1.
Artigo em Inglês | MEDLINE | ID: mdl-39037121

RESUMO

BACKGROUND: The aim of this case study is to present the rationality and scientific evidence of a new design for a double (DA) and triple (TA) dental abutment-implant with their specific new concept of biodynamic optimized peri-implant tissue (BOPiT). METHODS: The innovative design of these abutments with a paraboloid geometry was based on BOPiT, simultaneously involving the principles of mechanobiology, biotensegrity, and mechanotransduction. Thus, 37 consecutive individuals/43 cases rehabilitated with single dental implant using the innovative DA (n = 28) and TA (n = 15) on 43 implants were included in this case study. The DA and TA support 2 or 3 dental crowns on a single implant, respectively. Clinic and radiographic examinations were presented at T1 (loading after 4 months) and T2 [final examination with an average follow-up time of 7.2 years (>3 to 12 years)]. RESULTS: At T2, mean scores for plaque index, peri-implant bleeding on probing, and peri-implant probing depth were low, depicting healthy peri-implant conditions. All radiographic images showed insignificant annual marginal bone loss (0.022 ± 0.05 mm) when compared to T1, reflecting great bone stability. CONCLUSION: DA and TA, based on the BOPiT concept, represent an advantageous, simple and non-invasive mechanism for the longevity and healthy regulation of the peri-implant tissues.

2.
Dent J (Basel) ; 12(7)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39057013

RESUMO

The objective of this study was to evaluate microbial leakage by means of genome counts, through the implant-abutment interface in dental implants with different Morse taper abutments. Fifty-six samples were prepared and divided in four groups: CMC TB (14 Cylindrical Implants-14 TiBase Abutments), CMX TB (14 Conical Implants-14 TiBase Abutments), CMX PU (14 Conical Implants-14 Universal Abutment) and CMX U (14 Tapered Implants-14 UCLA Abutments). Assemblies had their interface submerged in saliva as the contaminant. Samples were subjected either to thermomechanical cycling (2 × 106 mechanical cycles with frequency of 5 Hz and load of 120 N simultaneously with thermal cycles of 5-55 °C) or thermal cycling (5-55 °C). After cycling, the contents from the inner parts of assemblies were collected and analyzed using the Checkerboard DNA-DNA hybridization technique. Significant differences in the total genome counts were found after both thermomechanical or thermal cycling: CMX U > CMX PU > CMX TB > CMC TB. There were also significant differences in individual bacterial counts in each of the groups (p < 0.05). Irrespective of mechanical cycling, the type of abutment seems to influence not only the total microbial leakage through the interface, but also seems to significantly reflect differences considering individual target species.

3.
São José dos Campos; s.n; 2024. 86 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1551231

RESUMO

A eficácia dos implantes osseointegrados é amplamente reconhecida na literatura científica. Contudo, infiltrações bacterianas na junção implante-pilar podem desencadear inflamação nos tecidos circundantes, contribuindo para a evolução de condições mais sérias, como a peri-implantite. O objetivo desse estudo foi produzir complexos polieletrólitos (PECs) de quitosana (Q) e xantana (X) em forma de membranas, carregá-las com ativos naturais e sintéticos antimicrobianos, caracterizálas estruturalmente e avaliá-las frente a degradação enzimática, cinética de liberação e ações antimicrobianas com finalidade de aplicação para drug delivery. Membranas de QX a 1% (m/v) foram produzidas em três proporções, totalizando doze grupos experimentais: QX (1:1); QX (1:2), QX (2:1), QX-P (com própolis) (1:1); QX-P (1:2); QX-P (2:1); QX-C (com canela) (1:1); QX-C (1:2); QX-C (2:1) e CLX (com clorexidina 0,2%) (1:1); CLX (1:2); CLX (2:1). Para os estudos de caracterização foram feitas análises da espessura em estado seco; análises morfológicas superficial e transversal em Microscopia Eletrônica de Varredura (MEV); análise estrutural de espectroscopia de infravermelho por transformada de Fourier (FTIR); análise de degradação por perda de massa sob ação da enzima lisozima; e análise da cinética de liberação dos ativos em saliva artificial. Para os testes microbiológicos, análises de verificação de halo de inibição e ação antibiofilme foram feitas contra cepas de Staphylococcus aureus (S. aureus) e Escherichia coli (E. coli). Os resultados demonstraram que a espessura das membranas variou conforme a proporção, sendo que o grupo QX (1:2) apresentou a maior média de 1,022 mm ± 0,2, seguida respectivamente do QX (1:1) com 0,641 mm ± 0,1 e QX (2:1) com 0,249 mm ± 0,1. Nas imagens de MEV é possível observar uma maior presença de fibras, rugosidade e porosidade nos grupos QX (1:2) e QX (1:1) respectivamente, e, no QX (2:1) uma superfície mais lisa, uniforme e fina. No FTIR foram confirmados os picos característicos dos materiais isoladamente, além de observar as ligações iônicas que ocorreram para formação dos PECs. Na análise de degradação, os grupos com ativos naturais adicionados tiveram melhores taxas de sobrevida do que os grupos QX. No teste de liberação, os grupos QX-P tiveram uma cinética mais lenta que os QX-C, cuja liberação acumulada de 100% foi feita em 24 h. Já nos testes do halo inibitório, somente os grupos CLX tiveram ação sobre as duas cepas, e os QX-P tiveram sobre S. aureus. Nas análises antibiofilme, os grupos CLX apresentaram as maiores taxas de redução metabólica nas duas cepas (± 79%); os grupos QX-P apresentaram taxas de redução similares em ambas as cepas, porém com percentual um pouco maior para E. coli (60- 80%) e os grupos QX-C tiveram grande discrepância entre as duas cepas: de 35 a 70% para S. aureus e 14 a 19% para E. coli. Pode-se concluir que, frente as análises feitas, o comportamento do material foi afetado diretamente pelos ativos adicionados a matriz polimérica. As proporções de Q ou X afetaram somente a espessura final. Quanto a aplicação proposta de drug delivery, os dispositivos apresentaram grande potencial, principalmente os grupos CLX e QX-P. (AU)


The effectiveness of osseointegrated implants is widely recognized in scientific literature. However, bacterial infiltrations at the implant-abutment interface may trigger inflammation in surrounding tissues, contributing to the development of more serious conditions, such as peri-implantitis. The aim of this study was to produce chitosan (Q) and xanthan (X) polyelectrolyte complexes (PECs) in the form of membranes, load and evaluate them for enzymatic degradation, release kinetics, and antimicrobial actions for drug delivery applications. QX membranes at 1% (w/v) were produced in three proportions, totaling twelve experimental groups: QX (1:1), QX (1:2), QX (2:1), QX-P (with propolis) (1:1), QX-P (1:2), QX-P (2:1), QX-C (with cinnamon) (1:1), QX-C (1:2), QX-C (2:1), and CLX (with 0.2% chlorhexidine) (1:1), CLX (1:2), CLX (2:1). Characterization studies included analyses of dry state thickness, surface and crosssectional morphology using Scanning Electron Microscopy (SEM), structural analysis by Fourier Transform Infrared (FTIR) spectroscopy, mass loss degradation analysis under lysozyme action, and active release kinetics analysis in artificial saliva. Microbiological tests included verification analyses of inhibition halos and antibiofilm action against strains of Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli). Results showed that membrane thickness varied according to proportion, with group QX (1:2) presenting the highest average of 1.022 mm ± 0.2, followed by QX (1:1) with 0.641 mm ± 0.1, and QX (2:1) with 0.249 mm ± 0.1. SEM images showed greater presence of fibers, roughness, and porosity in groups QX (1:2) and QX (1:1) respectively, while QX (2:1) exhibited a smoother, more uniform, and thinner surface. FTIR confirmed characteristic peaks of the materials individually, besides showing ionic bonds formed for PECs. Degradation analysis revealed that groups with added natural actives had better survival rates than QX groups. In release tests, QX-P groups exhibited slower kinetics than QX-C, with 100% cumulative release achieved in 24 h. inhibitory halo tests, only CLX groups exhibited action against both strains, while QX-P acted against S. aureus. Antibiofilm analyses showed CLX groups with the highest metabolic reduction rates in both strains (± 79%); QX-P groups showed similar reduction rates in both strains, slightly higher for E. coli (60-80%), and QX-C groups had a significant discrepancy between strains: 35-70% for S. aureus and 14-19% for E. coli. In conclusion, material behavior was directly affected by added actives to the polymeric matrix. Proportions of Q or X only affected final thickness. Regarding proposed drug delivery applications, the devices showed great potential, especially CLX and QX-P groups.(AU)


Assuntos
Sistemas de Liberação de Medicamentos , Quitosana , Projeto do Implante Dentário-Pivô , Compostos Fitoquímicos , Polieletrólitos
4.
J Periodontol ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37846763

RESUMO

BACKGROUND: Peri-implant disease prevalence is associated with a multifactorial etiology and distinct clinical characteristics of inflammation. METHODS: The present study aimed to assess the prevalence of peri-implant diseases, identify related risk indicators, and associate specific clinical characteristics to peri-implant biological complications in the medium term. Peri-implant diseases were classified according to established case criteria. Patients' data, implant and/or prosthetic features, and maintenance records were collected. Clinical characteristics such as bleeding on probing (BOP), suppuration (SUPP), keratinized mucosa (KM), probing depth (PD), marginal recession (MR), and modified plaque index (mPI) were recorded. RESULTS: Ninety-nine patients with 266 implants with a mean functional duration of 30.26 months were evaluated. Peri-implant mucositis and peri-implantitis prevalence totaled to 49.5% and 15.15% (patient level), respectively. Peri-implant mucositis was associated with osteoporosis (odds ratio [OR] 6.09), age (OR 0.97), diabetes mellitus (OR 3.09), cemented-retained prosthesis (OR 3.81), and partial prosthesis (OR 2.21). Peri-implantitis was associated with osteoporosis (OR 7.74) and periodontitis (OR 2.74), cemented prosthesis (OR 10.12), partial and full arch prostheses (OR 12.35 and 19.86), implant diameter (OR 3.64), abutment transmucosal height (OR 3.39), and hygiene difficulty (OR 3.14). Furthermore, mPI score 3 (OR 3.27) and PD scores (OR 1.64) were associated with peri-implant mucositis, while mPI score 3 (OR 16.42), KM (OR 1.53), PD (OR 1.81), MR (OR 2.61), and the relationship between KM and PD (OR 0.63) were associated with peri-implantitis. CONCLUSION: In the medium term, peri-implant diseases were correlated with factors inherent to the patient's conditions, presurgical treatment plan, and hygiene maintenance care. The knowledge of the mentioned factors and featured clinical characteristics can be crucial for disease prevention and establishment of a superior implant therapy prognosis.

5.
Materials (Basel) ; 16(13)2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37445162

RESUMO

This study investigated the effects of antirotational titanium bases on the mechanical behavior of CAD/CAM titanium bases used for implant-supported prostheses. The aim was to assess the impact on the marginal fit, fatigue behavior, stress concentration, and fracture load of implant-supported CAD/CAM zirconia crowns. Forty titanium implants were divided into two groups: those with antirotational titanium bases (ARs) and those with rotational titanium bases (RTs). Torque loosening and vertical misfit were evaluated before and after cyclic fatigue testing (200 N, 2 Hz, 2 × 106 cycles). Fracture resistance was assessed using a universal testing machine (1 mm/min, 1000 kgf), and failed specimens were examined with microscopy. Three-dimensional models were created, and FEA was used to calculate stress. Statistical analysis was performed on the in vitro test data using two-way analysis of variance and Tukey's test (α = 0.5). Results show that the presence of an antirotational feature between the implant and titanium base reduced preload loss and stress concentration compared to rotational titanium bases. However, there were no differences in vertical misfit and resistance to compressive load.

6.
Medicina (Kaunas) ; 59(7)2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37512122

RESUMO

Background and Objectives: The insertion of the dental implant in the bone is an essential step in prosthetic rehabilitation. The insertion torque has the potential to distort the prosthetic platform, which can cause future biomechanical problems with the continuous action of occlusal forces. The aim of this study is to evaluate different insertion torques in the deformation of tri-channel platform connections through two- and three-dimensional measurements with micro-CT. Materials and Methods: A total of 164 implants were divided into groups (platform diameter and type): 3.5, 3.75, and 4.3 mm NP (narrow platform), and 4.3 mm RP (regular platform). Each implant-platform group was then divided into four subgroups (n = 10) with different torques: T45 (45 Ncm), T80 (80 Ncm), T120 (120 Ncm), and T150 (150 Ncm). The implant-abutment-screw assemblies were scanned and the images obtained were analyzed. Results: A significant difference was observed for the linear and volume measures between the different platforms (p < 0.01) and the different implant insertion torques (p < 0.01). Qualitative analysis suggested a higher deformation resistance for the 3.75 NP compared to the 3.5 NP, and RP was more resistant compared to the NP. Conclusions: The 0.25 mm increment in the implant platform did not increase the resistance to the applied insertion torques; the 4.3 mm implant was significantly stronger compared to the 3.5 mm implant; and the proposed micro-CT analysis was considered valid for both the 2D and 3D analyses of micro-gaps, qualitatively and quantitatively.


Assuntos
Próteses e Implantes , Humanos , Microtomografia por Raio-X , Torque
7.
Materials (Basel) ; 16(11)2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37297037

RESUMO

The relationship between bacterial infiltration and internal conical Implant-Abutment Interfaces (IAIs) with different conicities still requires investigations that can offer valuable information in the clinical understanding of peri-implant health. The present study aimed to verify the bacterial infiltration of two internal conical connections with an angulation of 11.5° and 16° with the external hexagonal connection as a comparative after thermomechanical cycling using saliva as a contaminant. Test (n = 10) and control (n = 3) groups were set up. Evaluations were made on torque loss, Scanning Electron Microscopy (SEM), and Micro Computerized Tomography (MicroCT) after performing 2 × 106 mechanical cycles (120 N) and 600 thermal cycles (5°-55° C) with 2 mm lateral displacement. The contents of the IAI were collected for microbiological analysis. There was a difference (p < 0.05) in torque loss of the groups tested; groups from the 16° IAI obtained a lower percentage of torque loss. All groups presented contamination and the analysis of the results shows that the microbiological profile of the IAI differs qualitatively from the profile found in the saliva used for contamination. The mechanical loading affects the microbiological profile found in the IAIs (p < 0.05). In conclusion, the IAI environment may favor a microbiological profile different from that of saliva and the thermocycling condition may alter the microbial profile found in the IAI.

8.
Eur J Oral Sci ; 131(4): e12937, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37212743

RESUMO

This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (n = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.


Assuntos
Projeto do Implante Dentário-Pivô , Implantes Dentários , Torque , Dente Suporte , Teste de Materiais , Estresse Mecânico , Parafusos Ósseos , Análise do Estresse Dentário
9.
J Biomech Eng ; 145(9)2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37195691

RESUMO

Short dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.


Assuntos
Implantes Dentários , Humanos , Estresse Mecânico , Análise de Elementos Finitos , Mandíbula/cirurgia , Análise do Estresse Dentário
10.
Artigo em Inglês | MEDLINE | ID: mdl-37067220

RESUMO

This study investigated the influence of mechanical cycling on screwed-in and tappedin implants restored with screw-retained metallic crowns. Three implant-abutmentcrown systems were evaluated: T1 (multi abutment) and T2 (standard abutment) received tapped-in abutments and S received a screwed-in abutment. The specimens were subjected to two million cycles of 0-150 N load, at 2 Hz, 30° inclination in a dry medium, and torque evaluation. Survival and removal torque were analyzed using chisquare, ANOVA, followed by Tukey's test. Differences between installation and removal torque were determined using a T-test for dependent samples. Analyses were performed in SPSS, considering α = 0.05. All specimens survived mechanical cycling in S, 40% in T1, 80% in T2 (p=0.008). Failures occurred due to loosening of the crown screw. A significant decrease in torque (p=0.000) was found. Group T1 had the lowest removal torque (1.6 ± 0.84 N.Cm²), followed by T2 (3 ± 1.49 N.Cm²) and S (6.3 ± 1.16 N. Cm²), and a statistical difference was found between Groups T1 and S. Both types of implantabutment connections were stable and can be considered for rehabilitative treatment, but failure and removal torque were influenced by the design of prosthetic abutment. Crowns were more susceptible to becoming loose in tapped-in systems.


Assuntos
Projeto do Implante Dentário-Pivô , Implantes Dentários , Torque , Dente Suporte , Análise do Estresse Dentário , Coroas , Parafusos Ósseos , Teste de Materiais