Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Int. j. morphol ; 42(1): 52-58, feb. 2024. ilus
Artigo em Inglês | LILACS | ID: biblio-1528829

RESUMO

SUMMARY: In bovines, anatomical observations of the coronary vascular tree describe qualitative characteristics. The objective of this study was to morphometrically characterize the coronary veins and their tributaries in cattle. An arcuate application with 2.0 silk was performed around the ostium of the coronary sinus of 28 bovine hearts and a number 14 catheter was placed, through which semi- synthetic polyester resin and mineral blue color was perfused. In 22 hearts (78.6 %) the great cardiac vein was originated at the cardiac apex. The configuration of the arteriovenous trigone was mainly closed inferior and superior types (50 %). The caliber of the great cardiac vein at the level of the atrioventricular sulcus was 6.7 +/- 1.2 mm. The origin of the left marginal vein was observed in the lower third of the left cardiac margin (53.6 %), its distal caliber was 4.1 +/- 0.8 mm and its drainage was at the level of the great cardiac vein. The middle cardiac vein originated from the cardiac apex in 78.6 % of the samples, emptied mainly into the coronary sinus (82.1 %) and its distal caliber was 4.7 +/- 0.9 mm. Anastomoses occurred in 28.6 % of the hearts, being found in most cases between the middle cardiac vein and the great cardiac vein (50 %), which was significant compared to other anastomoses (p<0.001). The length of the coronary sinus was 42.2 +/- 5.1 mm, its distal caliber was 13.8 +/- 2 mm, and its shape was cylindrical. Myocardial bridges were found in 3 hearts (10.7 %) mainly in the lower third of the middle cardiac vein (66.6 %). Most of the main coronary veins drained into the coronary sinus, with some cases with atypical outlets and the presence of a high percentage of anastomosis that serves to improve cardiac venous drainage in case of venous compression or obstruction.


En bovinos, las observaciones anatómicas de árbol vascular coronario describen características cualitativas. El objetivo de este estudio fue caracterizar morfométricamente las venas coronarias y sus tributarias en bovinos. Se realizó una aplicatura arciforme con seda 2.0 alrededor del ostium del seno coronario de 28 corazones de bovino y se colocó un catéter número 14, a través del cual se perfundió resina de poliéster semisintética y color azul mineral. La vena cardiaca magna se originó en 22 corazones (78,6 %) en el ápex cardiaco. La configuración del trígono arteriovenoso fue principalmente cerrado inferior y superior (50 %). El calibre de la vena cardiaca magna a nivel del surco atrioventricular fue 6,7 +/- 1,2 mm. El origen de la vena marginal izquierda se observó en el tercio inferior del margen izquierdo cardiaco (53,6 %), su calibre distal fue 4,1 +/- 0,8 mm y su desembocadura fue a nivel de la vena cardiaca magna. La vena cardiaca media se originó en el ápex cardiaco en el 78,6 % de las muestras, desembocó principalmente en el seno coronario (82.1 %) y su calibre distal fue 4,7 +/- 0,9 mm. Se presentó anastomosis en el 28,6 % de los corazones, encontrándose en la mayoría de los casos entre la vena cardiaca media y la vena cardiaca magna (50 %), lo cual fue significativo en comparación con otras anastomosis (p<0,001). La longitud del seno coronario fue 42,2 +/- 5,1 mm, su calibre distal fue 13,8 +/- 2 mm y su forma fue cilíndrica. Se encontró puentes miocárdicos en 3 corazones (10,7 %) y en el tercio inferior de la vena cardiaca media (66,6 %). La mayoría de las venas coronarias principales desembocan en el seno coronario, con algunos casos con desembocaduras atípicas y la presencia de un alto porcentaje de anastomosis que sirve para mejorar el drenaje venoso cardiaco en caso de compresión u obstrucción venosa.


Assuntos
Animais , Bovinos , Bovinos/anatomia & histologia , Vasos Coronários/anatomia & histologia , Veias , Estudos Transversais , Seio Coronário/anatomia & histologia
2.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1558558

RESUMO

Las extrasístoles ventriculares (EEVV) son frecuentemente asintomáticas y no requieren de tratamiento antiarrítmico. Las EEVV de los tractos de salida son las EEVV idiopáticas más frecuentes en la práctica clínica. La anamnésis, el examen físico y el electrocardiograma son fundamentales en el diagnóstico. Aunque las EEVV de los tractos de salidas ventriculares son consideradas benignas, pueden producir diversos síntomas y desencadenar una cardiomiopatía inducida por las extrasístoles, que lleva a un deterioro de la función sistólica ventricular izquierda y en última instancia, insuficiencia cardiaca. Cuando el tratamiento farmacológico de las EEVV fracasa, nos queda la ablación de arritmias por catéter de radiofrecuencia como única alternativa eficaz. Este es el caso de la paciente de sexo femenino de 62 años, hipertensa, dislipidémica y tabaquista, que demuestra la seguridad de la ablación por catéter de radiofrecuencia, la eficacia terapéutica, y el restablecimiento integro de la función ventricular del corazón.


Premature ventricular complexes (PVC) are frequently asymptomatic and do not require antiarrhythmic treatment. Outflow tract PVC are the most common idiopathic PVC in clinical practice. The anamnesis, physical examination and electrocardiogram are essential in the diagnosis of these patients. Although PVC of the ventricular outflow tracts are considered benign, they can produce various symptoms such as dyspnea on exertion, asthenia, palpitations, dizziness, presyncope or syncope, and in those patients with very high arrhythmic burden (>24% on a 24-hour Holter monitoring), can trigger extrasystole-induced cardiomyopathy, leading to deterioration of left ventricular systolic function and ultimately heart failure. When pharmacological treatment of PVC fails, ablation of arrhythmias by radiofrequency catheter is the only effective alternative. This is the case of the 62-year-old female patient, hypertensive, dyslipidemic and a smoker, which demonstrates the safety of radiofrequency catheter ablation, the therapeutic efficacy, and the complete restoration of the ventricular function of the heart.

3.
Rev. mex. anestesiol ; 45(2): 87-91, abr.-jun. 2022. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1395022

RESUMO

Resumen: Introducción: Se han propuesto varios métodos para controlar la inflamación y preservar el miocardio durante la circulación extracorpórea (CEC), entre ellos podemos mencionar la administración de electrolitos, tales como el magnesio (Mg2+). Objetivo: Comparar el efecto del uso de sulfato de magnesio (MgSO4) prepinzamiento aórtico (pre-PAo) vs placebo sobre los niveles séricos de lactato en el seno coronario en pacientes sometidos a revascularización miocárdica (RVM) multivaso con CEC. Material y métodos: Se realizó un ensayo clínico controlado en 52 pacientes sometidos a RVM multivaso con CEC, aleatorizados para recibir placebo (grupo I) o MgSO4 (grupo II) pre-PAo, y se tomaron muestras sanguíneas del seno coronario en dos tiempos diferentes: T0: pre-PAo y T1: previo al cierre de tórax, cuantificándose el lactato sérico. Para su análisis, se utilizó t de Student y χ2. Una p < 0.05 fue significativa. La información se procesó en SPSS v-22.0. Resultados: Los niveles séricos de lactato en el seno coronario postpinzamiento aórtico (pos-PAo) fueron menores en el grupo II (2.967 ± 0.86 vs 2.154 ± 1.14) mostrando diferencias significativas (p = 0.006). Conclusión: El uso de MgSO4 pre-PAo disminuye los niveles séricos de lactato en el seno coronario en pacientes sometidos a RVM multivaso con CEC.


Abstract: Introduction: Several methods have been proposed to control inflammation and to preserve the myocardium during cardiopulmonary bypass (CABG), including the administration of electrolytes such as magnesium (Mg2+). Objective: To compare the effect of using magnesium sulfate (MgSO4) or a placebo before aortic clamping (AoC) on the serum levels of lactate in the coronary sinus in patients undergoing myocardial multivessel revascularization (MRV) with CABG. Material and methods: A clinical assay was conducted with 52 patients undergoing MRV multivessel with CEC; the patients were randomized to receive a placebo (group I) or MgSO4 (group II) before AoC, and blood samples were taken from the coronary sinus to quantify serum lactate at two different times: T0: pre-AoC and T1: before closing the chest. Statistical analysis was performed on Student's t-test and χ2. A p < 0.05 was considered statistically significant. The data were processed with SPSS v-22.0. Results: Serum levels of lactate in the coronary sinus post-AoC were lower in group II (2.967 ± 0.86 vs 2.154 ± 1.14), with significant differences (p = 0.006). Conclusion: The use of MgSO4 before AoC reduces serum lactate levels in the coronary sinus in patients undergoing MRV multivessel with CABG.

4.
Rev. colomb. cardiol ; 29(2): 240-243, ene.-abr. 2022. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1376885

RESUMO

Resumen El implante percutáneo de un electrodo de estimulación ventricular izquierdo a través del seno coronario para resincronización cardiaca siempre ha implicado un reto y más aún en pacientes con anatomía venosa coronaria compleja. Este caso demuestra cómo una técnica de doble canulación del seno coronario con uso de catéter multi-snare permite la colocación exitosa de un electrodo de estimulación ventricular izquierdo mediante acceso retrógrado a una vena posterolateral estenótica.


Abstract The percutaneous implantation of a left ventricular pacing electrode through the coronary sinus for cardiac resynchronization has always been a challenge, especially in patients with a complex coronary venous anatomy. This case shows how double cannulation of the coronary sinus using a multisnare catheter allows a left ventricular pacing electrode to be placed through retrograde access to a stenotic posterolateral vein, with a good clinical outcome.

5.
Rev. colomb. cardiol ; 29(1): 111-114, ene.-feb. 2022. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1376863

RESUMO

Resumen Se presenta el caso de una paciente con atrapamiento de guía al interior del seno coronario durante el procedimiento de cambio de un electrodo (Sentus ProMRI OTW BP L-85) por desalojo asociado a disfunción de la terapia de resincronización cardiaca. Durante el implante del nuevo electrodo se presentó atrapamiento y retención intravascular de la guía utilizada para su posicionamiento a nivel del seno coronario, lo cual hizo imposible su remoción. La paciente no aceptó tratamiento quirúrgico, se encuentra en vigilancia médica y permanece asintomática desde hace 3 años.


Abstract It is reported the case of a patient with guidewire trapping inside the coronary sinus during an electrode exchange procedure (Sentus ProMRI OTW BP L-85) due to dislocation associated with dysfunction of cardiac re-synchronization therapy. During the implantation of the new electrode, entrapment of the guidewire used for its positioning at the level of the coronary sinus and intravascular retention were presented, making it impossible to remove it. The patient did not accept surgical treatment and has been under medical surveillance, asymptomatic for three years.

6.
Rev. bras. cir. cardiovasc ; 36(5): 707-716, Sept.-Oct. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1351644

RESUMO

Abstract Introduction: Rapid prototyping is a process by which three-dimensional (3D) computerized surface models are converted into physical models. In this study, a 3D heart bio model was created using the rapid prototyping method and the accuracy of this heart model was assessed by clinicians. Methods: The two-dimensional images of normal heart from gated computed tomography scan datasets were used to create a 3D model of the heart. The slices were then processed using the software BioModroid and printed with the 3D printer. The evaluation of the model was performed by a questionnaire answered by four cardiothoracic surgeons, 12 cardiologists, five radiologists, and nine surgical registrars. Results: Eighty-six percent of the anatomy structures showed in this model scored 100% accuracy. Structures such as circumflex branch of left coronary artery, great cardiac vein, papillary muscle, and coronary sinus were each rated 77%, 70%, 70%, and 57% accurate. Among 30 clinicians, a total of 93% rated the model accuracy as good and above; 64% of the clinicians evaluated this model as an excellent teaching tool for anatomy class. As a visual aid for surgery or interventional procedures, the model was rated excellent (40%), good (50%), average (23%), and poor (3%); 70% of the clinicians scored the model as above average for training purpose. Overall, this 3D rapid prototyping cardiac model was rated as excellent (33%), good (50%), and average (17%). Conclusion: This 3D rapid prototyping heart model will be a valuable source of anatomical education and cardiac interventional management.


Assuntos
Humanos , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Projetos Piloto , Coração , Modelos Anatômicos
7.
Arch Argent Pediatr ; 119(5): e526-e530, 2021 10.
Artigo em Espanhol | MEDLINE | ID: mdl-34569756

RESUMO

Hydrocephalus is a clinical condition that consists of an accumulation of cerebrospinal fluid around the brain; Dandy- Walker syndrome is a rare cause of it. We present the case of a newborn with prenatal diagnose of hydrocephalus due to a Dandy-Walker malformation, as well as ambiguous genitalia. After birth, diagnosis of Dandy-Walker malformation associated with uncommon extracranial manifestations is confirmed. Specifically, the baby presents interscrotal hypospadias and coronary sinus dilatation due to the persistence of the left superior vena cava. With the exposition of this case, we bring Malformación de Dandy-Walker asociada a malformaciones extracraneales en un neonato Dandy-Walker malformation associated with extracranial abnormalities in a newborn out the complexity of the Dandy-Walker syndrome due to the malformations associated with it; the ones that will determine the prognosis and the need of a multidisciplinary treatment.


La hidrocefalia es una condición clínica que consiste en un cúmulo de líquido cefalorraquídeo a nivel encefálico. Una de las causas, poco frecuente, es el síndrome de Dandy-Walker. Se presenta el caso de un recién nacido con diagnóstico prenatal de hidrocefalia secundaria a una malformación de Dandy- Walker y sospecha de genitales ambiguos. Tras el nacimiento, se confirma el diagnóstico prenatal de malformación de Dandy-Walker asociado a manifestaciones extracraneales poco frecuentes como hipospadias interescrotal y dilatación del seno coronario secundario a persistencia de la vena cava superior izquierda. Con este caso clínico queremos exponer la complejidad del síndrome de Dandy-Walker debido a sus múltiples asociaciones, que marcarán el pronóstico del paciente y la necesidad de tratamiento multidisciplinar.


Assuntos
Síndrome de Dandy-Walker , Hidrocefalia , Encéfalo , Síndrome de Dandy-Walker/complicações , Síndrome de Dandy-Walker/diagnóstico , Feminino , Humanos , Hidrocefalia/diagnóstico , Hidrocefalia/etiologia , Lactente , Recém-Nascido , Masculino , Gravidez , Prognóstico , Veia Cava Superior
8.
Braz J Cardiovasc Surg ; 36(2): 265-267, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34048204

RESUMO

Coronary artery to left atrial fistula is rare in patients with mitral stenosis. We report an interesting case of a patient with concomitant mitral valve stenosis and coronary fistulae, originating from the left circumflex artery and drained into the left atrium with two terminal orifices.


Assuntos
Fístula , Hipertensão Pulmonar , Estenose da Valva Mitral , Vasos Coronários/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico por imagem , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia
9.
Arch. argent. pediatr ; 119(5): e526-e530, oct. 2021. ilus
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1292776

RESUMO

La hidrocefalia es una condición clínica que consiste en un cúmulo de líquido cefalorraquídeo a nivel encefálico. Una de las causas, poco frecuente, es el síndrome de Dandy-Walker. Se presenta el caso de un recién nacido con diagnóstico prenatal de hidrocefalia secundaria a una malformación de Dandy-Walker y sospecha de genitales ambiguos. Tras el nacimiento, se confirma el diagnóstico prenatal de malformación de Dandy-Walker asociado a manifestaciones extracraneales poco frecuentes como hipospadias interescrotal y dilatación del seno coronario secundario a persistencia de la vena cava superior izquierda. Con este caso clínico queremos exponer la complejidad del síndrome de Dandy-Walker debido a sus múltiples asociaciones, que marcarán el pronóstico del paciente y la necesidad de tratamiento multidisciplinar.


Hydrocephalus is a clinical condition that consists of an accumulation of cerebrospinal fluid around the brain; Dandy-Walker syndrome is a rare cause of it. We present the case of a newborn with prenatal diagnose of hydrocephalus due to a Dandy-Walker malformation, as well as ambiguous genitalia. After birth, diagnosis of Dandy-Walker malformation associated with uncommon extracranial manifestations is confirmed. Specifically, the baby presents interscrotal hypospadias and coronary sinus dilatation due to the persistence of the left superior vena cava. With the exposition of this case, we bring out the complexity of the Dandy-Walker syndrome due to the malformations associated with it; the ones that will determine the prognosis and the need of a multidisciplinary treatment


Assuntos
Humanos , Masculino , Gravidez , Recém-Nascido , Síndrome de Dandy-Walker/complicações , Síndrome de Dandy-Walker/diagnóstico , Hidrocefalia/diagnóstico , Hidrocefalia/etiologia , Prognóstico , Veia Cava Superior , Encéfalo
10.
Rev. colomb. cardiol ; 28(2): 180-184, mar.-abr. 2021. graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1341281

RESUMO

Resumen La anomalía de Ebstein es una cardiopatía congénita poco común que se asocia a la presencia de vías de conducción anómalas y episodios de taquicardia supraventricular frecuentes, algunos inestables. La asociación con alteraciones anatómicas del seno coronario es rara y no ha sido reportada. Se presenta el caso de una paciente de 58 años con enfermedad coronaria, anomalía de Ebstein, episodios de taquicardia ortodrómica y aneurisma del seno coronario, a quien se realizó ablación.


Abstract Ebstein’s disease is a congenital cardiomyopathy, with a low prevalence in the general population. This abnormality has been associated with abnormal cardiac conduction problems, one of the most important being the accessory pathways. In the presence of an accessory pathway, frequent supraventricular tachycardias may occur, some of which are poorly tolerated. The association with the anomalies of the coronary sinus is not currently reported. The case of a 58-year-old woman with Ebstein’s disease, episodes of supraventricular tachycardia, and coronary sinus aneurysm undergoing ablation therapy is presented.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Anomalia de Ebstein , Seio Coronário , Feixe Acessório Atrioventricular , Aneurisma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA