Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1193: 339394, 2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35058015

RESUMO

Alzheimer disease (AD) is a neurodegenerative disorder characterized by extracellular accumulation of amyloid-ß peptide (Aß) in the brain interstitium. Human serum albumin (HSA) highly binds to Aß in blood plasma and is thought to inhibit plaque formation in peripheral tissue. Thus, the evaluation of albumin binding to Aß is an important key to understand the dynamics of these molecules in the biological system of patients with AD. In this work, a fiber-in-tube solid-phase microextraction (fiber-in-tube SPME) and ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to estimate Aß fraction binding to HSA in cerebrospinal fluid (CSF) and plasma samples. Crosslinked zwitterionic polymeric ionic liquid (zwitterionic PIL)-coated nitinol wires were developed and packed into a polyether ether ketone (PEEK) capillary for a fiber-in-tube SPME and UHPLC-MS/MS method. Zwitterionic PIL sorbent was synthetized from 1-vinyl-3-(butanesulfonate)imidazolium ([VIm+C4SO3-]) and 1,12-di(3-vinylimidazolium)dodecane dibromide ([(VIm)2C12]2[Br]) monomers by in-situ thermally-initiated polymerization. Morphological characterization by scanning electron microscopy (SEM) and atomic force microscopy (AFM) revealed a decrease in the surface roughness of the nitinol wires from ∼17 nm to 1 nm after the in-situ polymerization. The zwitterionic PIL sorbent selectively preconcentrates Aß through a two-pronged interaction mechanism. The fiber-in-tube SPME and UHPLC-MS/MS method presented lower limits of quantification (LLOQ) of 0.4 ng mL-1 for Aß38 and 0.3 ng mL-1 for Aß40 and Aß42, a linear range from LLOQ values to 15 ng mL-1 with coefficients of determination higher than 0.99, precision with coefficient of variation (CV) values ranging from 2.1 to 7.3% and accuracy with relative standard deviation (RSD) values from -0.3 to 7.4. This method was successfully applied to evaluate the binding of HSA to Aß in cerebrospinal fluid (CSF) and plasma samples.


Assuntos
Peptídeos beta-Amiloides , Líquidos Iônicos , Ligas , Proteínas de Transporte , Cromatografia Líquida de Alta Pressão , Humanos , Microextração em Fase Sólida , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA