Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.306
Filtrar
1.
Braz Oral Res ; 38: e061, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109762

RESUMO

To evaluate the polymerization shrinkage stress and cuspal strain (CS) generated in an artificial (typodont) and in a natural tooth using different resin composites. Twenty artificial and 20 extracted natural molars were selected. Each tooth was prepared with a 4x4 mm MOD cavity. The natural and typodont teeth were divided into four experimental groups (n=10), according to the resin composite used: Filtek Z100 (3M Oral Care) and Beautifil II LS (Shofu Dental). The cavities were filled using two horizontal increments and the CS (µS) was measured by the strain gauge method. Samples were sectioned into stick-shaped specimens and the bond strength (BS) (MPa) was evaluated using a microtensile BS test. Shrinkage stress and CS were analyzed using 3D finite element analysis. No difference was found between the type of teeth for the CS as shown by the pooled averages: Natural tooth: 541.2 A; Typodont model: 591.4 A. Filtek Z100 CS values were higher than those obtained for Beautifil II LS, regardless of the type of teeth. No statistical difference was found for the BS data. Adhesive failures were more prevalent (79.9%). High shrinkage stress values were observed for Filtek Z100 resin, regardless of tooth type. The CS of typodont teeth showed a shrinkage stress effect, generated during restoration, equivalent to that of natural teeth.


Assuntos
Resinas Compostas , Análise do Estresse Dentário , Análise de Elementos Finitos , Teste de Materiais , Polimerização , Estresse Mecânico , Resistência à Tração , Resinas Compostas/química , Humanos , Valores de Referência , Propriedades de Superfície , Reprodutibilidade dos Testes , Colagem Dentária/métodos , Coroa do Dente
2.
Clin Oral Investig ; 28(8): 465, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39098966

RESUMO

OBJECTIVE: To evaluate the effect of four different photoactivation protocols (according to "photoactivated faces" - mesial/distal, cervical/incisal or center - and "photoactivation time" - 6-3 s) of a high-power photo activator (Valo Cordless®-Ultradent) on the shear bond strength (SBS) between metal brackets and dental enamel and on the degree of conversion (DC) of an orthodontic resin. MATERIALS AND METHODS: 40 bovine incisor crowns were randomly assigned to 4 groups (n = 10). The brackets were bonded with Transbond XT® resin using 4 protocols according to the "photoactivation protocol" factor (which was subdivided into photoactivated faces and photoactivation time): V3C = 3 s + center; V6C = 6 s + center; V3M3D = 3 s on mesial + 3 s on distal; V3C3I = 3 s on cervical + 3 s on incisal. All the samples were stored for 4 months (water,37ºC) and then subjected to a SBS test (100KgF,1 mm/min). 40 resin discs were made to evaluate the monomer degree of conversion. Data from the SBS and DC were assessed by One-way ANOVA and Tukey's test (5%). Bond failures were analyzed according to the Adhesive Remnant Index (ARI) and evaluated by the Kruskal-Wallis test (5%). RESULTS: There was a statistically significant difference (p = 0.008) in the One-way ANOVA result for SBS values between all groups, but the protocols showed statistically similar results (p ≥ 0.05-Tukey's tests) concerning the photoactivated faces (V6C, V3M3D and V3C3I) and photoactivation time (V3C and V6C) factors individually. There was no statistically significant difference (p ≥ 0.05) in the One-way ANOVA result for DC values. CONCLUSION: The SBS and DC values will vary depending on the protocol applied. CLINICAL RELEVANCE: It is possible to maintain the bracket fixation quality with the use of a high-power LED photo activator associated with a shorter photoactivation time. However, it is assumed that not all types of protocols that might be applied will provide quality bonding, such as V3C, V3M3D and V3C3I, which may - depending on the SBS and DC values - affect the final treatment time, due to brackets debonding, or increase of possibility of damage to dental enamel during bracket removal. Clinical studies are suggested to confirm the hypotheses of this research.


Assuntos
Colagem Dentária , Esmalte Dentário , Análise do Estresse Dentário , Teste de Materiais , Braquetes Ortodônticos , Distribuição Aleatória , Cimentos de Resina , Resistência ao Cisalhamento , Animais , Bovinos , Colagem Dentária/métodos , Cimentos de Resina/química , Esmalte Dentário/química , Propriedades de Superfície , Técnicas In Vitro , Fatores de Tempo , Coroa do Dente , Polimerização
3.
Braz Dent J ; 35: 5669, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045984

RESUMO

This study evaluated the influence of hydrofluoric acid (HF) concentration and thermal cycling on the microshear bond strength (µSBS) of a resin luting agent to IPS e.max® CAD and Rosetta® SM. Ceramic specimens (12.0 x 14.0 x 1.5mm) were randomized into 8 groups (n=10) according to HF concentration, commercial brand, and aging. Immediately after polishing, and etching, all specimens were silanized and a layer of adhesive was applied. A PVS mold of 3 mm thickness and 10mm diameter with (four) 1.0mm holes was fabricated, placed on each specimen, and then filled with a resin luting agent. Half of the specimens were subjected to the µSBS test using an Instron at a speed of 1.0 mm/min, following a 24-hour storage in deionized water at 37ºC. The remaining specimens were subjected to thermal cycling (5ºC-55ºC, 30 seconds per bath) and µSBS. The data were evaluated utilizing a three-way ANOVA and Tukey's post-hoc test (α=0.05). Significant differences were found for HF concentration and aging (p<0.0001). No significant difference in µSBS was found for commercial brands (p=0.085). The interaction between brand and HF concentration (p=0.358), brand and aging (p=0.135), and HF concentration and aging (p=0.138) were not statistically significant. The triple interaction among these factors was not statistically significant (p=0.610). In conclusion, the bond strength is affected by the HF concentration. No statistical difference was observed between the two ceramics. Thermal cycling significantly reduced µSBS.


Assuntos
Cerâmica , Colagem Dentária , Ácido Fluorídrico , Cimentos de Resina , Ácido Fluorídrico/química , Cimentos de Resina/química , Cerâmica/química , Teste de Materiais , Análise do Estresse Dentário
4.
Braz Dent J ; 35: 5746, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045986

RESUMO

This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.


Assuntos
Resinas Compostas , Colagem Dentária , Dentina , Vidro , Técnica para Retentor Intrarradicular , Humanos , Resinas Compostas/química , Colagem Dentária/métodos , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Materiais Dentários/química , Dente não Vital
5.
Braz Dent J ; 35: 5798, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045988

RESUMO

Resorbed alveolar ridges, particularly in the lower jaw, have a small denture supporting area, which may cause the stress distribution of mastication load to exceed the pressure-pain threshold (PPT) and induce pain in the mucosa or potentially worsen the ridge resorption. Thus, choosing the ideal occlusal scheme among bilateral balanced (BBO), lingualized (LO), and monoplane (MO) for such conditions becomes crucial. The experiment was conducted using the finite element method on a modeling of a resorbed alveolar ridge in the lower jaw with three dentures placed on top, each of which was given different loading points according to the tooth arrangement of BBO, LO, and MO. The axial load was 100 N, and the resultant oblique loads on BBO and LO were 119 N and 106 N, respectively. The von Mises stresses for BBO, LO, and MO were observed in nine denture-supporting areas, and the results showed that the axial load did not produce stresses that exceeded the PPT value (0.64925 MPa) for BBO, LO, and MO with the highest value on area H, 0.43229 MPa, 0.39715 MPa, and 0.31576 MPa, respectively. However, the oblique load direction showed that the BBO had more areas (area E 0.80778 MPa and area H 0.76256 MPa) that exceeded the PPT than LO (area E 0.64394 MPa). The lingualized occlusal scheme is ideal for patients with resorbed alveolar ridge conditions, especially in terms of limiting interferences when the denture is functioning while maintaining comfort but still providing good masticatory performance and satisfactory esthetics.


Assuntos
Análise de Elementos Finitos , Humanos , Processo Alveolar , Análise do Estresse Dentário , Perda do Osso Alveolar , Oclusão Dentária , Mandíbula , Mastigação/fisiologia
6.
Oper Dent ; 49(4): 455-464, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38978307

RESUMO

OBJECTIVE: To evaluate the effect of polyethylene fiber-reinforcement on the fracture resistance and fracture mode of extensive resin-based composite (RBC) restorations in structurally compromised maxillary premolars. METHODS AND MATERIALS: Maxillary premolars (54) with specific dimensions and extracted for orthodontic reasons were used. Following mesio-occluso-distal (MOD) cavity preparation and endodontic access, teeth were randomly assigned to one of three restorative protocols (n=18): RBC applied incrementally (I) or reinforced with woven polyethylene fibers (Ribbond) placed horizontally (H) or U-shaped (U). Restored teeth were stored for 45 days in distilled water at 37°C and then loaded monotonically until fracture. Half of the specimens in each group received axial loading (A) and the other half was loaded paraxially (PA). Fracture load data was assessed using two-way analysis of variance and Tukey's post hoc test for multiple comparisons (α=0.05). The fracture initiation and propagation path were analyzed using stereomicroscopy and scanning-electron microscopy. RESULTS: No significant differences were observed for the fracture strength among loading configurations, except for groups IA (825 N) and HA (553 N). Fracture initiated and propagated mainly at and through the RBC restoration in the I group, whereas a shift to the interface was observed in both polyethylene fiber-reinforced groups. Blocking and bridging of cracks were identified around the fibers, especially in specimens of group U. CONCLUSIONS: Incorporation of woven polyethylene fibers to reinforce extensive MOD resin-based composite restorations on endodontically treated premolars reduced the occurrence of cohesive fractures in the restorative material but was unable to increase the fracture resistance of the affected teeth.


Assuntos
Dente Pré-Molar , Resinas Compostas , Falha de Restauração Dentária , Restauração Dentária Permanente , Análise do Estresse Dentário , Humanos , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Técnicas In Vitro , Restauração Dentária Permanente/métodos , Polietileno/química , Polietileno/uso terapêutico , Microscopia Eletrônica de Varredura , Teste de Materiais , Fraturas dos Dentes/prevenção & controle , Dente não Vital/terapia , Polietilenos
7.
J Dent ; 148: 105242, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-39009334

RESUMO

OBJECTIVE: To investigate fatigue methods for the evaluation of translucent zirconia and to associate in vitro failures with clinically reported ones. DATA: Studies published in English that used fatigue tests on dental translucent zirconia. SOURCES: Two databases (MEDLINE/PubMed and Scopus) were electronically searched without any restriction on year of publication. STUDY SELECTION: A total of 4555 studies were identified. After removal of duplicates (78) and irrelevant articles (4316) that did not meet the inclusion criteria, 161 articles were considered eligible based on their titles and abstracts. These articles were fully read, leading to the inclusion of 41 studies in the review. RESULTS: The most widely used fatigue method for evaluation of translucent zirconia was step-stress (18 articles), followed by staircase (seven articles), and step-wise (two articles). Most studies had been conducted in a wet environment with the use of a stainless steel piston to apply load to cemented structures on a dentin-like substrate. Most fracture analyses indicated the fracture originated on the cementation or contact surface where the load was applied. Moreover, studies that utilized anatomical structures (dental crowns) reported fractures starting at the cervical margin of the crowns. CONCLUSION: Most studies used the step-stress method. Only three studies reported failures similar to those found in clinical trials that used translucent zirconia restorations. CLINICAL SIGNIFICANCE: The study findings can assist on correlating clinical failures to the ones observed in vitro.


Assuntos
Materiais Dentários , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Zircônio , Zircônio/química , Humanos , Materiais Dentários/química , Coroas , Propriedades de Superfície , Estresse Mecânico
8.
J Oral Implantol ; 50(4): 431-434, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38826061

RESUMO

The purpose of the present study was to evaluate the Morse effect of different internal tapered implant-abutment connections (ITCs) using a pullout test. Implants with different ITCs were selected: Short (Bicon, USA), G1; Novo Colosso (Medens, Brazil), G2; Epkut (SIN, Brazil), G3; Strong SW (SIN, Brazil), G4; Flash (Conexão, Brazil), G5 and Bone Level (Straumann, Switzerland), G6. The respective computer-aided design (CAD) files were loaded into the analysis software to measure each ITC's taper angle and implant-abutment contact area. Six implants from each group were embedded in acrylic resin blocks, and the respective universal abutments were fixed using a mallet (G1) or by applying 20 Ncm of torque (G2 to G6). After 10 minutes, each abutment's retention screw was removed, and the force necessary for abutment rupture was recorded using a universal testing machine at a crosshead speed of 0.5 mm/min. The groups were compared using a one-way analysis of variance and Tukey's test. Spearman's correlation was used to check the correlation of the taper angle and contacting area with the pullout strength. G1, a no-screw abutment with a 3° taper, and G2, a 10° tapered abutment tightened by 20 Ncm, presented the highest pullout strength (P < .05). The increased taper angle of G4, compared to G3, reduced the Morse effect despite their similar implant-abutment contacting areas (P < .05). The G5 and G6 abutments loosened after screw removal and did not exhibit pullout resistance. The closer the tapered angle (r = -.958) and the higher the implant-abutment contact area (r = .880), the higher the pullout strength (P < .001). Within the limits of this study, the Morse effect is different among tapered implant-abutment connections. The closer the tapered angle and the higher the interface area, the higher the Morse effect between the abutment and the implant.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Projeto do Implante Dentário-Pivô , Análise do Estresse Dentário , Implantes Dentários , Torque , Humanos , Teste de Materiais
9.
Clin Oral Investig ; 28(7): 386, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38890207

RESUMO

OBJECTIVE: This study aimed to evaluate the effect of ultrasonic activation of etch-and-rinse and self-etch adhesive systems on the bond strength of resin cement to irradiated root dentin. MATERIALS AND METHODS: Eighty human maxillary anterior teeth were distributed into 8 groups (n = 10), according to the type of adhesive system used (etch-and-rinse and self-etch), the ultrasonic activation of the adhesive systems, and the dentin condition (irradiated or non-irradiated - 70 Gy). Endodontic treatment was performed followed by fiberglass post-space preparation. After fiberglass posts' luting, the roots were transversely sectioned on dentin discs and submitted to the push-out bond strength test (0.5 mm/min). The fractured specimens were analyzed under a stereomicroscope and Scanning Electron Microscope (SEM) for failure mode classification. One of the dentin discs was analyzed under SEM to evaluate the characteristics of the adhesive interface. RESULTS: Irradiated specimens had lower bond strength than non-irradiated specimens (P < 0.0001). Ultrasonic activation of both adhesive systems increased the bond strength of the resin cement to irradiated dentin (P < 0.0001). Radiotherapy significantly affected the failure mode in the middle (P = 0.024) and apical thirds (P = 0.032) (adhesive failure). CONCLUSION: Non-irradiated specimens had a more homogeneous adhesive interface. When ultrasonically activated, both adhesive systems showed a greater number of resinous tags, regardless of the dentin condition. CLINICAL RELEVANCE: Ultrasonic activation of adhesive systems is a feasible strategy to enhance fiberglass posts retention in oncological patients.


Assuntos
Colagem Dentária , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular , Cimentos de Resina , Humanos , Cimentos de Resina/química , Colagem Dentária/métodos , Dentina/efeitos da radiação , Técnicas In Vitro , Adesivos Dentinários/química , Análise do Estresse Dentário , Propriedades de Superfície , Raiz Dentária/efeitos da radiação , Ultrassom , Condicionamento Ácido do Dente , Incisivo , Vidro/química
10.
Dent Mater ; 40(9): 1332-1340, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38876825

RESUMO

OBJECTIVES: To evaluate structural damage and loosening of abutments placed on narrow diameter implants after cyclic fatigue. METHODS: Sixty Morse taper narrow diameter implants (Neodent, Brazil) received two types of abutments (1PA- one-piece abutment or 2PA- two-piece abutment), which were randomly divided into 3 fatigue experiments (n = 10). The implants were placed into a customized supporting holder and a software-assisted digital torque wrench secured the manufacturer recommended torque for each abutment. Cone beam computed tomography (CBCT) scans were acquired, before and after fatigue, and post-processed (software e-Vol DX) to assess damage and abutment displacement. The boundary fatigue method was adapted to use 2 × 106 cycles, 2 Hz of frequency and constant peak load of 80 N (first experiment) that varied according to the failure rate of previous specimens (second and third experiments). Failure was evaluated using CBCT scans and removal torque values. Data were used to estimate long-term torque degradation, probability of failure and Weibull modulus (software ALTA PRO9). RESULTS: All 2PA specimens became loosen independently of the applied fatigue load, and structural bending was observed in 14 abutments. Eight 1PA got loosen during the fatigue experiment. The Weibull analysis showed a lower modulus (m = 1.0; 0.7, 1.4) for 1PA than for 2PA (m = 2.6; 2, 3.4) resulting in longer predicted lifetimes and slower torque degradation for 1PA than for 2PA specimens. SIGNIFICANCE: 1PA showed greater long-term survival probability than 2PA. Predicting the lifetime and mechanical behavior of implant-abutment systems are useful information to clinicians during the decision-making process of oral rehabilitations.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dente Suporte , Projeto do Implante Dentário-Pivô , Falha de Restauração Dentária , Análise do Estresse Dentário , Torque , Implantes Dentários , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA