Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 185
Filtrar
1.
Nanomaterials (Basel) ; 14(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38869583

RESUMO

This paper presents an application for a molybdenum disulfide nanomaterial with multiwalled carbon nanotubes (MoS2@MWCNT/E) in a modified electrode substrate for the detection of uric acid (UA). The modified electrode generates a substantial three-fold increase in the anodic peak current for UA compared to the unmodified MWCNT electrode (MWCNT/E). The MoS2@MWCNT/E surface was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS) and electrochemical impedance spectroscopy (EIS). The achieved detection limit stood at 0.04 µmol/L, with a relative standard deviation (RSD) of 2.0% (n = 10). The method's accuracy, assessed through relative error and percent recovery, was validated using a urine standard solution spiked with known quantities of UA.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38865700

RESUMO

In recent years, polysaccharides have emerged as a promising alternative for the development of environmentally friendly materials. Polysaccharide-based materials have been mainly studied for applications in the food, packaging, and biomedical industries. However, many investigations report processing routes and treatments that enable the modification of the inherent properties of polysaccharides, making them useful as materials for energy applications. The control of the ionic and electronic conductivities of polysaccharide-based materials allows for the development of solid electrolytes and electrodes. The incorporation of conductive and semiconductive phases can modify the permittivities of polysaccharides, increasing their capacity for charge storage, making them useful as active surfaces of energy harvesting devices such as triboelectric nanogenerators. Polysaccharides are inexpensive and abundant and could be considered as a suitable option for the development and improvement of energy devices. This review provides an overview of the main research work related to the use of both common commercially available polysaccharides and local native polysaccharides, including starch, chitosan, carrageenan, ulvan, agar, and bacterial cellulose. Solid and gel electrolytes derived from polysaccharides show a wide range of ionic conductivities from 0.0173 × 10-3 to 80.9 × 10-3 S cm-1. Electrodes made from polysaccharides show good specific capacitances ranging from 8 to 753 F g-1 and current densities from 0.05 to 5 A g-1. Active surfaces based on polysaccharides show promising results with power densities ranging from 0.15 to 16 100 mW m-2. These investigations suggest that in the future polysaccharides could become suitable materials to replace some synthetic polymers used in the fabrication of energy storage devices, including batteries, supercapacitors, and energy harvesting devices.

3.
Sensors (Basel) ; 24(12)2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38931556

RESUMO

This paper reports a rapid and sensitive sensor for the detection and quantification of the COVID-19 N-protein (N-PROT) via an electrochemical mechanism. Single-frequency electrochemical impedance spectroscopy was used as a transduction method for real-time measurement of the N-PROT in an immunosensor system based on gold-conjugate-modified carbon screen-printed electrodes (Cov-Ag-SPE). The system presents high selectivity attained through an optimal stimulation signal composed of a 0.0 V DC potential and 10 mV RMS-1 AC signal at 100 Hz over 300 s. The Cov-Ag-SPE showed a log response toward N-PROT detection at concentrations from 1.0 ng mL-1 to 10.0 µg mL-1, with a 0.977 correlation coefficient for the phase (θ) variation. An ML-based approach could be created using some aspects observed from the positive and negative samples; hence, it was possible to classify 252 samples, reaching 83.0, 96.2 and 91.3% sensitivity, specificity, and accuracy, respectively, with confidence intervals (CI) ranging from 73.0 to 100.0%. Because impedance spectroscopy measurements can be performed with low-cost portable instruments, the immunosensor proposed here can be applied in point-of-care diagnostics for mass testing, even in places with limited resources, as an alternative to the common diagnostics methods.


Assuntos
Técnicas Biossensoriais , COVID-19 , Espectroscopia Dielétrica , Ouro , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/virologia , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Espectroscopia Dielétrica/instrumentação , Espectroscopia Dielétrica/métodos , Ouro/química , Eletrodos , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Imunoensaio/métodos , Imunoensaio/instrumentação , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Proteínas do Nucleocapsídeo de Coronavírus/análise , Carbono/química , Fosfoproteínas/análise
4.
Talanta ; 276: 126237, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38776769

RESUMO

Lysergic acid diethylamide (LSD) and two phenethylamine classes (NBOHs and NBOMes) are the main illicit drugs found in seized blotter papers. The preliminary identification of these substances is of great interest for forensic analysis. In this context, this work constitutes the inaugural demonstration of an efficient methodology for the selective detection of LSD, NBOHs, and NBOMes, utilizing a fully 3D-printed electrochemical double cell (3D-EDC). This novel 3D-EDC enables the use of two working electrodes and/or two supporting electrolytes (at different pHs) in the same detection system, with the possibility of shared or individual auxiliary and pseudo-reference electrodes. Thus, the selective voltammetric detection of these substances is proposed using two elegant strategies: (i) utilizing the same 3D-EDC platform with two working electrodes (boron-doped diamond (BDD) and 3D-printed graphite), and (ii) employing two pH levels (4.0 and 12.0) with 3D-printed graphite electrode. This comprehensive framework facilitates a fast, robust, and uncomplicated electrochemical analysis. Moreover, this configuration enables a rapid and sensitive detection of LSD, NBOHs, and NBOMes in seized samples, and can also provide quantitative analysis. The proposed method showed good stability of the electrochemical response with RSD <9 % for Ip and <5 % for Ep, evaluating all oxidation processes observed for studied analytes (n = 7) at two pH levels, using the same and different (n = 3) working electrodes. It demonstrates a broad linear range (20-100 and 20-70 µmol L-1) and a low LOD (1.0 µmol L-1) for quantification of a model molecule (LSD) at the two pHs studied. Hence, the 3D-EDC combined with voltammetric techniques using BDD and 3D-printed graphite electrodes on the same platform, or only with this last sensor at two pH values, provide a practical and robust avenue for preliminary identification of NBOHs, NBOMes, and LSD. This method embodies ease, swiftness, cost-efficiency, robustness, and selectivity as an on-site screening tool for forensic analysis.


Assuntos
Técnicas Eletroquímicas , Eletrodos , Dietilamida do Ácido Lisérgico , Impressão Tridimensional , Dietilamida do Ácido Lisérgico/análogos & derivados , Dietilamida do Ácido Lisérgico/química , Dietilamida do Ácido Lisérgico/análise , Técnicas Eletroquímicas/métodos , Fenetilaminas/análise , Drogas Ilícitas/análise , Humanos , Limite de Detecção , Grafite/química
5.
Polymers (Basel) ; 16(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38543428

RESUMO

Biological treatments involve the application of metallic material coatings to enhance biocompatibility and properties. In invasive therapies, metallic electrodes are utilized, which are implanted in patients. One of these invasive therapeutic procedures is deep brain stimulation (DBS), an effective therapy for addressing the motor disorders observed in patients with Parkinson's disease (PD). This therapy involves the implantation of electrodes (IEs) into the subthalamic nucleus (STN). However, there is still a need for the optimization of these electrodes. Plasma-synthesized polypyrrole doped with iodine (PPPy/I) has been reported as a biocompatible and anti-inflammatory biomaterial that promotes nervous system regeneration. Given this information, the objective of the present study was to develop and characterize a PPPy/I-coated electrode for implantation into the STN. The characterization results indicate a uniform coating along the electrode, and physical-chemical characterization studies were conducted on the polymer. Subsequently, the IEs, both coated and uncoated with PPPy/I, were implanted into the STN of male rats of the Wistar strain to conduct an electrographic recording (EG-R) study. The results demonstrate that the IE coated with PPPy/I exhibited superior power and frequency signals over time compared to the uncoated IE (p < 0.05). Based on these findings, we conclude that an IE coated with PPPy/I has optimized functional performance, with enhanced integrity and superior signal quality compared to an uncoated IE. Therefore, we consider this a promising technological development that could significantly improve functional outcomes for patients undergoing invasive brain therapies.

6.
Biosens Bioelectron ; 255: 116210, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38537427

RESUMO

Viral respiratory infections represent a major threat to the population's health globally. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causes COVID-19 disease and in some cases the symptoms can be confused with Influenza disease caused by the Influenza A viruses. A simple, fast, and selective assay capable of identifying the etiological agent and differentiating the diseases is essential to provide the correct clinical management to the patient. Herein, we described the development of a genomagnetic assay for the selective capture of viral RNA from SARS-CoV-2 and Influenza A viruses in saliva samples and employing a simple disposable electrochemical device for gene detection and quantification. The proposed method showed excellent performance detecting RNA of SARS-CoV-2 and Influenza A viruses, with a limit of detection (LoD) and limit of quantification (LoQ) of 5.0 fmol L-1 and 8.6 fmol L-1 for SARS-CoV-2, and 1.0 fmol L-1 and 108.9 fmol L-1 for Influenza, respectively. The genomagnetic assay was employed to evaluate the presence of the viruses in 36 saliva samples and the results presented similar responses to those obtained by the real-time reverse transcription-polymerase chain reaction (RT-PCR), demonstrating the reliability and capability of a method as an alternative for the diagnosis of COVID-19 and Influenza with point-of-care capabilities.


Assuntos
Técnicas Biossensoriais , COVID-19 , Vírus da Influenza A , Influenza Humana , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Vírus da Influenza A/genética , Influenza Humana/diagnóstico , Saliva , Reprodutibilidade dos Testes
7.
Neurosurg Rev ; 47(1): 43, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38216697

RESUMO

Deep brain stimulation (DBS) is a widely employed treatment for Parkinson's disease. However, conventional DBS utilizing ring-shaped leads can often result in undesirable side effects by stimulating nearby brain structures, thus limiting its effectiveness. To address this issue, a novel DBS electrode was developed to allow for directional stimulation, avoiding neighboring structures. This literature review aims to analyze the disparities between conventional and directional DBS and discuss the benefits and limitations associated with this innovative electrode design, focusing on the stimulation-induced side effects it can or cannot mitigate. A comprehensive search was conducted in MEDLINE/PubMed, ScienceDirect, and EBSCO databases using the Boolean search criteria: "Deep brain stimulation" AND "Parkinson" AND "Directional." Following the application of inclusion and exclusion criteria, the selected articles were downloaded for full-text reading. Subsequently, the results were organized and analyzed to compose this article. Numerous studies have demonstrated that directional DBS effectively reduces side effects associated with brain stimulation, prevents the stimulation of non-targeted structures, and expands the therapeutic window, among other advantages. However, it has been observed that directional DBS may be more challenging to program and requires higher energy consumption. Furthermore, there is a lack of standardization among different manufacturers of directional DBS electrodes. Various stimulation-induced side effects, including dysarthria, dyskinesia, paresthesias, and symptoms of pyramidal tract activation, have been shown to be mitigated with the use of directional DBS. Moreover, directional electrodes offer a wider therapeutic window and a reduced incidence of undesired effects, requiring the same or lower minimum current for symptom relief compared to conventional DBS. The utilization of directional leads in DBS offers numerous advantages over conventional electrodes without significant drawbacks for patients undergoing directional DBS therapy.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Humanos , Estimulação Encefálica Profunda/métodos , Eletrodos , Doença de Parkinson/terapia
8.
Nanomaterials (Basel) ; 14(2)2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38251144

RESUMO

The persistence and potential toxicity of emergent pollutants pose significant threats to biodiversity and human health, emphasizing the need for sensors capable of detecting these pollutants at extremely low concentrations before treatment. This study focuses on the development of glassy carbon electrodes (GCEs) modified by films of poly-tris(4-(4-(carbazol-9-yl)phenyl)silanol (PTPTCzSiOH), poly-4,4'-Di(carbazol-9-yl)-1,1'-biphenyl (PCBP), and poly-1,3,5-tri(carbazol-9-yl)benzene (PTCB) for the detection of metronidazole (MNZ) in aqueous media. The films were characterized using electrochemical, microscopy, and spectroscopy techniques, including scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Monomers were electropolymerized through cyclic voltammetry and chronoamperometry techniques. Computational methods at the B3LYP/def2-TZVP level were employed to investigate the structural and electrochemical properties of the monomers. The electrochemical detection of MNZ utilized the linear sweep voltammetry technique. Surface characterization through SEM and XPS confirmed the proper electrodeposition of polymer films. Notably, MPN-GCEs exhibited higher detection signals compared to bare GCEs up to 3.6 times in the case of PTPTCzSiOH-GCEs. This theoretical study provides insights into the structural, chemical, and electronic properties of the polymers. The findings suggest that polymer-modified GCEs hold promise as candidates for the development of electrochemical sensors.

9.
Talanta ; 269: 125494, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38043339

RESUMO

A new type of buckypaper of MWCNT with entrapped Nimodipine (NMD) drug was constructed. NMD features a nitroaromatic group that is electroreducible, and a dihydropyridine ring that can be electrooxidized. From the perspective of the nitroaromatic group's reductive capability, we have devised amperometric and voltammetric analytical strategies, including both differential pulse and linear voltammetric techniques. These methods are implemented using glassy carbon electrodes (GCE) modified with buckypaper (BP) disks composed of multiwalled carbon nanotubes (MWCNT), which are capable of adsorbing NMD. Furthermore, by capitalizing on the oxidative capacity of the dihydropyridine ring, we have designed strategies that involve amperometry using screen-printed electrodes (SPE) modified with BP-MWCNT mini discs within a Batch Injection Analysis Cell (BIAS) designed for SPE. The developed sensor was applied successfully to determine the drug in commercial tablets. The analytical parameters of this sensor were adequate, with a recovery value of 98.24 % and detection and quantification limits of 7.01 mgL-1 and 23.35 mgL-1, respectively using the DPV method.


Assuntos
Nanotubos de Carbono , Nanotubos de Carbono/química , Nimodipina , Eletrodos , Técnicas Eletroquímicas , Limite de Detecção
10.
Mem. Inst. Oswaldo Cruz ; 119: e230149, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1534934

RESUMO

BACKGROUND American tegumentary leishmaniasis (ATL) is an endemic neglected tropical disease (NTD), its conventional treatment is toxic, slow, and invasive. Rapid diagnosis is crucial for the clinical management of suspected patients, so the development and use of low-cost, miniaturised and portable devices could be the key. OBJECTIVES This work aimed to develop a simple paper-based electrochemical platform for the serological detection of ATL. METHODS Platform was fabricated in Whatman N°1 paper, contains a hydrophobic zone generated by wax printing, two pencil graphite electrodes, and uses specific crude extracts (CA) antigens for ATL immuno-determination. The platform performance was analysed by measuring the relative impedance change for different antigen-antibody combinations. Then, 10 serum human samples previously diagnosed by the gold standard (five positive ATL cases and five non-ATL cases) were evaluated. FINDINGS The platform presented a linear response for the charge transfer resistance (ΔRct) and the interface reactance (ΔXc). Also, optimal working conditions were established (1/60 serum dilution and 180 µg/mL CA concentration). Then, the platform permits to distinguish between ATL and non-ATL (p < 0.05) human serum samples. MAIN CONCLUSIONS Our platform could allow the diagnosis, management, and monitoring of leishmaniasis while being an extremely simple and environmentally friendly technology.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA