Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 659
Filtrar
1.
Rev. Pesqui. Fisioter ; 14(1)mar., 2024. tab, ilus
Artigo em Inglês, Português | LILACS | ID: biblio-1565947

RESUMO

INTRODUCTION: Chronic neck pain (CNP) is a common musculoskeletal problem that affects a large proportion of the population and lasts longer than three months. It has a high cost in terms of life, disability, and healthcare. Several modalities have effectively provided immediate and long-term relief for CNP; however, the comparative clinical effectiveness of these modalities is limited. OBJECTIVES: The study aimed to determine the clinical effectiveness of Class IV Laser therapy and Therapeutic Ultrasound (TUS) in patients with CNP. METHODS AND MATERIALS: Forty-four patients with CNP of both genders were recruited from an age range of 20­45 years from the Department of Musculoskeletal Physiotherapy of Maharishi Markandeshwar Institute of Physiotherapy, MM(DU), Ambala, India. They were divided into two groups at random: the LASER group A (n = 22) and the TUS group B (n = 22). The intervention duration was 2 weeks with 6 treatment sessions. Pre- and post-treatment outcome measures were assessed with the Visual Analog Scale (VAS), Algometer, Goniometer, and Neck Disability Index (NDI) questionnaires at baseline and after 2 weeks of intervention. The LASER group received a target dose of 10 joules per cm2 at a power of 10 watts, with a continuous dosage frequency. The TUS group underwent a continuous mode ultrasound (3 MHz, 1 W/cm2) for 6 minutes. The Shapiro-Wilk test was used to assess the normality of the data. For parametric and non-parametric data analysis within the group, the paired t-test and Wilcoxon signed rank were used. The independente t-test and Mann-U Whitney test were used for the group comparison of parametric and non-parametric data, respectively. RESULTS: In both groups, there was a significant improvement in all the outcome measures (p<0.001). There was a statistically significant difference between the two interventions in VAS, Pain Pressure Threshold (PPT), and NDI (p<0.05). CONCLUSION: Class IV Laser therapy is clinically more effective than therapeutic ultrasound in treating patients with chronic neck pain.


INTRODUÇÃO: A dor cervical crônica (DCC) é um problema musculoesquelético comum que afeta uma grande proporção da população e dura mais de três meses. Ela tem um alto custo em termos de vida, incapacidade e assistência médica. Várias modalidades têm proporcionado alívio imediato e de longo prazo para a dor cervical crônica; entretanto, a eficácia clínica comparativa dessas modalidades é limitada. OBJETIVOS: O objetivo do estudo foi determinar a eficácia clínica da terapia a laser de classe IV e do ultrassom terapêutico (UST) em pacientes com DCC. MÉTODOS E MATERIAIS: Quarenta e quatro pacientes com DCC de ambos os sexos, em uma faixa etária de 20 a 45 anos, foram recrutados do Departamento de fisioterapia musculoesquelética do Instituto de Fisioterapia Maharishi Markandeshwar, MM (DU), Ambala, Índia. Eles foram divididos em dois grupos de forma aleatória: o grupo LASER A (n = 22) e o grupo UST B (n = 22). A duração da intervenção foi de 2 semanas com 6 sessões de tratamento. As medidas de resultado pré e pós-tratamento foram avaliadas com os questionários Escala Visual Analógica (EVA), Algometer, Goniometer e Índice de Incapacidade do Pescoço (IIP) na linha de base e após 2 semanas de intervenção. O grupo LASER recebeu dose alvo de 10 joules por cm2 na potência de 10 watts, com frequência de dosagem contínua. O grupo UST foi submetido a ultrassom em modo contínuo (3 MHz, 1 W/cm2) por 6 minutos. O teste de Shapiro-Wilk foi utilizado para avaliar a normalidade dos dados. Para análise dos dados paramétricos e não paramétricos dentro do grupo, foram utilizados o teste t pareado e o posto sinalizado de Wilcoxon. O teste t independente e o teste Mann-U Whitney foram utilizados para comparação de grupos para dados paramétricos e não paramétricos, respectivamente. RESULTADOS: Em ambos os grupos, houve uma melhora significativa em todas as medidas de resultado (p<0,001). Houve uma diferença estatisticamente significativa entre as duas intervenções na EVA, Limiar de pressão de dor (PPT) e IIP (p<0,05). CONCLUSÕES: A terapia a laser de classe IV é clinicamente mais eficaz do que o ultrassom terapêutico no tratamento de pacientes com dor cervical crônica.


Assuntos
Cervicalgia , Terapia a Laser , Dor Crônica
2.
Online braz. j. nurs. (Online) ; 23(supl.1): e20246677, 08 jan 2024. ilus
Artigo em Inglês, Português | LILACS, BDENF - Enfermagem | ID: biblio-1555143

RESUMO

OBJETIVO: Descrever as evidências científicas acerca do ultrassom à beira do leito, executado pelos profissionais de saúde em ambiente crítico. MÉTODO: Revisão de escopo pautado nas normas e termos metodológicos do Joanna Briggs Institute (JBI), norteada pela pergunta "Como está descrito na literatura o uso do Point-of-Care Ultrasound - POCUS / ultrassom à beira do leito pelos profissionais de saúde na assistência direta ao paciente crítico?". A busca envolve nove bases de dados e na literatura cinzenta. A seleção de evidências se apresenta em três etapas, e para o gerenciamento das referências dos estudos se utiliza o software Mendeley. A avaliação dos estudos está sustentada nos critérios preestabelecidos de inclusão, e foi realizada por três revisores, sendo dois de modo independente e um terceiro para a preciação das divergências. Os dados extraídos têm apresentação descritiva e sintética dos resultados.


OBJECTIVE: To describe the scientific evidence about bedside ultrasound health professionals performing in a critical environment. METHOD: Scope review based on Joanna Briggs Institute methodological terms and standards, guided by the question "How is the use of Point-of-Care Ultrasound - POCUS / ultrasound at the bedside described in the literature by health professionals in direct care to critical patients?". The search involves nine data bases and in the gray literature. The selection of evidence is in three stages, and the Mendeley software is used to manage study references. The study evaluation is based on the pre-established inclusion criteria and was carried out by three reviewers, two independently and a third, to assess differences. The extracted data has a descriptive and synthetic presentation of the results.


Assuntos
Ultrassom , Pessoal de Saúde , Cuidados Críticos , Testes Imediatos , Literatura de Revisão como Assunto
3.
CoDAS ; 36(3): e20220074, 2024. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1557612

RESUMO

RESUMO Comparar a medida ultrassonográfica de distância da aproximação do osso hioide no momento do pico máximo da deglutição entre indivíduos saudáveis e disfágicos neurogênicos e verificar o efeito das consistências do alimento no deslocamento do osso hioide. Estudo clínico prospectivo controlado. Foram realizadas avaliações ultrassonográficas da deglutição orofaríngea em 10 adultos com diagnóstico de disfagia orofaríngea e 10 adultos saudáveis, pareados por sexo e faixa etária. Para tanto, foi utilizado ultrassom portátil com transdutor microconvex 5-10 MHz, além de estabilizador de cabeça. As imagens ultrassonográficas foram gravadas pelo software Articulate Assistant Advanced a uma taxa de 120 quadros/segundo. Foram utilizadas as consistências de alimentos nível 0 (volume livre e 5 mL) e nível 4 (5 mL), conforme as recomendações do International Dysphagia Diet Standardisation Initiative. A distância foi mensurada no momento do pico máximo da deglutição entre a parte inferior do osso hioide e a inserção do músculo milo-hioideo. Cálculos de média e o desvio padrão foram utilizados na análise descritiva, enquanto o teste ANOVA de medidas repetidas foi aplicado na análise inferencial.Resultados evidenciaram que indivíduos disfágicos apresentaram menor elevação do osso hioide, marcada por maior distância da aproximação do osso hioide no momento do pico máximo da deglutição quando comparados aos indivíduos saudáveis, independentemente da consistência alimentar ofertada. Concluiu-se que a medida ultrassonográfica de distância da aproximação do osso hioide no momento do pico máximo da deglutição mostrou menor elevação laríngea em indivíduos com disfagia orofaríngea neurogênica quando comparados aos indivíduos saudáveis para todas as consistências alimentares ofertadas.


ABSTRACT To compare the ultrasound measurement of distance from the approximation of the hyoid bone during of the maximum deglutition peak between healthy individuals and neurogenic dysphagic individuals and to verify the effect of food consistencies on the displacement of the hyoid bone. Prospective, controlled clinical study. Ultrasound recordings of the oropharyngeal deglutition were conducted in 10 adults diagnosed with oropharyngeal dysphagia and in 10 healthy adults, matched by sex and age group. A portable ultrasound model Micro ultrasound system with a microconvex transducer 5-10 MHz, coupled to a computer as well as the head stabilizer were used. The ultrasound images were recorded using the AAA software (Articulate Assistant Advanced) at a rate of 120 frames/second. Food consistencies level 0 (free volume and 5 mL) and level 4 (5 mL) were used, based on the International Dysphagia Diet Standardisation Initiative (IDSSI). The calculation of the mean and standard deviation was used for the descriptive analysis, while the repeated measures ANOVA test was used for the inferential analysis. Results showed dysphagic individuals had lower elevation of the hyoid bone marked by a longer distance from the approximation of the hyoid bone during of the maximum deglutition peak when compared to healthy individuals, regardless of the food consistency offered. It was concluded that the ultrasound measurement of distance from the approximation of the hyoid bone during of the maximum deglutition peak showed less laryngeal elevation in individuals with neurogenic oropharyngeal dysphagia when compared to healthy individuals for all food consistencies offered.

4.
Fisioter. Mov. (Online) ; 37: e37117, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1557766

RESUMO

Abstract Introduction Ultrasound used in diathermic therapies aims to achieve temperatures between 40 and 45 °C, since temperatures above 45 °C are known to cause tissue necrosis and burns. Many studies have been conducted to investigate the effect of therapeutic ultrasound in the presence of metallic implants, using phantoms (test samples) and in vivo and ex vivo animal models. In most of these studies, the ultrasound probe is fixed in one area, while in clinical practice, it is recommended that it be moved to avoid possible local overheating. Objective To analyze the thermal field at the muscle-bone interface in phantoms in the presence or absence of metallic implants after the application of therapeutic ultrasound. Methods Phantoms composed of layers simulating fat and muscle, and a layer of beef rib bone, with and without a titanium metallic implant, were prepared. The experiment involved different intensities (1.0, 1.5, and 2.0 W/cm2) and exposure times (5 and 10 minutes), common in clinics, with linear scanning of the probe. Results The experiments indicated that the muscle/implant interface heated less than the muscle/bone interface, especially at intensities of 1.5 and 2.0 W/cm2, after 5 and 10 minutes of treatment. Conclusion The results suggest the possibility of using therapeutic ultrasound in patients with metallic implants, encouraging future research to develop evidence-based protocols and safe recommendations in physiotherapy.


Resumo Introdução O ultrassom utilizado em terapias diatérmicas visa atingir temperaturas entre 40 e 45 °C, sabendo-se que temperaturas acima de 45 °C podem causar necrose tecidual e queimaduras. Muitas pesquisas têm sido realizadas para estudar o efeito do ultrassom terapêutico na presença de implantes metálicos, utilizando phantoms (corpos de prova) e animais in vivo e ex vivo. Na maioria dessas pesquisas, o cabeçote ultrassônico está fixo em uma área, enquanto que na prática clínica recomenda-se que ele seja movimentado para evitar eventuais sobreaquecimentos locais. Objetivo Analisar o campo térmico na interface músculo-osso em phantoms na presença ou ausência de implantes metálicos após a aplicação do ultrassom terapêutico. Métodos Foram elaborados phantoms compostos de camadas simuladoras de gordura e músculo e de uma camada de osso de costela bovina, sendo esta com e sem implante metálico de titânio. O experimento envolveu diferentes intensidades (1.0, 1.5 e 2.0 W/cm2) e tempos de exposição (5 e 10 minutos) comuns em clínica, com varredura linear do cabeçote. Resultados Os experimentos indicaram que a interface músculo/implante aqueceu menos do que a interface músculo/osso, especialmente nas intensidades de 1.5 e 2.0 W/cm2, após 5 e 10 minutos de tratamento. Conclusão Os resultados obtidos apontam para a possibilidade de utilização do ultrassom terapêutico em pacientes com implantes metálicos, incentivando pesquisas futuras para desenvolver protocolos baseados em evidências e recomendações seguras na fisioterapia.

5.
J. vasc. bras ; 23: e20230117, 2024. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1558347

RESUMO

Resumo Contexto Variações anatômicas em artérias do membro superior, como a presença da artéria braquial acessória, são comuns e amplamente descritas na literatura, principalmente por estudos em cadáveres. No entanto, atualmente, é possível realizar o diagnóstico através do eco-Doppler vascular. Objetivos Identificar a incidência da artéria braquial acessória pelo eco-Doppler e comparar os achados com estudos cadavéricos. Métodos Tratou-se de um estudo prospectivo em 500 membros superiores de 250 voluntários avaliados pelo eco-Doppler com o aparelho portátil de ultrassom Sonosite Titan. Resultados Dos participantes do nosso estudo, 15,6% apresentaram a variação anatômica da artéria braquial acessória. A porcentagem está dentro da média encontrada em estudos cadavéricos, que varia de 0,2 até 22%. Ter conhecimento dessa variação é fundamental em procedimentos como punção venosa periférica, fístula arteriovenosa, cateterismo, retalhos de antebraço, cirurgias de emergência no membro superior e até mesmo correção de fraturas por gesso. Conclusões A artéria braquial acessória é uma variante frequente no membro superior. O percentual de indivíduos com a artéria braquial acessória em nosso estudo foi de 15,6% e coincide com os dados da literatura de estudos cadavéricos.


Abstract Background Anatomical variations in arteries of the upper limb, such as presence of an accessory brachial artery, are common and widely described in the literature, mainly in cadaveric studies, but it is now possible to diagnose them using vascular Doppler ultrasound. Objectives To identify the incidence of accessory brachial artery using vascular Doppler ultrasound and compare the findings with cadaveric studies. Methods This was a prospective study that examined 500 upper limbs of 250 volunteers assessed with vascular Doppler ultrasound using the Sonosite Titan portable ultrasound machine. Results 15.6% of the participants in our study had the accessory brachial artery anatomical variation. Our percentage is in line with the average rates found in cadaveric studies, which ranged from 0.2% to 22%. Being aware of this variation is fundamental in procedures such as peripheral venipuncture, arteriovenous fistula creation, catheterization, forearm flaps, emergency surgeries on the limb and even correction of fractures by cast. Conclusions The accessory brachial artery is a frequent variant in the upper limb. The percentage of individuals with an accessory brachial artery in our study was 15.6%, which agrees with data from the literature on cadaveric studies.

6.
Arq. gastroenterol ; 61: e23088, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1533822

RESUMO

ABSTRACT Background: Inflammatory bowel diseases (IBD) are associated with important changes in nutritional status. Objective: The aim of the study was to compare body fat composition between two anthropometric methods: skinfolds and ultrasonography, in patients with IBD. Methods: Single-center cross-sectional study with IBD patients in remission or active disease. For the agreement analysis between the body fat assessment methods, the Bland Altman method was used. Results: A total of 101 patients with IBD were included, 75 with Crohn's disease and 26 with ulcerative colitis. Approximately 56% of the patients with Crohn's disease and 65.4% of those with ulcerative colitis had a body fat composition above normal levels, with no significant difference between the diseases (P=0.63). The Bland-Altman concordance analysis showed that the methods for assessing the percentage of fat by the adipometer and ultrasound were not in full agreement (P=0.001), despite both presented good correlation (CC 0.961; P=0.000). Conclusion: The analysis of body fat percentage in patients with IBD was different between the skinfolds and ultrasound. Both methods can be used to assess the of body fat percentage of patients with IBD. However, monitoring of body fat sequentially and longitudinally should always be performed using the same method throughout the disease course. Prospective longitudinal studies are warranted to precisely define the role of these two methods of measuring body composition in patients with IBD.


RESUMO Contexto: As doenças inflamatórias intestinais (DII) estão associadas a alterações importantes no estado nutricional. Objetivo: O objetivo do estudo foi comparar a composição da gordura corporal entre dois métodos antropométricos: dobras cutâneas e ultrassonografia, em pacientes com DII. Métodos: Estudo transversal de centro único com pacientes com DII em remissão ou doença ativa. Para a análise de concordância entre os métodos de avaliação da gordura corporal foi utilizado o método de Bland-Altman. Resultados: Foram incluídos 101 pacientes com DII, 75 com doença de Crohn e 26 com colite ulcerativa. Aproximadamente 56% dos pacientes com doença de Crohn e 65,4% daqueles com colite ulcerativa apresentaram composição de gordura corporal acima dos níveis normais, sem diferença significativa entre as doenças (P=0,63). A análise de concordância de Bland-Altman mostrou que os métodos de avaliação do percentual de gordura pelo adipômetro e ultrassonografia não foram totalmente concordantes (P=0,001), apesar de ambos apresentarem boa correlação (CC 0,961; P=0,000). Conclusão: A análise do percentual de gordura corporal em pacientes com DII foi diferente entre as dobras cutâneas e a ultrassonografia. Ambos os métodos podem ser usados para avaliar o percentual de gordura corporal de pacientes com DII. Entretanto, o monitoramento da gordura corporal de forma sequencial e longitudinal deve ser sempre realizado utilizando o mesmo método durante todo o curso da doença. Estudos longitudinais prospectivos são necessários para definir com precisão o papel desses dois métodos de medição da composição corporal em pacientes com DII.

7.
J. vasc. bras ; 23: e20230085, 2024. graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1534796

RESUMO

Resumo O maior ramo da divisão terminal da artéria braquial é a artéria ulnar, que se origina após a fossa cubital. Essa artéria usualmente tem trajeto profundo aos músculos do antebraço anterior e é responsável pela vascularização da musculatura superficial e profunda da região ulnar do antebraço e hipotênar da mão, sendo a principal responsável pela formação do arco palmar superficial após o retináculo dos flexores. Reportamos uma variação anatômica após diagnóstico com ultrassom vascular na qual a artéria ulnar situava-se em posição superficial no antebraço. A ocorrência da artéria ulnar superficial é rara, porém de grande importância para clínicos, cirurgiões e profissionais de enfermagem.


Abstract The largest branch of the terminal division of the brachial artery is the ulnar artery, which arises after the cubital fossa. This artery usually has a deep path in the muscles of the anterior forearm and is responsible for vascularization of the superficial and deep musculature on the ulnar side of the forearm and hypothenar area of the hand. We report an anatomical variant diagnosed by Doppler ultrasound in which the ulnar artery had a superficial position in the forearm. Occurrence of a superficial ulnar artery is rare, but it is an important fact for clinicians, surgeons, and nursing professionals.

8.
Artigo em Espanhol | LILACS, BNUY, UY-BNMED | ID: biblio-1556816

RESUMO

Introducción: La valoración ultrasonográfica del peso fetal permite valorar el crecimiento y bienestar fetal pudiendo estimar el peso al nacimiento, factor determinante para el pronóstico vital. Objetivos: Determinar el margen de error ecográfico del peso fetal estimado (PFE) en relación con el peso al nacer de los neonatos de la Maternidad del Hospital de Clínicas entre los años 2020 y 2022 Materiales y Métodos: Se realizó un estudio observacional, descriptivo y transversal en mujeres que tuvieron un parto en el lugar y el período mencionado, y que contaban con ecografía obstétrica de crecimiento realizada con menos de 7 días respecto al nacimiento. Se calculó el error del PFE mediante la fórmula: (Peso al Nacer - Peso Fetal Estimado) / Peso al Nacer) x 100. Se contrastó el error del peso fetal estimado con el índice de masa corporal, diabetes y estados hipertensivos del embarazo, utilizando t de Student y con la edad gestacional y edad materna mediante el índice de Pearson tomando valores estadísticamente significativos menores a 0,05. Resultados: Se incluyeron 258 pacientes. El margen de error ecográfico del PFE fue de 8,3% DE ± 7. Se obtuvo un valor p para el IMC de 0,228, diabetes p 0,915, estados hipertensivos p 0,967, días en que se realizaba la ecografía p 0,5 y edad gestacional el p 0,001. Conclusiones: El margen de error ecográfico del PFE se encuentra por debajo de los parámetros internacionales. Se encontró asociación estadísticamente significativa con la edad gestacional, no así con las otras variables.


Introduction: Ultrasonographic assessment of fetal weight allows assessment of fetal growth and well-being and can estimate birth weight, a determining factor for vital prognosis. Objectives: Determine the ultrasound margin of error of the estimated fetal weight (EFP) in relation to the birth weight of neonates at the Maternity Hospital of the Hospital de Clínicas between the years 2020 and 2022. Materials and Methods: An observational, descriptive and cross-sectional study was carried out on women who had their birth in the aforementioned place and period and who had an obstetric growth ultrasound performed less than 7 days after birth. The error of the EPF was calculated using the formula: (Birth Weight - Estimated Fetal Weight) / Birth Weight) x 100. The error of the estimated fetal weight was contrasted with the body mass index, diabetes and hypertensive state of pregnancy, using Student's t and with gestational age and maternal age using the Pearson index taking statistically significant values ​​less than 0.05. Results: 258 patients were included. The ultrasound margin of error of the EPF was 8.3% SD ± 7. A p value was obtained for BMI of 0.228, diabetes p 0.915, hypertensive states p 0.967, days in which the ultrasound was performed p 0.5 and age gestational p 0.001. Conclusions: The ultrasound margin of error of the EPF is below the international parameters. Statistically significant associations were found with gestational age, but not with the other variables.


Introdução: A avaliação ultrassonográfica do peso fetal permite avaliar o crescimento e bem-estar fetal e pode estimar o peso ao nascer, fator determinante para o prognóstico vital. Objetivos: Determinar a margem de erro ultrassonográfica do peso fetal estimado (PFE) em relação ao peso ao nascer dos neonatos atendidos na Maternidade do Hospital de Clínicas entre os anos de 2020 e 2022. Materiais e Métodos: Foi realizado um estudo observacional, descritivo e transversal com mulheres que tiveram o parto no local e período mencionados e que realizaram ultrassonografia obstétrica de crescimento menos de 7 dias após o nascimento. O erro do PFE foi calculado pela fórmula: (Peso ao Nascer - Peso Fetal Estimado) / Peso ao Nascer) x 100. O erro do peso fetal estimado foi contrastado com o índice de massa corporal, diabetes e estado hipertensivo da gestação, utilizando-se o teste de Student. t e com idade gestacional e idade materna utilizando o índice de Pearson assumindo valores estatisticamente significativos menores que 0,05. Resultados: foram incluídos 258 pacientes. A margem de erro ultrassonográfica do PFE foi de 8,3% DP ± 7. Obteve-se valor de p para IMC de 0,228, diabetes p 0,915, estados hipertensivos p 0,967, dias em que foi realizada a ultrassonografia p 0,5 e idade gestacional p 0,001. Conclusões: A margem de erro ultrassonográfica do PFE está abaixo dos parâmetros internacionais. Foram encontradas associações estatisticamente significativas com a idade gestacional, mas não com as demais variáveis.


Assuntos
Humanos , Feminino , Gravidez , Peso ao Nascer , Ultrassonografia Pré-Natal , Erros Médicos , Peso Fetal , Estudos Transversais
9.
Texto & contexto enferm ; 33: e20230287, 2024. tab
Artigo em Inglês | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1565922

RESUMO

ABSTRACT Objective: to assess the incidence of complications related to peripherally inserted central catheters in hospitalized adult patients with Covid-19 and to discuss the potential benefits of employing insertion technologies to prevent complications. Method: a descriptive, exploratory and cross-sectional study was conducted from March 2020 to December 2021 at a high-complexity hospital. The study included patients over 18 years old with a positive diagnosis for Covid-19 who made use of peripherally inserted central catheters for venous infusion. Data collection included sociodemographic and clinical information regarding catheter insertion and use. The analysis involved Chi-square and Fisher's Exact tests, with a significance level of 0.05. Results: a total of 123 inserted catheters were analyzed. The patients' mean age was 50 years old (SD=16.37), most of them male and in the acute phase of infection (59.3%). The following significant complications related to the insertion process were identified: catheter material (p=0.01); use of Sherlock (p=0.03); need for traction (p<0.001); number of punctures (p<0.001); and difficulty in catheter progression (p<0.001). Conclusion: the study identified the main complications related to the insertion and use of PICCs and showed that employing vascular visualization technologies such as ultrasound and Sherlock 3CG® can mitigate complications, as well as maximize patient comfort, experience and safety. The research provides support for the implementation of protocols for insertion and management of peripherally inserted central catheters, thus avoiding the occurrence of adverse events.


RESUMEN Objetivo: evaluar la incidencia de complicaciones relacionadas a catéteres centrales de inserción periférica en pacientes adultos hospitalizados con Covid-19 y debatir el potencial de emplear tecnologías de inserción en la prevención de complicaciones. Método: estudio descriptivo, exploratorio y transversal, realizado entre marzo de 2020 y diciembre de 2021 en un hospital de alta complejidad. En el estudio se incluyó a pacientes mayores de 18 años con diagnóstico positivo de Covid-19 y que utilizaran catéteres centrales de inserción periférica para infusiones venosas. Se recolectaron datos sociodemográficos y clínicos sobre la inserción y el uso de los catéteres. El análisis implicó las pruebas de Chi-cuadrado y Exacta de Fischer, con 0,05 como nivel de significancia. Resultados: se analizó un total de 123 catéteres insertados. La media de edad de los pacientes fue de 50 años (DE=16,37), con mayoría del sexo masculino y en la fase aguda de la infección (59,3%). Se hicieron evidentes las siguientes complicaciones significativas vinculadas al proceso de inserción: material del catéter (p=0,01), uso de Sherlock (p=0,03), necesidad de tracción (p<0,001), cantidad de punciones (p<0,001) y dificultad de avance del catéter (p<0,001). Conclusión: el estudio identificó las principales complicaciones relacionadas a la inserción y el uso de catéteres PICC y demostró que utilizar tecnologías de visualización vascular como ultrasonido y Sherlock 3CG® puede mitigar las complicaciones, además de maximizar la comodidad, experiencia y seguridad del paciente. El trabajo de investigación presenta aportes para implementar protocolos de inserción y manejo de los catéteres centrales de inserción periférica, evitando así la incidencia de eventos adversos.


RESUMO Objetivo: avaliar a incidência de complicações relacionadas ao cateter central de inserção periferica em pacientes adultos hospitalizados com Covid-19 e discutir o potencial do uso de tecnologias de inserção na prevenção de complicações. Método: estudo descritivo e exploratório, transversal, realizado no período de março de 2020 a dezembro de 2021, em um hospital de alta complexidade. Foram incluídos no estudo pacientes maiores de 18 anos com diagnóstico positivo para Covid-19 e que fizeram uso do cateter central de inserção periférica para infusão venosa. Fez-se coleta de dados sociodemográficos e clínicos sobre a inserção e uso do cateter. A análise envolveu os testes qui-quadrado e exato de Fischer, com nível de significância de 0,05. Resultados: analisou-se um total de 123 cateteres inseridos. A média de idade dos pacientes foi de 50 anos (DP=16,37 anos), sendo a maioria do sexo masculino e na fase aguda da infecção (59,3%). Foram evidenciadas as seguintes complicações significativas atreladas ao processo de inserção: material do cateter (p=0,01), uso de Sherlock (p=0,03), necessidade de tração (p<0,001), número de punções (p<0,001) e dificuldade de progressão do cateter (p<0,001). Conclusão: o estudo identificou as principais complicações relacionadas à inserção e uso do PICC e mostrou que o uso de tecnologias de visualização vascular como o ultrassom e Sherlock 3CG® pode mitigar complicações, além de maximizar conforto, experiência e segurança do paciente. A investigação apresenta subsídios para implementação de protocolos de inserção e manejo do cateter central de inserção periférica, evitando a ocorrência de eventos adversos.

10.
BrJP ; 6(4): 374-382, Oct.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527982

RESUMO

ABSTRACT BACKGROUND AND OBJECTIVES: Wound complications and pharmacological pain relief methods used at the skin surgical site after cesarean delivery may result in women's physical and emotional burden. Thus, nonpharmacological treatments must be explored to avoid these complications and side effects on maternal health. The objective of this study was to investigate the effects of Combined Ultrasound and Electric Field Stimulation (CUSEFS) on cicatricial pain and functional capacity in immediate cesarean delivery. METHODS: This study has a randomized clinical trial, double-blind, and placebo-controlled design. Thirty women (25.7±5.0 years) in immediate postpartum were randomly assigned to three groups: Control (CG, n:9), CUSEFS (TG, n:11), and Placebo (PG, n:10). CUSEFS was performed once for 20 minutes. Cicatricial pain (McGill Pain Questionnaire) and functional capacity (Functional Capacity Check) was assessed at baseline, after the intervention, and after 30 minutes. Cohen's (d) and Mixed-design analysis of variance were used to compare groups. RESULTS: Immediately after the intervention, TG showed a decrease in cicatricial pain compared with CG in sensory (d:3.8 to 4.0), affective (d:4.0), and total categories (d:3.9). In functional capacity, TG had less difficulty than CG at walking (d:0.6) and lying down (d:1.1), and PG at rest (d: 0.9). CONCLUSION: CUSEFS might be a resource for managing cicatricial pain and functional capacity in immediate cesarean delivery. Further studies with longer duration and different CUSEFS doses/parameters are required.


RESUMO JUSTIFICATIVA E OBJETIVOS: As complicações na ferida e o uso de métodos farmacológicos de alívio da dor no local cirúrgico após a cesariana podem resultar em sobrecarga física e emocional para a mulher. Assim, tratamentos não farmacológicos devem ser explorados para evitar essas complicações e efeitos adversos à saúde materna. O objetivo deste estudo foi investigar os efeitos da terapia combinada de estimulação elétrica por meio do ultrassom (CUSEFS) na dor cicatricial e na capacidade funcional no pós-parto imediato de cesariana. MÉTODOS: Este estudo possui um desenho de ensaio clínico randomizado, duplo-cego e controlado por placebo. Trinta mulheres (25,7±5,0 anos) em pós-parto imediato de cesariana foram distribuídas aleatoriamente em três grupos: Controle (CG, n:9), CUSEFS (TG:11) e Placebo (PG, n:10). O CUSEFS foi realizado uma vez por 20 minutos. A dor cicatricial (Questionário de Dor McGill) e a capacidade funcional (Functional Capacity Check) foram avaliadas no início, após a intervenção e após 30 minutos. As análises de variância de design misto e Cohen (d) foram usadas para comparar os grupos. RESULTADOS: Imediatamente após a intervenção, o TG apresentou diminuição na dor cicatricial em relação ao CG nas categorias sensorial (d:3,8 a 4,0), afetiva (d:4,0) e total (d:3,9). Na capacidade funcional, o TG apresentou menor dificuldade que o CG na marcha (d:0,6) e deitado (d:1,1), e que o PG em repouso (d:0,9). CONCLUSÃO: O CUSEFS pode ser um recurso para o manejo da dor cicatricial e da capacidade funcional imediatamente após a cesariana. Além disso, são necessários mais estudos com maior duração e diferentes doses/parâmetros de CUSEFS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA