Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.177
Filtrar
1.
Rev. Flum. Odontol. (Online) ; 1(66): 123-133, jan-abr.2025. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1570739

RESUMO

Estabilidade de cor é um requisito estético fundamental das resinas acrílicas provisórias, em especial quando esses materiais são submetidos a longos períodos na cavidade oral. Embora resinas acrílicas temporárias novas e aprimoradas estejam disponíveis, os efeitos da variação térmica e de soluções antissépticas na estabilidade de cor de resinas acrílicas provisórias ainda não foram completamente elucidados. Portanto, este estudo avaliou a coloração de resinas autopolimerizáveis polimetilmetacrilato (PMMA) e bis-acrilo submetidas à termociclagem e imersão em clorexidina. Amostras padronizadas (n=10) foram preparadas de duas resinas acrílicas temporárias a base de PMMA (Alike® e Duralay®). Foram realizadas três avaliações de cor (T1 ­ 24h após o preparo da amostra, T2 ­ após termociclagem e T3 ­ após termociclagem e imersão em clorexidina) por meio de espectrofotômetro eletrônico de seleção de sombra (Vita Easy Shade). Os dados obtidos foram analisados por ANOVA e teste t (α=0,05). As resinas de PMMA Alike e Duralay apresentaram alteração de cor após a termociclagem e também após a imersão em clorexidina.


Color stability is a fundamental aesthetic requirement for temporary acrylic resins, especially when these materials are subjected to long periods in the oral cavity. Although new and improved temporary acrylic resins are available, the effects of thermal variation and antiseptic solutions on the color stability of temporary acrylic resins have not yet been fully elucidated. Therefore, this study evaluated the color of self-polymerizing resins polymethyl methacrylate (PMMA) and bis-acryl subjected to thermocycling and immersion in chlorhexidine. Standardized samples (n=10) were prepared from two PMMA-based temporary acrylic resins (Alike® and Duralay®). Three color evaluations were carried out (T1 ­ 24h after sample preparation, T2 ­ after thermocycling and T3 ­ after thermocycling and immersion in chlorhexidine) using an electronic shade selection spectrophotometer (Vita Easy Shade). The data obtained were analyzed by ANOVA and t test (α=0.05). PMMA Alike and Duralay resins showed color changes after thermocycling and also after immersion in chlorhexidine.

2.
Rev. Ciênc. Plur ; 10(2): 35080, 29 ago. 2024. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1570459

RESUMO

Introdução:Na odontologia moderna, a estética vem ocupando um espaço cada vez mais expressivo, e o desejo por dentes mais brancos, a insatisfação com o alinhamento dos dentes e com a anatomia dentária, têm sido os motivos mais relevantes de procura dos pacientes nos consultórios odontológicos.Objetivo:O presente artigo tem como objetivo descrever, através de relato de caso clínico, uma abordagem terapêutica estética e conservadora para fechamento de múltiplos diastemas anterossuperiores com a utilização de facetas de resina composta.Relato de caso:Paciente do sexo masculino, 21 anos de idade, procurou atendimento queixando-se de insatisfação estética pelos diastemas apresentados. Por meio de um planejamento digital das facetas em resina, com mockup e modelo impresso em 3D, as restaurações foram feitas respeitando anatomia, forma, opacidade e cores dos dentes naturais do paciente. O resultado dos procedimentos adotados foi satisfatório, demonstrando que a técnica empregada foi eficaz, sendo capaz de devolver um sorriso estético e biológico ao paciente. A odontologia contemporânea tem ofertado cada vez mais materiais com capacidade de devolver estética e função em dentes de forma minimamente invasivas, além de passar total confiabilidade em tratamentos a longo prazo, agradando o paciente desde a apresentação digital do planejamento traçado pelo cirurgião dentista com previsibilidade dos resultados, até o momento final do tratamento.Conclusões:O recontorno estético com resina composta representa uma opção funcional e de baixo custo para o tratamento de pacientes que apresentam diastemas múltiplos, principalmente em pacientes jovens pela preservação daestrutura dentária e possibilidade de reparo, sendo considerado um procedimento reversível, rápido e de baixo custo (AU).


Introduction:Aesthetics have been occupying an increasingly significant role in modern dentistry, and the desire for whiter teeth, dissatisfaction with tooth alignment, and dental anatomy concerns have been the most relevant reasons for patients seeking dental care. Objective:This article aims to describe an aesthetic and conservative therapeutic approach for closing multiple anterior upper diastemas using composite resin veneers in a clinical case report. Case report:A 21-year-old male patient sought treatment, expressing dissatisfaction with the diastemas he had. The restorations were performed using digital planning of the resin veneers with a mockup and a 3D-printed model, while respecting the patient's natural tooth anatomy, shape, opacity, and colors. The results of the adopted procedures were satisfactory, demonstrating effectiveness of the employed technique in restoring an aesthetic and biologically harmonious smile to the patient. Contemporary dentistry has been offering increasingly more materials capable of providing aesthetics and function to teeth through minimally invasive approaches. This not only ensures long-term treatment reliability, but also pleases the patient with a digital presentation of the treatment plan outlined by the dentist, predicting the results up to the final stages of the treatment. Conclusions:Aesthetic contouring using composite resin presents a functional and cost-effective option for treating patients with multiple diastemas, especially among young patients due to its preservation of dental structure, repair potential, and being considered a reversible, fast, and low-cost procedure (AU).


Introducción: En la odontología moderna, la estética viene ocupando un espacio cada vez más destacado, y las ganas de tener dientes más blancos, la insatisfacción con el alineamiento de los dientes, y la anatomía dental son las razonesmás relevantes por las cuales los pacientes acuden a las consultas odontológicas. Objetivo:El presente artículo tiene como objetivo describir, a través de un relato de caso clínico, un abordaje terapéutico estético y conservador para el cierre de múltiples diastemas anterosuperiores mediante el uso de carillas de resina compuesta. Informe de caso:Paciente del sexo masculino, 21 años de edad, buscó atendimiento quejándose de insatisfacción estética debido a los diastemas presentados. A través de una planificación digital de las carillas en resina, con un mockup y un modelo impreso en 3D, las restauraciones fueron ejecutadas, respetándose la anatomía, forma, opacidad y colores de los dientes naturales del paciente. El resultado de los procedimientos adoptados fue satisfactorio y demostró que la técnica utilizada fue eficaz, siendo capaz de restituir una sonrisa estética y funcional al paciente. La odontología contemporánea viene ofreciendo cada vez más materiales con la capacidad de devolver estética y función a los dientes de maneras mínimamente invasivas, además de brindar total confiabilidad en tratamientos a largo plazo, satisfaciendo al paciente desde la presentación digital del plan trazado por el cirujano dentista con la previsibilidad de los resultados, hasta el momento final del tratamiento. Conclusiones:El recontorneado estético con resina compuesta representa una opción funcional y de bajo costo para el tratamiento de pacientes con múltiples diastemas, especialmente en pacientes jóvenes, debido a la preservación de la estructura dental y la posibilidad de reparación. Se considera, de este modo, que se trata de un procedimiento reversible, rápido y económico (AU).


Assuntos
Humanos , Masculino , Adulto , Resinas Compostas/química , Facetas Dentárias , Diastema/terapia , Estética Dentária , Procedimentos Cirúrgicos Minimamente Invasivos
3.
J Esthet Restor Dent ; 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095320

RESUMO

OBJECTIVE: To evaluate the fracture behavior of human molars with extensive MOD restorations using short-fiber-reinforced resin composite of varying viscosities. MATERIALS AND METHODS: Human molars were randomly divided into seven groups (n = 12): intact teeth (control); restoration using conventional high-viscosity resin composite without (Filtek Z350XT, 3M) or with fibers (everX Posterior, GC); conventional low-viscosity resin composite without (Filtek Supreme Flowable, 3M) or with fibers (everX Flow Dentin Shade, GC); bulk-fill low-viscosity resin composite (Filtek Bulk Fill Flow, 3M) or with fibers (everX Flow Bulk Shade, GC). Restorations were performed on extensive MOD preparations, following the manufacturers' recommendations for each material. Specimens underwent fracture strength testing (N) and fracture pattern (%) categorized as repairable, possibly repairable, or non-repairable. Results were analyzed using a generalized linear model (N) and Fisher's exact test (%), with α = 0.05. RESULTS: Restorations performed with high-viscosity materials showed fracture strength values similar to the control and higher than those of restorations using low-viscosity resin composites (p < 0.0001), except for the bulk-fill low-viscosity resin composite with fibers (p > 0.05). Teeth restored using low-viscosity resin composite with fibers showed a higher % of repairable and possibly repairable fractures than the control (p = 0.0091). CONCLUSIONS: The viscosity of materials mediated the fracture strength, with restorations using high-viscosity resin composites promoting values similar to the intact tooth; however, the presence of fibers influenced the fracture pattern. CLINICAL SIGNIFICANCE: Teeth with MOD cavities restored with high-viscosity resin composites showed similar fracture strength to intact teeth. Fiber-reinforced low-viscosity resin composite for the base of restoration resulted in a more repairable/possibly repairable fracture pattern.

4.
Polymers (Basel) ; 16(15)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39125196

RESUMO

The objective was to compare the color match and color stability behavior of single- and multi-shade resin-based composites (RBCs) used for direct restorations. This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Randomized clinical trials evaluating the shade performance of single-shade RBCs in direct restorations were included. A search of the scientific literature was performed in five databases (April 2024). The meta-analysis was performed using RevMan 5.4, calculating the risk difference (RD) and 95% confidence interval (CI) of the dichotomous outcome using a random effects model. Bias was assessed using the RoB 2.0 tool, and certainty of evidence was assessed using the GRADEpro tool. Four studies were selected, with 263 restorations analyzed. The results showed comparable performance between single-shade RBCs and multi-shade RBCs in terms of color match and color stability over 12 months. Three studies had a low risk of bias with all expected results, and one study had some concerns. The certainty of evidence for color stability was considered low for all follow-up periods due to the small number of events and sample size. According to the United States Public Health Service Evaluation (USPHS) and the World Dental Federation (FDI), there is comparable clinical color performance between single-shade and multi-shade RBCs over 12 months.

5.
Rev Cient Odontol (Lima) ; 12(1): e185, 2024.
Artigo em Espanhol | MEDLINE | ID: mdl-39015313

RESUMO

Objective: Compare the surface roughness of two composite resins after immersion in carbonated beverages. Materials and methods: 160 resin discs (6 x 2 mm) were divided into 8 groups (n=20 per group) according to type of resin (Filtek™ Z350 XT® and Palfique LX5®) and type of immersion in beverages (distilled water, Coca Cola®, Inca Kola® and Kola Escocesa®. The immersions were carried out under a structured cycle: 4 immersions a day for 5 days, intermediate storage in distilled water and overnight incubation for 8 h at 37°C. The measurements with the roughness meter were evaluated in three times: baseline, 7 and 14 days. The three-way Anova test was used at P<0.05. Results: Roughness showed differences only for the individual factors of time (P<0.000) and resin (P=0.000), and for the interaction time*drink (P=0.000) and resin*drink (P=0.003). Roughness was higher with Filtek Z350 XT® immersed with Inca Kola® (0.85 ± 0.37) than 14 days compared to other times (P=0.035) and with Palfique LX5 immersed in Coca Cola® at 7 days (1.61 ± 0.42) and in Inca Kola® at 14 days (1.66 ± 0.56) compared to distilled water (P<0,05). Conclusion: Surface roughness was affected by the type of resin, the type of soft drink and the immersion time. The roughness was greater with the Palfique LX5® nanohybrid resin, the Inca Kola® drink and after 14 days of immersion.

6.
Rev. ADM ; 81(3): 170-176, mayo-jun. 2024. ilus
Artigo em Espanhol | LILACS | ID: biblio-1567149

RESUMO

El avance de la tecnología permite realizar cambios en la rehabilitación y estética, reduce los tiempos de trabajo y disminuye los riesgos que se presentan al momento de utilizar materiales convencionales para la toma de impresiones. Existen dos técnicas que se pueden emplear, la analógica y la digital; la primera presenta mayores riesgos que el operador no puede controlar, así como tiempos más prolongados. Este reporte describe la rehabilitación bucal en dos pacientes con desgaste dental, se optó por usar ambas técnicas, la analógica y la digital, como tratamiento; en la primera se empleó el encerado convencional y en la segunda el software Exocad para el encerado digital. Finalmente en ambos casos se aplicó (AU)


The advance of technology has allowed changes in rehabilitation and esthetics, providing shorter working times and reducing the risks that occur when using conventional materials for taking impressions. There are two techniques that can be used, analog and digital, the first one presents greater risks that the operator cannot control, as well as more time. This report describes the oral rehabilitation in patients with dental wear. The treatment was carried out using the analogical and digital techniques, the former using conventional waxing and the latter using Exocad software for the digital waxing; finally, in both cases the injection technique with high-load Flow resin was used (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Estética Dentária , Desgaste dos Dentes/reabilitação , Planejamento de Assistência ao Paciente , Processamento de Imagem Assistida por Computador , Injeções
8.
J. oral res. (Impresa) ; 13(1): 160-169, mayo 29, 2024. ilus
Artigo em Inglês | LILACS | ID: biblio-1563437

RESUMO

Objective: To evaluate the influence of opacity and the layering technique on the fluorescence of different composite resins. Materials and Methods: Two opacities (enamel and dentin) and the layering technique (enamel + dentin) of the composite resins: Filtek® Z350 and Palfique LX5 were evaluated in vitro. Composite resin discs were fabricated using a preformed matrix of 10 mm diameter and 0.5 mm thick for the single opacity groups and 10 mm thick for the layering technique groups, using 2 layers of 0.5 mm thickness of each opacity (n = 5). Specimens were analyzed using the Raman spectroscopy method. Data were analyzed using the Kruskall-wallis and Mann-Whitney U tests. Results: When evaluating the intensity of fluorescence, no statistically significant difference was found when comparing the layering technique and enamel opacity (p2> 0.05) and an increase in the dentin opacity value for both brands of composite resin. Regarding wavelength, no statistically significant difference was found when comparing the layering technique with enamel opacity and dentin opacity for both Filtek® Z350 and Palfique LX5® composite resins (p2 > 0.05). Conclusions: The fluorescence intensity of the layering technique is similar to enamel opacity for both composite resins. Likewise, the wavelength of the layering technique is similar to the enamel opacity and dentin opacity for both brands.


Objetive: Evaluar la influencia de la opacidad y de la técnica de estratificación en la fluorescencia de diferentes resinas compuestas. Materiales y Métodos: Se evaluó in vitro 2 opacidades (Esmalte y Dentina) y la técnica de estratificación (Esmalte + Dentina) de las resinas compuestas: Filtek® Z350 y Palfique LX5. Se fabricaron discos de resina compuesta, utilizando una matriz preformada de 10 mm de diámetro y 0,5 mm de grosor para los grupos de opacidad única y 10 mm de grosor para los grupos de técnica estratificada, utilizando 2 capas de 0,5 mm de cada opacidad (n = 5). Los especímenes se analizaron mediante el método de Espectroscopía Raman. Los datos se analizaron utilizando la prueba de Kruskall-wallis y Prueba U de Mann Whitney. Resultado: Al evaluar la intensidad de fluorescencia no se encontró diferencia estadísticamente significativa entre los pares: Técnica estratificada versus Opacidad Esmalte para ambas marcas de resina compuesta Filtek® Z350 y para Palfique LX5® (p2 > 0,05). Para longitud de onda no se encontró diferencia estadísticamente significativa entre los pares: Técnica estratificada versus Opacidad Esmalte y Técnica estratificada VS Opacidad Dentina para ambas resinas compuesta Filtek® Z350 y Palfique LX5® (p2> 0,05). Conclusión: La intensidad de fluorescencia de la técnica estratificada es similar a la opacidad Esmalte para ambas resinas compuestas. De igual manera la longitud de onda de la técnica estratificada es similar a la opacidad Esmalte y opacidad Dentina para ambas marcas.


Assuntos
Humanos , Resinas Compostas/química , Nanotecnologia/métodos , Análise Espectral , Técnicas In Vitro
9.
Materials (Basel) ; 17(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38612010

RESUMO

The present study aimed to characterize the microstructure of a temporary 3D printing polymer-based composite material (Resilab Temp), evaluating its optical properties and mechanical behavior according to different post-curing times. For the analysis of the surface microstructure and establishment of the best printing pattern, samples in bar format following ISO 4049 (25 × 10 × 3 mm) were designed in CAD software (Rhinoceros 6.0), printed on a W3D printer (Wilcos), and light-cured in Anycubic Photon for different lengths of time (no post-curing, 16 min, 32 min, and 60 min). For the structural characterization, analyses were carried out using Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM). The mechanical behavior of this polymer-based composite material was determined based on flexural strength tests and Knoop microhardness. Color and translucency analysis were performed using a spectrophotometer (VITA Easy Shade Advanced 4.0), which was then evaluated in CIELab, using gray, black, and white backgrounds. All analyses were performed immediately after making the samples and repeated after thermal aging over two thousand cycles (5-55 °C). The results obtained were statistically analyzed with a significance level of 5%. FT-IR analysis showed about a 46% degree of conversion on the surface and 37% in the center of the resin sample. The flexural strength was higher for the groups polymerized for 32 min and 1 h, while the Knoop microhardness did not show a statistical difference between the groups. Color and translucency analysis also did not show statistical differences between groups. According to all of the analyses carried out in this study, for the evaluated material, a post-polymerization time of 1 h should be suggested to improve the mechanical performance of 3D-printed devices.

10.
Sci Rep ; 14(1): 8075, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38580685

RESUMO

During the preparation of fixed prosthesis (including individual bridges and crowns) it is important to select the materials that have the best features and properties to predict a successful clinical treatment. The objective of this study was to determine if the chemical and structural characteristics could cause to increase the fracture resistance, we used four bis-acryl resins Luxatemp, Protemp, Structur and Telio. Three-points bending by Flexural test were performed in ten bars and they were carried out to compare with Anova test. In addition, the bis-acryl resins were analyzed by scanning electron microscopy, to analyze microstructure and morphology and the molecular structure were performed by Infrared Spectroscopy through Attenuated Total Reflectance. A higher flexural strength was found in Luxatemp and Structur with, no significant differences between this study groups. Regarding Protemp and Telio, these study groups showed a lower flexural strength when were compared with Luxatemp and Structur. These results corroborate SEM and ATR analysis because Luxatemp sample showed a regular size particle on the surface and chemically presents a long cross-linkage polymer chain. The presence of CO3, SiO2 and N-H groups as a fillers particle interacting with OH groups cause a higher flexural strength compared with another groups.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA