Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Talanta ; 135: 138-44, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25640137

RESUMO

A novel method for preconcentration and electrochemical detection of zinterol in bovine urine samples was developed. In order to improve the limit of detection, the surface of a screen-printed carbon electrode was modified with electrodeposited metal copper nanoparticles. The experimental electrodeposition optimization was performed using a central composite design (CCD), involving the variables: precursor concentration, potential and time applied. Copper nanoparticles were characterized by transmission electron microscopy, scanning electron microscopy, cyclic voltammetry, and energy dispersive X-ray spectroscopy. Mesoporous shuttle-like copper oxide nanoparticles were used for the preconcentration step to avoid interferences with many compounds present in the sample matrix. The optimal working conditions for the preconcentration approach were found by means of both two-level fractional factorial and CCD designs. The obtained enhancement factor for a sample volume of 30 mL was 35 fold. The calibration curve showed linearity between 0.5 and 45 ng mL(-1) and the limit of detection was 0.16 ng mL(-1). The intra and inter assay coefficients of variability were below 4% and 5%; respectively.


Assuntos
Agonistas Adrenérgicos beta/urina , Cobre/química , Etanolaminas/urina , Aditivos Alimentares/análise , Nanopartículas Metálicas/química , Agonistas Adrenérgicos beta/química , Ração Animal , Animais , Carbono/química , Bovinos , Eletroquímica , Eletrodos , Etanolaminas/química , Aditivos Alimentares/química , Inocuidade dos Alimentos , Carne
2.
J Anal Toxicol ; 24(2): 146-52, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10732954

RESUMO

Two extraction/clean-up analytical procedures were investigated and compared regarding their recovery and matrix-purification efficiency for screening beta2-agonist residues in fortified bovine urine by high-resolution gas chromatography-mass spectrometry (GC-MS). The first procedure, based on an analytical method originally developed for detecting anabolic steroids, consists of the employment of the nonionic resin, Amberlite XAD-2, a styrene-divinylbenzene copolymer for solid-phase extraction (SPE), followed by liquid-liquid extraction with diethyl ether. The second focuses on the use of a mixed SPE cartridge (reversed-phase and ion-exchange sorbent, Bond Elut Certify). In both cases, the trimethylsilylated derivatives were analyzed by GC-MS with an ion-trap detector. Clenbuterol, salbutamol, and terbutaline were used to spike urine samples during the comparison experimental phase. Afterwards, tulobuterol, mabuterol, mapenterol, cimbuterol, and brombuterol were included in the evaluation of the second procedure (the Bond Elut Certify procedure). At this stage, the detection was accomplished by GC-MS (quadrupole mass analyzer) with selective ion monitoring acquisition. The isotopic dilution method with the hexadeuterated analogues of clenbuterol and salbutamol was applied to prepare calibration curves and calculate recovery percentages. With XAD-2 resin, terbutaline and salbutamol (resorcinol and phenol-type beta2-agonists, respectively) could not be detected at 20 ng/mL or at 40 ng/mL. In spite of clenbuterol having been detected at 20 ng/mL, the results obtained were not reproducible. The use of the reversed-phase and ion-exchange sorbent Bond Elut Certify allowed multiresidue detection and showed several advantages for the screening of clenbuterol such as higher recoveries, cleaner final extracts, reduced sample preparation time, less labor intensive, and easier solvent consumption and disposal. Recoveries over 88% (concentrations ranging from 0.5 to 10 ppb) and limits of detection equal to 0.5 ppb were met for all the beta2-agonists studied with the last method.


Assuntos
Agonistas Adrenérgicos beta/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Animais , Brasil , Bovinos , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Estrutura Molecular
SELEÇÃO DE REFERÊNCIAS