absence of mobility; (2) Absence of pain. Data about the age, surgery time, smoking status, implant size, and time between the grafting procedure and implant placement were correlated with implant failures. RESULTS: Twelve implants failed, generating a survival rate of 94.23%. None of the variables analysed correlated with the implant failures. CONCLUSION: Implants with a hybrid macrostructure and surface biomimetically coated with nanohydroxyapatite present good survival rates in horizontally atrophic maxillae grafted with DBB.


Assuntos
Implantes Dentários , Maxila , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Maxila/cirurgia , Idoso , Animais , Falha de Restauração Dentária , Adulto , Transplante Ósseo/métodos , Durapatita , Bovinos , Levantamento do Assoalho do Seio Maxilar/métodos , Substitutos Ósseos , Perda do Osso Alveolar/cirurgia , Perda do Osso Alveolar/diagnóstico por imagem , Xenoenxertos/transplante , Implantação Dentária Endóssea/métodos , Análise de Sobrevida
6.
J Biomed Mater Res B Appl Biomater ; 112(2): e35380, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38348496

RESUMO

Zirconia implants are gaining attention as a viable alternative to titanium implants due to their comparable osseointegration development, improved soft tissue adaptation, and enhanced aesthetics. An encouraging avenue for improving zirconia implant properties involves the potential application of bioactive coatings to their surfaces. These coatings have shown potential for inducing hydroxyapatite formation, crucial for bone proliferation, and improving implant mechanical properties. This study aimed to evaluate the effect of coating zirconia implants with two bioactive glasses, 45S5 and BioK, on osteogenesis in vitro and osseointegration in vivo. Zirconia samples and implants were prepared using Zpex zirconia powder and blocks, respectively. The samples were divided into three groups: polished zirconia (ZRC), zirconia coated with 45S5 bioglass (Z + 45S5), and zirconia coated with BioK glass (Z + BK). Coatings were applied using a brush and sintered at 1200°C. Chemical analysis of the coatings was carried out using x-ray diffraction and Fourier Transform Infrared Spectroscopy. Surface topography and roughness were characterized using scanning electron microscopy and a roughness meter. In vitro experiments used mesenchymal cells from Wistar rat femurs, and the coated zirconia implants were found to promote cell viability, protein synthesis, alkaline phosphatase activity, and mineralization, indicating enhanced osteogenesis. In vivo experiments with 18 rats showed positive results for bone formation and osseointegration through histological and histomorphometric analysis and a push-out test. The findings indicate that bioactive glass coatings have the potential to improve cell differentiation, bone formation, and osseointegration in zirconia implants.


Assuntos
Cerâmica , Implantes Dentários , Próteses e Implantes , Zircônio , Ratos , Animais , Ratos Wistar , Osseointegração , Propriedades de Superfície , Titânio/farmacologia , Titânio/química , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química , Microscopia Eletrônica de Varredura
7.
Clin Oral Investig ; 28(3): 161, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381269

RESUMO

OBJECTIVE: To assess the impact of enhancement filters on the formation of halo artifacts in radiographs of dental implants obtained with a complementary metal oxide semiconductor (CMOS) system. METHODS: Digital radiographs of dental implants placed in dry human mandibles were processed with the Noise Reduction smoothing filter, as well as the Sharpen 1, Sharpen 4, and Sharpen UM high-pass filters available in the CLINIVIEW™ software (Instrumentarium Dental, Tuusula, Finland). Subjective analysis involved evaluating the left, right, and apical surfaces of each implant for the presence of much, few, or no halo. The objective analysis involved measurement of the halo area using the Trainable Weka Segmentation plugin (ImageJ, National Institutes of Health, Bethesda, MD, USA). Data were analyzed using Friedman's test (subjective analysis) and ANOVA (objective analysis) (α = 5%). RESULTS: In the subjective evaluation, the Sharpen 4 filter produced more radiographs with much halo present, and in the objective evaluation, a bigger halo area when compared to the original images and the Noise Reduction filter for all surfaces (p < 0.05). CONCLUSIONS: When evaluating dental implants, priority should be given to original images and those enhanced with smoothing filters since they exhibit fewer halo artifacts. CLINICAL RELEVANCE: Post-processing tools, such as enhancement filters, may improve the image quality and assist some diagnostic tasks. However, little is known regarding the impact of enhancement filters in halo formation on CMOS systems, which have been increasingly used in dental offices.


Assuntos
Artefatos , Implantes Dentários , Estados Unidos , Humanos , Interface Osso-Implante , Óxidos , Semicondutores
8.
Clin Oral Investig ; 28(1): 89, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217802

RESUMO

OBJECTIVE: To evaluate the osseointegration of implants with hydrophobic (HFB) and hydrophilic (HFL) surfaces in a murine model of high-dose bisphosphonates (BPs). MATERIALS AND METHODS: Sixty-four rats were randomly allocated into four groups: control group with HFB implants (CG-HFB), control group with HFL implants (CG-HFL), BP group with HFB implants (BP-HFB), and BP group with HFL implants (BP-HFL). Animals were euthanized after 15 and 45 days (n=8). The dependent variables assessed were the removal torque (biomechanical analysis), the bone volume around the implants (%BV/TV) (microtomographic analysis), the bone-implant contact (%BIC), the bone between the threads (%BBT) (histomorphometric analysis), and the expression of bone metabolism markers (immunohistochemistry analysis). RESULTS: The CG-HFL and BP-HFL groups presented higher removal torque than the CG-HFB and BP-HFB implants. The %BIC of the CG-HFL surfaces was slightly higher than that of the CG-HFB implants. The BP-HFB and BP-HFL groups presented a higher %BIC than that of the CG-HFB and CG-HFL groups (p<0.001). BP therapy also increased the %BBT at both implant surfaces. Higher levels of ALP were observed in the matrix region of bone tissue on the HFL surfaces than on the HFB surfaces. CONCLUSION: Both surfaces enable osseointegration in rats under BP therapy. CLINICAL RELEVANCE: The study demonstrates that hydrophobic (HFB) and hydrophilic (HFL) implant surfaces can promote osseointegration in rats undergoing bisphosphonate therapy. The HFL surfaces exhibited improved biomechanical performance, higher bone-implant contact, and increased bone volume, suggesting their potential clinical relevance for implant success in individuals on bisphosphonate treatment.


Assuntos
Implantes Dentários , Ratos , Camundongos , Animais , Osteogênese , Difosfonatos/farmacologia , Modelos Animais de Doenças , Propriedades de Superfície , Titânio/química , Osseointegração
9.
Biomed Tech (Berl) ; 69(1): 1-10, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-37489593

RESUMO

OBJECTIVES: To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ). CONTENT: Methods to evaluate the stability of dental implants. SUMMARY: A search was performed in the PubMed, Scopus, and Web of Science databases for articles on the proposed subject up to January 29, 2023, using search terms that combined "resonance frequency analysis" and "Periotest" with "correlation" or "relationship"; and combinations of "implant stability quotient" and "Periotest" with "correlation" or "relationship." The inclusion criteria were clinical studies in English involving human subjects who received dental implants and evaluating the correlation between PTV and ISQ. A total of 46 articles were screened, of which 10 were selected for full-text analysis, and eight articles were included in this review. Based on three articles, 75 % of the results of this systematic review showed a negative correlation between PTV and ISQ, regardless of the type of stability assessed. Based on the remaining five articles, 100 % (regardless of the patient's gender) and 66.66 % of the results showed a negative correlation for primary and secondary stability, respectively. There is a negative correlation between PTV and ISQ for both primary and secondary dental implant stability. OUTLOOK: This review can serve as a reference for the development of methodologies for future clinical studies on this topic.


Assuntos
Implantes Dentários , Osseointegração , Humanos , Implantação Dentária Endóssea , Retenção em Prótese Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA