Materials (Basel) ; 16(24)2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38138684

RESUMO

Dental zirconias have been broadly utilized in dentistry due to their high mechanical properties and biocompatibility. Although initially introduced in dentistry as an infrastructure material, the high rate of technical complications related to veneered porcelain has led to significant efforts to improve the optical properties of dental zirconias, allowing for its monolithic indication. Modifications in the composition, processing methods/parameters, and the increase in the yttrium content and cubic phase have been presented as viable options to improve zirconias' translucency. However, concerns regarding the hydrothermal stability of partially stabilized zirconia and the trade-off observed between optical and mechanical properties resulting from the increased cubic content remain issues of concern. While the significant developments in polycrystalline ceramics have led to a wide diversity of zirconia materials with different compositions, properties, and clinical indications, the implementation of strong, esthetic, and sufficiently stable materials for long-span fixed dental prostheses has not been completely achieved. Alternatives, including advanced polycrystalline composites, functionally graded structures, and nanosized zirconia, have been proposed as promising pathways to obtain high-strength, hydrothermally stable biomaterials. Considering the evolution of zirconia ceramics in dentistry, this manuscript aims to present a critical perspective as well as an update to previous classifications of dental restorative ceramics, focusing on polycrystalline ceramics, their properties, indications, and performance.

2.
Clin Oral Implants Res ; 34(12): 1438-1449, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37674475

RESUMO

OBJECTIVE: This retrospective case series aimed to assess the stability of the papilla around four single crowns supported by narrow-diameter implants replacing all maxillary incisors. Secondary objectives included assessment of marginal bone level stability, incidence of technical and biological complications, and patient satisfaction. MATERIALS AND METHODS: Individuals with four adjacent implants in maxillary incisor sites, placed with a 3 mm inter-implant distance and rehabilitated with single crowns were included. Retrospective data were obtained from photographs and radiographs taken at the delivery of the prosthesis (baseline-T0). Patients were then recalled (≥2 years after T0) for clinical and radiographic examination (follow-up-T1). Photographs were obtained and patient satisfaction was assessed using a visual analogue scale. Papilla height and marginal bone level were compared over time. RESULTS: Data from 10 patients with medium-low smile lines and rehabilitated with 40 implants, in function for 5.4 ± 1.9 years, were analyzed. The papilla height between implants (T0: 2.3 ± 0.9 mm; T1: 2.6 ± 0.7 mm; p = .011) and between tooth and implant (T0: 3.4 ± 0.9 mm; T1: 3.8 ± 0.8 mm; p = .025) increased significantly over the years. The marginal bone level remained stable over time (T0: 0.88 ± 0.57 mm; T1: 0.71 ± 0.67 mm; p = .007). Patients were highly satisfied (97.7 ± 0.3%) with the treatment outcome. CONCLUSION: Within its limitations, this study demonstrated that four single implant-supported crowns placed at maxillary incisor sites may exhibit soft tissue and marginal bone stability over a long period of time. This treatment approach, however, should be restricted to few patients as it requires a proper case selection and skillful execution of all surgical and prosthetic steps.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Humanos , Incisivo , Seguimentos , Estudos Retrospectivos , Coroas , Resultado do Tratamento , Prótese Dentária Fixada por Implante , Planejamento de Prótese Dentária
3.
Materials (Basel) ; 15(15)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35955276

RESUMO

This study aimed to evaluate the influence of thermomechanical cycling (TMC) and type of abutment on the misfit and compressive strength of the implant−abutment interface. Forty 3.75-mm external hexagon implants with 25° angled abutments were divided into four groups (N = 10). Group A: overcast plus TMC; Group B: overcast without TMC; Group C: completely cast plus TMC; Group D: completely cast without TMC. Abutments were fixed to the implants with 32-Ncm torque, and groups A and C specimens were cyclically loaded at 80 N with 2 Hz for 1 million cycles. The misfit on the implant−abutment interface was evaluated by optical microscope (100×) and the compressive strength test was performed in a universal test machine. For statistical analysis, a two-way ANOVA and post hoc Tukey test were used. There was no difference in misfit presented by all the abutments in the absence of TMC (p > 0.05). When TMC was performed, the completely cast abutments showed greater misfit than overcast ones (p = 0.001). Regarding compressive strength, irrespective of TMC performed, the overcast abutments showed higher compressive strength values than completely cast abutments (p = 0.003). Moreover, disregarding the type of abutment used, the absence of TMC provided higher compressive strength values (p < 0.001). It was concluded that thermomechanical cyclic loading aggravated the misfit, especially in completely cast abutments, regardless of material or fabrication technique, and reduced the compressive strength of the two types of abutments tested.

4.
Braz. dent. sci ; 25(1): 1-8, 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354530

RESUMO

Several treatment options for replacement of anterior missing teeth exist, varying from no-prep (no preparation) adhesive restorations to implants. Patients' biological, psychological, economic conditions or age have an effect on the treatment choice. It is important to perform the most conservative and beneficial treatment option considering the patient based factors. The aim of this case report was to demonstrate a single session, minimally invasive, cantilevered 2-unit all-ceramic restorations replacing anterior missing teeth combined with the advantages of CAD/CAM technology and materials. (AU)


Existem várias opções de tratamento para reabilitação de dentes anteriores ausentes, variando de restaurações adesivas sem preparo (sem preparação) até implantes. As condições biológicas, psicológicas, econômicas ou a idade dos pacientes têm um efeito na escolha do tratamento. É importante realizar a opção de tratamento mais conservadora e benéfica, considerando os fatores baseados no paciente. O objetivo deste relato de caso foi demonstrar em sessão única, minimamente invasiva, um cantiléver de restaurações de cerâmica pura de 2 unidades, reabilitando a região de dentes anteriores ausentes combinadas com as vantagens da tecnologia CAD/CAM.(AU)


Assuntos
Humanos , Masculino , Adulto , Prótese Adesiva , Prótese Dentária , Desenho Assistido por Computador
5.
J Esthet Restor Dent ; 33(4): 605-612, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33423375

RESUMO

OBJECTIVE: To investigate the probability of survival and failure modes of four-unit implant-supported porcelain fused to metal (PFM) dentogingival prostheses subjected to step-stress accelerated life testing (SSALT). MATERIALS AND METHODS: Eighteen implant-supported PFM dentogingival prostheses with thin metallic infrastructures, which provided minimal ceramic support and improved esthetics were fabricated over external hexagonal connection UCLA abutments. SSALT was performed until specimen failure. Use level probability Weibull curve and reliability were calculated and plotted. Weibull modulus (m) and characteristic strength (η) were also calculated. Polarized light microscope and scanning electron microscope were used to characterize fractures. RESULTS: Failures were dictated by material strength rather than fatigue damage accumulation. The probability of survival for loads reaching 100 and 150 N in 100,000 cycles was 92 and 61%, respectively. No cracks or fractures were identified in the veneered porcelain, whereas abutment fixation screw fracture was the chief failure mode. CONCLUSION: Implant-supported PFM four-unit dentogingival prostheses with minimum metal framework dimensions presented favorable lifetime prediction under fatigue testing. Fractures were restricted to fixation screws. CLINICAL SIGNIFICANCE: In-vitro fatigue testing and failure mode analyses evidenced favorable lifetime prediction for 4-unit implant-supported dentogingival prostheses with minimum metal frameworks. Abutment fixation screw fracture might be the most frequent clinical complication. Since this proof of concept has been tested in-vitro, further studies including different restorative materials, as well as long-term clinical trials are warranted.


Assuntos
Implantes Dentários , Porcelana Dentária , Coroas , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Análise do Estresse Dentário , Gengiva , Teste de Materiais , Testes Mecânicos , Reprodutibilidade dos Testes , Zircônio
6.
Eur J Oral Sci ; 124(5): 490-497, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27680671

RESUMO

This study evaluated the probability of survival (reliability) of platform-switched fixed dental prostheses (FDPs) cemented on different implant-abutment connection designs. Eighty-four-three-unit FDPs (molar pontic) were cemented on abutments connected to two implants of external or internal hexagon connection. Four groups (n = 21 each) were established: external hexagon connection and regular platform (ERC); external hexagon connection and switched platform (ESC); internal hexagon and regular platform (IRC); and internal hexagon and switched platform (ISC). Prostheses were subjected to step-stress accelerated life testing in water. Weibull curves and probability of survival for a mission of 100,000 cycles at 400 N (two-sided 90% CI) were calculated. The beta values of 0.22, 0.48, 0.50, and 1.25 for groups ERC, ESC, IRC, and ISC, respectively, indicated a limited role of fatigue in damage accumulation, except for group ISC. Survival decreased for both platform-switched groups (ESC: 74%, and ISC: 59%) compared with the regular matching platform counterparts (ERC: 95%, and IRC: 98%). Characteristic strength was higher only for ERC compared with ESC, but not different between internal connections. Failures chiefly involved the abutment screw. Platform switching decreased the probability of survival of FDPs on both external and internal connections. The absence in loss of characteristic strength observed in internal hexagon connections favor their use compared with platform-switched external hexagon connections.


Assuntos
Coroas , Projeto do Implante Dentário-Pivô , Falha de Restauração Dentária , Dente Suporte , Implantes Dentários , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Reprodutibilidade dos Testes