Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Braz J Anesthesiol ; 63(2): 170-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23601256

RESUMO

BACKGROUND AND OBJECTIVES: We investigated the effect of Nitrous Oxide (N2O) on controlled hypotension in low-flow isoflurane-dexmedetomidine anesthesia in terms of hemodynamics, anesthetic consumption, and costs. METHODS: We allocated forty patients randomly into two equal groups. We then maintained dexmedetomidine infusion (0.1 µg.kg(-1).min(-1)) for 10 minutes. Next, we continued it until the last 30 minutes of the operation at a dose of 0.7 µg.kg(-1).hour(-1). We administered thiopental (4-6 mg. kg(-1)) and 0.08-0.12 mg.kg(-1) vecuronium bromide at induction for both groups. We used isoflurane (2%) for anesthesia maintenance. Group N received a 50% O2-N2O mixture and Group A received 50% O2-air mixture as carrier gas. We started low-flow anesthesia (1L.min(-1)) after a 10-minute period of initial high flow (4.4L.min(-1)). We recorded values for blood pressure, heart rate, peripheral O2 saturation, inspiratory isoflurane, expiratory isoflurane, inspiratory O2, expiratory O2, inspiratory N2O, expiratory N2O, inspiratory CO2, CO2 concentration after expiration, Minimum Alveolar Concentration. In addition, we determined the total consumption rate of fentanyl, dexmedetomidine and isoflurane as well as bleeding. RESULTS: In each group the heart rate decreased after dexmedetomidine loading. After intubation, values were higher for Group A at one, three, five, 10, and 15 minutes. After intubation, the patients reached desired hypotension values at minute five for Group N and at minute 20 for group A. MAC values were higher for Group N at minute one, three, five, 10, and 15 (p<0.05). FiO2 values were high between minute five and 60 for Group A, while at minute 90 Group N values were higher (p<0.05). FiIso (inspiratuvar isofluran) values were lower in Group N at minute 15 and 30 (p<0.05). CONCLUSION: By using dexmedetomidine instead of nitrous oxide in low flow isoflurane anesthesia, we attained desired MAP levels, sufficient anesthesia depth, hemodynamic stability and safe inspiration parameters. Dexmedetomidine infusion with medical air-oxygen as a carrier gas represents an alternative anesthetic technique.


Assuntos
Anestesia por Inalação , Anestésicos Inalatórios/farmacologia , Hipotensão Controlada , Óxido Nitroso/farmacologia , Adulto , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Estudos Prospectivos
2.
Rev. bras. anestesiol ; 63(2): 170-177, mar.-abr. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-671556

RESUMO

JUSTIFICATIVA E OBJETIVOS: Investigamos o efeito do óxido nitroso (N2O) em hipotensão controlada durante anestesia com baixo fluxo (isoflurano-dexmedetomidina) em termos de hemodinâmica, consumo de anestésico e custos. MÉTODOS: Quarenta pacientes foram randomicamente alocados em dois grupos. Infusão de dexmedetomidina (0,1 µg.kg-1.min-1) foi mantida por 10 minutos. Subsequentemente, essa infusão foi mantida até os últimos 30 minutos de operação a uma dose de 0,7 µg.kg-1.hora-1. Tiopental (4-6 mg.kg-1) e brometo de vecurônio (0,08 0,12 mg.kg-1) foram administrados na indução de ambos os grupos. Isoflurano (2%) foi administrado para manutenção da anestesia. O Grupo N recebeu uma mistura de 50% de O2-N2O e o Grupo A recebeu uma mistura de 50% de O2-ar como gás de transporte. Anestesia com baixo fluxo (1 L.min-1) foi iniciada após um período de 10 minutos de alto fluxo inicial (4,4 L.min-1). Os valores de pressão arterial, frequência cardíaca, saturação periférica de O2, isoflurano inspiratório e expiratório, O2 inspiratório e expiratório, N2O inspiratório e expiratório, CO2 inspiratório, concentração de CO2 após expiração e concentração alveolar mínima foram registrados. Além disso, as taxas de consumo total de fentanil, dexmedetomidina e isoflurano, bem como de hemorragia, foram determinadas. RESULTADOS: A frequência cardíaca diminuiu em ambos os grupos após a carga de dexmedetomidina. Após a intubação, os valores do Grupo A foram maiores nos minutos um, três, cinco, 10 e 15. Após a intubação, os valores de hipotensão desejados foram alcançados em 5 minutos no Grupo N e em 20 minutos no grupo A. Os valores da CAM foram mais altos no Grupo N nos minutos um, três, cinco, 10 e 15 (p < 0,05). Os valores da FiO2 foram mais altos entre 5 e 60 minutos no Grupo A, enquanto foram mais altos no Grupo N aos 90 minutos (p < 0,05). Os valores de Fi Iso (isoflurano inspiratório) foram menores no Grupo N nos minutos 15 e 30 (p < 0,05). CONCLUSÃO: O uso de dexmedetomidina em vez de óxido nitroso em anestesia com isoflurano pela técnica de baixo fluxo atingiu os níveis desejados de pressão arterial média (PAM), profundidade suficiente da anestesia, estabilidade hemodinâmica e parâmetros de inspiração seguros. A infusão de dexmedetomidina com oxigênio-ar medicinal como gás de transporte é uma técnica anestésica opcional.


BACKGROUND AND OBJECTIVES: We investigated the effect of Nitrous Oxide (N2O) on controlled hypotension in low-flow isoflurane-dexmedetomidine anesthesia in terms of hemodynamics, anesthetic consumption, and costs. METHODS: We allocated forty patients randomly into two equal groups. We then maintained dexmedetomidine infusion (0.1 µg.kg-1.min-1) for 10 minutes. Next, we continued it until the last 30 minutes of the operation at a dose of 0.7 µg.kg-1.hour-1. We administered thiopental (4-6 mg. kg-1) and 0.08-0.12 mg.kg-1 vecuronium bromide at induction for both groups. We used isoflurane (2%) for anesthesia maintenance. Group N received a 50% O2-N2O mixture and Group A received 50% O2-air mixture as carrier gas. We started low-flow anesthesia (1 L.min-1) after a 10-minute period of initial high flow (4.4 L.min-1). We recorded values for blood pressure, heart rate, peripheral O2 saturation, inspiratory isoflurane, expiratory isoflurane, inspiratory O2, expiratory O2, inspiratory N2O, expiratory N2O, inspiratory CO2, CO2 concentration after expiration, Minimum Alveolar Concentration. In addition, we determined the total consumption rate of fentanyl, dexmedetomidine and isoflurane as well as bleeding. RESULTS: In each group the heart rate decreased after dexmedetomidine loading. After intubation, values were higher for Group A at one, three, five, 10, and 15 minutes. After intubation, the patients reached desired hypotension values at minute five for Group N and at minute 20 for group A. MAC values were higher for Group N at minute one, three, five, 10, and 15 (p < 0.05). FiO2 values were high between minute five and 60 for Group A, while at minute 90 Group N values were higher (p < 0.05). Fi Iso (inspiratuvar isofluran) values were lower in Group N at minute 15 and 30 (p < 0.05). CONCLUSION: By using dexmedetomidine instead of nitrous oxide in low flow isoflurane anesthesia, we attained desired MAP levels, sufficient anesthesia depth, hemodynamic stability and safe inspiration parameters. Dexmedetomidine infusion with medical air-oxygen as a carrier gas represents an alternative anesthetic technique.


JUSTIFICATIVA Y OBJETIVOS: Investigamos el efecto del óxido nitroso (N2O) en hipotensión controlada durante anestesia con bajo flujo (isoflurano-dexmedetomidina) en términos de hemodinámica, consumo de anestésico y costes. MÉTODOS: Cuarenta pacientes fueron aleatoriamente divididos en dos grupos iguales. La infusión de dexmedetomidina (0,1 µg.kg-1.min-1) se mantuvo entonces por 10 minutos. En secuencia, esa infusión se mantuvo hasta los últimos 30 minutos de operación en una dosis de 0,7 µg.kg-1.hour-1. El tiopental (4-6 mg.kg-1) y el bromuro de vecuronio (0,08 0,12 mg.kg-1) fueron administrados en la inducción de ambos grupos. El Isofluorano (2%) fue administrado para el mantenimiento de la anestesia. El Grupo N recibió una mezcla de un 50% de O2-N2O y el Grupo A recibió una mezcla de un 50% de O2-ar como gas de transporte. La anestesia con bajo flujo (1 L.min-1) fue iniciada después de un período de 10 minutos de alto flujo inicial (4,4 L.min-1). Se registraron los valores de la presión arterial, frecuencia cardíaca, saturación periférica de O2, isoflurano inspiratorio, isoflurano espiratorio, O2 inspiratorio, O2 espiratorio, N2O inspiratorio, N2O espiratorio, CO2 inspiratorio, concentración de CO2 después de la espiración y concentración alveolar mínima. Además, de determinaron las tasas de consumo total de fentanil, dexmedetomidina e isoflurano, como también la de hemorragia. RESULTADOS: La frecuencia cardíaca disminuyó en ambos grupos después de la carga de dexmedetomidina. Después de la intubación, los valores del Grupo A fueron mayores en los minutos 1, 3, 5, 10 y 15. Después de la intubación, los valores de hipotensión deseados se alcanzaron en 5 minutos en el Grupo N y en 20 minutos en el grupo A. Los valores de la CAM fueron más altos en el Grupo N en los minutos 1, 3, 5, 10 y 15 (p < 0,05). Los valores de la FiO2 fueron más altos entre 5 y 60 minutos en el Grupo A, mientras que fueron más altos en el Grupo N a los 90 minutos (p < 0,05). Los valores de Fi Iso (isoflurano espiratorio) fueron menores en el Grupo N en los minutos 15 y 30 (p < 0,05). CONCLUSIONES: El uso de la dexmedetomidina en vez del óxido nitroso en la anestesia con el isoflurano por la técnica de bajo flujo, alcanzó los niveles deseados de presión arterial promedio (PAP), profundidad suficiente de la anestesia, estabilidad hemodinámica y parámetros de inspiración seguros. La infusión de dexmedetomidina con oxígeno / aire medicinal como gas de transporte es una técnica anestésica opcional.


Assuntos
Adulto , Feminino , Humanos , Masculino , Anestesia por Inalação , Anestésicos Inalatórios/farmacologia , Hipotensão Controlada , Óxido Nitroso/farmacologia , Hemodinâmica/efeitos dos fármacos , Estudos Prospectivos
3.
Braz J Anesthesiol ; 63(2): 170-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24565122

RESUMO

BACKGROUND AND OBJECTIVES: We investigated the effect of Nitrous Oxide (N2O) on controlled hypotension in low-flow isoflurane-dexmedetomidine anesthesia in terms of hemodynamics, anesthetic consumption, and costs. METHODS: We allocated forty patients randomly into two equal groups. We then maintained dexmedetomidine infusion (0.1 µg.kg-1.min-1) for 10 minutes. Next, we continued it until the last 30 minutes of the operation at a dose of 0.7 µg.kg(-1).hour(-1). We administered thiopental (4-6 mg. kg(-1)) and 0.08-0.12 mg.kg(-1) vecuronium bromide at induction for both groups. We used isoflurane (2%) for anesthesia maintenance. Group N received a 50% O2-N2O mixture and Group A received 50% O -air mixture as carrier gas. We started low-flow anesthesia (1 L.min(-1)) after a 10-minute period of initial high flow (4.4 L.min(-1)). We recorded values for blood pressure, heart rate, peripheral O2 saturation, inspiratory isoflurane, expiratory isoflurane, inspiratory O2, expiratory O2, inspiratory N2O, expiratory N2O, inspiratory CO2, CO2 concentration after expiration, Minimum Alveolar Concentration. In addition, we determined the total consumption rate of fentanyl, dexmedetomidine and isoflurane as well as bleeding. RESULTS: In each group the heart rate decreased after dexmedetomidine loading. After intubation, values were higher for Group A at one, three, five, 10, and 15 minutes. After intubation, the patients reached desired hypotension values at minute five for Group N and at minute 20 for group A. MAC values were higher for Group N at minute one, three, five, 10, and 15 (p < 0.05). FiO2 values were high between minute five and 60 for Group A, while at minute 90 Group N values were higher (p < 0.05). Fi Iso (inspiratuvar isofluran) values were lower in Group N at minute 15 and 30 (p < 0.05). CONCLUSION: By using dexmedetomidine instead of nitrous oxide in low flow isoflurane anesthesia, we attained desired MAP levels, sufficient anesthesia depth, hemodynamic stability and safe inspiration parameters. Dexmedetomidine infusion with medical air-oxygen as a carrier gas represents an alternative anesthetic technique.


Assuntos
Anestésicos Inalatórios/administração & dosagem , Dexmedetomidina/administração & dosagem , Hipotensão Controlada/métodos , Óxido Nitroso/farmacologia , Adolescente , Adulto , Pressão Sanguínea/efeitos dos fármacos , Feminino , Fentanila/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Humanos , Isoflurano/administração & dosagem , Masculino , Pessoa de Meia-Idade , Óxido Nitroso/administração & dosagem , Oxigênio/metabolismo , Estudos Prospectivos , Tiopental/administração & dosagem , Brometo de Vecurônio/administração & dosagem , Adulto Jovem
6.
Br J Anaesth ; 107(6): 959-65, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21965050

RESUMO

BACKGROUND: The aim of this study was to test if intraoperative administration of N(2)O during propofol-remifentanil anaesthesia prevented the onset of postoperative opioid-induced hyperalgesia (OIH). METHODS: Fifty adult ASA I-II patients undergoing elective open septorhinoplasty under general anaesthesia were studied. Anaesthesia was with propofol, adjusted to bispectral index (40-50), and remifentanil (0.30 µg kg(-1) min(-1)). Patients were assigned to one of the two groups: with N(2)O (70%) and without N(2)O (100% oxygen). Mechanical pain thresholds were measured before surgery and 2 and 12-18 h after surgery. Pain measurements were performed on the arm using hand-held von Frey filaments. A non-parametric analysis of variance was used in the von Frey data analysis. P<0.05 was considered statistically significant. RESULTS: Baseline pain thresholds to mechanical stimuli were similar in both groups, with mean values of 69 [95% confidence interval (CI): 50.2, 95.1] g in the group without N(2)O and 71 (95% CI: 45.7, 112.1) g in the group with N(2)O. Postoperative pain scores and cumulative morphine consumption were similar between the groups. The analysis revealed a decrease in the threshold value in both groups. However, post hoc comparisons showed that at 12-18 h after surgery, the decrease in mechanical threshold was greater in the group without N(2)O than the group with N(2)O (post hoc analysis with Bonferroni's correction, P<0.05). CONCLUSIONS: Intraoperative 70% N(2)O administration significantly reduced postoperative OIH in patients receiving propofol-remifentanil anaesthesia.


Assuntos
Analgésicos Opioides/efeitos adversos , Anestésicos Intravenosos/farmacologia , Hiperalgesia/prevenção & controle , Óxido Nitroso/farmacologia , Dor Pós-Operatória/prevenção & controle , Piperidinas/farmacologia , Propofol/farmacologia , Adolescente , Adulto , Feminino , Humanos , Lidocaína/farmacologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Remifentanil
8.
Rev. bras. anestesiol ; 57(1): 1-7, jan.-fev. 2007.
Artigo em Português | LILACS | ID: lil-440112

RESUMO

JUSTIFICATIVA E OBJETIVOS: A instalação do pneumoperitônio durante intervenção cirúrgica videolaparoscópica induz à ativação de mecanismos neuroendócrinos, alterações cardiovasculares e hormonais. O objetivo deste estudo foi avaliar os efeitos da adição do óxido nitroso sobre a resposta simpática cardiovascular e a concentração expirada de sevoflurano (CEsevo) durante o pneumoperitônio, objetivando manter adequação anestésica avaliada por meio de parâmetros hemodinâmicos, do BIS e SEF95 por cento em colecistectomias videolaparoscópicas. MÉTODO: Foram incluídos no estudo 31 pacientes, estado físico ASA I e II, com idade entre 19 e 76 anos. A indução anestésica foi feita com sufentanil (0,3 'g.kg-1), propofol (2,5 mg.kg-1) e cisatracúrio (0,15 mg.kg-1). Durante a manutenção da anestesia, a CEsevo foi ajustada para manter o BIS entre 40 e 60. Após a instalação do pneumoperitônio, iniciou-se a administração de óxido nitroso em concentrações crescentes de 20 por cento, 40 por cento e 60 por cento. Foram aferidos os parâmetros BIS, SEF95 por cento, pressão arterial sistólica (PAS), pressão arterial diastólica (PAD), pressão arterial média (PAM) e freqüência cardíaca (FC), nos momentos M1 - 5 minutos após pneumoperitônio, M2 - quando a concentração expirada do N2O = 20 por cento (CEN2O = 20 por cento); M3 - CEN2O = 40 por cento; M4 - CEN2O = 60 por cento. RESULTADOS: Não houve diferença significativa entre PAS, PAD, PAM e FC durante os momentos estudados. Houve diferença significativa na CEsevo nos momentos estudados, com diminuição de 35 por cento quando comparou-se M1 e M4. CONCLUSÕES: O óxido nitroso, quando administrado em associação ao sevoflurano durante o pneumoperitônio em colecistectomia videolaparoscópica, propicia estabilidade hemodinâmica e diminuição do consumo de sevoflurano, com manutenção de parâmetros eletroencefalográficos compatíveis com adequação anestésica.


BACKGROUND AND OBJECTIVES: The use of pneumoperitoneum during videolaparoscopic surgeries activates neuroendocrine mechanisms, and causes cardiovascular and hormonal changes. The aim of this study was to evaluate the effects of the addition of nitrous oxide, to maintain adequate anesthetic levels, on the cardiovascular sympathetic response and in the expired concentration of sevoflurane (ECsevo) during pneumoperitoneum, by evaluating hemodynamic parameters, BIS, and SEF95 percent, during videolaparoscopic cholecystectomies. METHODS: Thirty-one patients, physical status ASA I and II, ages 19 to 76 years, were included in the study. Anesthetic induction was accomplished with sufentanyl 0.3 'g.kg-1), propofol (2.5 mg.kg-1), and cisatracurium (0.15 mg.kg-1). During the maintenance phase of anesthesia, the dose of ECsevo was adjusted to maintain BIS between 40 and 60. The administration of increasing concentrations of nitrous oxide, 20 percent, 40 percent, and 60 percent, was initiated after inducing pneumoperitoneum. The bispectral index, SEF95 percent, systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and heart rate (HR) were evaluated at M1 - 5 minutes after the pneumoperitoneum; M2 - when the expired concentration of N2O = 20 percent (ECN2O = 20 percent); M3 - ECN2O = 40 percent; M4 - ECN2O = 60 percent. RESULTS: There were no significant differences among SBP, DBP, MAP, and HR in the moments studied. There was a significant difference in ECsevo in those same moments, with a 35 percent reduction when M1 and M4 were compared. CONCLUSIONS: When nitrous oxide is administered in association with sevoflurane during pneumoperitoneum in videolaparoscopic cholecystectomy, it provides for hemodynamic stability and reduces the amount of sevoflurane needed while, at the same time, maintaining electroencephalographic parameters compatible with adequate anesthesia.


JUSTIFICATIVA Y OBJETIVOS: La instalación del pneumoperitoneo durante la intervención quirúrgica videolaparoscópica activa mecanismos neuroendócrinos, alteraciones cardiovasculares y hormonales. El objetivo de este estudio fue el de evaluar los efectos de la adición del óxido nitroso sobre la respuesta simpática cardiovascular y la concentración expirada de sevoflurano (CEsevo) durante el pneumoperitoneo, para mantener la adecuación anestésica evaluada a través de parámetros hemodinámicos, del BIS y SEF95 por ciento en colecistectomías videolaparoscópicas. MÉTODO: Se incluyeron en el estudio 31 pacientes, estado físico ASA I y II, con edad entre 19 y 76 años. La inducción anestésica se realizó con sufentanil (0,3 µg.kg-1), propofol (2,5 mg.kg-1) y cisatracurio (0,15 mg.kg-1). Durante la anestesia, la CEsevo se ajustó para mantener el BIS entre 40 y 60. Posteriormente a la instalación del pneumoperitoneo, se inició la administración de óxido nitroso en concentraciones aumentadas de 20 por ciento, 40 por ciento y 60 por ciento. Se comprobaron los parámetros BIS, SEF95 por ciento, presión arterial sistólica (PAS), presión arterial diastólica (PAD), presión arterial promedio (PAM) y frecuencia cardiaca (FC), en los momentos M1 - 5 minutos después pneumoperitoneo, M2 - cuando la concentración expirada del N2O = 20 por ciento (CEN2O = 20 por ciento); M3 - CEN2O = 40 por ciento; M4 - CEN2O = 60 por ciento. RESULTADOS: No hubo diferencia significativa entre PAS, PAD, PAM y FC durante los momentos estudiados. Hubo diferencia significativa en la CEsevo en los momentos estudiados, con una reducción de un 35 por ciento cuando se la comparó a M1 y M4. CONCLUSIONES: El óxido nitroso, cuando se administra en asociación con el sevoflurano durante el pneumoperitoneo en colecistectomía videolaparoscópica, propicia estabilidad hemodinámica y la reducción del consumo de sevoflurano, manteniendo los parámetros electroencefalográficos compatibles con la adecuación anestésica.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Colecistectomia , Laparoscopia , Monitoramento Ambiental , Óxido Nitroso/farmacologia , Pneumoperitônio , Cirurgia Vídeoassistida
9.
Rev. argent. anestesiol ; 64(5): 187-193, oct.-nov. 2006. tab
Artigo em Espanhol | LILACS | ID: lil-452064

RESUMO

Introducción: El índice A-Line (AAI) permite monitorizar la profundidad anestésica. Objetivo: Determinar las dosis inductoras (DI) de propofol (P) y tiopental (T) mediante AAI. Evaluar la influencia del óxido nitroso 50 por ciento sobre las DI. Pacientes y método: Estudio prospectivo, controlado, en 120 pacientes ASA I-II, con IMC < 30, divididos en cuatro grupos: grupo P1 (n=30): O2 100 por ciento; Grupo P2 (n=30): N2O/O2 50 por ciento, Grupo T1 (n=30): O2 100 por ciento; Grupo T2 (n=30): N2O/O2 50 por ciento. Se instaló equipo de AAI. Se administró propofol (1 por ciento) o tiopental (2,5 por ciento) a 120 ml/h hasta obtener un AAI < 40 (hipnosis clínica) y AAI < 20 (nivel quirúrgico). Se registraron los signos vitales y las DI para AAI de 40 y 20. Resultados: Las DI de P: Grupo P1, 132,3 mg (AAI 40) y 185,6 mg (AAI 20), correspondientes a 1,91 ± 0,67 mg/kg y 2,78 ± 0,72 mg/kg. En el Grupo P2 las DI fueron de 94,7 mg (AAI 40) y 122,4 mg (AAI 20), correspondientes a 1,23 ± 0,3 mg/kg y 1,69 ± 0,47 mg/kg (p< 0,01, P2 v/s P1). Las DI de tiopental: Grupo T1 fue 349,5 mg (AAI 40) y 504,3 mg (AAI 20), correspondientes a 5,62 ± 0,9 mg /kg y 7,96 ± 1,2 mg/kg. En el Grupo T2, las DI fueron 311,2 mg (AAI 40) y 414,3 mg (AAI 20), correspondientes a 4,01 ± 0,7 mg/kg y 5,21 ± 0,9 mg/kg (p < 0,01 T2 v/s T1). Conclusiones: La utilización de AAI permite determinar adecuadamente las DI de P y T. La inhalación de N2O 50 por ciento reduce las DI de P y T.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Feminino , Pessoa de Meia-Idade , Anestesia Geral , Propofol/farmacologia , Tiopental/farmacologia , Monitorização Intraoperatória/métodos , Óxido Nitroso/farmacologia , Potenciais Evocados Auditivos
10.
Rev. argent. anestesiol ; 64(5): 187-193, oct.-nov. 2006. tab
Artigo em Espanhol | BINACIS | ID: bin-119086

RESUMO

Introducción: El índice A-Line (AAI) permite monitorizar la profundidad anestésica. Objetivo: Determinar las dosis inductoras (DI) de propofol (P) y tiopental (T) mediante AAI. Evaluar la influencia del óxido nitroso 50 por ciento sobre las DI. Pacientes y método: Estudio prospectivo, controlado, en 120 pacientes ASA I-II, con IMC < 30, divididos en cuatro grupos: grupo P1 (n=30): O2 100 por ciento; Grupo P2 (n=30): N2O/O2 50 por ciento, Grupo T1 (n=30): O2 100 por ciento; Grupo T2 (n=30): N2O/O2 50 por ciento. Se instaló equipo de AAI. Se administró propofol (1 por ciento) o tiopental (2,5 por ciento) a 120 ml/h hasta obtener un AAI < 40 (hipnosis clínica) y AAI < 20 (nivel quirúrgico). Se registraron los signos vitales y las DI para AAI de 40 y 20. Resultados: Las DI de P: Grupo P1, 132,3 mg (AAI 40) y 185,6 mg (AAI 20), correspondientes a 1,91 ± 0,67 mg/kg y 2,78 ± 0,72 mg/kg. En el Grupo P2 las DI fueron de 94,7 mg (AAI 40) y 122,4 mg (AAI 20), correspondientes a 1,23 ± 0,3 mg/kg y 1,69 ± 0,47 mg/kg (p< 0,01, P2 v/s P1). Las DI de tiopental: Grupo T1 fue 349,5 mg (AAI 40) y 504,3 mg (AAI 20), correspondientes a 5,62 ± 0,9 mg /kg y 7,96 ± 1,2 mg/kg. En el Grupo T2, las DI fueron 311,2 mg (AAI 40) y 414,3 mg (AAI 20), correspondientes a 4,01 ± 0,7 mg/kg y 5,21 ± 0,9 mg/kg (p < 0,01 T2 v/s T1). Conclusiones: La utilización de AAI permite determinar adecuadamente las DI de P y T. La inhalación de N2O 50 por ciento reduce las DI de P y T. (AU)


Assuntos
Humanos , Masculino , Adolescente , Adulto , Feminino , Pessoa de Meia-Idade , Anestesia Geral , Propofol/farmacologia , Tiopental/farmacologia , Potenciais Evocados Auditivos/efeitos dos fármacos , Monitorização Intraoperatória/métodos , Óxido Nitroso/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA